Radiosurgery for residual or recurrent nonfunctioning pituitary adenoma.

OBJECT: Nonfunctioning pituitary adenomas comprise approximately 30% of all pituitary tumors. The purpose of this retrospective study is to evaluate the efficacy and role of gamma knife radiosurgery (GKS) in the management of residual or recurrent nonfunctioning pituitary adenomas. METHODS: A review was conducted of the data obtained in 42 patients who underwent adjuvant GKS at the University of Pittsburgh between 1987 and 2001. Prior treatments included transsphenoidal resection, craniotomy and resection, or conventional radiotherapy. Endocrinological, ophthalmological, and radiological responses were evaluated. The duration of follow-up review varied from 6 to 102 months (mean 31.2 months). Fifteen patients were observed for more than 40 months. The mean radiation dose to the tumor margin was 16 Gy. Conformal radiosurgery planning was used to restrict the dose to the optic nerve and chiasm. Tumor control after GKS was achieved in 100% of patients with microadenomas and 97% of patients with macroadenomas. Gamma knife radiosurgery was equally effective in controlling adenomas with cavernous sinus invasion and suprasellar extension. No patient developed a new endocrinological deficiency following GKS. One patient's tumor enlarged with an associated decline in visual function. Another patient experienced a deterioration of visual fields despite a decrease in tumor size. CONCLUSIONS: Gamma knife radiosurgery can achieve tumor control in virtually all residual or recurrent nonfunctioning pituitary adenomas. Dose sparing facilitates tumor management even when the adenoma is close to the optic apparatus or invades the cavernous sinus.

Adenoma↗

Gamma knife radiosurgery as a primary treatment for prolactinomas.

OBJECT: The purpose of this study was to estimate the efficacy of gamma knife radiosurgery (GKS) in controlling tumor growth and endocrinopathy associated with prolactinomas. METHODS: Between 1993 and 1997, 164 of 469 patients with pituitary adenomas treated by GKS harbored prolactinomas. The dose to the tumor margin ranged from 9 to 35 Gy (mean 31.2 Gy), and the visual pathways were exposed to a dose of less than 10 Gy. The mean tumor diameter was 13.4 mm. The mean follow-up time for 128 cases was 33.2 months (range 6-72 months). Tumor control was observed in all but two patients who underwent surgery 18 and 36 months, respectively, after GKS. Clinical cure was achieved in 67 cases. Clinical improvement was noted with a decrease in the hyperprolactinemia after GKS. Nonetheless, in 31 (29%) of 108 patients who were followed for more than 2 years no improvement in serum prolactin levels was demonstrated, although this could be normalized by bromocriptine administration after treatment. Nine infertile women became pregnant 2 to 13 months after GKS and all gave birth to normal children. There was no visual deterioration related to GKS. Five women experienced premature menopause. In these patients there was subtotal disappearance of the tumor and an empty sella developed. CONCLUSIONS: Gamma knife radiosurgery as a primary treatment for prolactinomas can be safe and effective both for controlling tumor growth and for normalization of prolactin hypersecretion. A higher margin dose (> or = 30 Gy) seemed to be associated with a better clinical outcome. Gamma knife radiosurgery may make prolactinomas more sensitive to the bromocriptine.

Humans↗

[Magnetically based enhancement of nanoparticle uptake in tumor cells: combination of magnetically induced cell labeling and magnetic heating].

