PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Methylmethacrylate”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Methylmethacrylate metabolism in man. The hydrolysis of methylmethacrylate to methacrylic acid during total hip replacement.

Methylmethacrylate, the monomeric component of the polymethylmethacrylate cement used in orthopedic surgery, has been shown to undergo hydrolysis to methacrylic acid during hip replacement operations. Circulating levels of methacrylic acid were comparable with those of methylmethacrylate. Concentrations of both methylmethacrylate and methacrylic acid normally lay in the range 0--15 micrograms/cc. No correlation could be discerned between changes in the concentrations of methylmethacrylate and methacrylic acid, and changes in blood pressure.

Acetabulum↗

Serum and breast milk levels of methylmethacrylate following surgeon exposure during arthroplasty.

BACKGROUND: Although pregnant personnel are commonly encouraged to leave the operating room during the mixing and application of polymethylmethacrylate, we are not aware of any information regarding the safety of exposure to methylmethacrylate fumes for breastfeeding women. The present study was performed to investigate the concentrations of methylmethacrylate in serum and breast milk following exposure during total joint arthroplasty. METHODS: A survey designed to determine present-day attitudes to polymethylmethacrylate exposure during pregnancy and lactation was sent to members of the Ruth Jackson Orthopaedic Society and the National Association of Orthopaedic Nurses. To define the presence or absence of a scientific basis for this behavior, serum and breast milk samples were collected from two lactating surgeons at selected intervals after exposure to methylmethacrylate during eight total joint arthroplasty procedures. Two healthy breastfeeding women without exposure to methylmethacrylate served as controls. All twenty-five samples were analyzed for methylmethacrylate with use of a previously published headspace gas chromatography protocol. RESULTS: The gas chromatography protocol detected methylmethacrylate at levels as low as 0.5 part per million. No serum or breast milk sample demonstrated evidence of methylmethacrylate at that level, nor did any surgeon sample test at a higher level than the control specimens. Serum and milk samples spiked with methylmethacrylate yielded the analyte peak as expected, evidencing no interference from either matrix. CONCLUSIONS: Methylmethacrylate was not detectable at the 0.5-part-per-million level in serum or breast milk following inhalational exposure during total joint arthroplasty. Although a controlled longitudinal relative risk analysis was not performed and the sample size was relatively small, pregnant or breastfeeding women may use this information to make an informed decision regarding such exposure. LEVEL OF EVIDENCE: Therapeutic Level II.

Adult↗

Methylmethacrylate monomer produces direct relaxation of vascular smooth muscle in vitro.

Methylmethacrylate bone cement is associated with severe hypotensive reactions during surgery and anesthesia. The purpose of this in vitro study was to determine if methylmethacrylate monomer could produce hypotension by acting directly on vascular smooth muscle. Segments of human saphenous vein or rabbit thoracic aorta were cut into rings. The rings were mounted in isolated tissue chambers in order to measure isometric tension development. Methylmethacrylate monomer (methylmethacrylic acid ester) produced direct relaxation of venous or aortic rings preconstricted with either potassium ion or noradrenaline. The relaxation was concentration-dependent, occurring at concentrations from 10(-3) to 10(-1) M. The relaxation of rabbit aortic rings (preconstricted with noradrenaline) was unaffected by pre-treatment with atropine, propranolol, cimetidine, indomethacin, or methylene blue. Endothelial stripping with Triton X-100, sufficient to completely abolish acetylcholine-induced relaxation, also had little effect on methylmethacrylate-induced relaxation. Methylmethacrylate produced direct relaxation of rabbit aortic rings constricted with either potassium or noradrenaline in calcium-deficient media, and inhibited subsequent calcium-induced constriction. These results suggest that methylmethacrylate monomer may interfere with intracellular and extracellular calcium mobilization and excitation/contraction coupling in vascular smooth muscle. The direct relaxation of venous and arterial smooth muscle produced by methylmethacrylate monomer may contribute in part to the hypotension that can occur when acrylic bone cement is employed during orthopedic procedures.

Animals↗

The effect of methylmethacrylate on chemotaxis of polymorphonuclear leukocytes.

