PubMed HealthSearch

SEARCH · PubMed Health

Results for “Lasers, Solid-State”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Potential use of holmium lasers for angioplasty: evaluation of a new solid-state laser for ablation of atherosclerotic plaque.

Tissue effects of the mid-IR Holmium laser (emitting at a wave-length of 2130 nm) were evaluated. This wavelength is attractive because it combines high water absorption and easy transmission through standard optical fibres. The laser was pulsed with pulse durations in the range of 100 microseconds and repetition rates between 2 and 6 Hertz. For all experiments a repetition rate of 2 Hertz was used. The laser beam was coupled into waterfree quartz fibers with core diameters of 200 and 800 microns with an efficiency of 70 and 80%, respectively. Ablation of atherosclerotic plaque has been performed at an ablation threshold of 10J/cm2 for the 800 microns and 40J/cm2 for the 200 microns fibre. Removal of calcified plaque was possible. Ablation efficiency increased in a non-linear fashion with increasing pulse energies. The ablation rate per pulse was approximately 2 mm at energy fluences of 1000J/cm2 for the 200 microns fibre and 1.25 mm at energy fluences of 70J/cm2 for the 800 microns fibre; a further increase in energy densities did not result in higher ablation rates. On macroscopic examination only very limited thermal injury was found in crater adjacent tissue structures. Crater edges were even and did not reveal signs of crater charring or debris in the crater lumen. However, the histologic specimens revealed zones of thermal damage extending 100 up to 1000 microns lateral into adjacent tissue. Thermal damage increased with increasing radiant exposures and depended on the medium used.

Angioplasty, Laser

Holmium laser angioplasty after failed coronary balloon dilation: use of a new solid-state, infrared laser system.

A new solid-state laser system was used in a case of saphenous vein graft occlusion untreatable by standard very low-profile balloon angioplasty. The 2100 nm infrared pulsed thulium/holmium: YAG laser successfully recanalized an obtuse marginal bypass graft without complications. The holmium laser has several advantages over excimer systems and may prove an effective adjunct or alternative to coronary balloon angioplasty.

Aged

Infrared laser sclerostomies.

Four solid-state lasers with three fiberoptic delivery systems were used to perform laser sclerostomies in an acute-injury rabbit model and in fresh human globes. The lasers used were continuous-wave neodymium:yttrium aluminum garnet (YAG, 1.06 microns) and pulsed holmium:yttrium scandium galliam garnet (YSGG) (2.10 microns), erbium:YSGG (2.79 microns), and erbium:YAG (2.94 microns). Thermal damage to tissue and total laser energy required to produce sclerostomies decreased with increasing wavelength. In human tissue using a 600-microns fused silica fiberoptic, maximum thermal damage (greater than or equal to 100 microns) was noted at 1.06 microns with a total energy of 21 J at a power density of 2.5 kW/cm2. In addition, focal damage to the iris and ciliary body was noted at this wavelength. The least amount of thermal damage (15-20 microns) and lowest total energies needed were found at 2.94 microns. A 250-microseconds pulse length and pulse radiant exposures of 3.6 J/cm2 and 14.3 J/cm2 were used for the low hydroxyl-fused silica (500 microns) and zirconium fluoride (250 microns) fiberoptics, respectively. Although zirconium fluoride fibers have high through-put efficiencies that facilitate study of laser tissue interactions at 2.94 microns, problems encountered with fragility and solubility of the bare tip in aqueous media limit its usefulness. A high attenuation rate with the low hydroxyl-fused silica fiber limited its usable length to 35 cm at 2.94 microns. Tissue damage during sclerostomy formation was minimized at 2.94 microns, reaching a maximum at 1.06 microns. Minimizing tissue damage theoretically could decrease subconjunctival scarring and filtration failure.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Vascular injury and time course of smooth muscle cell proliferation after experimental holmium laser angioplasty.