PURPOSE: Magnetic nanoparticles (MNP) are known to be versatile tools in diagnostic and interventional radiology. The goal of the present study was to assess whether MNP can be selectively accumulated on human adenocarcinoma cells in vitro using an external magnetic field (magnetically induced cell labeling) and whether these labeled tumor cells can then be destroyed after being exposed to an alternating magnetic field (magnetically induced heating). In this context, a long-term goal is to combine these two developing methods to achieve an additive effect in tumor therapy. MATERIALS AND METHODS: BT-474 cells were incubated until confluence. Magnetic nanoparticles (0.32 mg Fe/ml culture medium) were then added and the flask was exposed to an external magnetic field gradient (magnetically induced cell labeling, 56 or 83 mT magnets) for 24 hours in order to label the tumor cells with nanoparticles. Cells without both MNP and magnetic labeling as well as cells with MNP incubation but without magnetic labeling served as controls. After MNP incubation, the magnetically labeled cells (5 x 10 (7) cells/ml) were exposed to an alternating magnetic field for 5.45 minutes (frequency 400 kHz, amplitude 24.6 kA/m). The combination effect of both magnetic labeling and magnetic heating was assessed by determining the temperature increase. The amount of MNP accumulated within the cells was determined by measuring the iron content via atomic absorption spectrometry. For statistical analysis mean values and standard deviations of temperature increases and iron contents were calculated and the differences were analyzed using the Student's t-test. RESULTS: A significant temperature increase (p < 0.01) during magnetic heating of 41.76 +/- 4.60 K was detected after magnetic labeling of the cells (5 x 10 (7) cells/ml, 83 mT) incubated with MNP. In comparison, the cells incubated with MNP but without magnetic labeling revealed a temperature increase of 32.03 +/- 3.33 K, naked cells of only 2.69 +/- 0.34 K. CONCLUSION: The results demonstrated the magnetically based enhancement of cellular uptake of nanoparticles by tumor cells, resulting in the intensification of the generated temperature increase during magnetic heating. Consequently, magnetic nanoparticles are shown to be valuable tools for the combination of magnetically based therapy modalities.

Adenocarcinoma↗

Evidence for single-chain magnet behavior in a Mn(III)-Ni(II) chain designed with high spin magnetic units: a route to high temperature metastable magnets.

We herein present the synthesis, crystal structure, and magnetic properties of a new heterometallic chain of MnIII and NiII ions, [Mn2(saltmen)2Ni(pao)2(py)2](ClO4)2 (1) (saltmen2- = N,N'-(1,1,2,2-tetramethylethylene) bis(salicylideneiminate) and pao- = pyridine-2-aldoximate). The crystal structure of 1 was investigated by X-ray crystallographic analysis: compound 1 crystallized in monoclinic, space group C2/c (No. 15) with a = 21.140(3) A, b = 15.975(1) A, c = 18.6212(4) A, beta = 98.0586(4) degrees , V = 6226.5(7) A3, and Z = 4. This compound consists of two fragments, the out-of-plane dimer [Mn2(saltmen)2]2+ as a coordination acceptor building block and the neutral mononuclear unit [Ni(pao)2(py)2] as a coordination donor building block, forming an alternating chain having the repeating unit [-Mn-(O)2-Mn-ON-Ni-NO-]n. In the crystal structure, each chain is well separated with a minimum intermetallic distance between Mn and Ni ions of 10.39 A and with the absence of interchain pi overlaps between organic ligands. These features ensure a good magnetic isolation of the chains. The dc and ac magnetic measurements were performed on both the polycrystalline sample and the aligned single crystals of 1. Above 30 K, the magnetic susceptibility of this one-dimensional compound was successfully described in a mean field approximation as an assembly of trimers (Mn...Ni...Mn) with a NiII...MnIII antiferromagnetic interaction (J = -21 K) connected through a ferromagnetic MnIII...MnIII interaction (J'). However, the mean field theory fails to describe the magnetic behavior below 30 K emphasizing the one-dimensional magnetic character of the title compound. Between 5 and 15 K, the susceptibility in the chain direction was fitted to a one-dimensional Ising model leading to the same value of J'. Hysteresis loops are observed below 3.5 K, indicating a magnet-type behavior. In the same range of temperature, combined ac and dc measurements show a slow relaxation of the magnetization. This result indicates the presence of a metastable state without magnetic long-range order. This material is the first experimental design of a heterometallic chain with ST = 3 magnetic units showing a "single-chain magnet" behavior predicted in 1963 by R. J. Glauber for an Ising one-dimensional system. This work opens new perspectives for one-dimensional systems to obtain high temperature metastable magnets by combining high spin magnetic units, strong interunit interactions, and uniaxial anisotropy.

Journal Article↗

The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds.

