PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Hip arthroplasty”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Persistent non-specific FDG uptake on PET imaging following hip arthroplasty.

Hip arthroplasty is a common surgical procedure, but the diagnosis of infection associated with hip arthroplasty remains challenging. Fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) has been shown to be a promising imaging modality in settings where infection is suspected. However, inflammatory reaction to surgery can result in increased FDG uptake at various anatomic locations, which may erroneously be interpreted as sites of infection. The purpose of this study was to assess the patterns and time course of FDG accumulation following total hip replacement over an extended period of time. Firstly, in a prospective study nine patients with total hip replacement were investigated to determine the patterns of FDG uptake over time. Three FDG-PET scans were performed in each patient at about 3, 6 and 12 months post arthroplasty. Secondly, in a retrospective analysis, the medical and surgical history and FDG-PET imaging results of 710 patients who had undergone whole-body scans for the evaluation of possible malignant disorders were reviewed. The history of arthroplasty and FDG-PET findings in the hip region were reviewed for this study. Patients with symptomatic arthroplasties or related complaints during FDG-PET scanning were excluded from the analysis. During the entire study period, all nine patients enrolled in the prospective study were demonstrated to have increased FDG uptake around the femoral head or neck portion of the prosthesis that extended to the soft tissues surrounding the femur. Among the patients reviewed in the retrospective study, 18 patients with a history of 21 hip arthroplasties who were asymptomatic at the time of FDG-PET scan met the criteria for inclusion. The time interval between the hip arthroplasty and the FDG-PET study ranged from 3 months to 288 months (mean+/-SD: 80.4+/-86.2 months). In 81% (17 of 21) of these prostheses, increased FDG uptake could be noted around the femoral head or neck portion of the prosthesis. The average time interval between arthroplasty and FDG-PET scan in these patients was 71.3 months. In only four prostheses (19%, 4 of 21) was no abnormally increased FDG uptake seen around the prostheses or adjacent sites. The average time interval in these patients was 114.8 months. It is concluded that following hip arthroplasty, non-specifically increased FDG uptake around the head or neck of the prosthesis persists for many years, even in patients without any complications. Therefore, to minimize the number of false-positive results for infection with PET studies obtained to evaluate a painful hip prosthesis, caution should be exercised when interpreting FDG uptake around the head or neck portion of the prosthesis.

Arthroplasty, Replacement, Hip↗

[Heart arrest in cemented hip arthroplasty].

Hip arthroplasty is a common surgical intervention in our hospital practice, involving high perioperative risk related to patients age and multiple concomitant diseases. Hemodynamic complications described vary from slight hypotension during surgery to heart failure and sudden death, particularly if the operation involves a cemented femoral component. Because of the type of patients undergoing such operations (elderly patients, with osteoporosis and scarce cardiopulmonary reserve), the unclear origin of complications and the lack of consensus on what constitutes adequate monitoring during surgery, hip arthroplasty is problematic for the specialists involved. We report on five deaths during cemented hip arthroplasty; after reviewing the case history and autopsy report of one, we believe the events leading to death were triggered by massive pulmonary embolism.

Aged↗

Gait analysis of patients with resurfacing hip arthroplasty compared with hip osteoarthritis and standard total hip arthroplasty.

Patients with standard total hip arthroplasties may have reduced hip abduction and extension moments when compared with normal nonosteoarthritic hips. In comparison, patients after resurfacing total hip arthroplasty appear to have a near-normal gait. The authors evaluated temporal-spatial parameters, hip kinematics, and kinetics in hip resurfacing patients compared with patients with unilateral osteoarthritic hips and unilateral standard total hip arthroplasties. Patients with resurfacing walked faster (average 1.26 m/s) and were comparable with normals. There were no significant differences in hip abductor and extensor moments of patients with resurfacing compared with patients in the standard hip arthroplasty group. This study showed more normal hip kinematics and functionality in resurfacing hip arthroplasty, which may be due to the large femoral head.

Adult↗

Success rate of modular component exchange for the treatment of an unstable total hip arthroplasty.

Hip instability is the leading cause of morbidity after total hip arthroplasty. Surgical strategies that have been used to eliminate recurrent instability include component revision, trochanteric advancement, or the use of constrained components. Between 1986 and 1997, 731 revision total hip arthroplasties were performed at our institution. A total of 29 patients underwent modular component exchange to treat hip instability. After revision surgery, 16 of 29 (55%) patients experienced redislocation. Nine (31% overall) patients dislocated repeatedly after modular component exchange. Five of the 9 patients who dislocated repeatedly (17% overall) ultimately required rerevision to obtain stability. Modular component exchange is an unpredictable procedure in definitively solving hip stability problems. The limitations of this procedure in treating this complex multifactorial problem must be understood by patient and surgeon alike.