BACKGROUND: In vitro experiments have shown that holmium laser energy can effectively ablate even calcified plaque in human arterial vessels. Because high-energy densities from holmium lasers can easily be transmitted through quartz fibers, this solid-state laser has been suggested as an alternative intraluminal treatment of atherosclerotic plaque. METHODS AND RESULTS: To develop an intimal plaque, 35 New Zealand White rabbits underwent electrical stimulation of their right carotid artery for 28 days. Subsequently, in 25 rabbits, holmium laser angioplasty (wavelength, 2.12 microns; pulse duration, 150 microseconds; energy density, 350 mJ/mm2) was performed. To study the morphological results, the vessels were excised after 7, 14, 28, and 42 days. Cross sections were analyzed in regard to laser-specific injury. Staining of alpha-actin was used to identify smooth muscle cells (SMCs). After bromodeoxyuridine labeling, the extent of proliferation (number of cells undergoing DNA synthesis) was determined by using a monoclonal antibody. Holmium laser ablation resulted in an initial decrease of the numbers of intimal cell layers in the early group (7 days after treatment: 5 +/- 1 cell layers with 76 +/- 39 microns; control: 13 +/- 3 cell layers with 144 +/- 44 microns). Quantification of SMCs undergoing DNA synthesis in the intima (control: 51 +/- 19 cells/mm2) showed a significant increase of labeled cells after 7 (216 +/- 74 cells/mm2, p = 0.003) and 14 days (281 +/- 139 cells/mm2, p = 0.011). Integrity of the internal elastic lamina was disrupted in all animals after intervention. Seven and 14 days after treatment, a considerable reduction of medial cell nuclei was found in 10 of 12 animals. SMC proliferation in the medial layer was increased within the first 2 weeks after laser ablation (168 +/- 113 cells/mm2; control: 8 +/- 4 cells/mm2; p = 0.023). Six weeks after holmium laser angioplasty, SMC proliferation had returned to control levels in the intima and remained increased in the medial layer. This proliferative response resulted in a significant increase of intimal thickening within 6 weeks after laser ablation (30 +/- 6 cell layers, 375 +/- 97 microns resp.; p = 0.001 each). CONCLUSIONS: Holmium laser treatment leads to considerable vessel wall injury and results in SMC proliferation in the intimal and medial layer with a maximum of proliferative activity within the first 2 weeks. Subsequently, this results in considerable intimal and medial hyperplasia within 6 weeks after treatment.

Angioplasty, Laser

Subconjunctival THC: YAG laser limbal sclerostomy Ab externo in the rabbit.

A chromium-sensitized, and thulium and holmium-doped YAG laser (THC:YAG laser) was used to create bilateral limbal sclerostomies in six Dutch pigmented rabbits. The laser is a long-pulsed (300 microseconds) [corrected], compact, self-contained, solid-state laser operating in the near infrared (2.1 microns). A 1-mm conjunctival stab incision was made 12 mm away from the sclerostomy site to allow entry of a specially designed 26-gauge (480 microns) optic probe that delivers energy at right angles to the long axis of the fiber. Probe insertion minimally disturbed the conjunctiva. Pulse energies of 60 to 150 mJ were used with a repetition rate of 5 pulses/s. Energy levels ranging from 1.35 to 6.6 J produced full-thickness sclerostomies. Histopathology showed a sharply defined perforating limbal wound at all energy levels. The overlying conjunctiva was intact, with swelling of the adjacent cornea. A peripheral iridectomy was intentionally created with the laser through the peripheral limbus, resulting in a sharply defined perforating tract through the iris/ciliary body. This technique may simplify filtering sclerostomy surgery, without anterior chamber instrumentation and with minimal conjunctival trauma.

Animals

Holmium: yttrium aluminum garnet laser-assisted endoscopic sinus surgery: laboratory experience.

Endoscopic sinus surgery has gained wide acceptance since its introduction into the United States. Complex sinus anatomy and troublesome bleeding have been associated with complications, which vary in severity from synechia to blindness and leakage of cerebrospinal fluid. Endoscopic sinus surgery using a holmium: yttrium aluminum garnet pulsed solid-state laser oscillating at 2.1 microns with fiberoptic delivery was performed in the laboratory, and the results were compared with those of conventional endoscopic sinus surgery. Three beagle dogs, six human cadaver heads, and one calf head were used in the in vivo and in vitro studies to evaluate the bone ablation, tissue coagulation, and hemostatic properties of the holmium: yttrium aluminum garnet laser. Modified endoscopic telescopes for sinus surgery, a newly developed handpiece for fiberoptic delivery, and other surgical instruments were used. The results indicate that the holmium: yttrium aluminum garnet laser and new delivery instrumentation provide good hemostasis and controlled soft-tissue ablation and bone removal. The access to all sinuses in the human cadaver model was very good. The canine in vivo study showed delayed but complete healing on the laser-treated side. Clinical evaluation of the holmium: yttrium aluminum garnet laser is warranted to increase the precision and safety of endoscopic sinus surgery.

