PubMed HealthSearch

SEARCH · PubMed Health

Results for “Optical Fibers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

PRDX1 as a novel urinary biomarker for bladder cancer: Development of an integrated fiber optic sensing platform.

In this study, integrated proteomic and transcriptomic analyses identified peroxiredoxin 1 (PRDX1) as a novel urinary biomarker for bladder cancer (BC). PRDX1 was significantly upregulated in BC tissues and was associated with poorer overall survival. In vitro experiments further demonstrated that PRDX1 promotes malignant phenotypes of BC cells, including proliferation, migration, and invasion. Silencing PRDX1 in BC cells significantly reduced the invasiveness and proliferation ability.To address the clinical need for rapid and non-invasive detection, we developed an innovative optical fiber biosensor based on surface plasmon resonance (SPR) technology for the quantitative detection of urinary PRDX1. The biosensor exhibited excellent analytical performance, including high sensitivity (limit of detection: 0.06 ng/mL), a wide linear range (0-25 ng/mL), rapid response (∼14 s), as well as good stability and selectivity. In clinical validation involving 97 BC patients and 30 healthy controls, the biosensor demonstrated outstanding diagnostic performance, with an area under the receiver operating characteristic curve (AUC) of 0.91 and an overall diagnostic accuracy of 86.6%, outperforming conventional enzyme-linked immunosorbent assay (ELISA). Collectively, this study not only identifies PRDX1 as a promising biomarker for non-invasive diagnosis and prognostic evaluation of BC, but also establishes an efficient SPR-based optical fiber sensing platform, providing new insights into both clinical detection and the functional role of PRDX1 in BC progression.

Humans

Oxygen optrode for use in a fiber-optic glucose biosensor.

An optical fiber oxygen sensor, based on the dynamic quenching of the luminescence of tris(1,10-phenanthroline)-ruthenium(II) cation by molecular oxygen, is presented. The complex is adsorbed onto silica gel, incorporated in a silicone matrix possessing a high oxygen permeability, and placed at the tip of the optical fiber. Oxygen has been monitored continuously in the 0-750 Torr range, with the detection limit being as low as 0.7 Torr. The device has been applied to the development of a fast responding and highly sensitive fiber-optic glucose biosensor based on this highly sensitive oxygen transducer. The sensor relates oxygen consumption (as a result of enzymatic oxidation) to glucose concentration. The enzyme is immobilized on the surface of the oxygen optrode; carbon black is used as an optical isolation in order to prevent ambient light and sample fluorescence to interfere. Measurements have been performed in a flow-through cell in air-equilibrated glucose standard solutions of pH 7.0. The effects of enzyme immobilization procedures (including enzyme immobilization on carbon black) as to response times (around 6 min), analytical ranges (0.06-1 mM glucose), reproducibility in sensor construction, and long-term stability have been studied as well.

Biosensing Techniques

A low-cost fiber-optic strain gage system for biological applications.

A new low-cost strain measurement system has been developed for the mechanical testing of biological soft tissues. The technique creates four spots of light on a tissue sample surface by piercing the tissue sample with two pairs of small light-conducting optical fibers (one pair for each axis of a biaxial stretch), terminated by high intensity infrared emitters. A large-area photodiode, located below the tissue sample, detects the light emitted from the two pairs of light-spots. Analog and digital circuitry analyze the current signal from the photodiode to determine the position of a light-spot in real time. Each infrared emitter is sequentially cycled "on" at a rate of 3 kHz and the resulting photodiode current signal, after being converted to a voltage signal, is held by an integrated circuit sample and hold amplifier. Analog differencing of pairs of light-spot voltage signals provides a final output proportional to the separation between coaxial light-spots.

Biomechanical Phenomena

Excitation and detection of action potential-induced fluorescence changes through a single monomode optical fiber.

