Polycarbonates. A preliminary report on the use of polycarbonates as a denture base material.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The purpose of this study was to investigate the torque-deformation characteristics of the following four types of polycarbonate brackets: (1) pure polycarbonate, PPC (anterior Miura, RMO, Denver, Colo.), (2) ceramic reinforced polycarbonate, CRPC (Silkon bracket, American, Sheboygan, Wis.), (3) metal slot reinforced polycarbonate, MRPC (Plastic bracket, Tella Tech, Miami, Fla.), and (4) metal slot and ceramic reinforced polycarbonate, MCRPC (Spirit, Ormco, Glendora, Calif.). A stainless steel bracket, (Mini Diamond, Ormco, Glendora, Calif.), was used as a control. Ten brackets of each type were tested. Each bracket was bonded to a porcelain tooth and engaged in a torquemeter. The tooth-bracket assembly was made stationary by embedding it in die stone. Torsion was applied to the bracket at 4 degrees per minute and the resultant torque (grams.centimeters) and deformation (degree) were measured. For optimum labiolingual tooth movement for a maxillary incisor at 175 grams . centimeters, the amount of angular deflection necessary for the different polycarbonate brackets was the following: (a) 15 degrees for MRPC, (b) 17 degrees for MRPC, (c) 24 degrees for CRPC, and (d) > 30 degrees for PPC. The amount of deformation at this deflection was the least for MRCP followed by MCRPC, CRCP, and PPC. When compared with the stainless steel bracket, all polycarbonate brackets showed significantly (p < 0.0001) higher deformation and lower torque. Within the polycarbonate group, there was a significant difference (p < 0.0001) between each bracket for both measurements. The MRPC produced the highest torque and lowest deformation values followed by the MCRPC, CRCP, and PPC. It appears that only the metal slot reinforced brackets are clinically capable of torquing teeth sufficiently.
Bisphenol A (BPA) is a monomer with estrogenic activity that is used in the production of food packaging, dental sealants, polycarbonate plastic, and many other products. The monomer has previously been reported to hydrolyze and leach from these products under high heat and alkaline conditions, and the amount of leaching increases as a function of use. We examined whether new and used polycarbonate animal cages passively release bioactive levels of BPA into water at room temperature and neutral pH. Purified water was incubated at room temperature in new polycarbonate and polysulfone cages and used (discolored) polycarbonate cages, as well as control (glass and used polypropylene) containers. The resulting water samples were characterized with gas chromatography/mass spectrometry (GC/MS) and tested for estrogenic activity using an MCF-7 human breast cancer cell proliferation assay. Significant estrogenic activity, identifiable as BPA by GC/MS (up to 310 micro g/L), was released from used polycarbonate animal cages. Detectable levels of BPA were released from new polycarbonate cages (up to 0.3 micro g/L) as well as new polysulfone cages (1.5 micro g/L), whereas no BPA was detected in water incubated in glass and used polypropylene cages. Finally, BPA exposure as a result of being housed in used polycarbonate cages produced a 16% increase in uterine weight in prepubertal female mice relative to females housed in used polypropylene cages, although the difference was not statistically significant. Our findings suggest that laboratory animals maintained in polycarbonate and polysulfone cages are exposed to BPA via leaching, with exposure reaching the highest levels in old cages.
In studies to determine whether Saccharomyces cerevisiae produced estrogens, the organism was grown in culture media prepared using distilled water autoclaved in polycarbonate flasks. The yeast-conditioned media showed the presence of a substance that competed with [3H]estradiol for binding to estrogen receptors (ER) from rat uterus. However, it soon became clear that the estrogenic substance in the conditioned media was not a product of the yeast grown in culture, but was leached out of the polycarbonate flasks during the autoclaving procedure. [3H]Estradiol displacement activity was monitored by ER RRA, and the active substance was purified from autoclaved medium using a series of HPLC steps. The final purified product was identified as bisphenol-A (BPA) by nuclear magnetic resonance spectroscopy and mass spectrometry. BPA could also be identified in distilled water autoclaved in polycarbonate flasks without the requirement of either the organism or the constituents of the culture medium. Authentic BPA was active in competitive RRAs, demonstrating an affinity approximately 1:2000 that of estradiol for ER. In functional assays, BPA (10-25 nM) induced progesterone receptors in cultured human mammary cancer cells (MCF-7) at a potency of approximately 1:5000 compared to that of estradiol. The BPA effect on PR induction was blocked by tamoxifen. In addition, BPA (25 nM) increased the rate of proliferation of MCF-7 cells assessed by [3H]thymidine incorporation. Thus, BPA exhibited estrogenic activity by both RRA and two functional bioresponse assays. Finally, MCF-7 cells grown in media prepared with water autoclaved in polycarbonate exhibited higher progesterone receptor levels than cells.grown in media prepared with water autoclaved in glass, suggesting an estrogenic effect of the water autoclaved in polycarbonate. Our findings raise the possibility that unsuspected estrogenic activity in the form of BPA may have an impact on experiments employing media autoclaved in polycarbonate flasks. It remains to be determined whether BPA derived from consumer products manufactured from polycarbonate could significantly contribute to the pool of estrogenic substances in the environment.