Animals

In vivo measurement of glucose concentration with lasers.

Common polarimeters defined the concentration of an optically active sample by measuring the intensity of the light beam after it has passed through the analyser. Consequently, it can be stated that up to now, there have been the disadvantages of having a signal dependent on absolute light intensity. The new method that is described has a sensitivity that is in great measure independent of absolute light intensity, whereby only one light trace is necessary. The new principle uses no mechanical rotations. Instead, an electrical signal indicates the amount of optical rotation of the sample. The high sensitivity that can be reached is theoretically only limited by polarization noise. By going to the uttermost physical and electronic lengths, sensitivity values of more than 10(-5) degrees can be reached. Furthermore, the mechanical dimensions of the apparatus can be made very small by the application of a solid-state laser.

Glucose

Efficacy and safety of thulium fiber laser versus conventional holmium:YAG laser in anatomical endoscopic enucleation of the prostate: a systematic review and pairwise meta-analysis.

PURPOSE: Anatomical endoscopic enucleation is an established treatment for benign prostatic obstruction. Whether thulium fiber laser enucleation (ThuFLEP) improves outcomes over conventional holmium:YAG laser enucleation (HoLEP) remains uncertain. We compared the efficacy and safety of ThuFLEP versus non-MOSES-modulated HoLEP. METHODS: We performed a PRISMA-compliant systematic review and pairwise meta-analysis of randomised and comparative cohort studies comparing ThuFLEP and conventional HoLEP in adult men. Six databases were searched. Outcomes included International Prostate Symptom Score (IPSS), IPSS quality-of-life score, maximum urinary flow rate (Qmax), post-void residual volume, hospital stay, and complications. Risk of bias and certainty of evidence were assessed with RoB 2/ROBINS-I and GRADE. RESULTS: Seven non-overlapping comparative populations in eight publications included 3,509 patients. ThuFLEP was associated with a small statistically significant reduction in IPSS at 3 months (mean difference [MD] -1.04 points, 95% confidence interval [CI] -1.81 to -0.28) of uncertain clinical relevance. Qmax differences were small and directionally inconsistent across follow-up (favouring HoLEP at 3 months and ThuFLEP at 6 and 12 months) and derived mainly from retrospective cohorts, with neutral randomised subgroups. Stress and urge urinary incontinence were less frequent overall (RR 0.75, 95% CI 0.58 to 0.96, and RR 0.39, 95% CI 0.22 to 0.68), but both estimates depended on one large registry cohort and were not robust to its exclusion. Most other complications and hospital stay showed no clear between-group difference. Limitations include few studies per outcome, heterogeneity, sparse safety events, inconsistent prostate-specific antigen reporting, and mostly low/very low certainty evidence. CONCLUSION: ThuFLEP and conventional HoLEP are clinically comparable with no definitive superiority of either laser. Platform selection should be individualised according to surgeon expertise, institutional resources, and patient characteristics. Future trials should standardise cost-effectiveness outcomes and investigate whether the distinct laser-tissue interactions impact adenoma clearance, PSA reduction, enucleation completeness, and long-term durability.

Humans

Effectiveness of high-power laser use in the removal of esthetic restorations: a systematic review.

This systematic review aimed to evaluate the effectiveness of high-power lasers in the removal of esthetic restorations compared with conventional methods. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and registered in PROSPERO (registration number: CRD420251055736). A comprehensive electronic search was performed in MEDLINE, Scopus, Embase, Web of Science, and the Cochrane Library. Study selection, data extraction, and methodological quality assessment were independently performed by four reviewers using QUIN tool for in vitro studies. A total of 2.384 records were identified, of which 19 in vitro studies conducted on extracted human permanent teeth met the eligibility criteria and were included in the qualitative synthesis. The included studies evaluated different high-power laser systems, predominantly Er: YAG and Er, Cr: YSGG lasers, as well as CO₂ lasers. Five studies were classified as high quality, whereas the remaining fourteen studies were classified as moderate quality. Available laboratory evidence suggests that laser-assisted techniques may represent a potential alternative approach for removing esthetic restorations, with advantages including conservative tissue removal, reduced damage to underlying tooth structures, and intrapulpal temperature increases within acceptable limits. The Er: YAG laser was the most frequently investigated system, with power settings ranging from 1.5 to 5.9 W, showing particularly favorable laboratorial performance in the removal of lithium disilicate restorations, especially in thinner substrates. Within the limitations of the available evidence, high-power lasers appear to be a promising and minimally invasive alternative to conventional methods for the removal of esthetic restorations. However, the predominance of in vitro studies highlights the need for well-designed clinical trials to confirm these findings and support their clinical application.

