PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Magnetic Fields”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Selective loss of progenitor subsets following clinical CD34+ cell enrichment by magnetic field, magnetic beads or chromatography separation.

In this preclinical evaluation we have compared the efficacy of three clinical CD34+enrichment procedures with respect to purity, yield and recovery, as well as risk of selective loss of CD34+ lineage-specific subsets. The three devices work by different principles and have several different manipulation steps: The magnetic field separator uses paramagnetic iron-dextran particles; the magnetic microbead selection is based on the advantage of a large surface area for immobilisation of the monoclonal antibody within a very small volume; the original immunoabsorption technique is based on the use of biotinylated antibody applied to a column of avidin-coated sephadex beads. The results of this evaluation gave a median purity 96% (88-98%), 86% (62-97%), and 49% (18-85%), and median yield of 65% (54-100%), 40% (21-74%), and 30% (8-55%), respectively. Subset analysis recognised a selective loss of CD34+/61+ after enrichment, most likely due to class I-II antibodies used for the enrichment step or, alternatively, nonspecific binding of megakaryocytic progenitors. Tumour cell spiking experiments on a clinical scale documented an expected 2-4 log reduction resulting in a number of potentially malignant cells in the CD34 enriched product. Our data support four major conclusions: First, that magnetic field separation is superior to magnetic beads and chromatography selection, mainly due to the risk of cell loss and insufficient recovery with the two latter methods. Second, that late differentiated progenitors with CD34 class III epitopes present are lost during the enrichment procedures. The third major conclusion is that chromatography selection results in a selective loss of CD34bright cells, which are most likely uncommitted early progenitors. This was an unexpected finding which may be a consequence of an imbalance between the strong forces between biotin-avidin and insufficient physical manipulation for CD34+ cell release. Finally, the data document that CD34 selection alone is an inappropriate way to eliminate tumour cells due to the uncontrolled variables and the inconsistent outcome. The only products which can be expected to be purged free of tumour cells are the ones with very minimal (<10-5) contamination in the starting products, ie products documented tumour free with the most sensitive techniques for quantitation. If this is not the case, the optimal purging strategy may be a two-step procedure including CD34 selection and subsequent depletion of the tumour cells in question.

Antigens, CD34↗

Effects of static and radiofrequency magnetic field inhomogeneity in ultra-high field magnetic resonance imaging.

To characterize the severe static (B(0)) and radiofrequency (B(1)) magnetic field inhomogeneity in ultra-high field (> or =7 T) magnetic resonance imaging, gradient echo (GE) and spin echo (SE) images of in vivo and postmortem human brains were acquired. The B(0) and B(1) inhomogeneity were experimentally mapped and/or numerically simulated, and correlated with the image artifacts. Whereas B(0) inhomogeneity affects predominantly GE images near air/tissue interfaces, B(1) inhomogeneity affects SE images more severely and shows non-intuitive patterns. Mapping of the B(0) and B(1) inhomogeneity is important in characterizing image artifacts. This will help develop better B(0) and B(1) inhomogeneity correction methods.

Adult↗

Quantitative analysis of magnetic resonance imaging susceptibility artifacts caused by neurosurgical biomaterials: comparison of 0.5, 1.5, and 3.0 Tesla magnetic fields.

Magnetic resonance (MR) imaging is an important diagnostic tool for neurosurgical diseases but susceptibility artifacts caused by biomaterial instrumentation frequently causes difficulty in visualizing postoperative changes. The susceptibility artifacts caused by neurosurgical biomaterials were compared quantitatively by 0.5, 1.5, and 3.0 Tesla MR imaging. MR imaging of uniform size and shape of pieces ceramic (zirconia), pure titanium, titanium alloy, and cobalt-based alloy was performed at 0.5, 1.5, and 3.0 Tesla. A linear region of interest was defined across the center of the biomaterial in the transverse direction, and the susceptibility artifact diameter was calculated. Susceptibility artifacts developed around all biomaterials at all magnetic field strengths. The artifact diameters caused by pure titanium, titanium alloy, and cobalt-based alloy increased in the order of 0.5, 1.5, to 3.0 Tesla magnetic fields. The artifact diameter of ceramic was not influenced by magnetic field strength, and was the smallest of all biomaterials at all magnetic field strengths. The artifacts caused by biomaterials except ceramic increase with the magnetic field strength. Ceramic instrumentation will minimize artifacts in all magnetic fields.