OBJECTIVE: Polycarbonate materials are known to exhibit creep. The purpose of this study was to investigate torsional creep of polycarbonate orthodontic brackets. METHODS: Four polycarbonate, one metal, and one ceramic brackets were tested. An in vitro torque apparatus was constructed which applied 2000 g-mm of torque to the bracket slot via a cantilever beam perpendicular to the bracket face. The apparatus was placed in a 37 degrees C water bath. Measurements of the angle of the cantilever beam were made at various times from 1 to 28 d. The initial angular change on loading and subsequent changes with time were compared with ANOVA and Tukey tests at p < 0.5. RESULTS: All but one bracket showed the majority of creep by 2 d. Creep was not judged to be clinically significant for the metal, ceramic and the metal slot-reinforced brackets. The polycarbonate bracket without metal slots demonstrated significantly more creep (p < 0.05) than the polycarbonate reinforced with a metal slot, metal and ceramic brackets. SIGNIFICANCE: Clinically significant bracket slot angle (torque) change due to creep can occur when using polycarbonate brackets without metal slot reinforcement.
The performances and clinical tolerance of a flat plate dialyzer equipped with a polycarbonate polyether copolymer membrane (surface area 1.13 and 0.80 m2, membrane thickness 16 micron) were evaluated in 10 patients, among whom 7 underwent a total of 523 dialysis sessions performed over a 6-month investigation period. Clinical and biological parameters recorded during the study were compared to those observed during an immediately preceding control period during which the same patients were dialyzed with flat plate or hollow fiber Cuprophan dialyzers. The clearances of the 1.13 m2 polycarbonate dialyzer for urea, creatinine, uric acid and inorganic phosphate determined at 36 +/- 14 min after start of the dialysis sessions were found respectively at 132 +/- 23, 103 +/- 22, 120 +/- 23 and 103 +/- 18 ml/min and at significantly higher values (except for uric acid) at the 4th hour of dialysis. The ultrafiltration rate was 490 ml/h for a 100 mm Hg transmembrane pressure and the residual blood volume at the end of dialysis was found at 1.1 +/- 0.3 ml. The main clinical and biological parameters recorded in the 7 patients treated for 6 months with polycarbonate dialyzers were not significantly different from those observed during the preceding control period, although 71% of the polycarbonate dialyzers had a smaller surface area than in those used during the control period. The overall blood leakage rate recorded in 555 polycarbonate dialyzers was 1.08%. No sign or symptom suggestive of clinical intolerance to the polycarbonate membrane was recorded during the entire course of the study.
Clinical as well as laboratory studies have been employed to assess the complement activating potential of polycarbonate membrane hemodialyzers. Blood samples from a group of patients undergoing sequential maintenance hemodialysis with cuprophane, polyacrylonitrile and polycarbonate devices were evaluated to define plasma levels of C3a antigen and leukocyte counts during the initial phases of hemodialysis. While polyacrylonitrile dialyzers did not activate complement to a significant extent, we did observe transient elevations in the plasma concentration of C3a and corresponding diminutions in the granulocyte counts of patients dialyzed with both cuprophane and polycarbonate dialyzers. However, polycarbonate devices appeared to activate complement to a lesser degree than cellulosic dialyzers. Laboratory evaluation of these three different types of dialyzers also provided evidence that polycarbonate membranes did not appear to activate human complement as readily as cuprophane. These observations suggest that polycarbonate membranes display complement-related biocompatibility properties that are intermediate between those of cuprophane and polyacrylonitrile.