The effect of methylmethacrylate on chemotaxis of polymorphonuclear leukocytes was evaluated by an in vitro method that involved migration of human leukocytes under agarose. Chemotactic factors produced during growth of Staphylococcus epidermidis, Staphylococcus aureus, and Escherichia coli remained chemotactically active in the presence of a methylmethacrylate concentration of 1.25 per cent, which was the highest tested. The methylmethacrylate also did not alter the activity of the chemotactic factor produced by zymosan activation of normal human serum. However, when methylmethacrylate was added to normal human serum prior to zymosan activation, a methylmethacrylate concentration of 0.312 per cent significantly depressed the subsequent zymosan-induced chemotactic activity and concentrations above 0.312 per cent abolished it. When methylmethacrylate was added to the polymorphonuclear leukocyte suspensions, there was significant depression of the migration of cells at a concentration of 0.312 per cent, and at concentrations of 0.625 and 1.25 per cent no leukocyte migration occurred.

Cell Migration Inhibition↗

Methylmethacrylate is a mutagen for Salmonella typhimurium.

The long-term effects of exposure to monomeric methylmethacrylate have yet to be established. We have measured the toxicity and mutagenicity of methylmethacrylate for Salmonella typhimurium. At levels of thirty-four millimolar, methylmethacrylate exhibited 28 per cent of the mutagenic activity of an equimolar dose of dimethylnitrosamine. Methylmethacrylate alone exhibited toxicity to the bacteria, but when the methylmethacrylate was incubated with a rat-liver enzyme metabolizing system, mutagenesis was induced. These findings suggest that an intermediate metabolite of methylmethacrylate is mutagenic to Salmonella typhimurium.

Adhesives↗

Methylmethacrylate monomer and fat content in shed blood after total joint arthroplasty.

Twenty-five patients were prospectively evaluated to quantify levels of methylmethacrylate monomer and fat in systemic blood and in shed blood after total joint arthroplasty. Levels of methylmethacrylate monomer in systemic blood were measured at intervals after insertion of the prosthesis. Levels of methylmethacrylate monomer in shed blood were measured at intervals after insertion of the drain. Levels of fat in systemic blood were measured preoperatively and 30 minutes after insertion of the prosthesis. Levels of fat in shed blood were measured 60 minutes after insertion of the drain. No significant fat or methylmethacrylate monomer was noted in systemic blood. Levels of methylmethacrylate monomer in shed blood were highest five minutes after insertion of the drain. Levels of methylmethacrylate monomer in shed blood collected from the hip were significantly lower than levels in shed blood from the knee. Levels of shed blood from the hip and knee were undetectable six hours after insertion of the drain. Shed blood from the hips and knees contained fat particles of three diameters: fat particles less than 9 microns, 9-40 microns, and greater than 40 microns. The diameter of most of the fat particles in the shed blood was less than 9 microns. Fat particles less than 40 microns in diameter will not be removed by microaggregate screen filters 40 microns in diameter.

Blood Loss, Surgical↗

Cardiovascular collapse associated with the use of methylmethacrylate.

Methylmethacrylate has been used extensively in the United States since 1971 for the fixation of orthopedic prostheses. A chemical compound that generates a considerable amount of heat as it sets and hardens, it has been known to cause mild to moderate hypotension as well as cardiovascular collapse and death in some instances. Some of the purported etiologies of the untoward effects of methylmethacrylate include fat embolism, air embolism, bone marrow embolism, peripheral vasodilation, activation within the lungs of the clotting cascade, direct cardiovascular depressant effects of methylmethacrylate cement or monomer, and others. In this article, the use of methylmethacrylate in orthopedic procedures is reviewed, along with a discussion of some of the previously hypothesized causes of its side effects. Then a case report of its use in a 59-year-old woman with a pathological fracture of her left femur is presented. Finally, the implications for the anesthetist are noted, and suggested interventions to limit untoward effects with the use of methylmethacrylate are presented.

Female↗

Root and spinal cord compression from methylmethacrylate vertebroplasty.

