The effect of intrauterine devices containing zinc and copper on their levels in serum.

Serum levels of copper and zinc were determined in 11 health women in whom Latex Leaf intrauterine devices (IUDs) containing copper and zinc had been inserted. Patients with low levels of serum copper or zinc before insertion usually had increased levels of either of these metals while using the device, but they did not exceed the upper limits of normal values. When the group was considered as a whole, the serum levels of zinc showed a slight tendency to increase with duration of IUD use, whereas there was no statistical difference between the serum levels of copper before and after insertion of the IUD.

Adult

Experience with two different medicated intrauterine devices: a comparative study of the Progestasert and Nova-T.

A comparative study of the Progestasert (UPS) and the Nova-T in 326 randomly selected women was carried out. The observation period was 1 year. The over-all continuation rates for the two types of intrauterine devices (IUDs) were similar. The expulsion rate for the Nova-T (9.2%) was considerably higher (P = 0.001) than that for the UPS (1.2%). Medical removals for bleeding/pain were more frequent (P = 0.028) for the UPS (15.4%) as compared with the Nova-T (6.1%). The pregnancy rate for the UPS (Pearl index = 4.8) was insignificantly higher than that for the Nova-T (Pearl index = 2.8). Two of the pregnancies in the UPS group were ectopic. No significant changes in the reactive immunoglobulins (IgA, IgG, or IgM) were observed in either of the groups. Our results indicate that neither of these two IUDs is preferable to the already existing medicated IUDs, such as the Copper T or the Copper 7.

Adult

Effect of a copper IUD on the incorporation of (3H)thymidine and (5-3H)uridine into the endometrium of the rabbit during early pregnancy.

The influence of a copper IUD on the incorporation of [3H]thymidine and [5-3H]uridine into the endometrium of the rabbit was studied during early pregnancy. The effect of the copper device was compared with those of polyethylene and platinum IUDs. The comparison showed that the presence of a copper IUD resulted in a significantly lower incorporation of [3H]thymidine on the 3rd day of pregnancy and in a higher incorporation of [3H]thymidine and [5-3H]uridine on the 5th day of pregnancy. The increase in the total amount of DNA in the endometrium in early pregnancy was markedly reduced in the copper IUD-containing horn, and autoradiography showed that the labelling frequency of epithelial cells in the endometrium was significantly reduced. A possible effect of the copper IUD on the stromal cells is discussed. These effects of copper could be due either to an altered hormonal responsiveness of the endometrium in the presence of copper or to a 'direct' effect of copper on nucleic acid metabolism.

Animals

Fracture and chemical composition of the deposit formed on the Lippes loop after prolonged use.

In order to confirm or refute the theory that there is the need to replace IUD's every few years due to their breaking, 26 Lippes Loops were tested. The sediment found on the devices was composed mainly of calcium carbonate. After removal of the sedimentation, it was seen that there was some corrosion of the body of the devices which caused a decrease in the IUD thickness. Pressure tests showed that an IUD which has been in use for a long period of time is more rigid, has less ability to deform and breaks under less pressure. It seems that the current medical opinion stating that IUD's should be replaced every few years, is valid.

Calcium Carbonate

Electrochemical effects of metals on IUDs.

Electrochemical effects within the uterus are being studied, particularly as they pertain to IUDs made in total or in part of metals. The intrauterine potential as measured with either metal or nonpolarizable salt electrodes is positive at the fundal with respect to the cervical end of the uterus. Placement of dissimilar metal electrodes within the uterus will induce voltage gradients that are roughly predictable from their cell potential in blood as an electrolyte. When copper and zinc electrodes are placed at opposite ends of the uterus, they induce voltage gradients that are typically greater than 100 mv per cm. External copper and zinc wires connected at one end, and with the other ends in contact with various positions on the skin of rats, were found to influence potential gradients within the uterus. When a length of zinc wire was wound around the upper portion of the stem of a small Cu-7 200 IUD, it took about 1 year from insertion for the zinc to disappear. When the zinc wire was wound around the lower portion of the stem, it disappeared in 1 month. The zinc reduced intrauterine corrosion of the copper and it was more effective at reducing copper corrosion when in the lower stem position.

Action Potentials