Visual acuities (VA) were measured through a series of prisms in order to quantify the blur that results from dispersion in polycarbonate. The mean VA of 40 eyes was reduced from a starting level of 20/13 unaided to 20/31 through 16 prism diopters of polycarbonate. The decline was a linear function of prismatic power. The blurring effect of polycarbonate was significantly greater than that of CR39. The blur from polycarbonate was found to be great enough that it should be taken into account whenever polycarbonate is considered for spectacle lenses. A graphical display is provided which can be used by the clinician to predict the degree of blur from a known polycarbonate lens.
Tyrosine-derived polycarbonates are a new class of degradable polymers developed for orthopedic applications. In this study the long-term (48 week) in vivo degradation kinetics and host bone response to poly(DTE carbonate) and poly(DTH carbonate) were investigated using a canine bone chamber model. Poly(L-lactic acid) (PLA) served as a control material. Two chambers of each test material were retrieved at 6-, 12-, 24-, and 48-week time points. Tyrosine-derived polycarbonates were found to exhibit degradation kinetics comparable to PLA. Each test material lost approximately 50% of its initial molecular weight (Mw) over the 48-week test period. Poly(DTE carbonate) and poly(DTH carbonate) test chambers were characterized by sustained bone ingrowth throughout the 48 weeks. In contrast, bone ingrowth into the PLA chambers peaked at 24 weeks and dropped by half at the 48-week time point. A fibrous tissue layer was found surrounding the PLA implants at all time points. This fibrous tissue layer was notably absent at the interface between bone and the tyrosine-derived polycarbonates. Histologic sections revealed intimate contact between bone and tyrosine-derived polycarbonates. From a degradation-biocompatibility perspective, the tyrosine-derived polycarbonates appear to be comparable, if not superior, to PLA in this canine bone chamber model.
Polycarbonate-based polyurethanes with varying hard segment contents were synthesized. The physical and chemical structures were characterized by using gel permeation chromatography, differential scanning calorimetry, water uptake testing, Fourier transform infrared, and attenuated total reflectance--Fourier transform infrared. The polymers were incubated with cholesterol esterase in a phosphate buffer solution at 37 degrees C over 10 weeks. A higher resistance to hydrolytic degradation was observed in polycarbonate-based urethanes with higher hard segment content. The analysis of the material structures revealed that the degradation of polycarbonate-based urethanes was preferentially initiated at non-hydrogen-bonded carbonates and urethanes. Although the crystallinity of the polycarbonate soft segment may contribute to reducing the hydrolytic degradation catalyzed by cholesterol esterase, it was found to be relatively minor in comparison to the importance of hydrogen bonding between the carbonate and urethane groups. These observations suggest that the biostability of polyurethanes and specifically polycarbonate-based polyurethanes can be improved by manipulating the degree of hydrogen bonding within the materials.
Tyrosine-derived polycarbonates have been identified as promising, degradable polymers for use in orthopedic applications. These polymers are non-toxic, biocompatible, and exhibit good bone apposition when in contact with hard tissue. Tyrosine-derived polycarbonates were designed to incorporate two hydrolytically labile bonds in each repeat unit, a carbonate bond that connects the monomer units and an ester bond connecting a pendent chain. The relative hydrolysis rate of the two bonds will determine the type of degradation products and the degradation pathway of the polymers. In order to study the degradation mechanism of these polycarbonates in more detail, a series of small model compounds were designed that mimic the repeat unit of the polymer. Results obtained from the use of these model compounds suggested that the backbone carbonate bond is hydrolyzed at a faster rate than the pendent chain ester bond. Increasing the length of the alkyl pendent chain lowered the hydrolysis rates of both hydrolyzable linkages, possibly by hindering the access of water molecules to those sites. The hydrolysis rates of both linkages were pH dependent with the lowest rate at pH about 5. The results from this study can be used to explain the degradation behavior of the corresponding polycarbonates as well as their degradation mechanisms. This information is essential when evaluating the utility of tyrosine-derived polycarbonates as degradable medical implant materials.
