PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Magnetic bead extraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Rapid diagnosis of enterovirus infection by magnetic bead extraction and polymerase chain reaction detection of enterovirus RNA in clinical specimens.

We describe a rapid method for extraction and detection of enterovirus RNA in clinical samples. By using magnetic bead technology, enterovirus RNA was efficiently and rapidly extracted from cerebrospinal fluid, stool, saliva, blood, pericardial fluid, urine, and cryopreserved or formalin-fixed solid tissue. Enterovirus RNA was then detected by reverse transcription followed by polymerase chain reaction amplification with primers designed to allow detection of most enterovirus serotypes. For detection of enteroviruses in specimens from patients with acute enteroviral disease, the overall sensitivity of enzymatic RNA amplification was greater than that of cell culture isolation, especially in blood specimens and in stool specimens from patients with acute cardiac disease. Enterovirus RNA was also detected in cryopreserved and archival formalin-fixed myocardial tissue from patients with acute myocarditis and chronic dilated cardiomyopathy. The ability to study archival specimens is of particular value in conducting retrospective investigation. The RNA extraction procedure used was considerably faster than extraction methods using organic reagents, used less hazardous reagents, and was of similar sensitivity. This detection protocol may therefore be useful both for the diagnosis of enterovirus infection and in studying the pathogenesis of acute and chronic enterovirus-induced disease.

Adult↗

Use of magnetic beads to extract fungal DNA.

Authors compare two methods of extracting DNA from different fungi: the classic method with phenol/chloroform (P/C) and that with magnetic beads. Both were tested on Candida albicans and Cryptococcus neoformans var. neoformans, belonging to the yeast group and Microsporum canis, M. gypseum, Trichophyton rubrum, T. interdigitale, T. ajelloi, Epidermophyton floccosum, belonging to the dermatophytes group. Extraction products underwent polymerase chain reaction (PCR) fingerprinting with the appropriate primers to point out any disagreement in the genomic profiles. After having determined that the genomic profiles obtained from the DNA extracted from the same strain with the two methods correspond perfectly, the authors concluded that the extraction method with magnetic beads from fungal cells is simpler and quicker than with P/C extraction, greatly facilitating the obtainment of fungal DNA.

Arthrodermataceae↗

Improving efficiency of a small forensic DNA laboratory: validation of robotic assays and evaluation of microcapillary array device.

AIM: To present validation studies performed for the implementation of existing and new technologies to increase the efficiency in the forensic DNA Section of the Palm Beach County Sheriff's Office (PBSO) Crime Laboratory. METHODS: Using federally funded grants, internal support, and an external Process Mapping Team, the PBSO collaborated with forensic vendors, universities, and other forensic laboratories to enhance DNA testing procedures, including validation of the DNA IQ magnetic bead extraction system, robotic DNA extraction using the BioMek2000, the ABI7000 Sequence Detection System, and is currently evaluating a micro Capillary Array Electrophoresis device. RESULTS: The PBSO successfully validated and implemented both manual and automated Promega DNA IQ magnetic bead extractions system, which have increased DNA profile results from samples with low DNA template concentrations. The Beckman BioMek2000 DNA robotic workstation has been validated for blood, tissue, bone, hair, epithelial cells (touch evidence), and mixed stains such as semen. There has been a dramatic increase in the number of samples tested per case since implementation of the robotic extraction protocols. The validation of the ABI7000 real-time quantitative polymerase chain reaction (qPCR) technology and the single multiplex short tandem repeat (STR) PowerPlex16 BIO amplification system has provided both a time and a financial benefit. In addition, the qPCR system allows more accurate DNA concentration data and the PowerPlex 16 BIO multiplex generates DNA profiles data in half the time when compared to PowerPlex1.1 and PowerPlex2.1 STR systems. The PBSO's future efficiency requirements are being addressed through collaboration with the University of California at Berkeley and the Virginia Division of Forensic Science to validate microcapillary array electrophoresis instrumentation. Initial data demonstrated the electrophoresis of 96 samples in less than twenty minutes. CONCLUSION: The PBSO demonstrated, through the validation of more efficient extraction and quantification technology, an increase in the number of evidence samples tested using robotic/DNA IQ magnetic bead DNA extraction, a decrease in the number of negative samples amplified due to qPCR and implementation of a single multiplex amplification system. In addition, initial studies show the microcapillary array electrophoresis device (microCAE) evaluation results provide greater sensitivity and faster STR analysis output than current platforms.

