PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microscopy, Acoustic”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

An iterative algorithm for scanning tomographic acoustic microscopy.

Acoustic microscopy is capable of providing high-resolution images of small objects. When such a microscope operates in the transmission mode, it produces simply a shadow-graph of all the structures encountered by the acoustic wave passing through the object. The resultant images are difficult to comprehend because of diffraction and overlapping of complex structures. Scanning tomographic acoustic microscopy (STAM) overcomes these difficulties and produces unambiguous micrographs of objects of substantial thickness and complexity. STAM uses the back-and-forth propagation algorithm to reconstruct tomograms of various layers to be imaged. When these layers are physically close to one another, ambiguities appear in the reconstructed images. Using an iterative algorithm eliminates these ambiguities and resolves layers that are only two wavelengths apart.

Algorithms↗

A new method to correlate histology with biomechanical properties in urethral tissue. An in-vitro study using light microscopy and scanning acoustic microscopy.

When surveying the classical biomechanical theory of flow and resistance, the passive elastic properties of the urethra seems to be important for the transport of urine though the urethra. The aim of this study was to show that scanning acoustic microscopy (SAM) is a suitable methodology for investigating elastic properties of the urethra, and that it can be used to correlate elastic properties to histological areas. One 40 kg female pig and one 2 kg male rabbit comprised the material. A SAM2000 was used at a working frequency of 1000 MHz. Sections of nominal 3 micrometer thickness fixed urethral tissue were prepared for SAM and stained for light microscopy. The histological layers of the urethra were evident in the SAM image, and showed highly variable values of elastic properties. The layers seen with SAM correlated well with those seen with light microscopy. In conclusion, we have provided the first images of the microelastic properties of the urethra and correlated them to histology.

Animals↗

Non-mineralized fibrocartilage shows the lowest elastic modulus in the rabbit supraspinatus tendon insertion: measurement with scanning acoustic microscopy.

The acoustic properties of rabbit supraspinatus tendon insertions were measured by scanning acoustic microscopy. After cutting parallel to the supraspinatus tendon fibers, specimens were fixed with 10% neutralized formalin, embedded in paraffin, and sectioned. Both the sound speed and the attenuation constant were measured at the insertion site. The 2-dimensional distribution of the sound speed and that of the attenuation constant were displayed with color-coded scales. The acoustic properties reflected both the histologic architecture and the collagen type. In the tendon proper and the non-mineralized fibrocartilage, the sound speed and attenuation constant gradually decreased as the predominant collagen type changed from I to II. In the mineralized fibrocartilage, they increased markedly with the mineralization of the fibrocartilaginous tissue. These results indicate that the non-mineralized fibrocartilage shows the lowest elastic modulus among 4 zones at the insertion site, which could be interpreted as an adaptation to various types of biomechanical stress.

Adaptation, Physiological↗

The acoustic properties of normal and imbedded bovine bone as measured by acoustic microscopy.

The acoustic impedance of bovine femoral cortical bone was measured with a scanning acoustic microscope used in the reflection mode. The bone was measured in the unimbedded state and after plastic imbedding. The acoustic impedance of the unimbedded specimens was also measured with a standard transmission ultrasonic technique. For the unimbedded bovine specimens there was a good correlation between the bulk transmission impedance and the reflection surface impedance (r2 = 0.976) and the values were 9.32 and 9.29 MRayls, respectively. Plastic imbedding produced a consistent and statistically significant increase in the acoustic impedance of the bone (9.71 MRayls). This experiment verified the use of acoustic microscopy as a quantitative materials analysis technique and it demonstrated the potential for material property analysis of imbedded bone.

Acoustic Impedance Tests↗

Frequency dependence of tissue attenuation measured by acoustic microscopy.

Broadband scanning acoustic microscopy (SAM) has been used to investigate the mechanical properties of sections of tissue with a resolution of around 8 microns. The work reported here extends these results by reporting the frequency dependence of the attenuation coefficient from 100-500 MHz. A discussion of the theory of the measurements is presented. The scanning laser acoustic microscope (SLAM) is used to characterize similar tissue sections at 100 MHz. The data obtained with the two forms of acoustic microscopy are compared with results from the literature.

Acoustics↗

Callus mineralization following distraction osteogenesis of the mandible monitored by scanning acoustic microscopy (SAM).

