PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Heart Valve Prosthesis Implantation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

[Prognostication of the outcome of heart valve prosthesis implantation by the method of nonlinear chaos dynamics of the heart rate].

An examination of 39 patients with heart diseases was performed before and after operations by the method of geometrical analysis of the nonlinear chaos (fractal) variability of the cardiac rhythm on the basis of the apparatus-programmed complex "Poly-spectrum". Five-minute-long registrations of ECG were carried on. On the basis of the data of examination of 195 healthy volunteers the reference norm of this method parameters was determined. Reliably lower parameters were found in patients with the acquired valvular disease. A dynamic investigation of the geometrical nonlinear structure of the cardiac rhythm has shown the possibility to make a prognosis of early complications after prosthetics of the heart valves.

Adult↗

[Use of cytochrome C in the prevention of myocardial reperfusion injury during heart valve prosthesis implantation under conditions of extracorporeal circulation].

Cytochrome C used at the postischemic period causes a rapid reestablishment of coronary circulation, hemodynamic parameters, prevents activation of lipid peroxidation in reoxygenation of the heart after prolonged total myocardial ischemia in patients with acute bacterial endocarditis in whom the prostheses of heart valves had been fulfilled. Parallel with the positive inotropic effect, Cytochrome C reduces the postloading and, as a result, transfers the cardiac muscle to a more profitable regimen. At the end of the myocardial ischemia period Cytochrome C provides rapid and effective recovery of the bioelectrical function of the heart, improves its pumping function, thus allowing the dose and duration of inotropic stimulation of the myocardium at the postischemic period to be reduced, lowers pulmonary resistance and finally leads to less postoperative intrahospital lethality from acute heart failure.

Animals↗

[Two-cusp plasty using a pedicled auto pericardial patch for the right ventricular outflow tract in complete repair of tetralogy of Fallot].

BACKGROUND: Pulmonary stenosis (PS) and regurgitation (PR) are major concerns late after transannular patching for tetralogy of Fallot (TOF). In this study, we reviewed the TOF patients undergoing transannular patching to reveal whether the valvuloplasty technique (two cusp plasty) improved long-term results. We also reviewed potential for grow of the pedicled autopericardial patch. METHODS AND RESULTS: Since 1977, 151 patients underwent corrective surgery for TOF. Transannular patching was required in 58 (38.4%). PS and PR in the postoperative long-term period of these 59 cases were reviewed. 25 patients had the standard transannular patching (S-TAP), and 33 had two-cusp plasty (TCP). Pedicled autologous pericardial patch were used in 9 patients of TCP. Actuarial freedom from PS at 7 years was 70.8 +/- 9.2% in S-TAP and 79.2 +/- 8.3% in TCP, and there was no significant difference. Incidence of severe PR was significantly higher in S-TAP (7/24) than TCP (1/24) (p < 0.05). Actuarial freedom from PR at 7 year was 69.6 +/- 9.6% in the former and 95.8 +/- 4.2% in the later, respectively. The diameter of the pulmonary arterial annuals was augmented with the somatic growth in 6 patients with the pedicled pericardial patch. CONCLUSIONS: Two cusp plasty was more effective to prevent PR in the postoperative long-term period, comparing to S-TAP. As the material of the patch, pedicled autologous pericardium showed satisfactory outcome.

Blood Vessel Prosthesis Implantation↗

Expanding the use of total mitral valve preservation in combination with implantation of the CarboMedics heart valve prosthesis.

