PubMed HealthSearch

SEARCH · PubMed Health

Results for “Imaging, Three-Dimensional”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Assessment of temporomandibular joint space changes after orthognathic surgery in skeletal malocclusion patients: a systematic review.

PURPOSE: To interpret postoperative changes in temporomandibular joint (TMJ) joint space dimensions and condylar position following orthognathic surgery in patients with skeletal malocclusions, and to determine whether reported alterations represent clinically meaningful displacement or physiological adaptive remodeling. MATERIALS AND METHODS: A comprehensive search of PubMed, SCOPUS, Web of Science, EBSCOhost, and Cochrane Library was performed to assess pre- and postoperative TMJ changes using three-dimensional imaging. Joint spaces including anterior (AJS), superior (SJS), and posterior (PJS) and condylar morphology were evaluated. Methodological quality was appraised using the Joanna Briggs Institute (JBI) checklist. Due to methodological and clinical heterogeneity, findings were synthesized narratively with attention to malocclusion type and surgical movement. RESULTS: A total of 16 studies consisting 628 patients undergoing BSSO, Le Fort I osteotomy, vertical ramus osteotomy, or bimaxillary surgery were included. Most studies reported minor, adaptive postoperative changes in AJS, SJS, and PJS. Class II patients showed more consistent increases in AJS/SJS, whereas Class III patients demonstrated variable posterior or anterior remodelling depending on surgical movement. Volumetric analyses revealed region-specific adaptations without significant condylar displacement. Postoperative temporomandibular disorder symptoms were infrequent, and no consistent evidence supported detrimental TMJ effects attributable to surgery. CONCLUSION: Postoperative TMJ joint space changes after orthognathic surgery primarily represent physiological adaptive remodeling rather than pathological condylar displacement, with reported variability driven by malocclusion type, surgical movement, fixation method, and imaging protocol. Recognizing these predictable patterns is essential to prevent overinterpretation of postoperative imaging and to improve clinical assessment through standardized three-dimensional and long-term evaluation strategies.

Humans

Three-Dimensional Fracture Mapping of the Terrible Triad of the Elbow: Morphological Characteristics and Clinical Implications.

BACKGROUND: The morphology of fractures in the terrible triad of the elbow (TTE) is complex, and precise management relies on a profound understanding of this morphology. This study aims to systematically analyze, for the first time, the distribution and morphological characteristics of TTE fracture lines using three-dimensional (3D) imaging technology. METHODS: Clinical data and thin-slice CT scans of 112 patients with TTE from January 2021 to December 2024 were retrospectively included. 3D fracture models were reconstructed using Mimics software. Virtual reduction and standardized alignment were performed using 3-matic software. Fracture lines were mapped onto standard ulnar and radial templates, and 3D fracture heat maps were generated using the E-3D software to demonstrate the high-frequency distribution zones of the fracture lines visually. Statistical analysis was performed using SPSS software (version 21.0, IBM Corp., Armonk, NY, USA). Continuous variables were compared using one-way analysis of variance (ANOVA), and categorical variables were compared using the chi-square test (&#x3c7;2 test). A two-tailed p&#x2009;<&#x2009;0.05 was considered statistically significant. RESULTS: The study revealed distinct patterns in the distribution of TTE fracture lines. In the coronoid process, the fracture "hot zone" presented as an annular high-density band extending from the lateral middle aspect to the tip. In the radial head, an oblique high-density band was observed in the anterolateral quadrant of the articular surface. The radial neck exhibited a circumferential high-density zone, which was most prominent in the anterolateral aspect. Statistical analysis indicated a significant correlation between age and fracture complexity; the proportion of Regan-Morrey type III coronoid fractures and Mason type III radial head fractures was significantly higher in elderly patients (>&#x2009;60&#x2009;years) (p&#x2009;<&#x2009;0.05), suggesting that advanced age is a significant risk factor for complex fractures. CONCLUSION: This study is the first to visually reveal the Collaborative Distribution Patterns of TTE fracture lines using 3D fracture mapping technology. This model provides morphological evidence for understanding the injury mechanism of TTE and offers an anatomical framework that may assist surgeons in individualizing surgical approaches and fixation strategies.