An optical probe capable of detecting intracellular potential changes in individual cells, in vitro, which has the potential for in vivo applications, has been developed. A single-mode optical fiber directs laser light onto cells stained with the voltage-sensitive fluorescent dye, WW781 and also returns part of the resulting fluorescence to a detection system. Frog cardiac cells in vitro were used in these initial experiments. The fractional change in fluorescent intensity of 10(-3) for a 50 mV shift in transmembrane potential obtained from a heart immobilized in zero calcium Ringer's solution is comparable to that reported for other optical methods. For hearts in normal calcium Ringer's solutions, very large reproducible motion related artifacts were detected.

Animals

Normal and regenerating optic fibers in goldfish tectum: HRP-EM evidence for rapid synaptogenesis and optic fiber-fiber affinity.

The distribution of normal and regenerating retinal fibers and synapses was studied on tectum in goldfish by light (LM) and electron microscopy (EM). Since labeling of the early regenerating fibers was previously reported to be difficult, a new 'cold-fill' HRP labeling protocol was developed, which labeled regenerating optic fibers and terminals on tectum as early as 14 days after nerve crush when they first arrive on tectum. In order to characterize the laminar distribution of optic afferents in normal fish and in fish regenerating for 14-240 days, EM photomontages of areas 14 microns wide by 160 microns deep through the HRP-labeled primary optic innervation layer (S-SO-SFGS) were constructed. The time points in regeneration that were examined spanned the period in which others have shown that an initially diffuse retinotopic map becomes spatially restricted. At the LM level regenerating optic fibers were restricted to the optic lamina. They reinnervated tectum in an anterior to posterior sequence as previously seen with autoradiography. In addition, at 14 days, some "pioneer" optic fascicles were found to have already grown to posterior tectum where they gave rise to branches with boutonlike terminations and growth-cone-like processes. Form the ultrastructural analysis it was clear that optic fibers and terminals observed strict laminar boundaries as they partitioned themselves in the optic laminae (S, SO and SFGS) in both normal and regenerating fish. The behavior of optic fibers was lamina specific with respect to synapse formation and the orientation of fiber outgrowth. As early as 14 days regeneration, optic fibers made synapses onto the four types of postsynaptic profiles observed in normal fish. Numerous optic terminals were labeled at 14 days, and there appeared to be no waiting period between fiber ingrowth to the SO and synapse formation in the S and SFGS. At 14-60 days, atypical synaptic contacts which appear to be nascent synapses were made by labeled optic fibers in fascicles and by growth-cone-like processes. By 21-30 days, the density of optic terminals was high and there were many more fasciculated optic fibers in the SFGS than normal as late as 350 days. These findings suggest that optic fiber lamination is highly constrained by tectal cues, that fibers rapidly regenerate many synaptic terminals before retinotopic map refinement is complete, and that fibers have a strong affinity for each other.

Animals

Cell death and optic fiber penetration in the optic stalk of the chick.

The role of dying cells in the optic stalk in relation to retinal fiber migration was investigated in the chick embryo. Cell death was analysed at various stages of development by counting pycnotic nuclei and also by the Gomori acid phosphatase reaction, while nerve fibers were visualised by the Bodian method. A wave of cell death, beginning in the neural retina at stage 18 and advancing with time through the stalk towards the diencephalon, occurred simultaneously or slightly prior to differentiation and migration of ganglion cell axons. Cell death stopped and gliogenesis occurred in the stalk after penetration by retinal fibers. Cell death occurred in the stalk even when fiber penetration was prevented by optic cup ablation. In this case, necrosis ensued until almost complete degeneration of the stalk, usually within three days after the operation, and gliogenesis did not occur. As the stalk degenerated, its cells became heavily pigmented. These observations suggest that the onset of cell death in the optic stalk is determined prior to and independently of retinal fiber penetration. On the other hand, cessation of cell death and subsequent gliogenesis occur only in the presence of ingrowing optic fibers.

Acid Phosphatase

A new method of determining the solute permeability of hollow-fiber dialysis membranes by means of laser lights traveling along optic fibers.

