PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “IONS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Dynamic ion-ion and water-ion interactions in ion channels.

The dynamic interactions among ions and water molecules in ion channels are treated based on an assumption that ions at binding sites can be knocked off by both transient entering ions and local water molecules. The theory, when applied to a single-site model K+ channel, provides solutions for super- and subsaturations, flux-ratio exponent (n') greater than 1, osmotic streaming current, activity-dependent reversal potentials, and anomalous mole-fraction behavior. The analysis predicts that: (a) the saturation may but, in general, does not follow the Michaelis-Menten relation; (b) streaming current results from imbalanced water-ion knock-off interactions; (c) n' greater than 1 even for single-site channels, but it is unlikely to exceed 1.4 unless the pore is occupied by one or more ion(s); (d) in the calculation involving two permeant ion species with similar radii, the heavier ions show higher affinity; the ion-ion knock-off dissociation from the site is more effective when two interacting ions are identical. Therefore, the "multi-ion behaviors" found in most ion channels are the consequences of dynamic ion-ion and water-ion interactions. The presence of these interactions does not require two or more binding sites in channels.

Binding Sites↗

Enhancing effect of nickel ions on the response to magnesium ions of single fibers of the frog glossopharyngeal nerve: competitive inhibition by calcium ions of the nickel-enhanced response to magnesium ions.

Single fibers of the frog glossopharyngeal nerve respond to MgCl2 at concentrations exceeding 10 mM. NiCl2 at 1 mM enhanced the Mg2+ response. CaCl2 at 0.5-2 mM induced an inhibition of the Ni(2+)-enhanced response to Mg2+ ions. A quantitative explanation for these results is provided by the hypothesis that Ni2+ ions secondarily affect a magnesium receptor (designated X*Mg) that is responsible for the Mg2+ response and that Ca2+ ions inhibit the Ni(2+)-enhanced response to Mg2+ ions by competing with Mg2+ ions for X*Mg. Double-reciprocal plots of the experimental data indicate that Ni2+ ions do not affect the affinities of X*Mg for both Mg2+ ions (agonist) and Ca2+ ions (competitive antagonist) appreciably, and that Ni2+ ions at 1 mM enhanced the maximal response to Mg2+ ions by 270%. It appears that a magnesium receptor interacts with an Ni(2+)-binding element that is affected by Ni2+ ions and, thus, Ni2+ ions can induce an enhancement of the Mg2+ response.

Animals↗

Impact of ion cloud densities on the measurement of relative ion abundances in Fourier transform ion cyclotron resonance mass spectrometry: experimental observations of coulombically induced cyclotron radius perturbations and ion cloud dephasing rates.

Fundamental research into the quantitative properties of Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) has yielded interesting observations, especially in terms of factors affecting the accuracy of relative ion abundances. However, most of the previous discussions have focused on theoretical systems, or systems of limited scope. In this paper, we document ion motion attributes of a 30 spectra (six samples, five replicates each) system previously established as linear over two orders of magnitude. Observed behaviors include the perturbation of one charged species (cyclosporin A, CsA) of low ion density to a cyclotron orbit of greater radius than that of an almost identical, but slightly mass-separated species (CsG) with a higher ion density. This radial perturbation is attributed to the coulombic repulsion between the two ion clouds as they interact during the excitation process, as previously proposed by Uechi and Dunbar. Magnitudes of the perturbation were confirmed by making cyclotron radii determinations utilizing the ratio of the third-to-first harmonics for the charged species of interest. It was found that these radial differences can account for as much as a 55% signal bias in favor of CsA for a single sample and a >20% positive bias in the slope of the regressed data set. A second behavior noted that also contributes to the potential inaccuracy of relative ion abundance measurements is the difference in signal decay rates for CsA and CsG. Damping constants and initial time domain signal amplitudes were evaluated using segmented Fourier transforms. Discrepancies in decay rates were not expected from two species that have essentially identical collisional cross-sections. However, it has been observed that the faster decay rates are observed by the species of lower ion cloud density. We have attributed this differential signal decay phenomenon to the rates of loss of phase coherence for the two ion clouds. Previously, others have reported that less dense ion clouds are more susceptible to shearing and other disruptive forces during the course of their excited cyclotron motion. Our experimental evidence supports that it is the loss of cloud coherence that accounts for the signal loss over time, with the less dense cloud de-phasing more quickly. As the ion populations of the two investigated species near equivalence, so do their time constants.

