PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PROSTHESIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

[Total hip-joint prosthesis. Critical long-term review of the new McKee Arden CAD stem prosthesis as compared with the usual McKee Arden prosthesis].

The article makes a comparison between the results of total arthroprosthesis operation of the hip with traditional Mckee Arden prosthesis (50 cases operated in the two-year period 1976-77) and those with the new McKee Arden model with C.A.D. stem (52 cases operated in the two-year period 1977-78). All operations were performed at the "G. Pini" Orthopaedic Institute by the same team and with the same surgical technique. The results are based mainly on three parameters (according to McKee): pain, amplitude of movement, and need to use supports. THe Authors conclude by stressing the efficiency of the new model of prosthesis and noting a decrease in intra and post-operative complications.

Adult↗

[Voice restoration with voice prosthesis after total laryngectomy. Assessment of survival time of 378 Provox-1, Provox-2 and Blom-Singer voice prosthesis].

UNLABELLED: Voice Restoration with Voice Prosthesis after Total Laryngectomy. Assessment of Survival Time of 378 Provox-1, Provox-2 and Blom-Singer Voice Prosthesis. BACKGROUND: Indwelling voice prosthesis are used in Trier for voice restoration after total laryngectomy since 1991. OBJECTIVE AND METHOD: To assess the voice prosthesis survival times the patients of the years 1993-1999 are assessed retrospectively. PARTICIPANTS: 58 patients provided with indwelling voice prosthesis were seen regularly at follow-up. 378 prosthesis were changed. Provox 1, Provox 2 and Blom-Singer-Prostheses were used. RESULTS: The average survival lifetime of the prosthesis was 224 days for Provox-1, 96 days for Provox-2 and 107 days for Blom-Singer respectively. There is no significant difference found between Provox-2 and Blom-Singer Prosthesis. The survival times of the Provox-1 Prosthesis is significant longer. CONCLUSION: Using indwelling voice prosthesis for voice restoration after total laryngectomy an average survival time of the prosthesis of three months can be expected. There are relevant individual differences. Provox-1 Prosthesis have a significantly longer survival time, but as they are more difficult to handle they are not suitable for routine use. The indication for the choice between Blom-Singer or Provox-2 Prosthesis should be influenced by the surgeons' experience.

Adult↗

External breast prosthesis use: experiences and views of women with breast cancer, breast care nurses, and prosthesis fitters.

After mastectomy, the provision of an appropriate breast prosthesis can help to improve body image and quality of life and reduce associated emotional distress. Although up to 90% of women use an external breast prosthesis after mastectomy, little is known about their experiences and satisfaction with breast prosthesis use. Focus groups were conducted with women who had been fitted with an external breast prosthesis, breast care nurses, and prosthesis fitters to explore women's experiences of prosthesis use. Qualitative thematic content analysis of focus group transcripts indicated that whereas women's initial reaction to the prosthesis generally was negative, this improved over time. Provision of adequate information and support, characteristics of the fitter and the fitting experience, and relationships with breast care nurses and prosthesis fitters were important to women's acceptance and satisfaction with their prosthesis. The study results highlighted the key role that breast care nurses play and the underestimation of the prosthesis fitter's role. Common themes concerning the impact of prosthesis use included body image, appearance, and feminine identity. These findings have important implications for professionals involved in the delivery of breast prostheses services.

Adaptation, Psychological↗

[Mechanical ileus caused by a Provox voice prosthesis -- an "iatrogenic" enteral complication in voice prosthesis rehabilitation of laryngectomees].

BACKGROUND: During the exchange of a defect Provox-I voice prosthesis followed by an insertion of a Provox-II voice prosthesis the esophageal part of the prosthesis often is pushed into the esophagus, as the enteral passage of the prosthesis was thought to be less traumatic for the voice shunt in comparison to a complete extraction of the stiff esophageal flange through the tracheostoma. This procedure is also recommended in the users video of the ATOS company. CASE: A laryngectomized patient, in whom the change of the voice prosthesis was carried out pushing the esophageal flange of the prosthesis into the esophagus, developed a mechanical ileus, as the voice prosthesis got stuck in Bauhin's valve. This resulted in the necessity of a laparatomy for removal of the voice prosthesis. CONCLUSION: During the replacement of the Provox voice prosthesis it is necessary in all cases that the esophageal remnant of the voice prosthesis either is pulled out of the tracheoesophageal shunt via the tracheostoma or removed with a guide-wire transorally.

Aged↗

Suspension effect and dynamic evaluation of the total surface bearing (TSB) trans-tibial prosthesis: a comparison with the patellar tendon bearing (PTB) trans-tibial prosthesis.