California↗

Use of 'long' polymerase chain reaction and magnetic beads for extraction of chromosome-specific cDNAs.

The detection of expressed sequences of genomic DNA is an important aspect of the human genome project. A technique is described where 'long' polymerase chain reaction (LPCR), which allows for extended large fragment production of > 10-20 kb, is used with Alu primers to generate a biotinylated template for cDNA hybridization. Streptavidin-coated magnetic beads are used to extract the long PCR templates and bound cDNAs, which are recovered by standard PCR. This method allows the isolation of cDNAs from virtually any human DNA source and should be valuable in expression mapping, positional cloning and gene isolation.

Base Sequence↗

Coupling of MALDI-TOF mass analysis to the separation of biotinylated peptides by magnetic streptavidin beads.

Extraction of biotinylated peptides by streptavidin magnetic beads has been directly coupled to the MALDI-TOF mass analysis. The elution of peptides from the beads is achieved by first mixing the beads with the MALDI matrix solution and removing, after a few minutes, the beads with a magnet; then, the matrix solution containing the biotinylated peptide is directly mass analyzed by MALDI. Three examples are presented to show the capabilities of this procedure to detect biotinylated peptides present at very low concentrations in complex mixtures. Detection limits of less than 100 finol can be achieved. Such a coupling strategy is of great interest to investigate peptide/ protein interactions.

Amino Acid Sequence↗

Gravity-driven millifluidic platform for magnetic solid-phase extraction of Enterocytozoon hepatopenaei DNA from complex shrimp hepatopancreas.

Effective detection of Enterocytozoon hepatopenaei (EHP) in aquaculture is currently hindered by the lack of field-deployable extraction methods capable of processing complex, inhibitor-rich hepatopancreatic tissue. This study presents a gravity-driven millifluidic platform for the rapid extraction of EHP genomic DNA using an optimized, surfactant-compatible magnetic solid-phase extraction (MSPE) chemistry. Utilizing 5% PEG 8000 and 2.0 M NaCl, the platform facilitates the selectively capture of DNA from inhibitor-rich crustacean lysates. The 3D-printed device employs a tilting rocking plate to generate passive, gravity-driven flow, maintaining homogeneous magnetic bead suspension and maximizing solid-phase capture efficiency without external pumps. The integrated platform achieved a DNA yield of 2804.33 ± 15.31 ng/μL, a 5.9-fold increase over manual magnetic bead extraction. TaqMan quantitative PCR (qPCR) validation targeting the EHP SSU rRNA gene was developed. Using a standard curve spanning 101 to 107 plasmid copies (Ct = -3.611 log10 [copy] + 42.309, R2 = 0.998, amplification efficiency 89.2%), the on-chip MSPE achieved a validated analytical limit of detection (LOD) of 1 spore per reaction (100% detection rate, n = 21), whereas a commercial CTAB-based DNA extraction kit failed to achieve a validated LOD even at 10 spores (85.7%, 18/21). Nested PCR targeting the SWP gene was employed for field evaluation. A pilot study across two cohorts (N = 40) demonstrated consistent detection of confirmed EPH-positive cases; however, the small sample size precludes definitive diagnostic accuracy claims. With a total processing time under 30 min, this platform provides a high-efficiency extraction module. Future work will couple the device with isothermal amplification (e.g., LAMP or RPA) to realize a sample-to-answer system for resource-limited aquaculture.

Aquaculture diagnostics↗

Use of magnetic beads versus guanidium thiocyanate-phenol-chloroform RNA extraction followed by polymerase chain reaction for the rapid, sensitive detection of enterovirus RNA.