Humans

Holmium laser enucleation of the prostate for the treatment of lower urinary tract symptoms in men with benign prostatic hyperplasia.

RATIONALE: A range of surgical options is available for the treatment of benign prostatic hyperplasia (BPH), including holmium laser enucleation of the prostate (HoLEP). The evidence is unclear regarding differences in functional, perioperative, and morbidity outcomes between these modalities. OBJECTIVES: To assess the effects of holmium laser enucleation of the prostate compared with other surgical treatments for lower urinary tract symptoms in men with benign prostatic hyperplasia. SEARCH METHODS: We searched multiple databases (including MEDLINE, Embase, CENTRAL, Web of Science, LILACS, and the International HTA database), trial registries, and conference abstracts through April 08, 2026. ELIGIBILITY CRITERIA: We only included randomized trials of men over 40 years of age with a prostate volume of at least 20 mL (assessed by digital rectal examination, ultrasound, or conventional imaging) who exhibited lower urinary tract symptoms (LUTS) defined by an International Prostate Symptom Score (IPSS) of eight or greater undergoing surgical interventions for BPH. OUTCOMES: The critical outcomes measured were the urologic symptoms score, the quality-of-life score, and major adverse events. The important outcomes measured were: re-treatment, erectile function, ejaculatory function, transfusions, acute urinary retention, indwelling urinary catheter duration, and hospital stay duration. RISK OF BIAS: We used the Cochrane risk of bias tool (RoB 1) to assess for potential sources of bias on a study and outcome level basis. SYNTHESIS METHODS: We pooled outcome data using the random-effects model and performed meta-analyses using the Mantel-Haenszel method. We assessed statistical heterogeneity in the pooled data by visually inspecting forest plots and using the I2 statistic to quantify it. We used the GRADE framework to assess the certainty of evidence. INCLUDED STUDIES: We included 52 trials that included 6242 participants that compared HoLEP to other surgical interventions for benign prostatic hyperplasia. The median age of participants across the studies ranged from 65 to 74 years. The baseline prostate volume ranged from 30 cc to 142 cc. Baseline IPSS scores ranged from 19.6 to 28.6 (range 0-35). SYNTHESIS OF RESULTS: We prioritized comparing HoLEP with transurethral resection of the prostate (TURP) at short-term follow-up (up to 12 months), because TURP is the long-standing reference standard and the predominant comparator in randomized surgical trials. Findings for the four remaining comparisons (laser ablation, alternative energy source enucleation, other minimally invasive therapies, and simple prostatectomy), for long-term follow-up, and for all remaining outcomes are reported in full in the review. Compared to TURP, at short-term follow-up: Critical outcomes - HoLEP may result in little to no difference in short-term urologic symptom scores measured using the IPSS (range 0 to 35; lower values reflect fewer symptoms) (MD -0.67, 95% CI -1.20 to -0.14; I² = 93%; 14 studies, 1666 participants, low-certainty evidence). - HoLEP may result in little to no difference in short-term quality of life (range 0 to 6; lower values reflect better quality of life) (MD -0.04, 95% CI -0.23 to 0.15; I² = 73%; 6 studies, 876 participants, low-certainty evidence). - HoLEP may result in little to no difference in short-term major adverse events (RR 0.75, 95% CI 0.35 to 1.58; I² = 0%; 10 studies, 1147 participants, low-certainty evidence). Important outcomes - HoLEP likely results in little to no difference in re-treatment (RR 0.45, 95% CI 0.14 to 1.50; I² = 0%; 8 studies, 813 participants, moderate-certainty evidence). - HoLEP likely results in little to no difference in erectile function (MD -0.03, 95% CI -0.47 to 0.42; I² = 0%; 3 studies, 518 participants, moderate-certainty evidence). - Ejaculatory function: we did not find any data for this outcome. - HoLEP likely reduces the need for blood transfusion (RR 0.19, 95% CI 0.09 to 0.42; I² = 0%; 15 studies, 1755 participants, moderate-certainty evidence). AUTHORS' CONCLUSIONS: Compared with TURP, HoLEP may achieve similar relief of urologic symptoms, similar quality of life, and similar rates of major adverse events in the first 12 months after surgery, and probably similar re-treatment rates and erectile function. HoLEP likely reduces the need for blood transfusion; this is the only advantage of HoLEP that the randomized evidence, as summarized here, supports as clinically important. There was insufficient evidence to assess outcomes in the subset of individuals with larger prostates or on anticoagulation. Future research should prioritize long-term trials reporting sexual function and urinary incontinence outcomes, recruit men with very large prostates (≥ 150 cc) or on anticoagulation therapy, and evaluate cost-effectiveness and training requirements. FUNDING: No external funding was received for this review. REGISTRATION: The protocol for this review was published in the Cochrane Database 2019 (https://doi.org/10.1002/14651858.CD013291).