Humans

Volumetric bone marrow cellularity (VBMC) assessment from routinely processed trephines using three-dimensional x-ray histology and gaussian peak modelling.

Objective.Bone marrow cellularity is routinely estimated from a small number of two-dimensional histology sections, making assessment sensitive to section representativeness, processing artefacts and observer interpretation. Three-dimensional (3D) x-ray histology (XRH), using x-ray computed microtomography (&#xb5;CT), enables non-destructive whole-block imaging of trephine biopsies. This study evaluated whether XRH combined with Gaussian peak modelling could provide a pragmatic whole-block volumetric bone marrow cellularity (VBMC) estimate from formalin-fixed paraffin-embedded (FFPE) trephine biopsy blocks.Approach.Six routinely processed FFPE bone marrow trephine blocks were imaged using &#xb5;CT-based XRH at &#x223c;15 &#xb5;m spatial resolution. VBMC was defined as the red-marrow (RM) fraction of the marrow soft-tissue compartment, RM/(RM + intra-biopsy wax), with wax serving as the volumetric proxy for adipocyte/yellow marrow space. Whole-volume greyscale histograms were modelled using a three-peak Gaussian approach representing intra-biopsy wax, RM and demineralised trabecular matrix. Peak-height and area-under-the-curve metrics were compared with whole-volume 3D segmentation and clinical two-dimensional (2D) cellularity estimates.Main Results.Gaussian peak modelling successfully approximated the segmented tissue-phase distributions. The peak-height-derived VBMC metric showed the closest agreement with whole-volume 3D segmentation, with an average absolute percentage difference of 9.3%, compared with 18.6% for clinical expert 2D cellularity estimates. The area-under-the-curve metric followed similar trends but consistently overestimated VBMC. Clinical 2D cellularity broadly followed whole-biopsy trends but showed one discordant case not explained by slice-position sampling alone. XRH also enabled unrestricted virtual reslicing and visualisation of sectioning-associated artefacts prior to further microtomy.Significance.Pre-sectioning XRH combined with Gaussian peak modelling provides a rapid, segmentation-free route to volumetric cellularity estimation from intact clinical FFPE trephine blocks. The approach supports objective whole-biopsy assessment while remaining compatible with routine histopathology workflows, reflecting the expected limitations of section-based visual estimation despite its role as the current clinical standard. In the near term, it could provide a non-disruptive adjunct to conventional 2D cellularity reporting, pending larger validation studies.

Imaging, Three-Dimensional

Higher Rates of PASS and SCB After Arthroscopic Subspine Decompression Are Associated With a Positive Diagnostic AIIS Injection: A Propensity Score-Matched Cohort Study.