Cyclosporine↗

A quantitative study of the enhancing effect of nickel ions on the taste response to sodium ions of single fibers of the frog glossopharyngeal nerve: competitive inhibition by calcium ions of the nickel-enhanced response to sodium ions.

Single water fibers of the frog glossopharyngeal nerve respond to relatively high concentrations of NaCl ( > 80 mM). NiCl2 at 1 mM enhanced the Na+ response and reduced the threshold concentration for NaCl to 20 mM. CaCl2 at 0.5-1 mM induced an inhibition of the Ni2+ -enhanced response to Na+ ions. A quantitative explanations for these results is provided by the hypothesis that Ni2+ ions secondarily affect a sodium receptor or channel (designated XNa*) that is responsible for the Na+ response and that Ca2+ ions inhibit the Ni2+ -enhanced response to Na+ ions by competing with Na+ ions for XNa*. Double-reciprocal plots of the experimental data indicate that the affinity of XNa* for both Na+ ions (agonist) and Ca2+ ions (competitive antagonist) in the presence of 1 mM NiCl2 was five times higher than the previously reported values obtained in the absence of NiCl2 (Kitada, 1991). Ni2+ ions at 1 mM enhanced the maximal response to Na+ ions by 190%. It appears that a sodium receptor (or channel) interacts with a Ni2+ -binding element that is affected by Ni2+ ions and, thus, Ni2+ ions can induce both an increase in the affinity of the sodium receptor for the respective cations and an enhancement of the Na+ response.

Animals↗

Coupling of chromatographic ion-exchange reaction with change-partner reaction. Presumed mechanism on the ion-ion interaction of inorganic ions in Sephadex G-15 columns.

A sample solution containing sodium or potassium dihydrogenphosphate or disodium or dipotassium hydrogenphosphate was eluted from a Sephadex G-15 column with either sodium or potassium chloride solution in various sample-eluent systems, and every one of the four kinds of ions employed was determined in the eluate. Then, the elution profiles showed the phenomenon that a negative peak of chloride ion coexisted in the fractions of a positive peak of phosphate ion, in all sample-eluent systems employed. This phenomenon was assumed to occur by the coupled reaction of change-partner and ion-exchange reactions including ion exclusion.

Chromatography, Ion Exchange↗

Radial stratification of ions as a function of mass to charge ratio in collisional cooling radio frequency multipoles used as ion guides or ion traps.

Collisional cooling in radio frequency (RF) ion guides has been used in mass spectrometry as an intermediate step during the transport of ions from high pressure regions of an ion source into high vacuum regions of a mass analyzer. Such collisional cooling devices are also increasingly used as 'linear', two-dimensional (2D) ion traps for ion storage and accumulation to achieve improved sensitivity and dynamic range. We have used the effective potential approach to study m/z dependent distribution of ions in the devices. Relationships obtained for the ideal 2D multipole demonstrate that after cooling the ion cloud forms concentric cylindrical layers, each of them composed of ions having the same m/z ratio; the higher the m/z, the larger is the radial position occupied by the ions. This behavior results from the fact that the effective RF focusing is stronger for ions of lower m/z, pushing these ions closer to the axis. Radial boundaries of the layers are more distinct for multiply charged ions, compared to singly charged ions having the same m/z and charge density. In the case of sufficiently high ion density and low ion kinetic energy, we show that each m/z layer is separated from its nearest neighbor by a radial gap of low ion density. The radial gaps of low ion population between the layers are formed due to the space charge repulsion. Conditions for establishing the m/z stratified structure include sufficiently high charge density and adequate collisional relaxation. These conditions are likely to occur in collisional RF multipoles operated as ion guides or 2D ion traps for external ion accumulation. When linear ion density increases, the maximum ion cloud radius also increases, and outer layers of high m/z ions approach the multipole rods and may be ejected. This 'overfilling' of the multipole capacity results in a strong discrimination against high m/z ions. A relationship is reported for the maximum linear ion density of a multipole that is not overfilled.

Algorithms↗

Tandem mass spectra of ammonium ion, metal ion and ligated metal ion adducts of acyclic sugar derivatives.