To develop a new method of determining solute permeability more simply and accurately, the authors employed light from a laser traveling along quartz optic fibers. Dialysis experiments at 310 K were made with a single hollow fiber containing aqueous test solutes. A membrane tube was sealed at either end with quartz optic fibers. Helium-neon and helium-cadmium laser lights emitted from one of these optic fibers into the test solution at wavelengths of 543 and 442 nm for vitamin B12 and cytochrome-C, respectively, were caught by the other optic fiber and detected with a silicon photodiode. The solute permeability for cytochrome-C obtained by this method was almost in agreement with that for beta-2-microglobulin by the radioisotope method. This study demonstrates the usefulness of light from a laser traveling along quartz optic fibers in determining the solute permeability of hollow-fiber dialysis membranes.

Cytochrome c Group

Impulse blockade by intraocular tetrodotoxin during optic regeneration in goldfish: HRP-EM evidence that the formation of normal numbers of optic synapses and the elimination of exuberant optic fibers is activity independent.

Optic fibers and synapses labeled with HRP were counted in the primary optic innervation layer of tectum after continuously blocking visual impulse activity with TTX during regeneration. Normal numbers of optic and nonoptic fibers and synapses were found at both 30 and 60 d, and key ultrastructural features of optic afferents such as fiber fasciculation, myelination, terminal clustering, synaptogenesis onto different classes of postsynaptic targets and general morphology were not notably affected by impulse blockade. These findings indicate that during regeneration the normal proliferation and elimination of optic fibers and the formation of normal numbers of optic synapses are not regulated by activity and are consistent with a pattern formation role for impulse activity rather than a trophic one.

Animals

Development of the retinotectal system in normal quail embryos: cytoarchitectonic development and optic fiber innervation.

The development of the optic tectum and the establishment of retinotectal projections were investigated in the quail embryo from day E2 to hatching day (E16) with Cresyl violet-thionine, silver staining and anterograde axonal tracing methods. Both tectal cytodifferentiation and retinotectal innervation occur according to a rostroventral-caudodorsal gradient. Radial migration of postmitotic neurons starts on day E4. At E14, the tectum is fully laminated. Optic fibers reach the tectum on day E5 and cover its surface on day E10. 'Golgi-like' staining of optic fibers with HRP injected in vitro on the surface of the tectum reveals that: growing fronts are formed exclusively by axons extending over the tectal surface; fibers penetrating the outer tectal layers are always observed behind the growing fronts; the penetrating fibers are either the tip of the optic axons or collateral branches; as they penetrate the tectum, optic fibers give off branches which may extend for long distances within their terminal domains; the optic fiber terminal arbors acquire their mature morphology by day E14. The temporal sequence of retinotectal development in the quail was compared to that already established for the chick, thus providing a basis for further investigation of the development of the retinotectal system in chimeric avian embryos obtained after xenoplastic transplantation of quail tectal primordia into the chick neural tube.

Age Factors

Cross talk in absorbing optical fibers.

Cross talk between neighboring optical fibers is shown to alter the absorption spectrum of the fibers. There is an enhancement of absorption at shorter wavelengths and a consequent shift of the absorption peak towards the short-wavelength end of the spectrum. Curves are presented to illustrate the effect. Results are given in a dimensionless form, applicable to fibers with arbitrary physical parameters.

Absorption

Submicrometer intracellular chemical optical fiber sensors.

A thousandfold miniaturization of immobilized optical fiber sensors, a millionfold or more sample reduction, and at least a hundredfold shorter response time, all simultaneously, were achieved by combining nanofabricated optical fiber tips with near-field photopolymerization. Specifically, pH optical fiber sensors were prepared with internal calibration, making use of the differences in both fluorescence and absorption of the acidic and basic dye species. The submicrometer sensors have excellent detection limits, as well as photostability, reversibility, and millisecond response times. Successful applications include intracellular and intraembryonic measurements. Potential applications include spatially and temporally resolved chemical analysis and kinetics inside single biological cells and their substructures.

