PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “NASA Discipline Environmental Health”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Incorporating biologically based models into assessments of risk from chemical contaminants.

The general approach to assessment of risk from chemical contaminants in drinking water involves three steps: hazard identification, exposure assessment, and dose-response assessment. Traditionally, the risks to humans associated with different levels of a chemical have been derived from the toxic responses observed in animals. It is becoming increasingly clear, however, that further information is needed if risks to humans are to be assessed accurately. Biologically based models help clarify the dose-response relationship and reduce uncertainty.

Animals↗

Alveolar ventilation to perfusion heterogeneity and diffusion impairment in a mathematical model of gas exchange.

This study describes a two-compartment model of pulmonary gas exchange in which alveolar ventilation to perfusion (VA/Q) heterogeneity and impairment of pulmonary diffusing capacity (D) are simultaneously taken into account. The mathematical model uses as input data measurements usually obtained in the lung function laboratory. It consists of two compartments and an anatomical shunt. Each compartment receives fractions of alveolar ventilation and blood flow. Mass balance equations and integration of Fick's law of diffusion are used to compute alveolar and blood O2 and CO2 values compatible with input O2 uptake and CO2 elimination. Two applications are presented. The first is a method to partition O2 and CO2 alveolar-arterial gradients into VA/Q and D components. The technique is evaluated in data of patients with chronic obstructive pulmonary disease (COPD). The second is a theoretical analysis of the effects of blood flow variation in alveolar and blood O2 partial pressures. The results show the importance of simultaneous consideration of D to estimate VA/Q heterogeneity in patients with diffusion impairment. This factor plays an increasing role in gas alveolar-arterial gradients as severity of COPD increases. Association of VA/Q heterogeneity and D may produce an increase of O2 arterial pressure with decreasing QT which would not be observed if only D were considered. We conclude that the presented computer model is a useful tool for description and interpretation of data from COPD patients and for performing theoretical analysis of variables involved in the gas exchange process.

Blood Gas Monitoring, Transcutaneous↗

Toxicokinetics of inhaled bromotrifluoromethane (Halon 1301) in human subjects.

Bromotrifluoromethane (CBrF3), commonly known as Halon 1301, is used as a fire extinguishant in the Space Shuttle. Several scenarios, such as a fire or a faulty alarm, could lead to its discharge resulting in a Halon 1301 concentration of up to 1% in the spacecraft cabin atmosphere. To examine the effects of Halon 1301 on mental performance and physiologic function, the National Aeronautics and Space Administration sponsored a human inhalation study. Four pairs of adult male subjects were each exposed in a double-blind fashion for 24 hr to 1% (10,000 ppm or 60,875 mg/m3) Halon 1301 and to air in two separate exposures approximately 1 week apart. Mental performance and physiologic function were assessed and the results are reported in a companion paper (D. S. Calkins, J. J. Degioanni, M. N. Tan, J. R. Davis, and D. L. Pierson. Fundam. Appl. Toxicol. 20, in press). Blood and breath samples from the exposed subjects were also collected to provide dosimetric and toxicokinetic information, which is presented here. Blood Halon 1301 levels increased rapidly and approached a steady state within 2 hr of beginning the exposure; the steady-state concentration was approximately 3-4.5 micrograms/ml. Breath samples collected during exposures closely reflected chamber concentrations. Analysis of postexposure blood samples revealed that Halon 1301 was eliminated biphasically with an average t1/2 alpha and t1/2 beta of 4.5 min (range 2.5-8.1 min) and 200 min (range 131-347 min), respectively. Halon 1301 concentrations in fat and soft tissues were also estimated. Subsequently, the end-tidal breath/blood/tissue/fat partition coefficients were calculated to be 17/1/0.5/33.(ABSTRACT TRUNCATED AT 250 WORDS)

Adipose Tissue↗

Human performance and physiological function during a 24-hr exposure to 1% bromotrifluoromethane (Halon 1301).

Performance and physiological measurements were obtained from four pairs of men exposed for 24 hr to 1% (10,000 ppm) Halon 1301 (bromotrifluoromethane, CBrF3) and to air with order counterbalanced using a double-blind protocol. Cognitive and motor performance was assessed before, during, and after the exposures using seven scales of the Automated Portable Testing System, which produced 13 measures of performance. Halon inhalation induced decrements in 2 of the 13 measures, but actual and estimated magnitudes of the decrements were no greater than 5% of baseline values. Physiological data were obtained before, during, and after the exposures from clinical chemistry analyses of blood and urine samples, pulmonary function tests, and monitoring of vital signs. Significant change during Halon inhalation was observed for 6 of the 52 variables assessed; however, all physiological values remained within clinically acceptable limits. No cardiovascular effects were noted. This study demonstrated that exposure to 1% Halon 1301 for 24 hr can produce minor disturbance of central nervous system function as assessed by cognitive tasks.