Adult↗

Comparison of offset in Birmingham hip resurfacing and hybrid total hip arthroplasty.

Hip resurfacing is being performed more frequently in the United Kingdom. The possible benefits include more accurate restoration of leg length, femoral offset and femoral anteversion than occurs after total hip arthroplasty (THA). We compared anteroposterior radiographs from 26 patients who had undergone hybrid THA (uncemented cup/cemented stem), with 28 who had undergone Birmingham Hip Resurfacing arthroplasty (BHR). We measured the femoral offset, femoral length, acetabular offset and acetabular height with reference to the normal contralateral hip. The data were analysed by paired t-tests. There was a significant reduction in femoral offset (p = 0.0004) and increase in length (p = 0.001) in the BHR group. In the THA group, there was a significant reduction in acetabular offset (p = 0.0003), but femoral offset and overall hip length were restored accurately. We conclude that hip resurfacing does not restore hip mechanics as accurately as THA.

Acetabulum↗

Bipolar versus total hip arthroplasty for hip osteonecrosis in the same patient.

The authors studied 28 patients with bilateral avascular necrosis of the femoral head who were treated with a cementless bipolar endoprosthesis in one hip and cementless total hip arthroplasty in the other. All the hips selected for bipolar endoprostheses were classified as having avascular necrosis of the femoral head Ficat Stage III, and all the hips selected for total hip arthroplasty were classified as having Ficat Stage IV avascular necrosis. After a midterm followup of an average of 6.4 years (range, 4-12 years), 24 of 28 hips that received bipolar endoprostheses were considered satisfactory, whereas 23 of 28 hips in which an arthroplasty was done were considered satisfactory. After a followup of more than 6 years, the cartilaginous space of the acetabulum could be preserved in 25 hips (89.3%) that received a bipolar endoprosthesis. There were no statistical differences in both groups in terms of clinical result, thigh pain, groin pain, osteolysis, dislocation, and revision rate. Total hip arthroplasty is not the preferred treatment for all patients with hip osteonecrosis. In young patients with Ficat Stage III osteonecrosis with Grade 0 or Grade I cartilage, the use of a cementless bipolar endoprosthesis with a bone ingrowth stem may be considered as an alternative to total hip arthroplasty.

Adult↗

Treatment outcome of two-stage revision total hip arthroplasty for infected hip arthroplasty using antibiotic-impregnated cement spacer.

Infected hip prosthesis, a serious complication of primary total hip arthroplasty (THA), can have severe consequences. We report the treatment outcome of two-stage revision THA for infected hip arthroplasty, including hemiarthroplasty, using an antibiotic-impregnated cement spacer for the interval between the first and second stages. Between 1996 and 2000 we performed this procedure on nine hips in eight patients. Cementless revision THA was performed as the second-stage procedure. Bone defects were restored with frozen allografts. The outcome was evaluated using the hip score of the Japanese Orthopaedic Association (JOA hip score). The mean duration of follow-up was 35.7 months (range 10-55 months). The mean JOA hip score at follow-up improved from 30.1 (range 10-74) to 73.2 (24-96). The mean interval between the first and second stages was 10.1 weeks (range 6-19 weeks). Eight of the nine hips achieved a successful outcome. One hip, with methicillin-resistant Staphylococcus aureus infection, experienced recurrence 4 months after revision THA. This patient was successfully treated 14 months after the first revision THA with a second two-stage procedure using a vancomycin- and arbekacin-impregnated cement spacer and beads. These results suggest that two-stage revision THA using an antibiotic-impregnated cement spacer is a useful technique for treating infected hip arthroplasty.

Aged↗

AAEM case report 32: nerve injury associated with hip arthroplasty.

Hip Arthroplasty to alleviate pain related to arthritic degeneration has become one of the most common orthopedic procedures performed. As the elderly population expands, the number of such procedures can be expected to continue to increase. An electrodiagnostic evaluation can aid in localization, help identify the mechanism of injury, and be used as a tool to identify the nature and severity of the nerve pathology. Electrodiagnosis can also be used to generate a prognosis for recovery from nerve damage following hip surgery.

Arthroplasty, Replacement, Hip↗

Dislocation after total hip arthroplasty.

