PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Frequency band power”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

A comparison of median frequency, spectral edge frequency, a frequency band power ratio, total power, and dominance shift in the determination of depth of anesthesia.

Five numerical descriptors were derived from the electroencephalogram (EEG), recorded, and processed (Tracor Nomad) during emergence from isoflurane-nitrous oxide anesthesia. The five descriptors (median frequency, spectral edge frequency-90%, total power, a frequency band power ratio, and the ratio of frontal to occipital power) were compared for their ability to predict imminent arousal. Arousal was defined as spontaneous movement, coughing or eye opening. All of the descriptors except the frontal-occipital power ratio underwent significant (P less than 0.05) changes between the initial recordings made intraoperatively during surgical stimulus under anesthesia and later recordings in the 40 s preceding arousal. A post hoc analysis was performed to identify the threshold value for each parameter that best served to predict imminent arousal. For median frequency, spectral edge frequency-90%, total power, and the frequency band power ratio, thresholds that predicted imminent arousal with sensitivities of 90% and specificities of 82-90% could be identified. The data indicate that, even in the favorable circumstances of the present study (uniform anesthetic technique, post hoC identification of thresholds), none of several previously popularized EEG descriptors (median frequency, spectral edge frequency-90%, total power, a frequency band power ratio) can serve as a completely reliable sole predictor of imminent arousal. As presently derived, these EEG descriptors at best provide trend information to be used in concert with other clinical signs of depth of anesthesia.

Adult↗

[The influence of ketamine on the bispectral index, the spectral edge frequency 90 and the frequency bands power during propofol anesthesia].

To investigate the influence of ketamine on the bispectral index (BIS), the spectral edge frequency 90 (SEF 90) and relative power in four frequency bands (beta, alpha, theta, sigma), we studied 13 patients (ASA I-II) undergoing elective surgery. In the first study (n = 7), we administered ketamine (1.0 mg.kg-1, bolus, i.v.) during propofol anesthesia. Thirty minutes after the administration, BIS, SEF 90 and relative beta power increased significantly. In the second study (n = 6), bolus administration of ketamine (0.5 mg.kg-1 i.v.) followed by continuous infusion was started during propofol anesthesia. The infusion rate of ketamine was 0.5 mg.kg-1.h-1 for 30 minutes and then increased to 1.0 mg.kg-1.h-1. BIS, SEF 90 and relative beta power increased significantly after ketamine administration, but the parameters did not change in dose-related manner. We conclude that further investigation is necessary to use electroencephalographic parameters as an indicator of the anesthesia depth during propofol/ketamine anesthesia.

Analgesics↗

Assessment of ultra low frequency band power of heart rate variability: validation of alternative methods.

UNLABELLED: Alternative methods for assessing ULF spectral power using data from commercial Holter analysers were studied. Different heuristics for ULF calculation were compared with standard research software-based determination of ULF. SETTING: University Hospital. PATIENTS: 43 patients in NYHA classes I-IV heart failure and seven normals of similar ages. METHODS: SDNN, SDANN, ULF, VLF, LF, HF calculated from 24 h Holter monitoring using Oxford scanner software (method 1). ULF power also calculated by subtracting the sum of VLF. LF and HF powers obtained from the Holter scanner from the total variance (method 2) from 2 x ln(SDANN) (method 3), and by performing a standard, research-quality 24-h EFT analysis on the beat files (standard). Results of methods 1-3 were compared with standard using two-way ANOVA with repeated measures, regression analysis and a graphical technique. RESULTS: ULF calculated by method 1 correlated r=0.66 with standard but means differed substantially. In contrast, ULF calculated by method 2 correlated r=0.99 with standard with no significant differences between means. ULF calculated from SDANN (method 3) correlated r=0.983 with standard but means, while similar, were significantly lower (P=0.005). CONCLUSION: ULF reported by commercial HOLTER software is not equivalent to ULF power derived from 24 h FFT analysis. ULF calculated by method 2 can be considered equivalent to the ULF derived by standard 24-h FFT. ULF estimated by method 3 offers direct ULF power estimation from a temporal measure of HRV and can be useful when spectral values are not available.

Electrocardiography, Ambulatory↗

EEG responses to long-term audio-visual stimulation.