Administration, Inhalation↗

Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome.

Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

Air Conditioning↗

Colonization by Cladosporium spp. of painted metal surfaces associated with heating and air conditioning systems.

Cladosporium cladosporioides and C. hebarum colonized painted metal surfaces of covering panels and register vents of heating, air conditioning and ventilation systems. Hyphae penetrated the paint film and developed characteristic conidiophores and conidia. The colonies were tightly appressed to the metal surface and conidia were not readily detectable via standard air sampling procedures.

Air Conditioning↗

Gramicidin S production by Bacillus brevis in simulated microgravity.

In a continuing study of microbial secondary metabolism in simulated microgravity, we have examined gramicidin S (GS) production by Bacillus brevis strain Nagano in NASA High Aspect Rotating Vessels (HARVs), which are designed to simulate some aspects of microgravity. Growth and GS production were found to occur under simulated microgravity. When performance under simulated microgravity was compared with that under normal gravity conditions in the bioreactors, GS production was found to be unaffected by simulated microgravity. The repressive effect of glycerol in flask fermentations was not observed in the HARV. Thus the negative effect of glycerol on specific GS formation is dependent on shear and/or vessel geometry, not gravity.

Anti-Bacterial Agents↗

Secondary metabolism in simulated microgravity: beta-lactam production by Streptomyces clavuligerus.

Rotating bioreactors designed at NASA's Johnson Space Center were used to simulate a microgravity environment in which to study secondary metabolism. The system examined was beta-lactam antibiotic production by Streptomyces clavuligerus. Both growth and beta-lactam production occurred in simulated microgravity. Stimulatory effects of phosphate and L-lysine, previously detected in normal gravity, also occurred in simulated microgravity. The degree of beta-lactam antibiotic production was markedly inhibited by simulated microgravity.

Anti-Bacterial Agents↗

Evaluation of the Biolog MicroStation system for yeast identification.

One hundred and fifty-nine isolates representing 16 genera and 53 species of yeasts were processed with the Biolog MicroStation System for yeast identification. Thirteen genera and 38 species were included in the Biolog database. For these 129 isolates, correct identifications to the species level were 13.2, 39.5 and 48.8% after 24, 48 and 72 hours incubation at 30 degrees C, respectively. Three genera and 15 species which were not included in the Biolog database were also tested. Of the 30 isolates studied, 16.7, 53.3 and 56.7% of the isolates were given incorrect names from the system's database after 24,48 and 72 h incubation at 30 degrees C, respectively. The remaining isolates of this group were not identified.

Candida↗

Iodine susceptibility of pseudomonads grown attached to stainless steel surfaces.

Pseudomonads were adapted to grow in phosphate-buffered water and on stainless steel surfaces to study the iodine sensitivity of attached and planktonic cells. Cultures adapted to low nutrient growth were incubated at room temperature in a circulating reactor system with stainless steel coupons to allow biofilm formation on the metal surfaces. In some experiments, the reactor was partially emptied and refilled with buffer at each sampling time to simulate a "fill-and-draw" water system. Biofilms of attached bacteria, resuspended biofilm bacteria, and reactor suspension, were exposed to 1 mg l-1 iodine for 2 min. Attached bacterial populations which established on coupons within 3 to 5 days displayed a significant increase in resistance to iodine. Increased resistance was also observed for resuspended cells from the biofilm and planktonic bacteria in the system suspension. Generally, intact biofilms and resuspended biofilm cells were most resistant, followed by planktonic bacteria and phosphate buffer cultures. Thus, biofilm formation on stainless steel surfaces within water systems can result in significantly increased disinfection resistance of commonly-occurring water-borne bacteria that may enhance their ability to colonise water treatment and distribution systems.

Biofilms↗

Effect of body repositioning after venous air embolism. An echocardiographic study.

BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.

Animals↗

Effects of substrates and phosphate on INT (2-(4-iodophenyl)-3-(4-nitrophenyl)-5-phenyl tetrazolium chloride) and CTC (5-cyano-2,3-ditolyl tetrazolium chloride) reduction in Escherichia coli.