The tandem mass (MS/MS) spectra of ammonium ion, metal ion and ligated metal ion adducts of chain-extended acyclic nitro-containing deoxyglucose and deoxygalactose derivatives have been studied. The ammonium adducts fragment primarily by elimination of ammonia followed by acetic acid, thus not giving much structural information. In contrast, cationization of these compounds by metal ions and ligated metal ions gave structurally informative and useful fragment ions on MS/MS. The metal ions and ligated metal ions play an important role in controlling and directing fragmentation. Retro-aldol fragmentation is facilitated by metal ions such as Li(+), Na(+), Ag(+) and Cu(+), whereas the adducts with higher alkali metal ions such as Rb(+) and Cs(+) fragment to give only the corresponding metal ions. The divalent metal ions such as Cu(2+) and Ba(2+) also induce retro-aldol fragmentation. However, the charge is carried by the aldehyde fragment in the case of Cu(2+) adducts, whereas the nitroalkane fragment carries the charge in the case of Ba(2+) adducts. Ligated metal ions such as ZnCl(+), CuCl(+), InCl(2) (+) and BaCl(+) also behave similarly and induce retro-aldol fragmentation in these acyclic sugars. Both the metal ion and ligated metal ion adducts can fragment by elimination of metal-containing neutral molecules.

Acetic Acid↗

Origin of mass shifts in the quadrupole ion trap: dissociation of fragile ions observed with a hybrid ion trap/mass filter instrument

A novel hybrid tandem mass analyzer, coupling a quadrupole ion trap with a quadrupole mass filter, has been constructed to permit mass analysis of ions ejected from the ion trap. The initial application of this instrument is the investigation of the origin of mass shifts in the ion trap due to ion fragility. We hypothesize that fragile ions undergo mass shifts, characterized by peak fronting, due to early ejection from the quadrupole ion trap. As these ions come into resonance with the ejection frequency, they gain kinetic energy, collide with buffer gas molecules and thus can dissociate to produce fragment ions. These fragment ions will not be stable within the ion trap as they are situated past the stability boundary at q(z) = 0. 908. Consequently the fragment ions are ejected prematurely. This results in an apparent mass shift due to peak fronting. The experiments reported here clearly document the production of fragment ions as the origin of mass shifts during the resonant ejection of fragile ions. Copyright 2000 John Wiley & Sons, Ltd.

Journal Article↗

Investigating the use of an octupole ion guide for ion storage and high-pass mass filtering to improve the quantitative performance of electrospray ion trap mass spectrometry.

An octupole radio frequency (rf) ion guide was evaluated for storage and filtering of ions generated by electrospray prior to introduction into an ion trap mass spectrometer. The control of the rf potential on the ion guide enabled its operation as a high-pass mass filter, removing low-mass chemical noise that would normally fill the ion trap and result in reduced sensitivity, mass resolution, and dynamic range. Also, the ion guide can serve to store the high-pass filtered ions during the ion trap mass analysis, enabling nearly 100% duty cycle and reduction of the cycle time by a factor of two. The linearity, precision, and detection limits of the liquid chromatography (LC) electrospray - ion guide-ion trap MS/MS system were evaluated for the determination of ceftiofur in milk. A linear calibration (linear correlation coefficient of 0.986) from 2-200 ppb was obtained with a relative standard deviation for replicate analysis of less than 8%. A quantitation detection limit of 100 pg of ceftiofur on-column (2 ppb) was achieved from a milk extract. This detection limit is nearly a factor of 10 lower compared with the determination on the same electrospray ion trap system not using a rf ion guide for high-pass mass filtering and ion storage.

Animals↗

A quantitative study of dual action of nickel ions on the taste response to calcium ions of single fibers of the frog glossopharyngeal nerve: inhibition and enhancement by nickel ions.

Unitary discharges from single water fibers of the frog glossopharyngeal nerve, caused by stimulation with 0.02-5 mM CaSO4, were recorded from fungiform papillae with a suction electrode. NiSO4 at concentrations of 0.2-2 mM, namely, at concentrations that are barely effective in producing impulses, had a dual action on the Ca2+ response: NiSO4 caused both inhibition and enhancement of the Ca2+ response. In the present study, this dual action of Ni2+ ions on the Ca2+ response was investigated in detail. Single water fibers yielded a saturation type of concentration-response curve for CaSO4, which suggested that sulfate ions do not affect the Ca2+ response. Thus, sulfates were used as test salts in the present study. At low concentrations of Ca2+ ions, Ni2+ ions inhibited the Ca2+ response, but at higher concentrations of Ca2+ ions they enhanced it. The results can be explained quantitatively by the hypothesis that Ni2+ ions inhibit the Ca2+ response by competing with Ca2+ ions for the Ca2+ receptor (XCa) that is responsible for the Ca2+ response and that Ni2+ ions enhance the Ca2+ response by acting on a membrane element that interacts with XCa. Double-reciprocal plots of the data indicate that the enhancing action of Ni2+ ions is saturated at 1-2 mM Ni2+ ions and that Ni2+ ions at these concentrations increase the maximal response of the Ca2+ response by 182%. Dissociation constants for the Ca-XCa complex and the Ni-XCa complex were 4.2 x 10(-5) M and 7.6 x 10(-5) M, respectively. The analysis suggests that Ni2+ ions enhance the Ca2+ response by affecting the Ca-XCa complex without altering the affinity of XCa for Ca2+ ions.