BACKGROUND: Preservation of the mitral valve and subvalvular apparatus was introduced into the clinic in the early sixties, but for two decades the standard technique for mitral valve replacement included excision of both leaflets and their attached chordae tendineae. Lately, increased emphasis has again been placed on retention of the mitral subvalvular apparatus during valve replacement because of its role on left ventricular function. METHODS: We have preserved the valvular and subvalvular mitral apparatus, when possible, in connection with mitral valve replacement during the last seven years and the present investigation (partly prospective and partly retrospective) was done with the aim of making up the results of our mitral preservation technique. In the period between January 1990 and December 1995, 30% of the patients who underwent mitral valve replacement had complete retention of all mitral tissue. In 1996, the percentage had increased to 50, and during the first seven months of 1997, 70% of the patients had complete retention of all mitral tissue. Since January 1997, we have exclusively used the CarboMedics mitral heart valve prosthesis. A total of 56 patients were identified to have had a CarboMedics heart valve prosthesis implanted. There were 33 men and 23 women with a mean age of 63 years, range 23-77 years. Coronary bypass was a concomitant procedure in 22 patients. In seven patients, both the mitral and aortic valves were replaced. A severely altered valve with thickened and or calcified leaflets, stenotic leaflets, or shortened, retracted and thickened chordae tendineae were not a contraindication for the procedure. Calcified plaques were removed. Adhesion between anterior and posterior leaflets was treated with sharp dissection. Valve and subvalvular tissue were preserved. The leaflets were reefed within the valve-sutures and compressed between the sewing ring and the native annulus when implanting the valve prosthesis. Chordal tension on the ventricle was thereby maintained and the chordae pulled away from the valve effluent. Echocardiography with measurement of ejection-fraction was performed preoperatively during the postoperative course in case of cardiac problems and on a routine basis 1 month after surgery and at various intervals when the patient was seen in the outpatient clinic. Left ventricular outflow tract gradients were measured during the postoperative course in case of cardiac problems and routinely 1 month postsurgically. RESULTS: Five patients died in the postoperative period and one patient had transient neurological symptoms. In none of the patients was death or transient neurological symptoms a consequence of the retention of mitral leaflets with subvalvular apparatus. The remaining 51 patients were all alive at follow-up. Postoperative echocardiography demonstrated a preserved left ventricular function and a left ventricular outflow tract without obstruction. CONCLUSIONS: We find that the described technique in combination with implantation of a CarboMedics heart valve prosthesis is very useful even in patients with a severely altered valve, when preserving the mitral leaflets with subvalvular apparatus during valve replacement. The technique is without procedure related complications and preserves left ventricular function without obstructing the left ventricular outflow tract.

Adult↗

Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis.

OBJECTIVES: This study was done to assess the results of percutaneous heart valve (PHV) implantation in non-surgical patients with end-stage calcific aortic stenosis. BACKGROUND: Replacement of PHV has been shown to be feasible in animals and humans. We developed a PHV composed of three pericardial leaflets inserted within a balloon-expandable stainless steel stent. We report the acute and early follow-up results of the initial six PHV implantations. METHODS: An anterograde approach was used in all cases. The PHV, crimped over a 22-mm diameter balloon, was advanced through a 24-F sheath from the femoral vein to the aortic valve and delivered by balloon inflation. Clinical, hemodynamic, and echocardiographic outcomes were assessed serially. RESULTS: All patients were in New York Heart Association functional class IV. The PHV was successfully delivered in five patients. Early migration with subsequent death occurred in one patient who presented with a torn native valve. Acute hemodynamic and angiographic results showed no residual gradient, mild (three patients) or severe (two patients) aortic regurgitation, and patent coronary arteries. On echocardiography, the aortic valve area was increased from 0.5 +/- 0.1 cm(2) to 1.70 +/- 0.03 cm(2) and the aortic regurgitation was paravalvular. Marked and sustained hemodynamic and clinical improvement was observed after successful PHV implants. The first three patients died of a non-cardiac cause at 18, 4, and 2 weeks, respectively, and the other patients are alive at 8 weeks with no signs of heart failure. CONCLUSIONS: Implantation of the PHV can be achieved in patients with end-stage calcific aortic stenosis and might become an important therapeutic option for patients not amenable to surgical valve replacement.

Aged↗

Choosing a prosthetic heart valve.

Although most of the available prosthetic heart valves function remarkably well, the variety of available choices attests to the inability of any single one to fulfill the requirements of the ideal valve substitute. The mechanical prostheses include the caged-ball, tilting-disc, and bileaflet valves. Tissue valves available in the United States are the Carpentier-Edwards and Hancock porcine heterograft valves and the Carpentier-Edwards pericardial valve. Review of several large comparative studies on valve performance reveals that the overall results with tissue and mechanical valves are about equal at the end of 10 years. The characteristics of each type of valve substitute dictate the selection of one prosthesis in preference to others for a particular patient. Mechanical prostheses are recommended for patients without contraindications for anticoagulants. Tissue valves are reserved for patients over 65 years of age or for patients in whom anticoagulation is contraindicated. Multiple other patient-related factors need to be considered in selecting the appropriate valve, including the psychosocial situation and patient preference.

Biocompatible Materials↗

Application of tissue-engineering principles toward the development of a semilunar heart valve substitute.