BACKGROUND: Scanning acoustic microscopy uses ultrasound to analyse histomorphology of tissues with microscopic resolution and delivers data about physical properties of the specimen. MATERIAL AND METHODS: Bony consolidation was monitored by scanning acoustic microscopy in 12 embedded specimens of dog mandibles after distraction osteogenesis. Increasing mineralization was detected by measurements of acoustic impedance (Z). RESULTS: There was a strong correlation between acoustic impedance and time of consolidation. Measurements of the speed of sound (v) provided specific information about non-mineralized zones of the distracted area. Distribution of density in the distracted area could be reconstructed by using the measurements of acoustic impedance and speed of sound. CONCLUSION: The method seems suitable for studying bone remodelling qualitatively and quantitatively.

Acoustics↗

Visualization of human umbilical vein endothelial cells by acoustic microscopy.

The morphology and acoustic properties of the human umbilical vein endothelial cells (HUVECs) were evaluated using a scanning acoustic microscope system. HUVECs were cultured for 4 days and exposed to the endotoxin for 4 h. The frequency of the scanning acoustic microscope was variable between 100 and 210 MHz. By changing the measuring frequency, ultrasonic amplitude and phase were measured and the quantitative value of attenuation was calculated. Before and after endotoxin stimuli, HUVECs were observed by scanning acoustic microscopy and the attenuation was measured. The acoustic images were successfully obtained to identify the outer shape of the HUVEC and the location of the nucleus in the cell. The attenuation of the nucleus is higher than that of the cytoplasm. The attenuation of the cytoplasm was increased and became inhomogeneous after endotoxin exposure. This finding would be related to the change of F-actin filaments, which is the main component of the cytoskeleton. Scanning acoustic microscopy is useful for assessing the cellular viscoelastic properties since it can detect both the morphological and acoustic changes without contacting the cellular surface.

Acoustics↗

Measurement of cellular elastic properties by acoustic microscopy.

The acoustic microscope is used to investigate the elastic properties of living biological cells. A quantitative model is developed relating acoustic microscope image contrast to cellular elastic properties. Cytoplasmic acoustic attenuation is measured by focusing the acoustic microscope on the surface of the underlying substrate. Cytoplasmic acoustic impedance is measured by focusing the acoustic microscope on the top surface of the cell. The model allows the acoustic microscope to give quantitative information about cellular elasticity on a subcellular scale.

Acoustics↗

Quantitative determination of contact stiffness using atomic force acoustic microscopy

Atomic force acoustic microscopy is a near-field technique which combines the ability of ultrasonics to image elastic properties with the high lateral resolution of scanning probe microscopes. We present a technique to measure the contact stiffness and the Young's modulus of sample surfaces quantitatively, with a resolution of approximately 20 nm, exploiting the contact resonance frequencies of standard cantilevers used in atomic force microscopy. The Young's modulus of nanocrystalline ferrite films has been measured as a function of oxidation temperature. Furthermore, images showing the domain structure of piezoelectric lead zirconate titanate ceramics have been taken.

Journal Article↗

Quantitative measurements of the mechanical properties of human bone tissues by scanning acoustic microscopy.

The quantitative scanning acoustic microscopy is used for determination of the acoustic impedance of human femoral bones in the micrometer scale. The method is introduced and demonstrated at prepared bone surfaces with different cutting angles referring to the bone axis. First measurements show weak variations of the elastomechanical properties with angles.

Biomechanical Phenomena↗

Combined phase-sensitive acoustic microscopy and confocal laser scanning microscopy.

Combined phase-sensitive acoustic microscopy (PSAM) at 1.2 GHz and confocal laser scanning microscopy (CLSM) in reflection and fluorescence has been implemented and applied to polymer blend films and fluorescently labeled fibroblasts and neuronal cells in order to explore the prospects and the various contrast mechanisms of this powerful technique. Topographic contrast is available for appropriate samples from CLSM in reflection and, with significantly higher precision, from the acoustic phase images. Material contrast can be gained from acoustic amplitude V(z) graphs. In the case of the biological cells investigated, the optical and acoustic images are very different and exhibit different features of the samples.

3T3 Cells↗

Determination of the elasticity coefficient for a single trabecula of a cancellous bone: scanning acoustic microscopy approach.