Artifacts↗

Closed-chest cardiac stimulation with a pulsed magnetic field.

Magnetic stimulators, used medically, generate intense rapidly changing magnetic fields, capable of stimulating nerves. Advanced magnetic resonance imaging systems employ stronger and more rapidly changing gradient fields than those used previously. The risk of provoking cardiac arrhythmias by these new devices is of concern. In the paper, the threshold for cardiac stimulation by an externally-applied magnetic field is determined for 11 anaesthetised dogs. Two coplanar coils provide the pulsed magnetic field. An average energy of approximately 12 kJ is required to achieve closed-chest magnetically induced ectopic beats in the 17-26 kg dogs. The mean peak induced electric field for threshold stimulation is 213 V m-1 for a 571 microseconds damped sine wave pulse. Accounting for waveform efficacy and extrapolating to long-duration pulses, a threshold induced electric field strength of approximately 30 V m-1 for the rectangular pulse is predicted. It is now possible to establish the margin of safety for devices that use pulsed magnetic fields and to design therapeutic devices employing magnetic fields to stimulate the heart.

Animals↗

Image analysis of bioparticles accumulation and diamagnetic alignment in high-gradient magnetic field.

Magnetic properties of biological particles are measured in high-gradient magnetic separation (HGMS) analysis, revealing the concentrating process of nucleoprotein particles, ferritin, red blood cells, and eggs. A magnetic force acting on micrometer and submicrometer biological particles having diamagnetic or paramagnetic susceptibility with respect to the solution causes their movement and accumulation in gradient magnetic fields dependent on the values of the magnetic moments. The methods developed enable us to obtain the magnetic moments values of single particles and their assembly directly from magnetic separation and image analyses without assuming the detection of sizes. Our precision methods for the measurement of the capture traveling (magnetic diffusion) time and the accumulation (magnetic sedimentation) radius in HGMS show that it is really possible to determine the weak dia- or paramagnetic shifts of magnetic susceptibility up to 0.7x10(-10) (SI units). HGMS analysis of the concentrating process of nucleoprotein granules (microcells, DNA granules, or nucleosome core particles) with polarization microscopy reveals phase transitions for DNA in granules, and separation accumulation of particles enables the determination of the diamagnetic susceptibility and anisotropy properties. Magnetic concentration effects always occur in living systems because micrometer-located gradient magnetic fields inside an organism are strong enough to cause drifts of cellular complexes and organelles of micrometer and submicrometer sizes. We report the appearance of superparamagnetic contamination inside developing shrimp eggs. In the developing shrimps eggs, ferritin aggregates are observed under weak gradient magnetic fields and diaparaferromagnetic changes are detected. A significant interruption of egg development is revealed in such fields.

Animals↗

Bending of magnetic filaments under a magnetic field.

Magnetic beads and superparamagnetic (SP) colloid particles have successfully been employed for micromechanical manipulation of soft material, in situ probing of elastic properties, and design of smart materials (ferrogels). Here we derive analytical expressions for the equilibrium shape of magnetic fibers, considering two end-member cases, (a) SP or single-domain particles concentrated at the free end of cantilevered rods or tubes, and (b) filaments consisting of SP particles, with this case being mathematically equivalent to tubes containing SP particles. Our analysis yields also metastable equilibrium states (MES's), which only exist above a critical filament length, but become more stable with increasing magnetic field. The MES's for case (a) are, like the ground state, circular arcs, but more strongly bent. The multiform MES's in case (b), which comprise hairpin, sinuous, or even closed shapes, have recently been observed in experiments, too. We also study the effect of gravity on the balance between bending and magnetic energy, which leads to curves with inflection point if the influence of gravity is stronger than that of the magnetic field. Because of their simple experimental realization, case (a) magnetic filaments are deemed highly suitable for micromechanical experiments on long chains of polymer molecules. Another potential application of cantilevered magnetic filaments with magnetic material attached to the free end is in scanning probe microscopes. Because the magnetic field due to the magnetic tip is comparatively weak, the magnetization structure of the sample to be investigated would not be affected by the probe. Thus, for the examination of magnetically soft materials, probes in the form of magnetic filaments may hold advantages over tips usually employed in magnetic force microscopy.

Journal Article↗

Crossing the termination shock into the heliosheath: magnetic fields.