In this study, linear and nonlinear electroencephalogram (EEG) changes due to long-term audio-visual stimulation (AVS) were investigated. In the course of 2 months, 25 repetitions of a 20-min AVS program with stimulation frequencies in the range 2-18 Hz were applied to six healthy volunteers. EEG data were recorded from six head locations during relaxed wakefulness prior to AVS. Then linear spectral measures (total power, frequency band powers, spectral edge frequency, and spectral entropy), nonlinear measures of complexity (histogram-based entropy and correlation dimension), interdependency measures (linear correlation coefficient, mutual information, and coherence), and measures of subjective assessment were estimated. Evolution of these measures during the whole experiment period was analyzed with respect to the significance of their linear regression. Our results confirm that repetitive training with audio-visual stimulation does induce changes in the electro-cortical activity of the brain. Long-term AVS significantly increased power in theta-1, theta-2, and alpha-1 bands in the frontal and central cortex locations. Total power increased in the right central region. Interhemispheric coherence in alpha-1 band displayed a significant increase between frontal parts in contrast to the decrease of both linear correlation and mutual information. Correlation dimension significantly decreased in some locations while entropy displayed an ascending trend.

Acoustic Stimulation↗

Identification of development and autonomic nerve activity from heart rate variability in preterm infants.

Heartbeat intervals, which are determined basically by regular excitations of the sinoatrial node, show significant fluctuation referred to as the heart rate variability (HRV). The HRV is mostly due to nerve activities through the sympathetic and parasympathetic branches of the autonomic nervous system (ANS). In recent years, it has been recognized that the HRV shows a greater complexity than ever expected, suggesting that it includes much information about ANS activities. In this study, we investigated relationship between HRV and development in preterm infants. To this end, heartbeat intervals were continuously recorded from 11 preterm infants in NICU. The recording periods were ranging from several days to weeks depending on the individuals. The HRV at various ages was then characterized by several indices. They include power spectrum as well as the mean and standard deviation of the series. For the power spectrum, the low-frequency band power (LF), high-frequency band power (HF), LF/HF (the ratio between LF and HF), beta (scaling exponent of the spectrum) were estimated. The detrended fluctuation analysis (DFA) was also employed to obtain short- and long-range scaling exponents. Each of these indices showed a correlation with the age. We showed that the long-range scaling exponent, derived from the DFA, was most significantly correlated with the age, suggesting that it could be a robust index to characterize the development of preterm infants.

Autonomic Nervous System↗

Individual analysis of EEG frequency and band power in mild Alzheimer's disease.

OBJECTIVE: This EEG study investigates the role of the cholinergic system, cortico-cortical connections, and sub-cortical white matter on the relationship between individual EEG frequencies and their relative power bands. METHODS: EEGs were recorded at rest in 30 normal elderly subjects (Nold), 60 mild Alzheimer disease (AD) and 20 vascular dementia (VaD) patients, comparable for Mini Mental State Evaluation scores (MMSE 17-24). Individual EEG frequencies were indexed by the theta/alpha transition frequency (TF) and by the individual alpha frequency (IAF) with power peak in the extended alpha range (5-14 Hz). Relative power was separately computed for delta, theta, alpha1, alpha2, and alpha3 bands, on the basis of the TF and IAF. RESULTS: Using normal subjects as a reference, VaD patients showed 'slowing' of alpha frequency (TF-IAF) and lower alpha2 power; Mild AD patients showed lower alpha2 and alpha3 power; delta power was higher in both AD and VaD patients; Theta power was higher only in VaD patients. CONCLUSIONS: Individual analysis of the alpha frequency and power can discriminate mild AD from VaD and normal elderly subjects. SIGNIFICANCE: This analysis may probe pathophysiological mechanisms causing AD and VaD.

Aged↗

Assessment of autonomic nerve function in acute intermittent porphyria; a study based on spectral analysis of heart rate variability.

OBJECTIVES: To assess the function of the autonomic nervous system in patients with acute intermittent porphyria by spectral analysis of the heart rate variability. DESIGN: A cross-sectional case-control study. SETTING: Patients were examined at the Primary Health Care Centre, Arjeplog and at Umeå University Hospital, where the controls were also examined. SUBJECTS: Twenty-three patients with acute intermittent porphyria verified by DNA analysis and 92 healthy controls were included. MAIN OUTCOME MEASURES: The mid-frequency band power after tilting was used to evaluate sympathetic function, and the high frequency band power during controlled breathing at 12 breaths min-1 and the mid-frequency band power during controlled deep breathing at 6 breaths min-1 were used to evaluate parasympathetic function. RESULTS: There was no evidence of sympathetic dysfunction in the patients. The mid-frequency band power during controlled deep breathing at 6 breaths min-1 was significantly (P = 0.02) lower in the patient group. CONCLUSIONS: Our findings indicate a parasympathetic dysfunction in patients with acute intermittent porphyria. This may be causally related to sudden cardiac death and the life-threatening arrhythmias which have been observed in this disorder.