The current study compares the sensitivity of RNA extraction using magnetic beads versus that of a standard extraction method. Streptavadin-coated magnetic beads were labelled with a biotinylated, enterovirus-specific oligonucleotide. RNA was extracted using labelled beads or guanidium thiocyanate-phenol-chloroform from 1, 0.1 and 0.01 TCID50/100 microliters of stock coxsackievirus types A9 and B3, echovirus type 11, enterovirus type 70 and poliovirus type 1. Each strain was tested three times. RNA extraction using magnetic beads was > 50% faster than the standard method. The RNA was amplified using RT-PCR, and the products were detected using agarose gel electrophoresis; 6/15 and 7/15 samples at an initial concentration of 0.01 TCID50/100 microliters were detected using magnetic beads or standard extraction, respectively. Negative-stain electron microscopy was used to determine that 0.01 TCID50/100 microliters of coxsackievirus B3 contained approximately 3 genomes. Thus, use of magnetic beads labelled with an enterovirus-specific oligonucleotide was less toxic, more rapid and as sensitive as the current standard RNA extraction method.

Chloroform↗

Use of magnetic beads for tissue DNA extraction and IS6110 Mycobacterium tuberculosis PCR.

Polymerase chain reaction (PCR) techniques are used increasingly for the diagnosis of Mycobacterium tuberculosis infection and can be used on the DNA obtained from both frozen and formalin fixed, paraffin wax embedded tissues. However, the extraction of DNA by means of the conventional phenol/chloroform method is time consuming and requires the use of potentially dangerous chemical reagents. This paper describes a method based upon the use of magnetic beads for the extraction of M tuberculosis DNA from both routinely formalin fixed, paraffin wax embedded tissues and frozen tissues. Magnetic bead extracted DNA from brain, lymph node, and lung tissues collected from patients with human immunodeficiency virus and tuberculosis was compared with that extracted using the phenol/chloroform method. The magnetic bead extraction procedure requires less than two hours, including the time necessary to dewax the tissue sections. In all cases, the DNA extracted with both methods was amplified successfully by PCR for the M tuberculosis IS6110 sequence. Magnetic bead DNA extraction can be used on both frozen and archival tissues: the method is reliable, simple, sensitive, and rapid; in addition, it does not use hazardous procedures or specialised laboratory equipment and can be used for routine DNA isolation from various human tissues.

Brain↗

Quantitation of HIV-1 RNA in breast milk by real time PCR.

HIV-1 RNA in breast milk is a strong predictor of HIV-1 transmission through breastfeeding. In the present report, breast milk samples from HIV-1 uninfected donors were spiked with dilution of quantified culture supernatant from HIV-1(NDK) infected PBMC. Two RNA extraction techniques based on silica extraction, Nuclisens (BioMerieux) and Triazol (Qiagen), two techniques based on guanidine thiocynanate/chloroforme extraction, TRIzol (Life Technologie) and Amplicor HIV-1 Monitor (Roche Diagnostic Systems), and one technique based on electrostatic adsorption on iron oxide micro beads (Promega) were compared. HIV-1 RNA was quantitated by real time PCR (LTR gene) and Amplicor HIV-1 Monitor. Combining magnetic micro beads extraction and real time PCR quantitation allowed to correctly quantify breast milk HIV-1 RNA, with a difference between the expected and measured HIV-1 RNA levels always lower than 0.3 log copies/ml. The same combination was confirmed on 25 breast milk samples from HIV-1 infected women collected in Kwazulu-Natal, South Africa, by comparing measurements with those obtained by the Amplicor HIV-1 Monitor (r(2)=0.88). Nucleic acid extraction by magnetic micro beads followed by real time PCR is a reliable, sensitive, rapid and simple procedure to quantify HIV-1 RNA in breast milk and allows for PCR inhibitors found frequently in these samples.

Female↗

Magnetic bead-based solid phase for selective extraction of genomic DNA.