BACKGROUND: Hip arthroscopy effectively treats femoroacetabular impingement syndrome (FAIS), but persistent pain may be related to concomitant extra-articular pathology such as subspine impingement syndrome (SSI). Standard diagnosis of SSI often relies on 3-dimensional computed tomography (3D-CT) morphology (Hetsroni type II/III), although this morphology is common in individuals who are asymptomatic and correlates poorly with symptoms. PURPOSE: To compare minimum 2-year clinical outcomes after arthroscopic subspine decompression in patients with concurrent FAIS and type II/III anterior inferior iliac spine (AIIS) morphology, stratified by diagnostic method: 3D-CT morphology alone versus 3D-CT morphology plus a positive ultrasound-guided diagnostic injection. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This study included patients aged 18 to 55 years with type II/III AIIS morphology who underwent primary hip arthroscopy for FAIS and SSI between January 2021 and November 2023 and had minimum 2-year follow-up. Patients diagnosed by CT morphology alone (CT classification group) were propensity score matched 1:1 to patients with a positive ultrasound-guided AIIS injection (injection group), with 57 patients per group. Matching variables were age, sex, body mass index, lateral center-edge angle, alpha angle, T&#xf6;nnis grade, and Beighton score. All patients underwent arthroscopic subspine decompression. Patient-reported outcomes and rates of achieving the minimal clinically important difference, Patient Acceptable Symptom State (PASS), and substantial clinical benefit (SCB) were compared. RESULTS: Preoperative patient-reported outcome scores were similar between groups (all P > .05). At minimum 2-year follow-up, the injection group had significantly better scores on the modified Harris Hip Score (90.8 vs 84.2), Hip Outcome Score-Activities of Daily Living (88.4 vs 82.4), Hip Outcome Score-Sports Subscale (71.9 vs 64.1), 12-item International Hip Outcome Tool (83.9 vs 76.1), and visual analog scale for pain (1.2 vs 2.0) (all P < .001). Minimal clinically important difference rates were high in both groups, with higher rates in the injection group for modified Harris Hip Score (93% vs 77%; P = .033) and Hip Outcome Score-Activities of Daily Living (91% vs 75%; P = .042). PASS and SCB rates were significantly higher in the injection group across all patient-reported outcome measures (all P < .05). Revision and complication rates were low and did not differ significantly between groups. CONCLUSION: Both groups improved significantly after arthroscopic subspine decompression. However, patients with a positive ultrasound-guided diagnostic AIIS injection achieved higher PASS and SCB rates than those selected by CT morphology alone, suggesting that injection-confirmed SSI may improve patient selection for subspine decompression.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Volumetric DNA microscopy for mapping spatial transcriptomes in three dimensions.

The architecture and function of biological systems are inherently three-dimensional, yet most existing spatial transcriptomic technologies remain restricted to thin tissue sections, limiting their capacity to resolve cellular organization and microenvironments within intact tissue volumes. To address this limitation, we developed volumetric DNA microscopy, a scalable, optics-free approach for spatial transcriptome profiling directly within intact biological specimens. The method encodes spatial information into DNA molecules that form a dense intermolecular network in situ, enabling the reconstruction of three-dimensional spatial relationships through short-read sequencing and computational analysis. Here we detail the complete workflow including in situ cDNA synthesis, spatial encoding through DNA nanoball formation, dual-scale proximity bridging between neighboring nanoballs and spatial reconstruction via geodesic spectral embedding. Sequencing libraries can be generated within 7-8 d by a competent graduate-level molecular biologist, followed by standardized downstream computational analysis. Because the workflow requires only routine molecular biology reagents and a benchtop sequencer, volumetric DNA microscopy provides a versatile platform for exploring genetic and morphological features in intact tissues.

Spatial Transcriptomics

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Exploring the Diagnostic Utility of Ferumoxytol for Brachial Plexus MR Neurography.