Humans

[Holmium:YAG and erbium:YAG infrared laser osteotomy].

The in-vivo bone ablation characteristics of a pulsed solid-state erbium:YAG laser were compared to those of a pulsed solid-state holmium:YAG laser. Partial osteotomies in the maxillary, the mandibulary, and the nasal bones of white rats were performed. The tissue response was examined by light microscopy. Thermal gradients following the laser application were also measured. Over all energy levels tested the erbium:YAG laser produced ablation of bone with minimal thermal damage to the adjacent tissue. The results of this study are promising for future application of the infrared holmium- and erbium:YAG lasers in otorhinolaryngology.

Animals

Comparison of a 755-nm picosecond laser and a 1565-nm nonablative fractional laser for the treatment of atrophic acne scars: a 20-week prospective, randomized, split-face clinical study.

To compare the efficacy and safety of a 755-nm picosecond laser with a diffractive lens array (P-DLA) and a 1565-nm nonablative fractional laser (NAFL) for the treatment of atrophic acne scars. Twenty-seven patients with atrophic acne scars underwent three sessions of randomized split-face treatment with P-DLA and NAFL at 4-week intervals. Patients were followed up at 1, 2, and 3 months after the final treatment. Efficacy was assessed using the &#xc9;chelle d'&#xc9;valuation Clinique des Cicatrices d'Acn&#xe9; (ECCA) grading scale, the Investigator's Global Assessment (IGA) score, patients' self-rated improvement, and overall satisfaction. Treatment-related adverse reactions were recorded daily by patients until resolution. Both modalities demonstrated significant improvements in scar appearance based on ECCA score, IGA score, and patients' self-rated improvement (P&#x2009;<&#x2009;0.001). No statistically significant differences in efficacy were observed between the two treatments. However, the P-DLA group showed higher patient satisfaction (P&#x2009;=&#x2009;0.035) and a more favorable safety profile, including shorter durations of erythema and edema and the absence of crusting. Both P-DLA and NAFL were effective and safe for the treatment of atrophic acne scars, with similar efficacy. P-DLA offered better tolerability.

Humans

Minimal access surgery and the future of interventional laparoscopy.

Minimal access surgery is intended to minimize the trauma of access without compromising exposure of the operative field. Its major benefits include diminished cost of therapy due to a reduced hospital stay and accelerated recovery with early return to full activity. The approaches used in minimal access surgery are laparoscopic, endoluminal, perivisceral, intra-articular, and combined. Many abdominal and thoracic procedures are being adapted to the minimal access approach. Developmental requirements include improvements in light delivery systems; three-dimensional television imaging; better surgical instrumentation; ultrasound probes for internal and external scanning; stapling devices; and tunable, portable solid-state diode lasers. In addition, however, adequate prospective evaluation of laparoscopic procedures, established or new, must be undertaken in the major academic institutions.

Evaluation Studies as Topic

Comparison of the erbium-yttrium aluminum garnet and carbon dioxide lasers for in vitro bone and cartilage ablation.