Animals↗

Product ion spectral simplification using time-delayed fragment ion capture with tandem linear ion traps.

A new technique to generate product ion spectra as the internal energy of a collisionally activated precursor ion evolves is described. The precursor ion is activated by acceleration into a mass-selective linear ion trap under conditions whereby some of the fragment ions formed are unstable within the trap. After a time delay the stability parameters of the ion trap are changed to allow capture of fragments that that were previously unstable. The result is a product ion spectrum that originates from precursor ions with a modified internal energy distribution. It is possible to follow the evolution of the precursor internal energy distribution for many milliseconds after admittance of the precursor ions into the linear ion trap. Time-delayed fragmentation product ion spectra typically display reduced sequential fragmentation products leading to spectra that are more easily interpreted. Several important experimental parameters important to time-delayed fragmentation have been identified and are discussed. The technique has applications for both small precursor ions and multiply charged peptides.

Bosentan↗

A C60 primary ion beam system for time of flight secondary ion mass spectrometry: its development and secondary ion yield characteristics.

A buckminsterfullerene (C60)-based primary ion beam system has been developed for routine application in TOF-SIMS analysis of organic materials. The ion beam system is described, and its performance is characterized. Nanoamp beam currents of C60+ are obtainable in continuous current mode. C60(2+) can be obtained in pulsed mode. At 10 keV, the beam can be focused to less than 3 microm with 0.1 nA currents. TOF-SIMS studies of a series of molecular solids and a number of polymer systems in monolayer and thick film forms are reported. Very significant enhancement of secondary ion yields, particularly at higher mass, were observed using 10-keV C60+ for all samples other than PTFE, as compared to those observed from 10 keV Ga+ primary ions. Three materials (PS2000, Irganox 1010, PET) were studied in detail to investigate primary ion-induced disappearance (damage) cross sections to determine the increase in secondary ion formation efficiency. The C60 disappearance cross sections observed from monolayer film PS2000 and self-supporting PET film are close to those observed from Ga+. The resulting C60 efficiencies are 30-100 times those observed from gallium. The cross sections observed from C60 bombardment of multilayer molecular solids are approximately 100 times less, such that essentially zero damage sputtering is possible. The resulting efficiencies are > 10(3) greater than from gallium. It is also shown that C60 primary ions do not generate any more low-mass fragments than any other ion beam system does. C60 is shown to be a very favorable ion beam system for TOF-SIMS, delivering high yield, close to 10% total yield, favoring high-mass ions, and on thick samples, offering the possibility of analysis well beyond the static limit.

Journal Article↗

Reactions of Charged Substrates. 6. The Methoxymethyl Carbenium Ion Problem. 1. A Semiempirical Study of the Kinetic and Thermodynamic Stabilities of Linear and Cyclic Oxo- and Thiocarbenium Ions Generated from Pyridinium and Dimethylanilinium Ions.

AM1-calculated energy profiles for dissociation of (methoxymethyl)pyridinium and dimethylanilinium ion substrates show that the methoxymethyl carbenium ion is not sufficiently stable to exist as an intermediate on the reaction coordinate for this model reaction. [(Thiomethoxy)methyl]pyridinium ion, however, has a distinct transition state because of the stability of the resulting ion-neutral complex. The complete potential energy surfaces for water displacement on the methoxymethyl substrate with either pyridine or dimethylaniline as the leaving group show distinct transition states and very flat surfaces for the ion-neutral complexes in which interaction of the carbenium ion with both leaving group and nucleophile is stabilizing. Secondary systems studied, including linear methoxy and thiomethoxy substrates, 5- and 6-membered cyclic oxo and thio substrates, and ribosyl-, xylopyranosyl-, and glucopyranosylpyridinium ions yield ion-neutral complexes with sufficient intrinsic stability to exist as intermediates. Comparison with solution data, primarily activation entropy and Brønsted coefficients, suggests that the sugar oxocarbenium ions, either as distinct, solvent-equilibrated intermediates or elements of ion-neutral complexes, are formed by unimolecular dissociation of the respective substrates in solution.