X-ray and cineradiography measurements were used to compare the suspension effect and stability of a TSB trans-tibial prosthesis with an Icelandic Roll-On Silicone Socket (ICEROSS) system to that of a PTB trans-tibial prosthesis. The suspension effect was measured by the distance between the tibia and the socket in both suspension position and weight-bearing position in both type of prostheses. The suspension effect of the TSB prosthesis (2.53 +/- 0.90 cm) was superior to that of the PTB prosthesis (3.60 +/- 0.56 cm) (p < 0.05) by x-ray measurement. The suspension effect of the TSB prosthesis (0.1, 0.4, 0.72 cm) was superior to that of the PTB prosthesis (0.3, 0.48, 1.03 cm) (p < 0.01, p < 0.05) by cineradiographic measurement. The stability was measured as the angle between the axis of the tibia and the prosthesis at the time of heel contact and toe off. The angle change of the TSB prosthesis was statistically smaller than that of the PTB prosthesis.

Adult↗

Women's satisfaction with their breast prosthesis: what determines a quality prosthesis?

The aim of this study is to determine what factors constitute a quality prosthesis and ascertain which factors affect prosthesis satisfaction. Sixty-four women who received full funding for their prosthesis and 38 women who received their hospital's usual funding were recruited. Women rated the information provided about breast prostheses very highly, with 85% reporting that it was "very good" or "excellent." Satisfaction was significantly associated with how well the prosthesis fit (1 week, p = .001; 3 months, p = .01), level of comfort (3 months, p=.005), and appearance of the prosthesis when worn (6 months, p = .001). Quality was significantly associated with how well it fit (1 week, p = .001; 3 months, p = .001), how natural it felt (1 week, p = .001; 6 months, p = .01), the weight of the prosthesis (3 months, p = .003), and appearance when worn (6 months, p = .03). The results will be used to improve women's access to a quality prosthesis.

Adult↗

Improved comfort and function of arm prosthesis after implantation of a Humerus-T-Prosthesis in trans-humeral amputees.

The use of arm prosthesis in trans-humeral amputees is limited; due to the cone form of the amputation stump. A Humerus-T-Prosthesis was implanted in three patients to create artificial humerus condyles. Two of the patients were successfully rehabilitated with the application of a new type trans-humeral arm prosthesis. This arm prosthesis had a socket which is suspended and stabilized by the humerus and implant only. Traction and rotational stability were secured by adjustable pressure adaptation around the artificial condyles. The third patient developed a pressure wound over the lateral part of the artificial condyle that later healed. He also was subject to a new trauma with a fracture of the ipsilateral scapula and until now has had limited the use of his new arm prosthesis. It was concluded that this new concept for prosthesis fitting of trans-humeral amputees looks promising, but alternative designs of the implant should be tested.

Adult↗

Late results after mitral valve replacement with bileaflet mechanical prosthesis in children: evaluation of prosthesis-patient mismatch.

BACKGROUND: Mechanical prosthesis is the choice of valve at the mitral position in children, although re-replacement of prostheses because of prosthesis-patient mismatch is almost inevitable when prostheses were implanted in small children. The methods to predict prosthesis-patient mismatch as a result of patients' somatic growth or pannus formation in children by noninvasive methods have not been well established. METHODS: Thirty-two children underwent mitral valve replacement with 37 bileaflet mechanical prostheses (26 St. Jude Medical prosthetic valves, and 11 CarboMedics prosthetic valves) and were followed up a mean of 6.8 years (maximum 18.3 years) with a complete follow-up rate of 94%. RESULTS: There were no operative deaths and 5 late deaths. Re-replacement of mitral valve because of prosthesis-patient mismatch was required in 5 patients. Freedom from valve-related events and re-replacement of mitral valve at 15 years were 32% +/- 23% and 54% +/- 18%, respectively. Actuarial survival rate was 63% +/- 19% at 15 years. Prosthetic valve orifice area index (manufactured geometric prosthetic valve area divided by patient's body surface area) was well correlated with maximum transprosthesis flow velocity estimated by Doppler echocardiography during follow-up, whereas valve orifice area index had no significant correlation with pulmonary artery wedge pressure assessed by cardiac catheterization. Maximum transprosthesis flow velocity had a significant correlation with pulmonary artery wedge pressure. CONCLUSIONS: Valve orifice area index itself was not a reliable index to predict prosthesis-patient mismatch. Maximum transprosthesis flow velocity was a useful index to predict pulmonary artery wedge. Invasive cardiac catheterization to determine re-replacement of the prosthesis should be considered when maximum transprosthesis flow velocity exceeds 270 cm/s.

Adolescent↗

Development of new tracheal prosthesis: autogenous mucosa-lined prosthesis made from polypropylene mesh.