The concept of magnetic susceptibility is central to many current research and development activities in magnetic resonance imaging (MRI); for example, the development of MR-guided surgery has created a need for surgical instruments and other devices with susceptibility tailored to the MR environment; susceptibility effects can lead to position errors of up to several millimeters in MR-guided stereotactic surgery; and the variation of magnetic susceptibility on a microscopic scale within tissues contributes to MR contrast and is the basis of functional MRI. The magnetic aspects of MR compatibility are discussed in terms of two levels of acceptability: Materials with the first kind of magnetic field compatibility are such that magnetic forces and torques do not interfere significantly when the materials are used within the magnetic field of the scanner; materials with the second kind of magnetic field compatibility meet the more demanding requirement that they produce only negligible artifacts within the MR image and their effect on the positional accuracy of features within the image is negligible or can readily be corrected. Several materials exhibiting magnetic field compatibility of the second kind have been studied and a group of materials that produce essentially no image distortion, even when located directly within the imaging field of view, is identified. Because of demagnetizing effects, the shape and orientation, as well as the susceptibility, of objects within and adjacent to the imaging region is important in MRI. The quantitative use of susceptibility data is important to MRI, but the use of literature values for the susceptibility of materials is often difficult because of inconsistent traditions in the definitions and units used for magnetic parameters-particularly susceptibility. The uniform use of SI units for magnetic susceptibility and related quantities would help to achieve consistency and avoid confusion in MRI.

Biophysical Phenomena↗

Nature of copper(II)-lanthanide(III) magnetic interactions and generation of a large magnetic moment with magnetic anisotropy of 3d-4f cyclic cylindrical tetranuclear complexes [CuIILLnIII(hfac)2]2, (H3L = 1-(2-hydroxybenzamido)-2-(2-hydroxy-3-methoxybenzylideneamino)ethane and Hhfac = hexafluoroacetylacetone, LnIII = Eu, Gd, Tb, Dy).

A cyclic cylindrical 3d-4f tetranuclear structure, in which the 3d and 4f magnetic ions are arrayed alternately, has been found to be a suitable molecular design to produce a large magnetic moment and large magnetic anisotropy. Complexes 3-10 with the chemical formula [MLLn(hfac)2]2 ((MII, LnIII) = (Cu, Eu) (3), (Cu, Gd) (4), (Cu, Tb) (5), (Cu, Dy) (6), (Ni, Eu) (7), (Ni, Gd) (8), (Ni, Tb) (9), (Ni, Dy) (10)) have been synthesized, where H3L = 1-(2-hydroxybenzamido)-2-(2-hydroxy-3-methoxybenzylideneamino)ethane and Hhfac = hexafluoroacetylacetone. The powder X-ray diffractions and FAB-mass spectra demonstrated that these complexes assume a similar tetranuclear structure. The crystal structures of 4 and 5 showed that each complex has a cyclic cylindrical tetranuclear CuII2LnIII2 structure, in which the CuII complex functions as a "bridging ligand-complex" to two adjacent LnIII ions. The temperature-dependent magnetic susceptibilities from 2 to 300 K and the field-dependent magnetizations at 2 K from 0 to 5 T have been measured for four pairs of CuII2LnIII2 and NiII2LnIII2, in which compound NiII2LnIII2 containing diamagnetic NiII ion was used as the reference complex to evaluate the CuII-LnIII magnetic interaction. Comparison of the magnetic properties of the CuII2LnIII2 complex with those of the corresponding NiII2LnIII2 complex showed that the magnetic interaction between CuII and EuIII ions is weakly ferromagnetic and that between CuII and either of GdIII, TbIII, and DyIII ions is ferromagnetic. Complex CuII2GdIII2, 4, has an S = 8 spin ground state, due to the ferromagnetic spin coupling between SGd = 7/2 and SCu = 1/2 with coupling constants of J1 = +3.1 cm-1 and J2 = +1.2 cm-1. The magnetic measurements showed that compounds 5 and 6, CuII2LnIII2 (LnIII = Tb, Dy), exhibit large magnetic moments and large magnetic anisotropy due to the LnIII ion.

Journal Article↗

Biomedical applications of magnetic fluids II. 1) preparation and magnetic guidance of magnetic albumin microsphere for site specific drug delivery in vivo.