Journal Article↗

Determination of fluoride ions released from resin-based dental materials using ion-selective electrode and ion chromatograph.

OBJECTIVES: The aim of this study was to investigate the quantities of total and free fluoride ions released from four resin-based composites containing fluoride (Heliomolar (HE), UniFil S (UF), Beautifil (BE) and Reactmer paste (RP)) and one glass ionomer cement (Ketac-Fil Plus Aplicap (KF)). METHODS: Five disk specimens of each material were prepared and the fluoride release was measured at 1, 2, 4, 7, 14, 21 and 28 days. The amounts of total and free fluoride ions released from materials were measured by using an ion-selective electrode (ISE) and ion chromatography (IC). Data were statistically analyzed using a t-test at a significant level of 0.05. RESULTS: For HE, fluoride release is undetectable using the ISE but was detected by the IC method. There were no significant differences in the free and total fluoride ions released from UF and BE (p>0.05). For RP, the free fluoride ions were significantly lower than the total fluoride ions after 4 days (p<0.05). KF showed significant difference between total and free fluoride ions at 7 and 28 days (p<0.05). CONCLUSIONS: The nature of the fluoride incorporated into dental materials affected the amounts of free and total fluoride ions released from materials.

Acrylic Resins↗

Metal ions and phosphate binding in the H-N-H motif: crystal structures of the nuclease domain of ColE7/Im7 in complex with a phosphate ion and different divalent metal ions.

H-N-H is a motif found in the nuclease domain of a subfamily of bacteria toxins, including colicin E7, that are capable of cleaving DNA nonspecifically. This H-N-H motif has also been identified in a subfamily of homing endonucleases, which cleave DNA site specifically. To better understand the role of metal ions in the H-N-H motif during DNA hydrolysis, we crystallized the nuclease domain of colicin E7 (nuclease-ColE7) in complex with its inhibitor Im7 in two different crystal forms, and we resolved the structures of EDTA-treated, Zn(2+)-bound and Mn(2+)-bound complexes in the presence of phosphate ions at resolutions of 2.6 A to 2.0 A. This study offers the first determination of the structure of a metal-free and substrate-free enzyme in the H-N-H family. The H-N-H motif contains two antiparallel beta-strands linked to a C-terminal alpha-helix, with a divalent metal ion located in the center. Here we show that the metal-binding sites in the center of the H-N-H motif, for the EDTA-treated and Mg(2+)-soaked complex crystals, were occupied by water molecules, indicating that an alkaline earth metal ion does not reside in the same position as a transition metal ion in the H-N-H motif. However, a Zn(2+) or Mn(2+) ions were observed in the center of the H-N-H motif in cases of Zn(2+) or Mn(2+)-soaked crystals, as confirmed in anomalous difference maps. A phosphate ion was found to bridge between the divalent transition metal ion and His545. Based on these structures and structural comparisons with other nucleases, we suggest a functional role for the divalent transition metal ion in the H-N-H motif in stabilizing the phosphoanion in the transition state during hydrolysis.

Amino Acid Motifs↗

Solvation of acylium fragment ions in electrospray ionization quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry.

In electrospray ionization (ESI) quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry, certain fragment ions (e.g. acylium ions) generated either during the ion transportation process (in the source interface region) or in the ion trap are found to undergo ion--molecule reactions with ESI solvent molecules (water, acetonitrile and aliphatic alcohols) to form adduct species. These unexpected solvated fragment ions severely complicate the interpretation of mass spectrometic data. High-resolution accurate mass measurements are important in establishing the elemental compositions of these adduct species and preventing erroneous data interpretation.

Acetals↗

Ion detection by Fourier transform ion cyclotron resonance: the effect of initial radial velocity on the coherent ion packet.

Ion detection by Fourier transform ion cyclotron resonance (FT-ICR) is accomplished by observing a coherent ion packet produced from an initially random ensemble of ions. The coherent packet is formed by excitation with a resonant oscillating electric field. Ions that are out of phase with the applied radio frequency (rf) electric field experience a continuous misalignment of the electric field vector. The misalignment creates a net force of the electric field perpendicular to ion motion. The perpendicular component of the rf electric field creates a frequency shift resulting in phase synchronization of the ion ensemble. The phase coherence of the ion packet affects both the sensitivity and the resolution of FT-ICR.

Electromagnetic Fields↗