Thermal elimination reactions on polycarbonates are investigated from both theoretical and experimental points of view, to obtain insight into the microscopic aspects that influence the reaction mechanism and rates. In particular, attention is focused on the influence of the type of substituents in the polymer chain on the reaction rates. Ab initio density functional theory calculations are performed on a series of model compound systems for the polycarbonates under study, in particular carbonates differing by the groups attached at the alpha and beta carbon atoms. Reactants, products, and transition states are optimized at the B3LYP/6-311g level of theory. The structures of the activated complex give insight into the mechanistic details of this type of E(i) elimination reactions. The C(alpha)-O bond dissociates before the C(beta)-H bond, developing some carbocation character in the transition state on the C(alpha) atom. The kinematics of the thermal decomposition reactions have been studied by means of transition state theory by construction of the microscopic partition functions. It turns out that the rates of the E(i) elimination reactions are increased by the presence of those substituents on the C(alpha) and C(beta) carbon atoms which are stabilizing the carbocation character in the transition state. In a second part, degradation temperatures have been experimentally measured for some polycarbonates through thermogravimetric analysis. It is investigated whether the relative rates of the model compound carbonate systems are representative of the behavior of the thermal degradation temperatures in polycarbonates. The study as presented here proves that ab initio calculations on small model systems, which are representative for the active area of the degradation process in polycarbonates, can provide insight into the principal ingredients that govern the reaction rates.
The aim of the present study was to investigate slot deformation and the equivalent torque capacity of polycarbonate brackets with and without a metal slot in comparison with those of a metal bracket. For this purpose, the expansion characteristics and, in a further investigation, the labial crown torque of an upper central incisor, were measured in a simulated intra-oral clinical situation, using the orthodontic measuring and simulation system (OMSS). Three types of bracket with a 0.018 inch slot were tested: polycarbonate Brillant without a metal slot, Elegance with a metal slot and the metal bracket, Mini-Mono. For testing purposes the brackets were torqued with 0.016 x 0.022 inch (0.41 x 0.56 mm) and 0.018 x 0.022 inch (0.46 x 0.56 mm) ideal stainless steel archwires. In the activating experiments, significantly higher torque losses and lower torquing moments were registered with both rectangular archwires with the polycarbonate brackets than with the metal bracket. In the simulation tests, significantly higher torquing moments were registered with the metal bracket than with the polycarbonate brackets. The values for the Elegance bracket were between those of the Mini-Mono and Brillant brackets. The OMSS model approximates the clinical situation, with the torque loss being notably higher than in the in vitro activating experiments. This is due to the adjacent teeth giving the archwire additional play. In addition, the torquing process may twist the archwire, resulting in subsidiary forces. On the basis of the present results, all three brackets can be recommended for torquing. However, in view of the high torque losses, the torques programmed in the straightwire technique must be seen as questionable. Data should be provided by the manufacturer on the bending to be expected in polycarbonate brackets, which has to be offset by additional torque, or the bracket torque should be omitted from the technical specifications.
PURPOSE: Previous work has shown that the impact resistance to blunt missiles is affected by coatings applied to either CR-39 or polycarbonate lenses. We investigated the effects of multiple antireflection (minimum angle of resolution [MAR]) coatings on the resistance of polycarbonate lenses to puncture on impact by sharp, high-speed missiles. METHODS: Four groups of surfaced plano polycarbonate lenses were investigated. Two groups had a scratch-resistant (SR) coating applied to both surfaces. One of these groups had a 2-mm center thickness and the other had a 3-mm center thickness. The other two groups of 2-mm and 3-mm thick lenses had a MAR coating applied over the SR coating. The lenses were impacted by a missile consisting of an industrial sewing machine needle mounted in a cylindrical aluminum carrier. RESULTS: The sharp missiles were able to pierce the lenses at speeds between 29.6 m/s and 46.2 m/s. Impact resistance was lowest for the thinner lenses and lenses with a MAR coating. The effect of the MAR and lens thickness was subadditive. CONCLUSIONS: We have confirmed previous observations that polycarbonate lenses are more susceptible to penetration by sharp, high-speed missiles than blunt missiles. We have also found that reducing lens center thickness and applying a MAR coating further reduces the penetration resistance. Therefore, the use of 2-mm center thickness and MAR-coated polycarbonate lenses should be discouraged for industrial eye protectors where sharp missile hazards are possible.