Hip dislocation has long been one of the major complications after total hip arthroplasty (THA). From 1980 to 1994, we performed 2728 THAs (including primary and revision cases). There were 97 hips (3. 6%) with the complication of dislocation, 62 of which were followed up for at least 2 years (mean 5.3 years; range 2-12 years). Single dislocations occurred in 40% and recurrent dislocations in 60%. More than half of the dislocations (58%) occurred within 3 months after the index operation. The dislocation rate was not related to sex, age, previous revision surgery, or types of prosthesis, but was related to a smaller size of the femoral head. The rate of recurrent dislocation was not related to a history of previous surgery, but was related to a smaller femoral head, late onset of dislocation (> 3 months), soft-tissue imbalance, and cup malposition in both anteversion and inclination. If the size of the femoral head was 26 mm or smaller, a posterior approach was not recommended. Closed reduction followed by 1-2 weeks of skin traction was the treatment of choice. The success rate for the first attempt at closed reduction for the treatment of dislocation was 41%; the success rate decreased gradually with the number of attempts. For the recurrent dislocation group, bracing for 4-6 weeks with training was recommended for the postural type and bracing for 3 months with muscle training for the soft-tissue imbalance type. Only 15% of the dislocated hips needed re-operation, and most of the patients resolved the problem after being informed and undergoing muscle training.

Age Distribution↗

Revision total hip arthroplasty in hip joints with metallosis: a single-center experience with 31 cases.

Clinical and radiographic findings of metallosis in relation to the clinical outcome of revision total hip arthroplasty were analyzed for 31 hips. Causes of metallosis were dissociation of polyethylene liner in 24 hips, catastrophic wear in 6, and the screw used for stem fixation in 1. Metallosis was grade I in 12 hips, grade II in 7, and grade III in 12. Osteolysis around the acetabular cup was observed in 24 (77.4%) of 31 hips. At the time of final follow-up evaluation, none of the hips showed osteolysis, acetabular cup migration, or any change in inclination. Although metallosis could not be completely eradicated in severe cases, the clinical outcome for these hips was favorable. This study demonstrates that metallosis frequently causes osteolysis and that complete elimination of it is not a prerequisite for the success of revision total hip arthroplasty.

Adult↗

[Results of cementless hip arthroplasty].

Hip arthroplasty is performed nowadays according to the needs of the patients irrespective of their age. Tapered rectangular stems for cementless fixation are chosen in most cases in central Europe. They provide primary stability by press-fit implantation into a precisely rasped osseous bed and secondary stability by bone ingrowth into the highly biocompatible titanium alloy with a microrough surface. The 10-year survival of such devices is 92%. Typical radiographic patterns include cortical atrophy and radiolucent lines in Gruen zones 1 and 7. They are due to stress shielding with these distally fixed implants. The number one reason for revision is polyethylene wear and subsequent osteolysis. Metal-on-metal and ceramic-on-ceramic bearings show less wear but osteolysis continues to be a problem.

Austria↗

Prognostic factors influencing the functional outcome of total hip arthroplasty for hip infection sequelae.

To investigate factors influencing functional prognosis for patients who have undergone total hip arthroplasty for late sequelae of infective arthritis of the hip, we conducted a retrospective analysis of 75 hips. All patients had had pyogenic or tuberculous infection and later underwent total hip arthroplasty. The average follow-up period was 5.8 years (range, 3-9 years). Various clinical and radiographic measures were analyzed with respect to Harris hip scores. Younger age at the time of infection onset, preoperative leg length discrepancy greater than 1 in, fusion, severe femoral hypoplasia, and severe acetabular dysplasia were associated with poorer prognosis. The complication rate, including 1 recurrent infection, was relatively low. Previous infections seemed to predict poorer results mostly because of the consequences of infection for the development of the hip joint, rather than because of infection recurrence.

Acetabulum↗

The superolateral approach for aspiration of total hip arthroplasties.

Hip aspiration for exclusion of infection is a common procedure prior to revision arthroplasty. Some patients with total hip arthroplasties develop superomedial migration of the prosthesis, while others can have extensive heterotopic bone formation. The traditional approaches may be contraindicated due to overlying bowel or bone anterior/lateral to the prosthesis. These patients are candidates for the superolateral approach. With the patient supine marks are made on the skin at (i) the greater trochanter and (ii) a superior site that aligns with the neck of the prosthesis and soft-tissue window. The needle enters the lateral skin parallel to the table top. Usually only one pass is necessary.

Arthroplasty, Replacement, Hip↗

Comparison of function two years after revision of failed total hip arthroplasty and primary hip arthroplasty.