Magnetic guidance of magnetic albumin microsphere for site specific delivery was investigated in mice and rats. After intravenous injection in mice, magnetic microspheres with 1 and 3 micrometer diameter size were localized and retained in the target-site (lung) by application of two permanent magnets to the lungs. Injection into the renal artery in rats also indicated that the 1-micrometer microspheres were concentrated in the kidney by a magnetic field. When the magnets were not applied, however, the microspheres following intravascular injection were concentrated mainly in the liver, regardless of the route of administration. Such preferential localization by magnetic means suggested that magnetic albumin microspheres could become effective drug carriers with site specificity for the delivery of chemotherapeutic agents in cancer therapy.

Animals↗

Estimation of magnetic particle clustering in magnetic fluids from static magnetization experiments.

The volume fraction dependence of the static magnetization of two magnetic fluids with different degrees of steric stabilization was measured at low field values (0-10 kA/m) and it was found to be nonlinear for both magnetic fluids. The nonlinearity is more pronounced in the case of the less stabilized magnetic fluid. The experimental data were processed by nonlinear regression using an analytical model for the formation of chain-like magnetic particle aggregates in magnetic fluids. The calculated dependence on the degree of steric stabilization, magnetic field, and sample concentration of the mean number of particles per chain was in the range (1-1.04).

Journal Article↗

Characterization of the crystal and magnetic structures of the mixed-anion coordination polymer Cu(HCO2)(NO3)(pyz) {pyz = Pyrazine} by X-ray diffraction, ac magnetic susceptibility, dc magnetization, muon-spin relaxation, and spin dimer analysis.

The mixed-anion coordination polymer Cu(HCO2)(NO3)(pyz) was synthesized, its crystal structure was determined by X-ray diffraction, and its magnetic structure was characterized by ac susceptibility, dc magnetization, muon-spin relaxation, and spin dimer analysis. The crystal structure consists of five-coordinate Cu2+ ions that are connected through syn-anti bridging mu-HCO2- and mu-pyz ligands to form a highly corrugated two-dimensional layered network. Bulk magnetic measurements show a broad maximum in chi(T) at 6.6 K. The HCO2- and pyz ligands mediate ferromagnetic and antiferromagnetic spin exchange interactions between adjacent Cu2+ ions with the spin exchange parameters J/kB = 8.17 and -5.4 K, respectively (H = -JSigmaSi x Sj). The muon-spin relaxation data show a transition to a long-range magnetic ordering below TN = 3.66(3) K. For T < TN, the M(H) and chi'ac measurements provide evidence for a field-induced spin-flop transition at 15.2 kOe. That Cu(HCO2)(NO3)(pyz) undergoes a long-range magnetic ordering is an unexpected result because the one-dimensional Cu(NO3)2(pyz) and three-dimensional Cu(HCO2)2(pyz) compounds display linear chain antiferromagnetism with no long-range magnetic ordering down to 2 K.

Journal Article↗

[ECG changes caused by the effect of static magnetic fields of nuclear magnetic resonance tomography using magnets with a field power of 0.5 to 4.0 Telsa].

ECG-alterations under the influence of static magnetic fields were investigated in phantoms (1.5 Tesla), animals and volunteers (4.0 Tesla), as well as in 12 patients (0.5, 1.0, and 1.5 Tesla). Under the influence of static magnetic fields high- and low-frequency voltages are superimposed on the ECG. Motions of the electrical leads induce high-frequency waves, which can alter the ECG to the extent that only the QRS-complex can be recognized. Electrolytes moved by the blood stream in static magnetic fields also induce voltages (Hall-effect) which, according to the patient's position, result in ST-segment- and partial T-wave-elevations or depressions. All ECG-alterations are reversible after exposition to the static magnetic field. Rhythm disturbances do not occur. The results indicate that static magnetic fields up to 4.0 Tesla do not have permanent adverse effects on the human ECG.

Adult↗

An EPR method for probing surface magnetic fields, dipolar distances, and magnetization fluctuations in single molecule magnets.