Magnetic bead-based solid phases are widely used for the separation of nucleic acids from complex mixtures. The challenge to selectively separate specific DNA molecules (via complementary hybridization) in a single step is the selection of a linker between the capture probe and the solid support that can be exposed to high temperatures in the presence of a high salt media. This article presents a general platform for the fabrication of a magnetic bead-based selective solid phase that can be used for subtractive hybridization or sequence capture applications. Phosphorus dendrimers are used for the first time as linkers in a magnetic bead-based selective solid phase for capture of genomic DNA. Aside from providing a high loading capacity, they render a stable bond between the capture probe and the surface under the high temperature and salt conditions required for denaturation and capture to proceed in a single step. The thermal stability of the solid phase under these conditions is first demonstrated by hybridizing a Cy3-labeled target. The selective capture of DNA targets in a single step is then demonstrated by subtractive hybridization of fragmented human genomic DNA. The specificity and selectivity of the solid phase are demonstrated by the recovery of adenovirus serotype 4 DNA spiked into the human DNA target. The effect of steric and electrostatic constraints was also investigated by using dendrimers of different generations that vary in their size and the number of branches. The results demonstrate that this platform can be used for single-step subtractive hybridization applications with better performance over the conventional two-step method using streptavidin-coated magnetic beads.

Adenoviridae↗

High-volume extraction of nucleic acids by magnetic bead technology for ultrasensitive detection of bacteria in blood components.

BACKGROUND: Nucleic acid isolation, the most technically demanding and laborious procedure performed in molecular diagnostics, harbors the potential for improvements in automation. A recent development is the use of magnetic beads covered with nucleic acid-binding matrices. We adapted this technology with a broad-range 23S rRNA real-time reverse transcription (RT)-PCR assay for fast and sensitive detection of bacterial contamination of blood products. METHODS: We investigated different protocols for an automated high-volume extraction method based on magnetic-separation technology for the extraction of bacterial nucleic acids from platelet concentrates (PCs). We added 2 model bacteria, Staphylococcus epidermidis and Escherichia coli, to a single pool of apheresis-derived, single-donor platelets and assayed the PCs by real-time RT-PCR analysis with an improved primer-probe system and locked nucleic acid technology. Co-amplification of human beta(2)-microglobulin mRNA served as an internal control (IC). We used probit analysis to calculate the minimum concentration of bacteria that would be detected with 95% confidence. RESULTS: For automated magnetic bead-based extraction technology with the real-time RT-PCR, the 95% detection limit was 29 x 10(3) colony-forming units (CFU)/L for S. epidermidis and 22 x 10(3) CFU/L for E. coli. No false-positive results occurred, either due to nucleic acid contamination of reagents or externally during testing of 1030 PCs. CONCLUSIONS: High-volume nucleic acid extraction improved the detection limit of the assay. The improvement of the primer-probe system and the integration of an IC make the RT-PCR assay appropriate for bacteria screening of platelets.

Bacteriological Techniques↗

Nuclei that lack a lamina accumulate karyophilic proteins and assemble a nuclear matrix.

Xenopus egg extracts, which support nuclear assembly and DNA replication in vitro, were physically depleted of lamin B3 using monoclonal antibodies linked to magnetic beads. Depleted extracts were still able to support nuclear envelope assembly around demembranated sperm heads but the resulting pronuclei lacked a lamina and were unable to initiate semiconservative DNA replication or to assemble replicases, confirming previous data. Immunoblotting analysis of isolated nuclei and nuclear matrix fractions indicated that lamin-depleted nuclei still accumulated nucleoporins and PCNA. Furthermore, the rate of PCNA uptake was identical in lamin-depleted and control nuclei. However, neither the nucleoporins nor the PCNA was associated with nuclear matrix fractions. The major protein components of sperm pronuclear matrix fractions were characterized by two-dimensional gel electrophoresis. Of these proteins only three out of 22 species, other than the lamins, were significantly reduced in lamin-depleted nuclei, indicating that these nuclei do assemble a nuclear matrix.

Animals↗

Development of real-time detection direct test for hepatitis B virus and comparison with two commercial tests using the WHO international standard.