A survey of the quality of bifocal glass and polycarbonate dress lenses was conducted to determine how well these lenses conform to the ANSI (American National Standards Institute) Z80.1 standard and to identify processing operations that need improvement. Eight different prescriptions were filled with polycarbonate and glass dress lenses by different laboratories. Conformance to the ANSI Z80.1 standard was determined for seven characteristics of individual lenses and one characteristic (vertical prism imbalance) of the pairs of lenses in prescriptions. The results show that 78% of the glass lenses and 43% of the polycarbonate lenses conformed to ANSI Z80.1 for the seven characteristics of individual lenses. For pairs of lenses, 88% of the glass pairs and 71% of the polycarbonate pairs have acceptable vertical prism imbalance. Glass lenses that did not conform failed for a variety of reasons, none of which dominated. Incorrect add power and excessive prism were the major causes of polycarbonate lenses not conforming.
Bisphenol-A polycarbonate has been investigated as an improved polymer for ocular implants, especially for intraocular lenses (IOLs). Polycarbonate properties afford special opportunities for development of tougher, stronger, one-piece IOLs. Autoclave or gamma sterilizability and a higher refractive index may provide additional IOL advantages over polymethylmethacrylate. Implant studies in rabbits have shown polycarbonate IOLs to be well tolerated in the anterior chamber for 2.5 years. Polycarbonate appears promising for new IOLs and other ocular implant applications.
Diphenyl carbonate is an attractive monomer for copolymerization with Bisphenol-A to produce the strong, high melting polycarbonate, Bisphenol-A Polycarbonate. Diphenyl carbonate is an ideal candidate for this polymerization as the phenols constitute good leaving groups during polymerization. Industrially, diphenyl carbonate is produced via the phosgenation of a phenolic sodium salt. Using phosgene creates additional safety hazards as well as concerns in treating or disposing of the reaction by-products. The enzymatic synthesis of diphenyl carbonate via alcoholysis of dimethyl carbonate by phenol is presented. While the process is environmentally benign and eliminates the considerable safety issues related to the use of phosgene, phenol is a poor nucleophile and conversion to diphenyl carbonate is limited. Enzyme catalyzed condensation polymerization of carbonate monomers and diols is a more feasible and direct enzymatic route to polycarbonate. We describe an AA-BB condensation polymerization to make polycarbonates using enzymes at ambient conditions. Molecular weights of up to 8, 500 MW are achieved. Unlike the industrial polymerization, this process is performed without the use of acid catalysts, significant energy input, or high temperature or pressure.
A series of four polycarbonates derived from the ethyl, butyl, hexyl, and octyl esters of desaminotyrosyl-tyrosine was prepared by condensation polymerization. The resulting polymers had weight average molecular weights ranging from 120,000-450,000, and their chemical structure was confirmed by elemental analysis, nuclear magnetic resonance, and Fourier transform infrared spectroscopy. The polycarbonates were evaluated as degradable biomaterials. Their surface properties were determined by electron spectroscopy for chemical analysis, attenuated total reflectance-Fourier transformed infrared spectroscopy, and contact angle measurement. The degree of surface hydrophobicity was related to the length of the alkyl ester pendent chain. The tensile properties were dependent on the chemical structure of the polymers: For thin, solvent cast film specimens, the tensile modulus varied from 1.2-1.6 GPa, and the strength at break from 60-220 MPa. The degradation of polymeric films was followed in vitro by measuring changes in mechanical strength for up to 40 weeks, and the decrease in molecular weight and changes in surface chemistry for up to 80 weeks. The length of the pendent chain affected the degradation behavior and strength retention; the polymers with short pendent chains were more readily hydrolyzable. For sterilization, ethylene oxide treatment was less destructive, as judged by molecular weight retention, than gamma-irradiation. Spin-cast films of all tested polycarbonates were not cytotoxic toward cultured rat lung fibroblasts. The cell response was influenced by the chemical structure of the polymer. The least hydrophobic polycarbonate (having a short ethyl ester pendent chain) was a more stimulating substrate for cell growth than the more hydrophobic polymers (carrying longer alkyl ester pendent chains).