Scanning acoustic microscope techniques enable determination of mechanical properties of small samples. These techniques can be applied to a single trabecula of the cancellous bone. This paper describes nondestructive methods for assessing the bone tissue elasticity for samples accessible from one side only. Two methods are applied in the same area of a trabecula. The first one allows determination of the tissue impedance, based on the correlation between the grey levels of the scanning acoustic microscope images and of the reference material of a known impedance. The second newly-developed technique enables measurement of the velocity of surface waves with a spatial resolution less than 100 mum, using theoretical and experimental analysis of the position of the first interference of the V(z) curve. These two experimentally-derived parameters were used to calculate the density and elasticity coefficient for trabecular bone samples of patients who suffered from metabolic bone diseases, such as osteoporosis, osteomalacia and osteoidosis. Medical descriptions of these diseases explain the differences in mechanical properties of trabecular bone tissue found experimentally.

Bone Diseases, Metabolic↗

Investigation of elasto-mechanical properties of alginate microcapsules by scanning acoustic microscopy.

High-frequency scanning acoustic microscopy (SAM) was used for investigation of acoustic impedance and 3D-surface topography of full alginate microspheres that act as model of artificial biological cells. Elasto-mechanical properties of the investigated specimens have been characterized by acoustic impedance. Mean surface impedance of microspheres (diameter: 300 microm) was measured with SAM at 900 MHz with a spatial resolution of 1.5 microm. The sensitivity and reproducibility of SAM had to be increased considerable to receive and quantify signals in the very low impedance region. The multilayer analysis method was used to get quantitative data of acoustic impedance with SAM at a microscopic level. 3D images show details of structure and surface topography. As a reference, bulk measurements were performed on full alginate cylinders. The acoustical impedance and the mechanical stiffness c(11) were obtained from mass density and longitudinal ultrasound velocity at 6 MHz. The impedances received with both methods are in close agreement. The results demonstrate the SAM as a powerful tool for characterizing mechano-elastical parameters as well as surface structure and topography of microspheres with high spatial resolution.

Acoustics↗

Acoustic microscopy system: design and preliminary results.

An acoustic microscopy system was designed to perform 2D imaging in the C-plane with a single-element transducer. The ultrasound transducer was fabricated by polishing bulk lithium niobate (LiNbO(3)) to the required thickness (approximately 60 or 45 micro) for the desired operating frequency (55 or 75 MHz). The polished LiNbO(3) was attached to acoustic backing and matching layers. Finally, an epoxy lens was applied and the transducer mounted in a housing. The transducer was mounted in a 3D motorized positioning stage and operated by a high-frequency pulser/receiver. Received echoes were sampled with a 2 GHz ADC card and displayed on a PC using software developed in the Matlab environment. Transducer frequency and bandwidth were measured off a steel plate positioned at the focal length. A penny was scanned initially to confirm expected performance before acquiring data from liver (n=3) and spleen (n=3) specimens. For the first probe, the peak frequency was 54.05 MHz with a -6 dB bandwidth of 6.76 MHz. The axial and lateral resolutions were estimated to be 114 and 188 microm, respectively. For the second probe, the peak frequency was measured to 82 MHz with a -6 dB bandwidth of approximately 23 MHz. The axial and lateral resolutions were estimated to be around 33 and 81 microm, respectively. C-scans of the penny clearly showed detailed structures on front and back, while the capsule and the trabecular structures of the splenic tissues could easily be separated in different layers. In conclusion, an acoustic microscopy system operating at 55-75 MHz has been constructed and the feasibility of obtaining high-resolution images of tissue specimens demonstrated.

Acoustics↗

Visualization of myocardial cellular architecture using acoustic microscopy.

The resolution of an ultrasound transducer depends on its frequency. The resolution improves when higher frequency transducers are used. A 1000 MHz transducer has a resolution of approximately 1 micron. Acoustic microscopy utilizes very high-frequency ultrasound (600 to 1000 MHz) to visualize structures on a microscopic level. Unstained, deparaffinized, 5 microns sections of myocardial biopsy specimens from 10 patients were placed on a slide and imaged using an Olympus UH3 scanning acoustic microscope. To compare with light microscopy, the section used for acoustic microscopy was subsequently stained with hematoxylin and eosin and a serial section from the paraffin block was stained with PTAH stain. Myocytes, myofibrils, and interstitial tissue were accurately imaged. Pathologic phenomena such as cell fallout, interstitial fibrosis, and lymphocytic infiltration were identified by acoustic microscopy. Intramural vessels, nuclei of endothelial cells, and the media were clearly identified by this technique. There was close correlation between findings by acoustic microscopy and light microscopy. Acoustic microscopy permitted the visualization of cardiac cellular detail with a resolution similar to that of light microscopy. Unlike light microscopy, acoustic microscopy requires no staining of the specimen.