Background Ferumoxytol has been described as an alternative contrast agent for vascular suppression in MR neurography (MRN), but its diagnostic utility in patients has yet to be evaluated. Purpose To evaluate the impact of ferumoxytol on vascular suppression, nerve conspicuity, and evaluation of nerve abnormalities at three-dimensional (3D) brachial plexus MRN, compared with noncontrast and gadolinium-enhanced MRN, in participants with suspected Parsonage-Turner syndrome (PTS) or thoracic outlet syndrome (TOS). Materials and Methods This prospective study included participants who underwent 3D MRN with and/or without gadolinium chelate for clinical suspicion of PTS or TOS and subsequently underwent 3D MRN with ferumoxytol (within 3 months of the clinical examination). Two musculoskeletal radiologists qualitatively evaluated 3D short-tau inversion-recovery fast spin-echo scans for the degree of vascular suppression, nerve conspicuity, and presence of nerve abnormalities. Wilcoxon signed-rank or McNemar tests were used for comparing noncontrast and gadolinium-enhanced scans with ferumoxytol-enhanced scans. Results This study included 18 participants (mean age, 42 years &#xb1; 15.2 [SD]; 10 men). Ferumoxytol-enhanced scans demonstrated improved vascular suppression compared with both noncontrast scans (both raters, P < .001) and gadolinium-enhanced scans (both P = .04). For rater 2, ferumoxytol-enhanced acquisitions demonstrated improved conspicuity of several nerve segments relative to the noncontrast scan, including segments of the suprascapular (P = .01), axillary (P = .02), and long thoracic nerves (P = .004). The distribution of scores for these nerve segments for rater 1 also favored ferumoxytol-enhanced versus noncontrast scans, but the differences were not statistically significant (all P &#x2265; .06). There was no evidence of a difference in nerve conspicuity between ferumoxytol-enhanced and gadolinium-enhanced scans (P &#x2265; .17 for all nerve segments) and also no evidence of discrepancies in abnormal nerve findings between the acquisitions (all P &#x2265; .48). Conclusion Ferumoxytol improved vascular suppression compared with noncontrast and gadolinium-enhanced 3D short-tau inversion-recovery fast spin-echo sequences in brachial plexus MRN, enhancing the conspicuity of several nerve branches versus noncontrast scans, with similar detection of abnormal nerve findings. &#xa9; RSNA, 2026 Supplemental material is available for this article.

Humans

Recovering membrane interaction kinetics of single molecules from 3D tracking data.

Interactions between cytosolic biomolecules and the bacterial inner membrane are fundamental to many cellular processes, yet directly measuring their binding kinetics in living cells remains challenging. Conventional 2D single-molecule tracking analyses can be insufficient, particularly when membrane association does not markedly alter the diffusion rate. Here, we present a method to recover membrane interaction kinetics from 3D single-molecule trajectories in rod-shaped bacteria. Using simulated 3D tracking data, we identify membrane-associated motion by quantifying how well short trajectory segments follow the circular curvature of the cell membrane. The resulting measure is further analyzed using a hidden Markov modeling framework, enabling robust discrimination between cytosolic and membrane-bound states and capturing the dynamics of state transitions without requiring diffusion-rate changes or direct colocalization with membrane markers. This work establishes a general framework for extracting membrane interaction kinetics from 3D single-molecule tracking data in live bacteria and highlights the value of realistic microscopy simulations for quantitative interpretation and systematic bias assessment.

Kinetics

Test-retest reliability of spatiotemporal, kinematic, and kinetic measures in marker-based 3D gait analysis: A systematic review.

BACKGROUND: Marker-based 3D gait analysis (3DGA) is widely used to quantify impairments and evaluate treatment effects. For longitudinal clinical interpretation, clinicians and researchers need reference values for inter-session measurement error. For this purpose, this systematic review synthesized Standard Error of Measurement (SEM) values for spatiotemporal, kinematic, and kinetic (moments) outcomes obtained from marker-based 3DGA studies. METHODS: PubMed and Scopus were searched (final search: 11 December 2025). Studies reporting inter-session test-retest SEM and/or MDC for steady-state overground or treadmill walking using marker-based motion capture were included. Two authors screened records and appraised methodological/reporting quality using a custom tool informed by COSMIN, GRRAS, and biomechanics-specific items. Due to heterogeneity, results were synthesized descriptively using study-level median SEM values, stratified by joint, plane, population (healthy, pathological, single subgroups), and walking condition. Minimal Detectable Change (MDC) values were computed for all available data. RESULTS: Thirty-four studies (762 participants, 44.2% females) were included, with substantially more evidence for overground than treadmill walking. Overground spatiotemporal outcomes showed low errors (walking speed SEM of 0.06 m/s; timing typically &#x2264;0.03 s; spatial parameters generally &#x2264;0.03 m). For joint kinematics during overground walking, median SEMs were 2.4&#xb0; (sagittal), 1.9&#xb0; (frontal), and 3.3&#xb0; (transverse). The corresponding joint-kinetic SEMs were approximately 0.06, 0.04, and 0.03 Nm/kg, respectively. Treadmill data followed similar patterns. SIGNIFICANCE: Marker-based 3DGA allows for accurate assessment of spatiotemporal, kinematic, and kinetic gait features. We provided detailed SEM/MDC lookup tables to support clinical decision-making. Results further offer a benchmark for validating emerging gait assessment technologies (e.g., markerless systems) against realistic limits of marker-based 3DGA.