The in vitro bone- and cartilage-ablation characteristics of the solid-state erbium:yttrium aluminum garnet laser were compared to those of the carbon dioxide laser. Ablations of fresh, frozen cadaver septal cartilage and maxillary sinus bone were performed using total energies between 1 and 6 J. Specimens were studied using hematoxylin and eosin stain and digitized, computer-assisted measurements of 35-mm photographs. Erbium-yttrium aluminum garnet-ablated bone averaged 5 microns of adjacent tissue thermal injury, compared with 67 microns with carbon dioxide-ablated bone. Erbium-yttrium aluminum garnet-ablated cartilage averaged 2 microns of adjacent tissue thermal injury, compared with 21 microns with the carbon dioxide-ablated cartilage. The tissue-ablation characteristics of the erbium-yttrium aluminum garnet laser are promising for future otolaryngologic applications.

Aluminum

Lithotripsy with a Q-switched alexandrite laser system. Preliminary in vivo and in vitro results.

An alexandrite laser system which emits a wavelength of 750 nm, has recently been proposed as a substitute for the pulsed-dye laser (504 nm) for laser lithotripsy. We have carried out in vitro lithotripsy trials in order to evaluate the efficiency of a flashlamp pumped Q-switched alexandrite laser. In the first experiment, we compared the Q-switched alexandrite laser to the pulsed-dye laser with respect to their effectiveness in fragmentizing urinary and model stones (HMT target stones). In the second experiment, we evaluated the effect of Q-switched alexandrite radiation on the urinary wall (bladder, ureter, renal pelvis and liver) of animals (Wistar rats and rabbits) under general anesthesia. In conclusion, the alexandrite laser system is comparable to the pulsed dye laser. The 750-nm wavelength involves minimal risk of damage to the urinary tract and constitutes a safe alternative, especially during blind lithotripsy. It is a compact solid-state system, with no toxic chemical agents as laser material.

Animals

A new method for characterizing beta-ray ophthalmic applicator sources.

A technique is described which enables one to obtain detailed dose characteristics of 90Sr beta-ray ophthalmic applicators. A radiochromic radiation detector which is a solid-state solution of hexahydroxyethyl pararosaniline cyanide in a nylon polymer (i.e., thin foil), has been used to determine the surface dose rate and dose distribution of these sources. The detectors are rugged, easily handled, have an equivalent response (optical density per unit absorbed dose) to photons and electrons, and produce high-resolution images. They have been found useful for this application due to the high surface dose rates [0.10-1.0 Gy (H2O)/s] and their low sensitivity (approximately 10(4) Gy for an optical density of 1.0). The foils have been evaluated on a He-Ne scanning laser densitometer with a resolution of 0.3 mum. Comparison with NIST (formerly NBS) extrapolation ionization chamber measurements indicates surface dose-rate agreement within 6%. Spectral dosimetric characteristics are presented and discussed.

Beta Particles

Transition dipole orientations in the early photolysis intermediates of rhodopsin.

The linear dichroism spectrum of rhodopsin in sonicated bovine disk membranes was measured 30, 60, 170, and 600 ns after room temperature photolysis with a linearly polarized, 7-ns laser pulse (lambda = 355 or 477 nm). A global exponential fitting procedure based on singular value decomposition was used to fit the linear dichroism data to two exponential processes which differed spectrally from one another and whose lifetimes were 42 +/- 7 ns and 225 +/- 40 ns. These results are interpreted in terms of a sequential model where bathorhodopsin (BATHO, lambda max = 543 nm) decays toward equilibrium with a blue shifted intermediate (BSI, lambda max = 478 nm). BSI then decays to lumirhodopsin (LUMI, lambda max = 492 nm). It has been suggested that two bathorhodopsins decay in parallel to their products. However, a Monte Carlo simulation of partial photolysis of solid-state visual pigment samples shows that one mechanism which creates populations of BATHO having different photolysis rates at 77 K may not be responsible for the two decay rates reported here at room temperature. The angle between the cis band and 498-nm band transition dipoles of rhodopsin is determined to be 38 degrees. The angles between both these transition dipoles and those of the long-wave-length bands of BATHO, BSI, and LUMI are also determined. It is shown that when BATHO is formed its transition dipole moves away from the original cis band transition dipole direction. The transition dipole then moves roughly twice as much towards the original cis band direction when BSI appears. Production of LUMI is associated with return of the transition dipole almost to the original orientation relative to the cis band, but with some displacement normal to the plane which contains the previous motions. The correlation between the lambda max of an intermediate and its transition dipole direction is discussed.

Animals