Biopsy↗

Quantitative Short-pulse Acoustic Microscopy and Application to Materials Characterization.

A new acoustic microscopy method was developed for providing near-surface elastic property mapping of a material. This method has a number of advantages over the traditional V(z) technique. First, it enables one to perform measurements in an automated mode that only requires user intervention in the setup phase. This automated mode makes it feasible to obtain quantitative microscopy images of the elastic property over an area on the material being tested. Also, it only requires a conventional ultrasonic system operating in pulsed mode for collecting the data, rather than a specialized tone-burst system, which is needed in the traditional quantitative scanning acoustic microscopy technique. Finally, unlike the traditional method, the new experimental process does not require calibration of the system's electronics or additional reference data taken under hard-to-duplicate identical conditions from a material that does not exhibit surface acoustic waves.

Journal Article↗

Time-resolved line focus acoustic microscopy of layered anisotropic media: application to composites.

This paper presents theoretical and experimental studies of the time-domain response of line focus acoustic microscopy from a layered anisotropic medium. A method for elastic constant reconstruction from acoustic microscopy signatures also is presented. The microscopy response is complicated by multiple reflections in the layers and by the anisotropic nature of the material. The model is based on a new, stable recursive stiffness matrix algorithm developed for a multilayered anisotropic medium, which is applied to the interpretation of the time-resolved acoustic microscopy signature. Specific examples are given for unidirectional and multidirectional graphite epoxy composites. It is shown that the fluid load has a significant effect on the leaky surface waves in these composites, increasing surface wave speed above that for the slow transverse wave. This results in its absence from the microscopy signature of the surface wave. The theoretical results are compared with experiments carried out using a line focus PVDF transducer developed at National Institute of Standards and Technology (NIST). Time-resolved acoustic microscopy has been applied to the determination of elastic constants of a unidirectional composite or of one lamina in a cross-ply composite. The lateral waves and multiple reflections of bulk waves appearing in the microscopy signatures are used for the elastic properties reconstruction. The reconstruction results are compared to data obtained by the self-reference double-through-transmission ultrasonic bulk wave method.

Journal Article↗

Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation muCT.

200 MHz scanning acoustic microscopy (SAM) and synchrotron radiation muCT (SR-muCT) were used to assess microstructural parameters and tissue properties in site-matched regions of interest in cortical bone. Anterior and postero-lateral regions of ten cross sections from human cortical radius were explored. Structural parameters, including diameter and number of Haversian canals per cortical area (Ca.Dm, N.Ca/Ar) and porosity Po were assessed with both methods using a custom-developed image fusion and analysis software. Acoustic impedance Z and degree of mineralization of bone DMB were extracted separately for osteonal and interstitial tissues from the fused images. Structural parameter estimations obtained from radiographic and acoustic images were almost identical. DMB and impedance values were in the range between 0.77 and 1.28 g cm(-3) and 5.13 and 12.1 Mrayl, respectively. Interindividual and regional variations were observed, whereas the strongest difference was found between osteonal and interstitial tissues (Z: 7.2 +/- 1.1 Mrayl versus 9.3 +/- 1.0 Mrayl, DMB: 1.06 +/- 0.07 g cm(-3) versus 1.16 +/- 0.05 g cm(-3), paired t-test, p < 0.05). Weak, but significant correlations between DMB and Z were obtained for the osteonal (R(2) = 0.174, p < 10(-4)) and for the pooled (osteonal and interstitial) data. The regression of the pooled osteonal and interstitial tissue data follows a second-order polynomial (R(2) = 0.39, p < 10(-4)). Both modalities fulfil the requirement for a simultaneous evaluation of cortical bone microstructure and material properties at the tissue level. While SAM inspection is limited to the evaluation of carefully prepared sample surfaces, SR-muCT provides volumetric information on the tissue without substantial preparation requirements. However, SAM provides a quantitative estimate of elastic properties at the tissue level that cannot be captured by SR-muCT.

Aged↗