Humans

Current Concepts and Emerging Technologies in Aesthetic Outcome Assessment of Breast Reconstruction.

Aesthetic outcomes are a crucial determinant of the overall success of breast reconstruction. Recently, aesthetic assessment has evolved from relying mainly on subjective impressions to incorporating more quantitative methods. This systematic review summarizes current concepts and emerging technologies in aesthetic outcome assessment after breast reconstruction. A comprehensive search of studies evaluating aesthetic outcomes following implant-based, autologous or hybrid breast reconstruction was performed between 2000 and 2025. Assessments were classified as subjective or objective. Extracted variables included assessment characteristics, aesthetic outcome domains, and patient-centered outcomes. Risk of bias was assessed using the Joanna Briggs Institute Critical Appraisal Checklist. Levels of evidence were classified according to the Oxford Centre for Evidence-Based Medicine. A total of 51 studies involving 7711 participants from 16 countries were included. Subjective tools were most frequently employed, led by the BREAST-Q (35/51, 69%), followed by expert- or panel-based evaluations (17/51, 33%) and the visual analog scale (2/51, 4%). Objective methods were applied in 19 studies and included 3-dimensional surface imaging (8/51, 16%), BCCT.core (7/51, 14%), eye tracking (3/51, 6%), and artificial intelligence-based analyses (3/51, 6%). Although subjective tools captured satisfaction with breast appearance, objective tools quantified morphological parameters and positional landmarks. BREAST-Q remains the cornerstone of outcome evaluation after breast reconstruction, providing patient-centered perspectives, including, but not limited to, aesthetic perception. A progressive shift toward multimodal evaluation was noticed, as no single modality comprehensively addressed all aesthetic domains. Future research should focus on integrating subjective and objective assessment methods within a unified framework. Level of Evidence: 3 (Therapeutic) For image description, please refer to the figure legend and surrounding text.

Humans

The Open Microscopy Environment (OME) Data Model and XML file: open tools for informatics and quantitative analysis in biological imaging.

The Open Microscopy Environment (OME) defines a data model and a software implementation to serve as an informatics framework for imaging in biological microscopy experiments, including representation of acquisition parameters, annotations and image analysis results. OME is designed to support high-content cell-based screening as well as traditional image analysis applications. The OME Data Model, expressed in Extensible Markup Language (XML) and realized in a traditional database, is both extensible and self-describing, allowing it to meet emerging imaging and analysis needs.

Computational Biology

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8&#x202f;&#xb1;&#x202f;2.3&#x202f;nm for Cy5 and 13.5&#x202f;&#xb1;&#x202f;2.9&#x202f;nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28&#x202f;nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

Changes in ACL T2* Metrics Over the Course of the Female Menstrual Cycle: A New Biomarker for the ACL Injury Risk?