Adult↗

Electroencephalographic characteristics of emergence from propofol/sufentanil total intravenous anesthesia.

We recorded the electroencephalogram (EEG) in 16 patients during propofol/sufentanil total intravenous anesthesia to determine whether EEG changes might predict imminent awakening during emergence. Changes in absolute and relative power in four frequency bands, median frequency (MF), 95th percentile frequency (F95), and two frequency band power ratios (beta/alpha and (alpha+beta)/delta) were quantified. One minute before eye opening, absolute power in the delta and alpha bands had decreased to 49% (25%-73%) and 42% (25%-58%) of the value during the infusion (P > 0.005). MF, F95, and the two frequency band power ratios increased during emergence (P > 0.05). Of the individual spectral variables, only a 50% decrease in absolute alpha power was more than 90% sensitive and specific in predicting eye opening. We conclude that, although pronounced EEG changes occur during emergence from propofol/sufentanil anesthesia, the EEG does not reliably predict eye opening.

Adult↗

Autonomic regulation of cardiac function during sleep in patients with irritable bowel syndrome.

OBJECTIVE: Several studies have provided evidence of abnormal autonomic activity in irritable bowel syndrome (IBS), suggesting that abnormal central nervous system-autonomic nervous system arousal mechanisms may be part of its pathophysiology. The goal was to investigate cardiac sympatho-vagal balance during waking and the different stages of sleep using heart rate variability analysis in IBS patients compared to healthy controls. METHODS: A total of 15 IBS patients (13 female, two male, mean age 34.9 +/- 2.1 yr) and 15 controls (13 female, two male, mean age 36.2 +/- 2.3 yr) were studied during 1 h of pre-sleep quiet waking and during seven-hours of sleep. Polysomnography was used for the determination of state of consciousness. Electrocardiography provided the beat-to-beat intervals, which were then subjected to spectral analysis for determination of the percentage of energy in the low and high frequency bands, respectively. The low frequency/high frequency band ratio was also calculated. For each subject, heart rate variability analysis was performed using 15-min segments of waking, non-rapid eye movement sleep, and rapid eye movement sleep. RESULTS: The low frequency band power was significantly greater in IBS patients during waking. No group differences were found in high frequency band power during any state. The low frequency to high frequency band ratio was significantly greater in IBS patients during rapid eye movement sleep. CONCLUSIONS: IBS patients have greater sympathetic activity during waking and greater overall sympathetic dominance during rapid eye movement sleep. These results support the presence of autonomic abnormalities in patients with IBS. The possibility is discussed that sympathetic dominance during rapid eye movement sleep may play a role in sensitizing the gut to waking stimulation.

Adult↗

Cardiovascular control and plasma catecholamines during rest and mental stress: effects of posture.

In order to understand the complex autonomic adjustments that occur during the psychological challenges of normal daily life, autonomic responses to psychological stress were studied by evaluating the effects of body posture on various indices of sympathetic and parasympathetic regulation during performance of a psychological task. Twelve male subjects were studied in various postures (supine, sitting and standing), and during performance of the Colour Word Test (CWT) when sitting and then when standing. This procedure was subsequently repeated in reverse order (first standing and then sitting) after 15 min of supine rest. Blood samples for assay of plasma catecholamines were obtained before and during each CWT. Spectral analysis of beat-to-beat variations of heart rate (HR) and blood pressure (BP) was applied in order to obtain non-invasive indices of sympathetic and parasympathetic regulation. HR, diastolic BP, mid-frequency band power (0.07-0.14 Hz) of HR and systolic BP, and plasma adrenaline and noradrenaline concentrations showed significant increases when changing from supine to sitting to standing posture, whereas high-frequency band power (0.15-0.50 Hz) of HR decreased in a posture-dependent fashion. In the sitting position, the CWT caused significant increases in HR, BP and plasma adrenaline levels, and decreased HR and BP variability indices. In the standing posture, the CWT responses differed significantly from those during sitting for HR (a mild decrease during standing), high-frequency band power of HR (decreased more while sitting), high-frequency band power of BP (decreased more while standing), and plasma adrenaline responses (larger during sitting). Posture-related differential effects were observed on indices of sympatho-adrenomedullary activation during performance of a psychological challenge, whereas indices of parasympathetic activity indicated primarily less vagolytic effects when the task was performed in the standing posture. Our findings therefore underline the complexity of the adjustments that occur in neurohumoral and haemodynamic parameters during the psychological challenges of daily life.