Because of the known high complication rate, it is important for both the patient and physician to know as much as possible about the outcome of revision operations for loosened total hip arthroplasties. This study evaluates the changes in subjective ratings and objective kinesiologic measurements from before revision operations through two years after revision operations. The object is to compare these measurements with the measurements of a group of patients with primary replacements. Both groups of patients showed significant improvement in most parameters from before to after surgery. These parameters included walking performance, hip muscle strength, range of motion, forces applied to canes, and the amount of weight borne on the operated limb during quiet standing. Compared to the control group with primary replacements, the group with revision used more assistive devices, had less pain relief, walked slower, had less hip motion, and had more lateral lurch. While results after revision surgery were not as gratifying as those after primary hip replacement, patients requiring revision can still anticipate substantial improvement.

Adult↗

A-W glass ceramic as a bone substitute in cemented hip arthroplasty: 15 hips followed 2-10 years.

We retrospectively reviewed hip arthroplasties in 13 patients (15 hips), in whom we had used apatite-wollastonite (A-W) glass ceramic together with auto- or allograft for augmentation of severe bone deficiency. 11 cemented sockets and 4 stem revisions were included and followed for 2-9.6 years. There were no radiolucent lines between A-W glass ceramic and surrounding bone, and remodeling of the bone graft containing A-W glass ceramic was observed. No migration of cemented sockets was seen except in 1 case, which was revised. In this case, direct bonding between bone and A-W glass ceramic granules was present histologically. In 4 stem revisions, 5 mm subsidence occurred in 1 case. However, the stem became stable and remodeling of the grafted bone occurred. An artificial bone material, such as A-W glass ceramic, can be used under high-load conditions, because of its good mechanical properties.

Adult↗

Modular cementless total hip arthroplasty for hip infection sequelae.

Childhood hip infection may produce significant anatomical deformations leading to the premature onset of secondary osteoarthritis. Total hip arthroplasty (THA) in these patient populations can be technically challenging and has been associated with high complication rates. This article reports the results of 58 cementless THAs with use of a modern implant design. The complication rate, including one recurrent infection, was relatively low. Cementless THA with use of a modular stem coupled with a metal-backed socket was found to be an effective and reliable treatment option for patients with the late sequelae of infective hip arthritis.

Adolescent↗

A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty.

Hip simulator studies show that the wear of ultra-high molecular weight polyethylene against a cobalt alloy head depends on the wear path, especially the combination of a predominantly linear wear direction on which is superimposed motions in different directions. We postulated that multidirectional motion was necessary to generate realistic wear rates in pin-on-disk testing. To assess this hypothesis, a new pin-on-disk tester was developed, capable of unidirectional and bidirectional motion. Unidirectional motion produced no detectable wear. The rectangular motion produced wear rates, surface morphologies, and wear particles consistent with human acetabular specimens. The results for 1 Hz and 2 Hz were similar.

Chromium Alloys↗

Registration in the danish hip arthroplasty registry: completeness of total hip arthroplasties and positive predictive value of registered diagnosis and postoperative complications.

BACKGROUND: There are few publications regarding the validity of data in hip arthroplasty registers. The Danish Hip Arthroplasty Registry (DHR) is a nationwide clinical database of THAs and revisions in Denmark. PATIENTS AND METHODS: We assessed the completeness of registration of primary total hip arthroplasties (THAs) and revisions in the DHR from 1995-2000. In addition, the positive predictive value (PPV) of registered data for diagnoses in patients undergoing primary THA and postoperative complications was analyzed. Completeness was assessed using the Danish National Registry of Patients (NRP) as a reference, which is a nationwide and population-based registry of all somatic hospital admissions since 1977. The positive predictive value of registered data was assessed by review of medical records and preoperative radiographs from samples of randomly selected patients registered in the DHR using a standardized form. RESULTS: The overall completeness of registration for primary THAs and/or revisions was 94% (26,129 patients registered in both NRP and DHR and 27,757 patients registered in the NRP). There was a lower degree of completeness for revisions than for primary THAs (81% versus 94%). The completeness did not vary substantially according to gender and age. Completeness of registration was lower for university hospitals than for other hospitals (91% versus 95%), and for low-volume hospitals (87%) relative to those with medium (92%) and high volumes (96%). Overall, the diagnoses in patients undergoing primary THA could be confirmed in 84% (387/459) of the patients who were reviewed. The diagnosis of fresh fracture of the proximal femur was confirmed in only one third (22/73) of the cases. Postoperative complications were confirmed in two-thirds (36/54) of the patients reviewed. The specificity of the registration of postoperative complications was, however, only one-third (8/26). INTERPRETATION: We conclude that the Danish Hip Arthroplasty Registry is a potentially valuable tool for quality improvement and research due to the high degree of completeness of registrations regarding THA, and its moderate-to-high positive predictive value of registration for diagnoses in patients undergoing primary THA. However, information on several diagnoses for primary THA and on postoperative complications should be used with caution.

Aged↗