BACKGROUND: Sex-based disparities in the anterior cruciate ligament (ACL) injury risk may be partly explained by cyclic variations in sex hormones that drive systemic shifts in tissue osmoregulation. Ultrashort echo time (UTE) T2* magnetic resonance imaging provides a noninvasive, quantitative means of evaluating the water content and collagen orientation in tissue. HYPOTHESIS: Eumenorrheic female participants will exhibit significant ACL T2* changes across the cycle, while anovulatory control participants will demonstrate no significant changes over time. STUDY DESIGN: Cohort study; Level of evidence, 2. METHODS: A total of 25 women with no prior knee injuries were enrolled: 10 premenopausal, eumenorrheic participants and 15 anovulatory control participants (6 postmenopausal and 9 premenopausal using oral contraceptives). Bilateral knee magnetic resonance imaging was performed at 4 time points evenly spaced over 1 month, with the first visit within 24 hours of menses onset. Ovulation status was confirmed using commercially available ovulation predictor kits. Three-dimensional UTE sequences (11 echoes; 0.03-25 ms) were acquired to evaluate bicomponent ACL T2* metrics. Linear mixed-effects models assessed temporal differences in long and short T2* values, and the Cohen d quantified effect size. RESULTS: Eumenorrheic participants demonstrated significantly shorter preovulatory long T2* values compared with postovulatory values (mean difference, 1.0 ms [95% CI, 0.2-1.9 ms]; P = .015; Cohen d = 0.51). No significant temporal differences were observed for any T2* metric in anovulatory controls. CONCLUSION: Eumenorrheic female participants exhibited significant preovulatory to postovulatory changes in ACL T2* metrics, while anovulatory controls demonstrated no significant changes over time. These findings suggest that ACL T2* metrics are sensitive to cyclic fluctuations in female sex hormones across the menstrual cycle.

Humans

Topologically distinct intratumoral heterogeneity scores for predicting high-risk pathological grades in invasive lung adenocarcinoma: A multicenter study across four institutions.

High-risk subtypes of invasive lung adenocarcinoma (IAC), particularly micropapillary- or solid-predominant patterns, are closely associated with poor prognosis. This multicenter retrospective study developed and validated a predictive model for the preoperative identification of these high-risk subtypes using topologically distinct intratumoral heterogeneity (ITH) scores derived from CT images. The study included 1,051 patients with IAC. Two complementary ITH scores were developed: a two-dimensional ITH score, which integrated local radiomics features with global pixel distribution patterns on the largest cross-sectional CT slice, and a three-dimensional ITH score, which extended this quantification across the entire tumor volume. Clinicoradiological features and ITH scores were incorporated as model inputs to construct six base machine learning classifiers and a final stacking ensemble classifier. Model interpretability and robustness were evaluated using SHapley Additive exPlanations (SHAP)-based ablation analyses. An independent dataset from The Cancer Imaging Archive (TCIA) was used for external validation to investigate associations between ITH scores and pathological characteristics, genomic features, recurrence-free survival, and overall survival. The stacking ensemble classifier achieved the best predictive performance, with an area under the receiver operating characteristic curve of 0.875, outperforming models based solely on radiomics features (0.834) or clinicoradiological features (0.792). SHAP analysis identified the 3D ITH score as the most influential contributor to model output, and TCIA validation showed that higher 3D ITH scores were associated with more aggressive tumor biology and poorer survival outcomes. The topologically distinct 3D ITH score may provide a clinically meaningful imaging biomarker for preoperative risk stratification in IAC.

Journal Article

Radiographic assessment and orthodontic intervention effects on orthodontically induced root resorption: a systematic review and meta-analysis of clinical trials.