Adult↗

Body sway characteristics during static upright posture in healthy and disordered elderly.

This study aimed to compare body sway characteristics of the healthy elderly and the disordered elderly. The subjects were 38 healthy elderly and 24 disordered elderly with disequilibrium. The latter consisted of two groups: 12 elderly with vestibular organ or central nervous systems disorder (central nervous disorders), and 12 elderly with disorder in other systems (other disorders). The measurement device can calculate the center of foot pressure (CFP) of vertical loads from the values of three vertical load sensors, which are located at the corners of an isosceles triangle on a level surface. The data sampling frequency was 20 Hz. Four body sway factors with high reliability (unit time sway, front-back sway, left-right sway, and high frequency band power) were used to evaluate body sway. As compared with healthy people, central nervous disorders had larger unit time sway, high frequency band power, and left-right sway factors. Other disorders were larger in unit time sway and high frequency band power factors. Central nervous disorders, as compared with other disorders, had larger unit time sway and left-right sway factors. Disorders produced large and fast sway, and central nervous disorders in particular showed a marked sway in the left-right direction. The existence of disease influenced body sway more than decline in various functions related to posture control with aging, because even with the same elderly, disorders showed a larger body sway.

Aged↗

Effects of toluene exposure on the spontaneous cortical activity in rats.

Effects of toluene on the electroencephalogram (EEG) and its power spectra were measured during a 2-hr exposure in a dynamic inhalational chamber in rats. Rats were exposed to one of six graded concentrations (110.6, 162.5, 432, 676, 1558, 2730 ppm) of toluene on different days. It was found that the duration of waking (W) was increased with a decrease in duration of rapid eye movement (REM) sleep even at 110.6 ppm. Duration of nonrapid eye movement (NREM) sleep was decreased with an increase of W and a decrease of REM sleep at 162.5 ppm. Dose-related effects were noted in higher concentrations. The power of delta frequency band was increased with a decrease of theta frequency band power at hr 1 of exposure to 676 ppm during REM sleep recorded from the visual cortex. The power of theta frequency band was also decreased at hr 2 of exposure at 432 ppm. During W and NREM sleep power spectra were not changed significantly. Results indicate that the changes of EEG are a sensitive measure of the effects of toluene on the central nervous system (CNS).

Administration, Inhalation↗

Monitoring sedation levels by EEG spectral analysis.

Real-time electroencephalographic power spectra were obtained for a group of 37 volunteers undergoing sedation with enflurane at different concentrations in air. In part one, 17 subjects were given 0.5%, 0.75%, and 1.0% for 4 min at each level, and recovery after 5 min was assessed by the Trieger method. There was considerable variation in subject response to the different doses, but adequate sedation was indicated by the presence of a strong alpha rhythm (9-11 Hz) and suppression of frequencies below 5 Hz. Overdose was indicated by an initial shift in the alpha frequency to a lower value (6-7 Hz) followed by the appearance of delta waves (0.5-4 Hz) and loss of alpha waves. In part two, 20 volunteers inhaled enflurane at 0.5% for 10 min to allow adequate absorption, followed by a 10-min recovery period. Equal numbers showed sedation or a failure to respond to enflurane at this concentration. In the responders, sedation was accompanied by a marked shift in the ratio of the power in two frequency bands: 1-4 Hz and 8-12 Hz. Progress of the frequency band power ratio followed closely the state of the subject into sedation, overdose, and recovery. This measure was further improved by the use of multivariate analysis, which showed good discrimination of the alert, sedated, and overdosed states of the subject.

Adult↗

Functional changes in autonomic nervous system and baroreceptor reflex induced by 14 days of 6 degrees head-down bed rest.

We studied the effects of 14 days of 6 degrees head-down bed rest (HDBR) in 16 healthy male subjects to examine the functional changes in the autonomic nervous system and cardiac baroreceptor reflex response with an emphasis on dynamic changes during HDBR. Beat-by-beat RR intervals (RRIs) and systolic arterial pressures (SAPs) were measured non-invasively from simultaneous, continuous recordings of ECG and arterial pressure waves in supine resting postures. A power spectrum analysis by the fast Fourier transform was applied to a data set composed of interpolated 512 RRIs and 512 SAPs (256 s in duration). Three indices of cardiac baroreceptor reflex sensitivity (BRS) were obtained by applying a sequence technique and a cross-spectrum analysis technique to the spontaneous RRIs and SAPs. The high-frequency band power of RRI variability (HF(RRI)) decreased significantly in the latter part of HDBR and persisted until the initial stage of the post-HDBR period (POST). The low-frequency band power of SAP variability decreased significantly only during the mid-part of HDBR. The BRS(sequence) obtained by the sequence technique showed a significant increase temporarily on the initial day of HDBR. The BRS(sequence) and the estimate of BRS obtained by the cross-spectrum analysis handling the high-frequency band were both significantly decreased on the initial day of POST. Each of the BRS estimates correlated negatively with heart rate and positively with HF(RRI) during HDBR and POST. These results suggest the following: (1) cardiac spontaneous baroreceptor reflex sensitivity might be transiently increased at the initial stage of HDBR, (2) the reduction in vagal modulation on the sinus node occurs from the latter part of HDBR to the initial stage of POST, (3) sympathetic vasomotor control is probably slightly inhibited during the mid-part of HDBR, and (4) the enhancement in cardiac sympathetic modulation and the impairment in cardiac spontaneous baroreceptor reflex sensitivity may occur in the initial stage of POST.

