PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PHOTOELECTRIC CELL”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Blood cell counting and classification by nonflowing laser light scattering method.

We present a nonflowing laser light scattering method for automatically counting and classifying blood cells. A linear charge-coupled device (CCD) and a silicon photoelectric cell (which is placed behind a pinhole plate on the CCD) form a double-detector structure: the CCD is used to detect the scattered light intensity distribution of the blood cells and the silicon photoelectric cell to complete the focusing process. An isotropic sphere, with relative refractivity near 1, is used to model the blood cell. Mie theory is used to describe the scattering of white blood cells and platelets, and anomalous diffraction, red blood cells. To obtain the size distribution of blood cells from their scattered light intensity distribution, the nonnegative constraint least-squares (NNLS) method combined with the Powell method and the precision punishment method are used. Both numerical simulation and experimental results are presented. This method can be used not only to measure the mean and the distribution of red blood cell size, but also to divide the white blood cells into three classes: lymphocytes, middle-sized cells, and neutrocytes. The experimental results show a linear relationship between the blood cell (both white and red blood cells) concentration and the scattered light intensity, and therefore, the number of blood cells in a unit volume can be determined from this relationship.

Adult↗

Ion cyclotron resonance spectroscopy. Cyclotron double resonance provides a new technique for the study of ion-molecule reaction mechanisms.

Ion cyclotron resonance spectroscopy yields information on many aspects of ion-molecule chemistry. The method is ideally suited for experiments involving ion energies below several electron volts, and hence provides a valuable complement to other techniques (27). eyclotron double resonance is uniquely suitable for establishing relationships between reactant ions and their product ions in complex ion-molecule reaction sequences. The double-resonance experiments with isotopic species yield information on reaction mechanisms and the nature of intermediate species. Ion-molecule reactions which occur at low energies are quite sensitive to the nature of functional groups and the details of molecular structure (28). Reactions of ions or neutral molecules with specific reagents in the cyclotron spectrometer can thus be used to characterize unknown species. Once the systematic ion-molecule chemistry of useful reagents has been worked out, it should be possible to proceed in a manner directly analogous to classical chemical methods. Suppose, for example, that reagents A(+), B(+), C(+), and D(+) each have characteristic reactions with different functional groups. Then these reagents can all be mixed with an unknown neutral species, X, and each of the reactions, X + A(+) --> ?, X + B(+) --> ?, . . . . can be examined. In contrast to solution chemistry, all the reagents can be added simultaneously to the unknown, since each of the specific reactions can be examined by cyclotron double resonance. The reactions which occur, the species synthesized , and the products of degradation then characterize X. The same methodology can be applied to characterize an unknown ionic epecies X(+), through use of neutral reagents A, B, C, and D. For example, proton transfer reactions to neuteal species have been applied in studying ions of mass 45 produced from various sources (29). The order of the proton affinities of the neutral reagent molecules are as follows: NH(3) isobutylene propene. Ions of mass 45 can be produced by the protonation of ethylene oxide (see structure III), the protonation of acetaldehyde (see structure IV), and the fragmentation of dimethyl ether (see structure V). Those ions might be expected to have, respectively, the three structures: Proton transfer from the mass-45 ions from sources III and IV to NH(3) and to isobutylene occurs readily, but not proton transfer to propene. For the ion from source V, proton transfer to NH3 occurs, but not proton transfer to isobutylene or propene. Thus the proton transfer reactions to various neutral reagents demonstrate that the mass-45 ions from the various sources are different. This example is only a rudimentary version of an approach to the characterization of unusual ionic species; niore sophisticated applications can follow when the systematic chemistry of more reagents is available. This approach should be ideal for comparing nonclassical carbonium ions produced by different routes. Some very interesting ionic species are produced by rearrangements in the fragmentation of molecules, following electron impact. Such molecular rearrangements frequently result in the fragmentation of an ion radical to another ion radical with the elimination of a small neutral species (30). It should be possible to run these reactions in reverse to check the postulated mechanisms. An interesting result of the systematic study of proton transfer to various functional groups is the finding that the proton affinity of various amines and pyridine is extremely high (31). Species such as VI and VII: might be expected to be very stable; they are in fact so stable that they are unreactive with respect to subsequent chemistry at the charge center. Thus, if there are other functional groups on the ion, the important reactions should occur at these functional groups. It should be possible to design species for which the presence of the charge has little influence on the reactivity of a neutral functional group. In this case the charge functions simply as an inert label which makes the study of neutral-neutral reactions accessible by cyclotron resonance: Various routes for development of the basic technique also appear to be very promising. Echo phenomena following sequences of pulsed excitation have been observed in electron cyclotron resonance (32). Analogous transient phenomena should also occur in ion cvclotron resonances (33). Pulsed-cyclotron-resonance techniques of course have intriguing analogies to nuclear-magnetic-resonance spin-echo experiments (34) and may be the technique of choice for making accurate measurements of ion-molecule-reaction cross sections as a function of energy for low ion energies. Finally, many ion-molecule reactions yield products in excited electronic states (35). For example, the reaction N(2)- + CO --> N(2) + CO- (46) has been studied by beam techniques (36). A straightforward procedure is to observe optical emission from the cyclotron spectrometer by placing a window at the end of the cyclotron cell (37). The emission can be analyzed with a crude set of optical filters, or with a high-speed spectrograph. Optical emission from the cyclotron cell can of course originate from many sources. The radiation from a specific excited product ion can be selected by a radio-frequency-optical double-resonance experiment. If, in the generai reaction A+ + B --> *C+ + D, (47) ion A+ is irradiated at its cyclotron resonance frequency, the number density of optical emitters *C+ is changed. If the irradiating frequency is modulated, then the number of optical emitters will be modulated, so that the intensity of emission from *C+ will also be modulated. When the optical emission from *C+ is analyzed in a spectrograph with a photoelectric cell, the output of the photoelectric cell can be detected with a phase sensitive detector referenced to the modulation frequency. This highly specific modulation-detection scheme should discriminate against other sources of light in the cyclotron cell.