Aluminum

Studies of the development of optical fiber sensors for biochemical analysis.

An optical fiber sensor utilizing Thymol blue and an ion-exchange resin complex in a cellulose acetate membrane was developed. By monitoring several different chromophores of Thymol blue, the sensor could measure the pH of the solution from 1.0 to 12.0 with good reproducibility. An optical fiber glucose sensor utilizing a cellulose acetate membrane containing glucose oxidase, 2,7-diaminofluorene dihydrochloride, and sodium N-(3-sulfopropyl)-3,3',5,5'-tetramethylbenzidine was developed. Reflectance changes at 580 nm were large enough to trace changes in glucose concentration in physiological saline solution.

Biosensing Techniques

Intraocular oxygen tension measured with a fiber-optic sensor in normal and diabetic dogs.

A new fiber-optic O2 sensor was used to measure the O2 tension in the living dog eye, and the results were compared with simultaneous O2 tension measurements with polarographic electrodes. The fiber-optic sensor and the polarographic electrodes gave similar readings of anterior chamber O2 tension and gave an identical response to elevation of inspired O2 levels. In the preretinal vitreous, the fiber-optic probe measured the O2 tension 26 +/- 5 mmHg (means +/- SD, n = 5), whereas the polarographic electrode showed 23 +/- 7 mmHg (means +/- SD, n = 5) in the contralateral eyes. Breathing 100% O2 raised the preretinal O2 tension similarly with both systems. Preretinal O2 tension was measured with the fiber-optic sensor in seven alloxan diabetic dogs and was 26 +/- 7 mmHg, which is not significantly different from normal dogs. The fiber-optic sensor has some advantages over the polarographic electrodes. The fiber-optic sensor does not consume O2 and is not dependent on the diffusion characteristics of the medium or changes due to stirring or fluid currents.

Animals

Development of a medical fiber-optic pH sensor based on optical absorption.

A new fiber-optic pH sensor system has been developed. The sensor uses an absorbtive indicator compound with a long wave-length absorption peak near 625 nm; change in absorption over the pH range 6.8 to 7.8 is reasonably linear. The sensor is interrogated by a pulsed, red LED. Return light signal is split into short and long wave-length components with a dichroic mirror; the respective signals are detected by photodiodes, and their photocurrents are used to form a ratiometric output signal. In laboratory tests, the sensor system provided resolution of 0.01 pH, accuracy of +/- 0.01 pH, and response time of 30-40 s. Following gamma sterilization, laboratory sensor testing with heparinized human blood yielded excellent agreement (e.g., r = 0.992 for n = 42) with a clinical blood gas analyzer. Excellent sensor performance and low cost, solid-state instrumentation are hallmarks of this sensor-system design.

Absorption

A new "transducer-tipped" fiber optic catheter for measuring intramuscular pressures.

Laboratory and clinical tests were used to determine the efficacy of a new fiber optic "transducer-tipped" catheter for measuring intramuscular pressures. When pressures ranging from 0 to 250 mm Hg were applied by a mercury manometer, the fiber optic system accurately recorded the pressures. In addition, the fiber optic system showed long-term stability by accurately recording the manometer pressure over a 3 day period. The Slit system showed a higher magnitude of hydrostatic pressure artifacts with catheter tip movement as compared to the fiber optic system. The two catheters showed no difference when measuring pressures in pig muscle at rest or when being compressed throughout a range of 0 to 250 mm Hg. In human volunteers, both catheters measured essentially equal pressures at rest, during venous stasis, and during a combination of venous stasis and compression. For long-term assessment, the Slit system required as many as three saline flushes, whereas the fiber optic system measured pressures continuously without manipulation. We conclude that the fiber optic system is as accurate as the Slit catheter for measuring tissue fluid pressures at rest. In addition, the fiber optic system offers distinct advantages over conventional fluid-filled systems for measuring intramuscular pressures due to a lack of hydrostatic pressure artifacts caused by limb position and to the lack of flushing for long-term measurements.