The effects of substrates of primary aerobic dehydrogenases, and inorganic phosphate on aerobic INT and CTC reduction in Escherichia coli were examined. In general, INT produced less formazan than CTC, but INT (+) cell counts remained near values of CTC (+) cells. INT and CTC (+) cell numbers were higher than plate counts on R2A medium using succinate, formate, lactate, casamino acids, glucose, glycerol (INT only) and no substrate. Formate resulted in the greatest amount of INT and CTC formazan. Reduction of both INT and CTC was inhibited above 10 mmol l-1 phosphate, and this appeared to be related to decreased rates of O2 consumption. Formation of fluorescent CTC (+), but not INT (+) cells was also inhibited in a concentration dependent manner by phosphate above 10 mmol l-1. From light microscopic observations it appeared CTC formed increasing amounts of poorly or non-fluorescent formazan with increasing phosphate. Therefore, use of phosphate buffer in excess of 10 mmol l-1 may not be appropriate in CTC and INT reduction assays.

Colony Count, Microbial↗

Epidemiology of Staphylococcus aureus during space flight.

Staphylococcus aureus was isolated over 2 years from Space Shuttle mission crewmembers to determine dissemination and retention of bacteria. Samples before and after each mission were from nasal, throat, urine, and feces and from air and surface sampling of the Space Shuttle. DNA fingerprinting of samples by digestion of DNA with SmaI restriction endonuclease followed by pulsed-field gel electrophoresis showed S. aureus from each crewmember had a unique fingerprint and usually only one strain was carried by an individual. There was only one instance of transfer between crewmembers. Strains from interior surfaces after flight matched those of crewmembers, suggesting microbial fingerprinting may have forensic application.

DNA Fingerprinting↗

Evaluation of the Biolog automated microbial identification system.

Biolog's identification system was used to identify 39 American Type Culture Collection reference taxa and 45 gram-negative isolates from water samples. Of the reference strains, 98% were identified to genus level and 76% to species level within 4 to 24 h. Identification of some authentic strains of Enterobacter, Klebsiella, and Serratia was unreliable. A total of 93% of the water isolates were identified.

Bacterial Typing Techniques↗

Acute mountain sickness: increased severity during simulated altitude compared with normobaric hypoxia.

Acute mountain sickness (AMS) strikes those in the mountains who go too high too fast. Although AMS has been long assumed to be due solely to the hypoxia of high altitude, recent evidence suggests that hypobaria may also make a significant contribution to the pathophysiology of AMS. We studied nine healthy men exposed to simulated altitude, normobaric hypoxia, and normoxic hypobaria in an environmental chamber for 9 h on separate occasions. To simulate altitude, the barometric pressure was lowered to 432 +/- 2 (SE) mmHg (simulated terrestrial altitude 4,564 m). Normobaric hypoxia resulted from adding nitrogen to the chamber (maintained near normobaric conditions) to match the inspired PO2 of the altitude exposure. By lowering the barometric pressure and adding oxygen, we achieved normoxic hypobaria with the same inspired PO2 as in our laboratory at normal pressure. AMS symptom scores (average scores from 6 and 9 h of exposure) were higher during simulated altitude (3.7 +/- 0.8) compared with either normobaric hypoxia (2.0 +/- 0.8; P < 0.01) or normoxic hypobaria (0.4 +/- 0.2; P < 0.01). In conclusion, simulated altitude induces AMS to a greater extent than does either normobaric hypoxia or normoxic hypobaria, although normobaric hypoxia induced some AMS.

Acute Disease↗

Cardiovascular pressures with venous gas embolism and decompression.

Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts, and deepsea divers who have decompression-induced venous bubbles do not demonstrate neurological symptoms at these high rates. This apparent disparity may be attributable to the normal pressure gradient across the atria of the heart that must be reversed for there to be flow patency. We evaluated the effects of: a) venous gas embolism (0.025, 0.05 and 0.15 ml.kg-1.min-1 for 180 min.); b) hyperbaric decompression; and c) hypobaric decompression on the pressure gradient across the left and right atria in anesthetized dogs with intact atrial septa. Left ventricular end-diastolic pressure was used as a measure of left atrial pressure. In a total of 92 experimental evaluations in 22 dogs, there were no reported reversals in the mean pressure gradient across the atria; a total of 3 transient reversals occurred during the peak pressure gradient changes. The reasons that decompression-induced venous bubbles do not consistently cause serious symptoms of decompression illness may be that the amount of venous gas does not always cause sufficient pressure reversal across a patent foramen ovale to cause arterialization of the venous bubbles.

Altitude↗