AIMS: A highly reproducible and sensitive hepatitis B virus real-time detection direct (HBV RTD-direct) test using DNA extraction by magnetic beads coated with polyclonal anti-HBsAg, followed by the real-time detection polymerase chain reaction (PCR) method, was developed for the detection of HBV DNA. METHODS: The HBV DNA could be extracted from the HBsAg positive viral particles without resulting in viral DNA fragmentation. The HBV RTD-direct test was validated using a serial dilution panel of the WHO standard HBV DNA 97/746 I. RESULTS: The test had a dynamic range of 0.7-8.0 log10 international units (IU) per mL and the results were shown to be comparable to those obtained with two commercially available tests: the HBV DNA transcription-mediated amplification-hybridization protection assay and the Amplicor HBV Monitor test. In addition, the HBV RTD-direct test, based on magnetic extraction, successfully eliminated PCR inhibitors in clinical specimens. CONCLUSION: We conclude that the HBV RTD-direct test is an excellent alternative for monitoring patients undergoing antiviral treatment or for screening various clinical specimens.

DNA, Viral↗

High-throughput extraction, amplification, and detection (HEAD) of HCV-RNA in individual blood donations.

BACKGROUND: High-throughput nucleic acid amplification techniques (NATs) are required for the detection of viral genomes in individual blood donations and might be helpful in any virological laboratory. OBJECTIVE: To develop and automate a method for the detection of hepatitis C virus RNA in individual blood donations, compatible with the time schedule of routine blood bank screening an product release. STUDY DESIGN: The viral RNA was isolated with the use of target specific capture oligonucleotides and magnetic beads. This extraction method was combined with reverse transcription/amplification (RT/PCR) and fluorescence detection. We adapted our method on a pipetting robot and pipetted all steps in a single room. When the pipetting was completed, microtiter plates were heat-sealed with foils and placed into a thermocycler. Positive reactions were detected with a fluorescent dye in a second room. Aerosols were avoided with programmed slow pipetting steps and with a special device constructed for the removal of the used disposable tips. During a 7 month period, we used this method in routine testing of individual donations prior to the release of all blood components. RESULTS: The total number of 11,700 individual donations including platelet concentrates were analysed. We tested up to 192 specimens in one run within 7 h. The frequency of cross-contamination using the automated procedure was 0.1%. Five specimens have been found repeatedly reactive for HCV-RNA, four of these were anti-HCV positive, one sample from a repeat donor was negative in anti-HCV assays. A seroconversion was detectable at his next presentation, 6 months later. CONCLUSION: In this pilot study, we demonstrate that automated HCV-RT-PCR testing is practicable for individual donations in high-throughput. Additionally, the described PCR approach could easily be adapted to the detection of other viral genomes by the use of specific primers.

Automation↗

DNA damage-dependent transcriptional arrest and termination of RNA polymerase II elongation complexes in DNA template containing HIV-1 promoter.

We have developed a new biochemical method to isolate a homogeneous population of RNA polymerase II (RNA pol II) elongation complexes arrested at a DNA damage site. The method involves triple-helix formation at a predetermined site in DNA template with a third strand labeled with psoralen at its 5'-end and a biotin at the 3'-end. After triplex formation and near-ultraviolet irradiation (360 nm), DNA templates modified with psoralen were immobilized on streptavidin-coated magnetic beads and used for in vitro transcription reactions with HeLa nuclear extracts. Separation of magnetic beads from solution results in isolation of arrested elongation complexes on the immobilized DNA templates. We have applied the method to arrest RNA pol II elongation complexes on a DNA template containing HIV-1 promoter. Our results indicate that psoralen crosslink in the template strand efficiently arrests elongation complexes, and psoralen monoadducts terminate transcription. Our results also demonstrate that a triple-helical structure stabilized by an intercalator, acridine, attached to the third strand of the helix inhibits transcription by a termination pathway. Isolation of stable RNA pol II elongation complexes arrested at DNA damage sites is a remarkable finding. This result demonstrates that arrested elongation complexes are impervious to DNA damage repair machinery and other regulatory proteins present in HeLa nuclear extracts. The method of delivering site-specific psoralen damage by a triplex structure and isolation of arrested RNA pol II elongation complexes should be generalizable to any promoter and DNA template sequences. This strategy provides a new approach to study the mechanism of transcription elongation and transcription-coupled DNA damage repair.