Adaptation, Physiological↗

[The mathematical rationale for the clinical EEG-frequency-bands. 1. Factor analysis with EEG-power estimations for determining frequency bands].

In order to determine whether the clinically used frequency bands of the EEG can also be obtained by a mathematical system we did a factor analysis with 480 EEG recordings, 5 minutes each, in 60 healthy male volunteers. A power spectrum analysis was done and 57 frequency bands between 1.5 and 30.0 Hz in a half Hz steps were calculated. The factor structure obtained made the following frequency bands (Hz) reasonable: deltaF = 1.5 - 6.0, thetaF = 6.0 - 8.5, alpha1F = 8.5 - 10.5, alpha2F = 10.5 - 12.5, beta1F = 12.5 - 18.5, beta2F = 18.2 - 21.0, beta3F = 21.0 - 30.0. Except for alpha1F all other 6 frequency bands were represented by one general factor with the complexity 1. The variance of the alpha1F band is explained by several of the 6 factors. The clinically known and the by factor analysis obtained frequency bands in the beta-range are similar. The clinically alpha-band is subdivided into two frequency bands alpha1F and alpha2F by the factor analysis. The clinically known border line between delta- and theta-band of 3.5 Hz cannot be found by factor analysis.

Adult↗

Gender differences in body-sway factors of center of foot pressure in a static upright posture and under the influence of alcohol intake.

This study aimed to examine gender differences in 4 body-sway factors of the center of foot pressure (CFP) during a static upright posture and the influence of alcohol intake on them. Four body-sway factors were interpreted in previous studies using factor analysis (the principal factor method and oblique solution by promax-rotation) on 220 healthy young males and females as follows; unit time sway, front-back sway, left-right sway and high frequency band power. The CFP measurement for 1 min was carried out twice with 1 min rest. The measurements of blood pressure, heart rate, whole body reaction time, standing on one leg with eyes closed, and CFP were carried out before and after the alcohol intake using 11 healthy young males and females. The measurement device used was an Anima's stabilometer G5500. The data sampling frequency was 20 Hz. Reliability of 4 body-sway factors was very high. Significant gender differences were found in the left-right sway and the high frequency band power factors, but the influence on body-sway is, as a whole, can be disregarded. These four sway factors can determine the influence of alcohol intake as efficient as 32 sway parameters.

Alcohol Drinking↗

Diurnal spectral EEG fluctuations in narcoleptic patients during rest and reaction time tasks.

Narcolepsy is associated with lowered vigilance. Diurnal variation in vigilance appears altered, but the exact nature of this change is unclear. It was hypothesized that the homeostatic sleep drive is increased in narcolepsy. Decreased levels of vigilance are reflected in low frequency band power in the electroencephalogram (EEG), so these frequencies were expected to be increased in the narcolepsy group. Furthermore, it was expected that low frequency power should increase over the day. Narcoleptic patients and healthy controls participated (36 participants in total); they were not allowed to take medication or naps on the experimental day. EEG was measured at 9:00, 11:00, 13:00, 15:00, and 17:00 hours, during rest and during reaction time tasks. In the narcolepsy group, alpha power was lower at rest at all times. Delta and theta power during rest and task performance increased steadily over the day in this group, from 11:00 hours onwards. Additionally, in the narcolepsy group beta1 and beta2 power during rest appeared increased at the end of the day. The effects in the lower frequency bands strongly suggest that vigilance is low at all times. The progressive increase in low frequency power indicates that the sleep drive is enhanced. It is not clear whether this pattern reflects an extreme state of low vigilance, or a pathological brain condition. The effects in the higher frequencies suggest that narcoleptic patients may make an effort to counteract their low vigilance level.

Adult↗