PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Nonoxynol-9--administraction and dosage”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

5 recordsLinked to original sources

An evaluation of the amount of nonoxynol-9 remaining in the vagina up to 4 h after insertion of a vaginal contraceptive film (VCF) containing 70 mg nonoxynol-9.

The objectives of this study were to determine the amount of nonoxynol-9 (N-9) remaining in the vagina 30 min and 1, 1.5, 2, and 4 h after vaginal insertion of a single sheet of VCF containing 70 mg N-9 and to compare these results to the manufacturer's instructions for use of this product. A new method of vaginal lavage was used to obtain samples for N-9 determination. This was an open-label, noncomparative, pharmacokinetic study in 12 healthy women volunteers not at risk for pregnancy. The study consisted of a screening visit followed by five test visits approximately 1 month apart and a final visit 1 week after all test visits were completed. At each test visit, the investigator inserted a single sheet of VCF in the vagina of the volunteer at midcycle. The volunteer remained in the clinic and underwent vaginal lavage with normal saline after one of five specified time intervals had elapsed. The sequence of the intervals completed by each volunteer was determined by randomization. When undissolved film was found in the vagina, it was removed prior to lavage and assayed for N-9 content separately from that recovered in lavage fluid. It was assumed that the N-9 in undissolved film would not contribute significantly to sperm immobilization. Between 18.5 and 28.5 mg of N-9 were recovered in lavage fluid after intervals of 0.5, 1, 1.5, and 2 h. These levels did not differ statistically (p > 0.05). The amount of N-9 recovered dropped significantly at 4 h to 11.0 mg. If it is assumed that an N-9 concentration of 0.100 mg/mL is required to immobilize sperm in vitro, this study suggests that the amount of N-9 remaining in the vagina in the form of dissolved film up to 4 h after insertion of VCF is sufficient to immobilize sperm. The lavage procedure may not have recovered all N-9 remaining in the vagina. However, intercourse did not take place between insertion and lavage; if it had, the proportion of the film remaining undissolved and the total amount N-9 remaining in the vagina at the time of examination might have been affected.

Administration, Intravaginal↗

Comparative spermicidal performance of iodinated and non-iodinated contraceptive formulations of nonoxynol-9 co-precipitated with polyvinylpyrrolidone.

The objective of this study was to evaluate the spermicidal qualities of various combinations of nonoxynol-9 (N-9; whole molecule = oligomers 1-18) and its isolated fractions (oligomers 8-10, 4-6 and 1-3), co-precipitated with non-iodinated and/or iodinated (Io) polyvinylpyrrolidone (PVP) as possible vaginal contraceptives. Spermicidal qualities of known equimolar concentrations of various combinations of PVP/N-9 and PVP-Io/N-9 were tested via a modified Sander-Cramer test (SCT) using human spermatozoa. Spermicidal agents and semen samples were mixed 1:1 (v/v) and evaluated for sperm viability. Spermicidal activity was reported as the minimal concentration (microgram/mL) of spermicide capable of killing all spermatozoa within 20 sec after exposure to the spermicide. The spermicidal activity of PVP/N-9 and PVP-Io/N-9 preparations containing N-9 oligomers 1-18 and/or 8-10 was similar, and these preparations were more efficient in killing the spermatozoa than the ones containing N-9 oligomers 4-6 and 1-3. Polyvinyl-pyrrolidone proved to be an effective vehicle for PVP/N-9 and PVP-Io/N-9 preparations, especially those containing N-9 oligomers 4-6 and 1-3. Incorporation of Io into the spermicidal preparations brought about additional efficacy. The current findings could be of clinical significance in future studies when preparing and delivering those selected co-precipitates vaginally.

Cell Survival↗

A phase I comparative study of contraceptive vaginal films containing benzalkonium chloride and nonoxynol-9. Postcoital testing and colposcopy.