Base Sequence↗

HPV subtypes in cervical cancer biopsies between 1930 and 2004: detection using general primer pair PCR and sequencing.

Our objective was to investigate the practicability of sequencing DNA from formalin fixed, paraffin embedded tissue stored for up to 75 years and to study human papillomavirus subtype distribution in cervical neoplasias between 1931 and 2004. Three protocols for DNA retrieval were tested, and magnetic bead DNA extraction proved advantageous, as it gave superior specimen purity and effortless sequencing. Successful sequencing was achieved in more than 70% of the specimens from 1931 to 1960. This technique was utilized in the study of papillomavirus subtypes using general primer pair PCR with sequencing of the products in a series of 97 cases of neoplastic and non-neoplastic cervical specimens from 1931 to 1960 and 73 similar cases from 1992 to 2004. HPV was detected in 61% of neoplastic specimens from 1931 to 1960, and in 89% of those from 1992 to 2004. In specimens from 1931 to 1934, only HPV type 16 was detected, whereas in the specimens from 1940 and up, other HPV subtypes were identified in one-third of the cases. The difference was significant and suggests an increase in papillomavirus subtype heterogeneity in Western Norway during 1930-2000. The results strongly support the feasibility of using DNA from paraffin-embedded specimens for studying cancer etiology and genotypes over extended time periods.

Adult↗

In vitro selection of zinc finger DNA-binding proteins through ribosome display.

DNA-binding proteins with sequence specificities have a variety of applications. To create novel functional DNA-binding proteins, in vivo selection methods have been developed. There are, however, crucial problems with such methods, e.g., limitation of library size and difficulty of expression of toxic proteins for the host cells. In order to overcome these problems, we developed a novel way to select DNA-binding proteins using an in vitro ribosome display technique. The three zinc finger DNA-binding protein libraries, based on a Zif268 containing randomized sequence in each finger, were prepared and transcribed to mRNA in vitro. The ternary ribosomal complexes, formed by mRNA, ribosome, and translated DNA-binding protein during translation in a rabbit reticulocyte in vitro translation system, were selected with biotinylated target DNA fragments bound to streptavidin magnetic beads. The extracted mRNAs from the selected complexes were amplified using reverse transcription PCR and then sequenced. This is the first report of the selection of DNA-binding proteins involving an in vitro ribosome display technique.

Animals↗

Comparative study of methods for DNA preparation from olive oil samples to identify cultivar SSR alleles in commercial oil samples: possible forensic applications.

Virgin olive oil is made from diverse cultivars either mixed or single. Those ensure different tastes and typicity, and these may be also enhanced by the region of production of cultivars. The different olive oil labels correspond to their chemical composition and acidity. Labels also may correspond to a protected origin indication, and thus, such oils contain a given composition in cultivars. To verify the main cultivars used at the source of an olive oil sample, our method is based on DNA technology. DNA is present in all olive oil samples and even in refined oil, but the quantity may depend on the oil processing technology and oil conservation conditions. Thus, several supports were used to retain DNA checking different techniques (silica extraction, hydroxyapatite, magnetic beads, and spun column) to prepare DNA from variable amounts of oil. At this stage, it was usable for amplification through PCR technology and especially with the magnetic beads, and further purification processes were checked. Finally, the final method used magnetic beads. DNA is released from beads in a buffer. Once purified, we showed that it did not contain compounds inhibiting PCR amplification using SSR primers. Aliquot dilution fractions of this solution were successfully routinely used through PCR with different SSR primer sets. This enables confident detection of eventual alien alleles in oil samples. First applied to virgin oil samples of known composition, either single cultivars or mixtures of them, the method was verified working on commercial virgin oil samples using bottles bought in supermarkets. Last, we defined a protocol starting from 2 x 40 mL virgin olive oil, and DNA was prepared routinely in about 5 h. It was convenient to genotype together several loci per sample to check whether alleles were in accordance with those of expected cultivars. Thus, forensic applications of our method are expected. However, the method needs further improvement to work on all oil samples.

Alleles↗