The relative contribution of radiographic methods and characteristics of the orthodontic intervention to orthodontically induced root resorption (OIRR) remains unknown. The aims of this systematic review and meta-analysis were to (1) estimate the pooled OIRR effect across orthodontic intervention versus comparator contrasts, (2) compare pooled estimates by radiographic method (2D [two-dimensional] vs. 3D/CBCT [three-dimensional/cone-beam computed tomography]), and (3) explore whether force mechanics (intrusive versus nonintrusive) modified OIRR magnitude. Seven randomized controlled trials and one prospective study (January 2010-October 2025) were included. Only OIRR was the outcome, reported as correlation coefficients (r). The primary analysis combined within-study intervention-versus-comparator estimates. Subgroup analysis of 2D versus 3D/CBCT imaging was prespecified, whereas post-hoc analysis of intrusive versus nonintrusive mechanics was performed. The pooled analysis for the primary outcome showed a small, nonsignificant OIRR effect (r = 0.07; 95% confidence interval [CI]: -0.12 to 0.27; p = 0.372) with high heterogeneity (I2 = 84.0%). Radiographic method did not change the pooled estimates significantly (p = 0.331). Force-mechanics analysis showed that intrusive mechanics was related to significantly higher root resorption than nonintrusive mechanics (r = 0.40; 95% CI = 0.15 to 0.65 versus r = -0.03; 95% CI = -0.16 to 0.10; p < 0.001). This accounted for 87.1% of the between-study variance. The average orthodontic intervention effect on OIRR was small and not significant; however, the OIRR magnitude was strongly affected by force mechanics, particularly by intrusive forces. There was no significant difference in pooled estimates by radiographic method; however, 3D/CBCT provides superior volumetric quantification and should be used judiciously according ALARA (as low as reasonably achievable) principles.

Root Resorption

Stem Cell Differentiation Disperses Transcriptional Clusters via a Conserved Surface-Condensate Trajectory.

Stem cells exhibit exceptionally prominent transcriptional clusters, which dissolve with progressing differentiation. Although these clusters are assigned central roles in embryonic gene regulation, their formation and loss during differentiation remain poorly understood. This study reveals that these prominent clusters disperse along a conserved trajectory in mouse embryonic stem cells, fruit fly testes, and zebrafish embryos. Imaging and lattice simulations show that these clusters form via surface condensation on H3K27ac-marked super-enhancer regions, which act as genomic scaffolds. Upon differentiation, partial loss of these active epigenetic marks and transcription-driven unfolding lead to dispersal of the prominent clusters. The block copolymer-based lattice simulations explain this process as a conserved trajectory through a three-dimensional state space, governed by surface condensation principles that extend beyond canonical liquid-liquid phase separation. This work marks surface condensation as a biophysical mechanism for the dynamic organization of stem cell-specific transcriptional hubs and demonstrates evolutionary conservation in several organisms. By uncovering a conserved biophysical mechanism for transcriptional organization in development, our work illustrates how polymer properties can contribute to the control of cell identity and&#xa0;fate.

Animals

Integrative quantum and systems biology of cancer: From molecular fluctuations to ecological outcomes.

This review treats cancer as a multiscale adaptive system, asks what the framework must predict to be worth adopting, and separates at each scale what the evidence establishes from what is proposed. It is an expert narrative synthesis, not a systematic review, and states the limits of that design. Proton transfer and tautomeric shifts contribute to spontaneous mispairing but do not license claims of directed or non-random mutation: replication timing, three-dimensional chromatin organization, sequence context and known mutagenic processes explain most mutational heterogeneity, leaving any quantum contribution as a residual against that baseline. The Waddington quasi-potential is bounded: outside detailed balance the dynamics are not gradient-derivable and require a probability-flux term. Hysteresis, rate-limited bimodality and return to state after perturbation distinguish an attractor from a transcriptomic cluster. Single-cell karyotype and live-imaging evidence supports whole-genome doubling as an unstable intermediate of heterogeneous origin and context-dependent consequence, not a uniform adaptive strategy. Systems and synthetic biology, virtual cells and digital twins are assessed against benchmarks, not promise. Tissue-scale ecology is reported with the spatial measurements now quantifying it, including evidence that stromal niche construction is not uniformly tumor-supporting. RNA modification is a layer in its own right, showing that the interpretation of a regulatory signal, not its magnitude, is biologically decisive. A dedicated section states the framework's commitments, the observable and evidence at each scale, and what would falsify them, asking what this adds to somatic mutation theory with clonal evolution and plasticity.

Neoplasms