We outline a spectroscopic method for probing the effective magnetic field B on the surface of crystals of the single molecule magnet (SMM) [(C6H15N3)6Fe8(mu3-O)2(mu2-OH)12]Br7(H2O)Br.H2O, (Fe8Br8). This technique utilizes the line shape changes in the EPR spectra of the organic radical 2,2-diphenyl-1-picrylhydrazyl (DPPH) (g = 2.0036, single peak) adsorbed onto the sample. The temperature dependence of the EPR line shifts scale with the sample's magnetization as measured by a SQUID magnetometer. Analysis of the line shape in terms of dipolar coupling between the DPPH and the SMM molecules on the surface, yields their average dipolar distance. The method's potential for measuring the magnetization fluctuation dynamics is briefly pointed out using the SMM [Mn12O12(CH3COO)16(H2O)4].2CH3COOH.4H2O (Mn12-acetate).

Adsorption↗

Three dimensional magnetic resonance imaging by magnetic resonance force microscopy with a sharp magnetic needle.

An electropolished magnetic needle made of Nd(2)Fe(14)B permanent magnet was used for obtaining better spatial resolution than that achieved in our previous work. We observed the magnetic field gradient |G(Z)|=80.0G/microm and the field strength B=1250G at Z approximately 8.8 microm from the top of the needle. The use of this needle for three dimensional magnetic resonance force microscopy at room temperature allowed us to achieve the voxel resolution to be 0.6 microm x 0.6 microm x 0.7 microm in the reconstructed image of DPPH phantom. The acquisition time spent for the whole data collection over 64 x 64 x 16 points, including an iterative signal average by six times per point, was about 10 days.

Journal Article↗

Spin dynamics of the radical pair in a low magnetic field studied by the transient absorption detected magnetic field effect on the reaction yield and switched external magnetic field.

The spin dynamics of the radical pair generated from the photocleavage reaction of (2,4,6-trimethylbenzoyl)diphenylphosphine oxide (TMDPO) in micellar solutions was studied by the time-resolved magnetic field effect (MFE) on the transient absorption (TA) and by a novel technique, absorption detected switched external magnetic field (AD-SEMF). Thanks to the large hyperfine coupling constant (A = 38 mT), a characteristic negative MFE on the radical yield was observed at a magnetic field lower than 60 mT whereas a positive effect due to the conventional hyperfine (HFM) and relaxation mechanisms (RM) was observed at higher magnetic field. The negative effect can be assigned to the mechanism "so-called" low field effect (LFE) mechanism and has been analyzed thoroughly using a model calculation incorporating a fast spin dephasing process. The time scale of the spin mixing process of LFE studied by AD-SEMF is shorter than the lifetime of the recombination kinetics of the radical pair. These results indicate that the LFE originates from the coherent spin motion. This can be interfered from the fast spin dephasing caused by electron spin interaction fluctuations.

Journal Article↗

Magnetic-field induced transition to the 1/2 magnetization plateau state in the geometrically frustrated magnet CdCr2O4.

The magnetization of the geometrically frustrated spinel CdCr2O4 was measured in pulsed fields of up to 47 T. We found a metamagnetic transition to a very wide magnetization plateau state with one half of the full moment of S=3/2 Cr3+ at 28 T, independent of the field direction. This is the first observation of magnetization plateau state realized in Heisenberg pyrochlore magnet. The plateau state can be ascribed to a collinear spin configuration with three-up and one-down spins out of four spins of each Cr tetrahedron. A large magnetostriction is observed at the transition in spite of the negligible spin-orbit couplings. We argue that spin frustration plays a vital role in this large spin-lattice coupling.

Journal Article↗

[Dynamic magnetic resonance of the knee. Considerations on techniques and anatomy with a magnetic resonance system with open magnet].