Benzalkonium chloride (BZK) has been shown in in vitro and in vivo studies to immobilize sperm, to be active against STD-causing organisms, and to penetrate and thicken cervical mucus. A US clinical study of a sponge containing 60 mg BZK showed life table pregnancy rates at 6 and 12 months of 11.7 and 18.9 per 100 women, respectively. BZK is not currently marketed in the US as a contraceptive. The present study aimed to assess 1) the ability of a new contraceptive vaginal film containing either of two doses of BZK to prevent the penetration of sperm into midcycle cervical mucus; 2) the effect of the film on the vaginal epithelium; and 3) the acceptability of the film. All results were compared with VCF, a currently marketed film containing nonoxynol-9 (N-9). Ten women underwent two baseline cycles of postcoital testing in which no film was used, followed by three test cycles in which Allendale-BZK film, a new film containing either 19 or 25 mg BZK, or VCF, containing 70 mg N-9, was used. The sequence of testing cycles was randomized. In each cycle, condoms were used prior to midcycle, then a midcycle cervical mucus specimen was examined to ensure midcycle characteristics and the absence of sperm. Each woman then had intercourse using either no film (baseline cycles) or a test film (test cycles) and returned 2-3 h afterwards. Cervical mucus was again assessed for adequacy and the presence of sperm. Each woman also underwent colposcopy, using a protocol developed by the World Health Organization. The average number of progressively motile sperm seen per high power field was as follows: first baseline cycle, 22.2; second baseline cycle, 22.1; test cycle with film containing 19 mg BZK, 0.2; test cycle with film containing 25 mg BZK, 0.0; and test cycle with VCF containing 70 mg N-9, 0.0. There was no significant difference between baseline cycles or among test cycles in the average number of progressively motile sperm seen (p = 0.78 and p > or = 0.75, respectively). The average number of progressively motile sperm seen in each test cycle did, however, differ significantly from the average number seen in either baseline cycle (p < 0.01). Colposcopy showed superficial de-epithelialization without underlying inflammation in 15-20% of baseline cycles, regardless of whether colposcopy was done before or after coitus; in 50% of cycles in which either dose of BZK was used; and in 69% of cycles in which VCF was used. In all cases women were asymptomatic. Erythema and petechiae were also seen on colposcopy although at a lower frequency than de-epithelialization. There was no difference in the acceptability of the films. A vaginal contraceptive containing either 19 or 25 mg BZK in a new film base appears to be comparable with VCF in preventing sperm from entering midcycle cervical mucus and may be somewhat less disruptive to the vaginal epithelium.

Administration, Intravaginal↗

A phase I comparative study of three contraceptive vaginal films containing nonoxynol-9. Postcoital testing and colposcopy.

The objectives of this study were 1) to assess the ability of a new contraceptive vaginal film containing two doses of nonoxynol-9 (N-9) to prevent the penetration of sperm into midcycle cervical mucus, and 2) to determine the effect of the film on the vaginal epithelium. The novel formulation was compared with VCF (a currently marketed film also containing N-9). Ten women underwent two baseline cycles of postcoital testing in which no film was used, followed by three test cycles in which Allendale-N9 film, a new film containing either 100 or 130 mg N-9, or VCF containing 70mg N-9 was used. The sequence of testing cycles was randomized. In each cycle, condoms were used prior to midcycle, then a midcycle cervical mucus specimen was examined to ensure midcycle characteristics and the absence of sperm. Each woman then had intercourse using either no film (baseline cycles) or a test film (test cycles) and returned 2-3 h afterwards. Cervical mucus was again assessed for adequacy and the presence of sperm. Each woman also underwent colposcopy using a protocol developed by the World Health Organization. The average number of progressively motile sperm seen per high power field were as follows: average of the two baseline cycles, 19.3; test cycle with Allendale-N9 film containing 100 mg N-9, 0.6; test cycle with Allendale-N9 film containing 130 mg N-9, 0.9; and test cycle with VCF, 0.5. There was no significant difference between baseline cycles or between test cycles in the number of progressively motile sperm per high power field (HPF) seen (p = 0.31 and p > or = 0.50, respectively). The average number of motile sperm seen in each test cycle did, however, differ significantly from the number in either baseline cycle (p < 0.02). The majority of colposcopic examinations were normal. In one baseline cycle and eight test cycles, colposcopy showed superficial de-epithelialization without underlying inflammation. There was no apparent dose response and in all cases the volunteers were asymptomatic. A vaginal contraceptive containing either 100 or 130 mg N-9 in a new film base appears to be safe and comparable to VCF in preventing sperm from entering midcycle cervical mucus.

Administration, Intravaginal↗

Spermicide permeation through biocompatible polymers.

Although spermicides are safe and effective contraceptive/prophylactic agents, they are inconvenient to use. Formulations that provide a controlled release of spermicide may improve user acceptance, and therefore effectiveness. Using a two-chamber diffusion cell, we measured the rates of permeation of nonoxynol-9 (N9), benzalkonium chloride (BC), and chlorhexidine (CH) through films of ethylene-vinyl acetate copolymer (EVAc) and silicone elastomer (SILASTIC). In addition, we encapsulated N9, BC, and CH into solid polymer matrices and measured the rate of spermicide release following immersion in water. We also developed equations for predicting the release rate of spermicide from a vaginal ring containing encapsulated spermicide, and tested these equations using hollow SILASTIC rings containing pure N9 or BC. N9 diffuses through a thin film of SILASTIC several orders of magnitude slower than through water. The rates of permeation of N9 through EVAc, BC through SILASTIC, and CH through SILASTIC were too low to detect over a one-week experiment. Polymer matrices of EVAc or SILASTIC released N9 at a controlled rate for several days. Based on these measurements, we predict that a vaginal ring containing an inner core of EVAc/N9 surrounded by a thin, permeable layer of SILASTIC will provide a controlled, constant release of N9 for over 30 days. Because of its low permeability in SILASTIC, BC is probably not a good spermicide for a long-acting vaginal ring. Because of its low solubility in water, CH is also not a good candidate for controlled release into the vaginal mucus.

Benzalkonium Compounds↗