Reliable tracheal or tissue graft has not been developed yet for the reconstruction of large, circumferential tracheal defects. Major limitations were anastomotic dehishence and stenosis, which were attributed to the poor epithelisation of the prosthetic graft. We developed a new tracheal prosthesis that has a viable lined and well-vascularized mucosa. The prosthesis consists of Prolene mesh reinforced with polypropylene rings, and is coated with gelatin. In addition, we lined the luminal surface of the prosthesis with transplanted autogenous oral mucosa and wrapped the prosthesis with greater omentum. Animal experiments were performed using 10 adult mongrel dogs. The transplanted mucosa and wrapped greater omentum tightly adhered to the prosthesis to make a single unit within two weeks. The mucosa survived well, was well vascularised by new vessels from greater omentum and showed normal histology. Complete surgical resection and replacement of a thoracic trachea (3 cm in length, 6 tracheal rings) were carried out in 2 dogs, which survived well with normal activity. We concluded that this highly biocompatible tracheal prosthesis could be very useful for step-wise reconstruction of tracheal defects.

Animals↗

[Auditory results used to compare a Teflon prosthesis vs a Schucknecht type wire/Teflon prosthesis].

PURPOSE: To compare a Teflon prosthesis to a piston-type wire/Teflon prosthesis assessing auditory results post-Stapedectomy. MATERIAL AND METHODS: We conducted a randomized controlled blinded clinical study from June 2003 to August 2004 at the Otorhinolaryngology, and Head and Neck Surgical Wards at the highly specialized medical unit of "La Raza" General Hospital National Medical Cen ter in Mexico City. The study group was comprised by patients receiving a Teflon prosthesis (Fluoroplastic piston) while the control group received a Schuckneckt type piston wire/Teflon prosthesis. A pre- and post-auditory assessment was done obtaining the average at low, medium and high airway frequencies, the air/bone frequency differences and the total, at the Audiology and Otoneurology Service at the same hospital using a Madzen Minimate 602 brand audiometer. The results were analyzed using SPSS statistical software version 8.0. RESULTS: 138 patients were studied: 68 were included in the study group (Fluoroplastic prosthesis) and 70 in the control group (wire/Teflon prosthesis). A statistically significant difference was found between the groups (p < 0.04) according to the Mann-Whitney U test. The air/bone closure difference was statistically significant (p < 0.001) at low and high frequency ranges for the study group.

Adolescent↗

Surgical and prosthesis-related complications using the Groningen button voice prosthesis.

Prosthesis-assisted tracheoesophageal speech has advanced speech rehabilitation appreciably. However, the surgical technique and the use of a prosthesis may give rise to complications. In a retrospective study on 132 consecutive patients rehabilitated with a Groningen button voice prosthesis, the complications were assessed, the average follow-up being 21 months. Surgical complications were not observed. Prosthesis-related complications, which were encountered in 28%, were all of a minor nature and mainly consisted of granulation formation and hypertrophic scarring; these appeared to be easily treatable. The complications found were few and insignificant in comparison with reports in the literature. This may be attributed to the uncomplicated surgical procedure for the insertion of the Groningen button. Moreover, the prosthesis is self-retaining and requires hardly any care from the patient. Permanent removal of the prosthesis usually requires surgical closure, which is a simple procedure performed under local anaesthesia.

Female↗

A study on the value of the modified KBM prosthesis compared with other types of prosthesis.

A study is reported on the value of a modified KBM prosthesis compared with other types of prostheses. Recently a new type of below-knee prosthesis (the so called modified KBM prosthesis) was introduced in the Netherlands. This prosthesis is now frequently used as a substitute for more conventional types. A study was carried out on the value of this new prosthesis, compared with the more conventional types, by means of a questionnaire sent to a group of patients who formerly used a more conventional type of prosthesis.

Adolescent↗

[Pilot prospective study of prosthesis needs at the prosthesis service of the CCTOS of Abidjan].

Studies on the dental health in Ivory Coast showed that the specific needs in prosthesis are numerous. Are there covered? What are the rates of the prosthetic consumption? It is to this question that the authors of the present work wanted brought a beginning of answer through a pilot prospective survey on the prosthetic demand to the service of prosthesis of the CCTOS of Abidjan. This survey was about 150 patients of all sex and all age come specifically for prosthetic rehabilitation, during the active period of February to April 1994. It takes out again of this survey this following results: from a general epidemiological point of view, the women are more numerous than the men, with an access frequency of 56%. Most topics are young, with an age between 20 and 30 years. The "social" rates that convenient the CCTOS attract the patients whose economic income is little important gladly or that are deprived of a health insurance. The prosthetic antecedents show that more than 65% of the topics never carried mainly a prosthesis for lack information or for lace money. Among the topics that already underwent a prosthetic treatment, prosthesis associate partial resin is the more frequently recovered in spite of an interesting rate of fixed prosthesis (37% of carriers). The clinical data reveal that aesthetic remains the main motive of the consultation, with 58% of demands and the prosthesis associate resin is in more of 70% of the cases the chosen therapeutic option.

Academic Medical Centers↗