Magnetic fields measured by Voyager 1 show that the spacecraft crossed or was crossed by the termination shock on about 16 December 2004 at 94.0 astronomical units. An estimate of the compression ratio of the magnetic field strength B (+/- standard error of the mean) across the shock is B2/B1 = 3.05 +/- 0.04, but ratios in the range from 2 to 4 are admissible. The average B in the heliosheath from day 1 through day 110 of 2005 was 0.136 +/- 0.035 nanoteslas, approximately 4.2 times that predicted by Parker's model for B. The magnetic field in the heliosheath from day 361 of 2004 through day 110 of 2005 was pointing away from the Sun along the Parker spiral. The probability distribution of hourly averages of B in the heliosheath is a Gaussian distribution. The cosmic ray intensity increased when B was relatively large in the heliosheath.

Journal Article↗

Lack of mutagenic and co-mutagenic effects of magnetic fields during magnetic resonance imaging.

Mutagenic and co-mutagenic effects of static, pulsed bipolar gradient, and high-frequency magnetic fields, as well as combinations of them, were examined using the Ames test. The Ames test using Salmonella typhimurium bacteria, wild-type strain RTA, preincubation assay, without metabolic activation, was performed. All combinations of magnetic fields were tested with and without co-exposure to N-methyl-N'-nitro-N-nitrosoguanidine and benzo[a]pyrene-4,5-oxide, ethylene oxide, carboplatin, or cisplatin. As expected, chemical mutagens caused a clear-cut increase of the revertants in the Ames test. However, neither the static fields nor a combination of a static magnetic field with the time-varying bipolar gradient field or a pulsed high-frequency magnetic field caused an alteration in the number of revertants in the Ames test. No co-mutagenic effect of any magnetic field combination was observed. In conclusion, magnetic fields used during clinical magnetic resonance imaging (MRI) were neither mutagenic nor co-mutagenic.

Animals↗

Orientation of fibrin in strong magnetic fields.

Magnetic field orientation can be considered as a new valuable technique for the study of fibrin. Birefringence measurements during polymerization in the magnetic field enables a new approach to study the mode of association of fibrin monomers. Stable fully oriented clots can be obtained for investigation of the three-dimensional and the secondary structures of the fibrin fiber. Such experiments could be useful to assess the structure of other biopolymers diamagnetically anisotropic.

Animals↗

Destabilizing effect of time-dependent oblique magnetic field on magnetic fluids streaming in porous media.

The present work studies Kelvin-Helmholtz waves propagating between two magnetic fluids. The system is composed of two semi-infinite magnetic fluids streaming throughout porous media. The system is influenced by an oblique magnetic field. The solution of the linearized equations of motion under the boundary conditions leads to deriving the Mathieu equation governing the interfacial displacement and having complex coefficients. The stability criteria are discussed theoretically and numerically, from which stability diagrams are obtained. Regions of stability and instability are identified for the magnetic fields versus the wavenumber. It is found that the increase of the fluid density ratio, the fluid velocity ratio, the upper viscosity, and the lower porous permeability play a stabilizing role in the stability behavior in the presence of an oscillating vertical magnetic field or in the presence of an oscillating tangential magnetic field. The increase of the fluid viscosity plays a stabilizing role and can be used to retard the destabilizing influence for the vertical magnetic field. Dual roles are observed for the fluid velocity in the stability criteria. It is found that the field frequency plays against the constant part for the magnetic field.

Journal Article↗

Short communication: assessment of environmental disturbances to the static magnetic field in magnetic resonance installations.

The static magnetic field of MRI scanners can be affected by environmental factors. Magnetic resonance spectroscopy and functional imaging with single-shot echo-planar imaging (EPI) are particularly vulnerable to the movement of lifts, vehicles, trains and other large metallic masses in the vicinity. This work investigates the sensitivity of two different imaging techniques to assess disturbances of the static magnetic field: (i) phase changes in gradient-echo images of a uniform test object; and (ii) image displacement along the phase encoding direction in single-shot EPI images. For the latter a hexane sample was used, and the separation between CH2 and CH3 signals was taken as a reference. Both techniques were evaluated in a site known to be free of any significant environmental disturbances and validated by inducing a magnetic field disturbance. Both techniques provide valuable information in acceptance tests, allowing MRI users to evaluate and manage the environmental conditions surrounding a scanner. The single-shot EPI technique was found to be highly sensitive, being expected to detect magnetic field fluctuations down to 0.005 parts per million (ppm). The phase images method was found to be less sensitive (0.02 ppm) but is more easily available. The single-shot EPI technique was used in acceptance tests and environmental disturbances to the magnetic field of the order of 0.04 ppm were measured at the isocentre on two separate occasions.