STUDY DESIGN: Case report and literature review. OBJECTIVES: Clinicians use methylmethacrylate vertebroplasty to treat vertebral hemangiomas, metastases, and osteoporotic fractures. Cement may leak out of the vertebral body and compress the adjacent spinal cord and nerve roots. We review a case of nerve-root and cord compression from methylmethacrylate extrusion during vertebroplasty. SUMMARY OF BACKGROUND DATA: A 50-year-old female presented with disabling thoracic back pain. A metastasis to T1 was discovered, with collapse of the vertebral body but without cord compression. Methylmethacrylate vertebroplasty was performed. After injection, portable computed tomography (CT) showed a leakage of methylmethacrylate into the C8 and T1 foramina and spinal canal. Radiculopathy and myelopathy developed. Surgical decompression using the anterior approach was necessary. METHODS: Case report. RESULTS: Early surgical intervention decompressed the neural elements and relieved the neurological deficits. CONCLUSIONS: Neurologic complications of methylmethacrylate vertebroplasty necessitate active involvement of spine surgeons in patient evaluation and management.

Back Pain↗

The effect of methylmethacrylate on fracture healing.

Fractures were created in the femur of dogs by dividing the midshaft with an airdriven saw. Immobilization was achieved with a four-hole compression plate. No methylmethacrylate supplementation was used in the control groups. In the three experimental groups methylmethacrylate was added to the internal fixation by placing it on the endosteal, periosteal, and both surfaces of the bone. Healing of the fractures uniformly failed to occur when methylmethacrylate was apposed to both periosteal and endosteal regions. Histologic, fluorescent, and autoradiographic studies indicated that the bone surface in contact with methylmethacrylate was necrotic and did not incorporate tetracycline or Ca-45. New bone occurred only on the surface which was not in contact with methylmethacrylate.

Animals↗

The effects of filling experimental large cortical defects with methylmethacrylate.

Three studies were performed using paired cadaver femurs to determine the effectiveness of filling large lytic defects of the femur with methylmethacrylate. In the first test, the paired femurs were prepared with a 2.5 cm defect in the femoral cortex. One of the paired femur defects was then filled with methylmethacrylate, while the other femur was left unfilled. The femurs were then tested in axial loading until failure. In the second test the paired femurs were prepared in the same manner and tested in torque until failure. In the third test, one of the paired femurs was prepared with a 2.5 cm defect and filled with methylmethacrylate while the other femur was left intact. When comparing those femurs whose defect was filled with methylmethacrylate to the prepared femurs that remained untreated, a significant increase in axial load strength of approximately 50% and an increase in torque strength of approximately 70% was found. It would seem that filling large lytic defects with methylmethacrylate at the time of internal fixation would significantly increase strength in both axial and torsional loadings.

Aged↗

Blood levels and half-life of methylmethacrylate after tourniquet release during knee arthroplasty.

The blood levels and the half-life of monomeric methylmethacrylate after tourniquet release were studied in nine patients with osteoarthrosis or rheumatoid arthritis of the knee joint, treated with the Townley prosthesis under spinal anesthesia. Several ventricular extrasystoles were monitored in one patient with high blood levels of monomeric methylmethacrylate (119.80 micrograms/ml). The blood levels of monomeric methylmethacrylate ranged between 0.10 and 1.44 microgram/ml in the rest of the patients. The half-life of monomeric methylmethacrylate in vivo was 47-55 min.

Aged↗

The use of methylmethacrylate cement as an instantaneous fusion mass in posterior cervical fusions: a canine in vivo experimental model.