Adult

The optic tectum regulates the transport of specific proteins in regenerating optic fibers of goldfish.

The pattern of rapidly-transported proteins in regenerating optic fibers of the adult goldfish is regulated by interactions between these fibers and their main target, the optic tectum. When the optic fibers are allowed to interact with the tectum, the transport of proteins with molecular weights in the range of 110-145 kilodaltons (kDa) increases, whereas the transport of proteins in the 24-27 kDa range declines from the previously high level which has been induced by axotomy. If the optic fibers are prevented from interacting with the tectum, the transport of the 24-27 kDa proteins remains elevated for months. Amounts of other rapidly-transported retinal proteins (e.g. the acidic 43-49 kDa proteins that increase in regenerating optic fibers after axotomy) are relatively unaffected by tectal ablation.

Animals

Optic synapse number but not density is constrained during regeneration onto surgically halved tectum in goldfish: HRP-EM evidence that optic fibers compete for fixed numbers of postsynaptic sites on the tectum.

The number of optic synapses in the half tectum of goldfish was counted by using an improved HRP-labeling protocol and a columnar sampling method that spanned the entire optic innervation layer, S-SO-SFGS. It was previously found by using this procedure in intact tectum that the normal number of optic synapses was regenerated by 30 days and maintained thereafter even in the absence of impulse activity. This suggested that the number of synapses in this system was intrinsically fixed. In order to examine whether this limit was imposed by optic fibers or by target cells, optic synapses were counted in surgically halved tecta which received compressed optic projections consisting of regenerating optic fibers from the entire retina. We reasoned that if synapse number is a function of the number of afferents, then there should be twice the normal number of optic synapses per column; on the other hand, if their number is fixed by target, then their number per column should be normal. We found that the number of optic (labeled) synapses was normal in sample columns from fish at 70 days and 160 days after optic nerve crush. Thus, retinal ganglion cells, on average, formed half as many synapses on the half tectum compared to intact tectum, indicating the number of optic synapses was limited by the tectum. The number of nonoptic (unlabeled) synapses was also found to be normal. By contrast, the S-SO-SFGS was found to be 88-103% thicker compared to normal fish, apparently because of a 20-fold increase in the number of optic fibers. As a result, the density of synapses was about half normal in half tecta, and so, in contrast to synapse number, synaptic density is not constrained during regeneration. We infer from these data that optic fibers compete for limited numbers of postsynaptic sites during regeneration and suggest that this competition promotes neural map refinement and the various plasticities described for this projection.

Animals

Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline.

The effect of force applied to a 430 micron single fiber, delivering 60 pulses of 308 nm XeCl laser radiation at 20 Hz, on the ablation depth in porcine aortic tissue under saline has been investigated. Energy densities of 8, 15, 25, 28, 31, 37, and 45 mJ/mm2 were used. Force was applied by adding weights from 0 to 10 grams to the fiber. The fiber penetration was monitored by means of a position transducer. At 0 grams, the ablation depth increased linearly with incident energy density, but the fiber did not penetrate the tissue; with any weight added, the fiber penetrated the tissue at energy densities above 15 mJ/mm2. The fiber did not penetrate during the first several pulses, possibly due to gas trapped under the fiber. After these first pulses, a smooth linear advancement of the fiber began, which lasted until the pulse train stopped. The ablation depth increased with increasing energy densities and weights. This effect was largest above 25 mJ/mm2 where the ablation efficiencies (unit mm3/J), with weights added to the fiber, were substantially larger than values found in 308 nm ablation experiments described in the literature, which were conducted with either a focused laser beam or a fiber without additional force. The results imply that in 308 nm excimer laser angioplasty, force must be applied to the beam delivery catheter for efficient recanalization, and that experiments performed with a focused beam or without actual penetration of the fiber do not represent the situation encountered in excimer laser angioplasty.

Angioplasty, Laser