Artifacts↗

Increased DNA synthesis in INIT/10T1/2 cells after exposure to a 60 Hz magnetic field: a magnetic-field or a thermal effect?

This study was designed to test the hypothesis that a 0.1-0.8-mT 60 Hz magnetic field may act as a promoter of carcinogenesis. C3H 10T1/2 mouse fibroblasts initiated with the carcinogen methylcholanthrene (INIT/10T1/2 cells) were used; in these cells, expression of the carcinogenic phenotype is suppressed indefinitely by the presence of retinyl acetate in the culture medium. After withdrawal of retinyl acetate, expression of the carcinogenic phenotype may be observed as the loss of contact inhibition. Cells grown without retinyl acetate were exposed to 0.1-0.8-mT (rms) 60 Hz magnetic fields or to sham fields. Eight days after exposure, magnetic-field and sham-exposed cells showed the same levels of incorporation of [3H]thymidine, and both had counts significantly higher than those of unexposed cells. The rate of incorporation of [3H]thymidine was very sensitive to small (0.1-0.8 degrees C) and transient (60 min) increases in incubation temperature during the first few days of withdrawal of retinyl acetate. Exposure of Jurkat (human acute T-cell lymphoma) and GH3 (rat pituitary tumor) cells to magnetic fields and sham conditions yielded similar results. INIT/10T1/2 cells cultured in the presence of retinyl acetate showed no effect of exposure conditions. Both magnetic-field and sham exposures caused a slight increase in temperature within the exposure zone in the incubator. Thus the differences between rates of incorporation of [3H]thymidine in magnetic field-exposed, sham-exposed and unexposed cells seem to be attributable at least in part to a slight elevation in temperature during exposure. Since some cells appear to be extremely sensitive to small increases in temperature, measurements of magnetic-field effects must be made and interpreted with caution.

Animals↗

Complex magnetic fields enable static magnetic field cue use for rats in radial maze tasks.

Male Wistar rats were trained in an eight-arm radial maze task (two sessions per day, delayed-non-matching-to-sample) that included an intramaze static magnetic field "cue" (185 microT) specific to the entrance point of one of the arms. Rats were exposed daily for 60 min to a complex magnetic field waveform (theta-burst pattern, 200-500 nT), presented with several different interstimulus intervals (ISIs), either immediately following training sessions or immediately preceding testing sessions. Application of the theta-burst stimulus with a 4000 ms ISI significantly improved the rats' memory for the arm of the radial maze whose position was indicated by the presence of a static magnetic field cue. Reference memory errors were homogeneously distributed among all eight arms of the maze for sham-exposed rats, and among the other seven arms of the maze for complex magnetic field-treated rats. These results suggest that static magnetic field cues may be salient orienting cues even in a microenvironment such as a radial maze, but their use as a cue during maze learning in rats is dependent on whole-body application of a specific time-varying complex magnetic field.

Animals↗

[The ecological-hygienic aspects of the study of industrial-frequency magnetic fields].

Magnetic fields of industrial frequency with magnetic flux density of 10 mkTl were studied for their effects on the morbidity pattern in the population of the settlement located in the vicinity of a high-voltage electric power line of 750 kV. A trend was noted towards increase in the incidence of nervous and endocrine diseases as well as metabolic disturbances and disorders of the immune system.

Ecology↗

The susceptibility of pure tubulin to high magnetic fields: a magnetic birefringence and x-ray fiber diffraction study.

The orientational behavior of microtubules assembled in strong magnetic fields has been studied. It is shown that when microtubules are assembled in a magnetic field, they align with their long axis parallel to the magnetic field. The effect of several parameters known to affect the microtubule assembly are investigated with respect to their effect on the final degree of alignment. Aligned samples of hydrated microtubules suitable for low-resolution x-ray fiber diffraction experiments have been produced, and the results obtained from the fiber diffraction experiments have been compared with the magnetic birefringence experiments. Comparisons with earlier fiber diffraction work and small-angle x-ray solution scattering experiments have been made.

Animals↗