Deuterium↗

Failure of quantitative venous photoplethysmography to assess venous insufficiency: a prospective clinical study.

The increase of deep venous reconstructive surgery necessitates reliable tests for evaluation of the results, which requires quantization of the expelled volume. This could only be done with invasive measurements, but now it seems possible to calibrate photoelectric cells, and quantize the results. Nineteen limbs of patients with deep venous disease and seven limbs of healthy volunteers were evaluated, with methods known from the literature. In addition to measurements in standing position, these methods were used in the more patient-friendly sitting position. Invasively and noninvasively measured recovery times correlated well in the standing (R = 0.83) and in the sitting position (R = 0.86). However, the quantization of expelled volume did not significantly correlate. Also, the differences between expelled volume of controls and patients were only significant with invasive measurements in the standing position (P = 0.006) as well as in the sitting position (P = 0.004). The differences were not significant with the noninvasive method. In our opinion, photoelectric cells still do not offer an alternative for invasive measurements in the evaluation of results after venous reconstructive surgery.

Adult↗

[Efficiency of oxidant gas generator cells powered by electric or solar energy].

Diseases caused by microbial contaminants in drinking water continue to be a serious problem in countries like Mexico. Chlorination, using chlorine gas or chlorine compounds, is one of the best ways to treat drinking water. However, difficulties in handling chlorine gas and the inefficiency of hypochlorite solution dosing systems--due to sociopolitical, economic, and cultural factors--have reduced the utility of these chlorination procedures, especially in far-flung and inaccessible rural communities. These problems led to the development of appropriate technologies for the disinfection of water by means of the on-site generation of mixed oxidant gases (chlorine and ozone). This system, called MOGGOD, operates through the electrolysis of a common salt solution. Simulated system evaluation using a hydraulic model allowed partial and total costs to be calculated. When powered by electrical energy from the community power grid, the system had an efficiency of 90%, and in 10 hours it was able to generate enough gases to disinfect about 200 m3 of water at a cost of approximately N$8 (US $1.30). When the electrolytic cell was run on energy supplied through a photoelectric cell, the investment costs were higher. A system fed by photovoltaic cells could be justified in isolated communities that lack electricity but have a gravity-fed water distribution system.

Chlorine↗