MRI is currently considered the best technique to study the joints--knee joints in particular. Most studies are performed with the knee straightened out or slightly flexed, which position is mandatory with contemporary MR units. Recently, however, the MR equipment for limb studies and the larger tunnels of total body magnets have permitted partially dynamic knee studies, up to 30-40 degrees flexion; this joint excursion cannot be exceeded. In 1996, Muhle and Niitsu demonstrated that dynamic MRI can be useful to study cruciate ligament injuries, some types of meniscal injuries, all femoropatellar conditions and, mostly, cruciate ligament reconstruction. We used an open magnet MR unit for thorough functional dynamic knee studies, acquiring the images at 0-120 degrees flexion. The open magnet MR unit permits free joint movements. We examined 25 subjects: 10 healthy volunteers and 15 patients with meniscal, capsuloligamentous, femoropatellar or synovial conditions. This technique schedules axial, coronal or sagittal images, according to the diagnostic suspicion, suitably directed with the patient in lateral decubitus and with the knee flexed to maximum joint excursion. Dynamic MR findings are easily transferred to an X-ray film, so that the radiologist can send them to the orthopedist with no need of any videotape or TV take. The current cine MR programs display the dynamic images of the moving joint on an MR monitor, but this option is not yet widely available. The quality of dynamic MR studies is exactly the same as that of conventional images, with a particular emphasis on the small diagnostic details of the injuries. We report our preliminary experience with this technique, indicating some possible clinical applications of dynamic MRI which permits thorough studies of knee flexion-extension.

Humans↗

Magnetism without magnetic ions: percolation, exchange, and formation energies of magnetism-promoting intrinsic defects in CaO.

We investigate theoretically the prospects of ferromagnetism being induced by cation vacancies in nonmagnetic oxides. A single Ca vacancy V(0)(Ca) has a magnetic moment due to its open-shell structure but the ferromagnetic interaction between two vacancies extends only to four neighbors or less. To achieve magnetic percolation on a fcc lattice with such an interaction range one needs a minimum of 4.9% vacancies, or a concentration 1.8 x 10(21) cm(-3). Total-energy calculations for CaO show, however, that due to the high vacancy formation energy even under the most favorable growth conditions one can not obtain more than 0.003% or 10(18) cm(-3) vacancies at equilibrium, showing that a nonequilibrium vacancy-enhancement factor of 10(3) is needed to achieve magnetism in such systems.

Journal Article↗

Hartree-Fock study of orbital magnetic moments in 3d and 5f magnets and X-ray magnetic circular dichroism.

The spin (Ms) and orbital magnetic moments (Mo) of the uranium 5f state in the ferromagnetic compound uranium sulfide (US) and of the cobalt 3d state in various transition-metal superlattices are calculated on the basis of a tight-binding model, in which the intra-atomic f-f or d-d multipole interaction is taken into account using the Hartree-Fock (HF) approximation. The parameters in the model are determined on the basis of available first-principles calculations. For US, the calculated ratio Mo/Ms and magnetic circular dichroism spectrum for U M4,5 absorption are in good agreement with the experimental results. Inclusion of the expectation values of the spin-off-diagonal operators in addition to the number operators in the 5f state is found to be crucially important when describing the 5f magnetic state. A difference in enhancement of Mo of the Co atom between the Co/Pd and Co/Cu superlattices is discussed on the basis of a semi-quantitative calculation, assuming ferromagnetism.

Journal Article↗

Liver iron concentration evaluated by two magnetic methods: magnetic resonance imaging and magnetic susceptometry.

Quantification of liver iron concentration (LIC) is crucial in the management of patients suffering from certain pathologies that can produce iron overload, such as Cooley's anemia and hemochromatosis. All of these patients must control the level of iron deposits in their organs to avoid the toxicity of high LIC, which is potentially lethal. This paper describes experimental protocols for LIC measurement using two magnetic techniques: magnetic resonance imaging (MRI) and biomagnetic liver susceptometry (BLS). MRI proton transverse relaxation rate (R2) and image intensity, evaluated pixel by pixel, were used as indicators of iron load in the tissue. LIC measurement by BLS was performed using an AC superconducting susceptometer system. A group of 23 patients with a large range of iron overload (0.9 to 34.5 mgFe/g(dry tissue)) was evaluated with both techniques (MRI x BLS). A significant linear correlation (r = 0.89-0.95) was found between the LIC by MRI and by BLS. These results show the feasibility of using two noninvasive methodologies to evaluate liver iron store in a large concentration range. Both methodologies represent an equivalent precision.

Adolescent↗