Heart valve disease is a significant medical problem worldwide. Current treatment for heart valve disease is heart valve replacement. State of the art replacement heart valves are less than ideal and are associated with significant complications. Using the basic principles of tissue engineering, promising alternatives to current replacement heart valves are being developed. Significant progress has been made in the development of a tissue-engineered semilunar heart valve substitute. Advancements include the development of different potential cell sources and cell-seeding techniques; advancements in matrix and scaffold development and in polymer chemistry fabrication; and the development of a variety of bioreactors, which are biomimetic devices used to modulate the development of tissue-engineered neotissue in vitro through the application of biochemical and biomechanical stimuli. This review addresses the need for a tissue-engineered alternative to the current heart valve replacement options. The basics of heart valve structure and function, heart valve disease, and currently available heart valve replacements are discussed. The last 10 years of investigation into a tissue-engineered heart valve as well as current developments are reviewed. Finally, the early clinical applications of cardiovascular tissue engineering are presented.

Animals↗

Artificial Valve Endocarditis Reduction Trial (AVERT): protocol of a multicenter randomized trial.

BACKGROUND AND AIM OF THE STUDY: This article presents the protocol of the Artificial Valve Endocarditis Reduction Trial (AVERT), a multicenter, international randomized trial to assess the efficacy of the SilzoneTM coating of St. Jude Medical Masters Series mechanical heart valves in the prevention of prosthetic heart valve endocarditis (PVE). A total of 4,400 eligible patients will be randomized within three years of study commencement at 17 participating clinical centers in North America and Europe, with study completion within four years. ELIGIBILITY CRITERIA: Eligible patients are candidates for St. Jude mechanical valves with either the Silzone or conventional cuff, in the mitral and/or aortic position, who give informed written consent to participate. Major exclusion criteria are the presence of prosthetic valves that do not require replacement, and the need for tricuspid valve replacement. Bypass surgery and valve repair are allowed during the implant operation. Patients will be randomized using an envelope-based intraoperative randomization scheme, stratified by clinical center and by the presence of endocarditis at the time of surgery. FOLLOW UP: Patients will be contacted at discharge, three months, and each anniversary of the implant procedure. A brief follow up survey, administered via clinic interview, telephone or mail, will elicit events associated with possible endocarditis (unexplained fever, worsening angina, hospitalization) that will initiate contact with the patient's following physician. OUTCOME ANALYSIS: The primary PVE endpoint will be based upon a published algorithm, with two infectious disease specialists making the final determination of cases classified as possible endocarditis. Study data will be periodically reviewed by a Data Safety Monitoring Board. The primary analysis will be an intention-to-treat comparison of freedom from PVE curves between the Silzone and conventional cuff treatment groups. CONCLUSIONS: AVERT will provide much-needed information on the effectiveness of Silzone in preventing PVE, as well as practice patterns and outcomes of valve replacement.

Clinical Protocols↗

[Surgery of the heart valves: prosthetic replacement versus repair (1)].

The surgical management of valvular heart disease nowadays includes the use of various valvular substitutes and sophisticated reparative surgical techniques. Characteristics and indications of these different surgical options are discussed and the objective criteria that justify the use of a given technique in a given clinical situation are provided.

Aortic Valve↗

Heart valve tissue engineering.

Valvular heart disease is a significant cause of morbidity and mortality world-wide. Classical replacement surgery involves the implantation of mechanical valves or biological valves (xeno- or homografts). Tissue engineering of heart valves represents a new experimental concept to improve current modes of therapy in valvular heart surgery. Various approaches have been developed differing either in the choice of scaffold (synthetic biodegradable polymers, decellularised xeno- or homografts) or cell source for the production of living tissue (vascular derived cells, bone marrow cells or progenitor cells from the peripheral blood). The use of autologous bone marrow cells in combination with synthetic biodegradable scaffolds bears advantages over other tissue engineering approaches: it is safe, it leads to complete autologous prostheses and the cells are more easily obtained in the clinical routine. Even though we demonstrated the feasibility to construct living functional tissue engineered heart valves from human bone marrow cells, so far their general potential to differentiate into non-hematopoietic cell lineages is not fully exploited for tissue engineering applications.

Absorbable Implants↗

Heart valve replacement: which valve for which patient?

The ideal heart valve substitute would show no deterioration or thrombogenicity, offer no resistance to blood flow, and be easy to implant. However, such a valve does not exist and we must accept compromises in some of these qualities based on our patients' needs. In selection of cardiac valve prosthesis, valve-related factors such as durability, thrombogenicity, and fluid dynamics should be carefully matched to patient-related factors such as age, size, life expectancy, comorbidities, plans for pregnancy, and lifestyle. In addition, surgeon- or operation-related factors should be considered. Technical aspects of implantation, ease of reoperation, and operative mortalities may tip the risk and benefit balance in a particular direction. We review currently available heart valve prostheses and the clinical factors that are involved in selection of a heart valve substitute.

Age Factors↗