The authors previously predicted the failure of posterior cervical fusions utilizing methylmethacrylate cement as an instantaneous "fusion" mass, based on research using an in vitro canine experimental model. This report describes the results of in vivo canine studies on the same subject. Three groups of dogs had application of a posterior C4-C5 20-gauge cerclage wire and autologous iliac crest bone graft; application of a posterior C4-C5 20-gauge cerclage wire and methylmethacrylate cement; or application of a C4-C5 20-gauge cerclage wire only. This group represented the control group. The dogs were allowed to live for 3 months postoperatively, at which time they were killed and their spine fusions studied radiologically, mechanically, and histologically. Five of the bone fusions united solidly radiologically. Their flexion stability was statistically superior to the others. Histologic studies confirmed solid union of the fusion mass to the underlying bone. Four of the six methylmethacrylate fusions demonstrated cerclage wire fracture and methacrylate-bone separation by the second postoperative month. At the time the dogs were killed, their flexion stability was statistically inferior to the bone fusions and tended to be inferior to the controls as well. Histologically, fibrous tissue was noted to have grown between the methacrylate "fusion" mass and the underlying bone. This work provides a mechanical explanation for the well-known success of the traditional bony fusion. It further supports our original prediction regarding the failure of methylmethacrylate "fusions."

Animals↗

The inflammatory response to secondary methylmethacrylate challenge in lens-implanted rabbits.

Polymethylmethacrylate intraocular-lens-implanted rabbits were challenged with subcutaneous polymeric or monomeric methylmethacrylate. The inflammatory response to this secondary challenge was compared to that at the site of sham procedures and to that in control rabbits never exposed to methylmethacrylate. There was a definite granulomatous inflammatory response to both polymeric and monomeric methylmethacrylate. There was, however, no secondary enhancement of this inflammatory response at the site of subcutaneous challenge or exacerbation of intraocular inflammation in lens-implanted rabbits, thus substantiating the nonimmunogenicity of methylmethacrylate.

Animals↗

Failure of stabilization of the spine with methylmethacrylate. A retrospective analysis of twenty-four cases.

Twenty-four patients who had a major complication after attempted stabilization of the spine with methylmethacrylate were referred for treatment. The initial instability that necessitated stabilization was caused by a traumatic condition in fifteen of these patients and by a metastatic tumor in nine. The average length of time before failure of fixation was 208.3 days for the patients who had a traumatic condition and 193.7 days for those who had a neoplasm. In eleven patients a progressive neural deficit developed postoperatively, and in six others the recovery of neural function was possibly hindered by the cement. A deep wound infection developed in six patients, and in five of them treatment by removal of the methylmethacrylate and metal, followed by a prolonged period of cervical traction, was required. Loosening and failure of fixation was the most common complication--it occurred in twelve of the fifteen patients who had a traumatic lesion and in eight of the nine who had a neoplasm. Salvage operations that included removal of the cement and conventional bone-grafting procedures were performed in eleven of the twelve patients who had loosening associated with a traumatic lesion and in six of the eight who had loosening and a tumor. Stability was restored in every patient. Improved long-term results can be achieved by using grafts of iliac bone and triple-wire stabilization methods (a midline wiring between the spinous processes and two iliac-crest grafts, one on each side, wired to the posterior elements) instead of methacrylate in the primary treatment of traumatic injuries. The treatment of choice for instability caused by neoplastic destruction of two or more vertebral bodies includes a construct of methylmethacrylate anteriorly. However, if cement is used, early augmentation with posterior fusion of the spine and stabilization should be considered. As a rule, combined anterior and posterior stabilization is recommended for the reconstruction of a spine that is unstable due to neoplastic destruction. In general, whenever methylmethacrylate is used for spinal stabilization, it should be augmented with grafts of iliac bone to provide long-term stability.

Adult↗

[Interaction of methylmethacrylate and acrylamide with the microsomal oxidation system of the rat liver].

A complex, exhibiting the maximal absorption at 385-388 nm and minimal at 414-420 nm, was formed after interaction between cytochrome P-450 and methylmethacrylate and acrylamide at 5 mM concentration. Acrylamide at concentrations higher than 6 mM induced the formation of modified type 11 differential spectra with maxima at 418 nm and minima at 385 nm. Methylmethacrylate and acrylamide stimulated utilization of NADPH and inhibited hydroxylation of 3,4-benzpyrene. Methylmethacrylate inhibited also N-demethylation of aminopyrine. After treatment of rats with the monomers activities of cytochromes P-450, b5 and NADPH-cytochrome c reductase were unaltered. Methylmethacrylate and acrylamide appear to interact with the microsomal oxidative system.

Acrylamides↗