PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “SPECTROMETRY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Comparison of flow injection analysis electrospray mass spectrometry and tandem mass spectrometry and electrospray high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry for the determination of underivatized amino acids.

Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.

Amino Acids↗

Electrospray ionization mass spectrometry of tetrodotoxin and its analogs: liquid chromatography/mass spectrometry, tandem mass spectrometry, and liquid chromatography/tandem mass spectrometry.

Tetrodotoxin (TTX), a powerful sodium channel blocker, usually exists as a mixture of its analogs (TTXs) in natural sources. Due to the structural variation, some analogs are difficult to detect using the postcolumn liquid chromatography-fluorescent detection (LC-FLD) system. Liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) analysis of TTXs can be achieved by a combination of chromatography on a reversed-phase column with long carbon chains (C30) and the mobile phase containing an ion pair reagent (ammonium heptafluorobutyrate). The relationship between the amount of applied standard TTX and its peak area on the mass chromatogram (m/z 320) showed good linearity over a range of 50-1000 pmol. The detection limit for TTX in the selected ion monitoring (SIM) mode was estimated to be 0.7 pmol (signal to noise ratio: 2). The tandem mass spectrometry (MS/MS) scan for the fragment ions of eight TTXs arising from the molecular ions provided characteristic spectra, and the structures of the origins of the prominent fragment ions were proposed. The intense fragment ions of TTX and 11-deoxyTTX were applicable to LC/MS/MS operated in the selected reaction monitoring mode. This method might be useful for further identification of TTXs.

Animals↗

Comparative mass spectrometric analyses of Photofrin oligomers by fast atom bombardment mass spectrometry, UV and IR matrix-assisted laser desorption/ionization mass spectrometry, electrospray ionization mass spectrometry and laser desorption/jet-cooling photoionization mass spectrometry.

Photofrin (porfimer sodium) is a porphyrin derivative used in the treatment of a variety of cancers by photodynamic therapy. This oligomer complex and a variety of porphyrin monomers, dimers and trimers were analyzed with five different mass spectral ionization techniques: fast atom bombardment, UV and IR matrix-assisted laser desorption/ionization, electrospray ionization, and laser desorption/jet-cooling photoionization. All five approaches resulted in very similar oligomer distributions with an average oligomer length of 2.7 +/- 0.1 porphyrin units. In addition to the Photofrin analysis, this study provides a side-by-side comparison of the spectra for the five different mass spectrometric techniques.

Dihematoporphyrin Ether↗

Gas chromatographic determination of organomercury following aqueous derivatization with sodium tetraethylborate and sodium tetraphenylborate. Comparative study of gas chromatography coupled with atomic fluorescence spectrometry, atomic emission spectrometry and mass spectrometry.

Several hyphenated analytical techniques, including gas chromatography (GC) coupled with atomic fluorescence spectrometry (AFS), microwave-induced plasma atomic emission spectrometry (AES), and mass spectrometry (MS), have been evaluated for methylmercury and ethylmercury analysis following aqueous derivatization with both sodium tetraethylborate and sodium tetraphenylborate. Both GC-AFS and GC-AES were shown to be excellent techniques with detection limits in the range of sub-picogram levels (0.02-0.04 pg as Hg). Both techniques have wide linear ranges, although setting of the AFS sensitivity has to be selected manually based on the concentration of mercury in the sample. Phenylation seems to be more favorable in this study because of its capability of distinguishing between ethylmercury and inorganic mercury, and low cost compared to ethylation. Although sensitivity of GC-MS is poor with detection limits ranging from 30 to 50 pg as Hg, it is an essential technique for confirmation of the derivatization products.

Borates↗

Ionspray mass spectrometry of marine toxins. III. Analysis of paralytic shellfish poisoning toxins by flow-injection analysis, liquid chromatography/mass spectrometry and capillary electrophoresis/mass spectrometry.

Ionspray mass spectrometry has been used to monitor the purification of saxitoxin, the parent compound in the family of toxins responsible for paralytic shellfish poisoning (PSP), from a strain of the dinoflagellate Alexandrium excavatum. Quantitative results obtained by flow-injection analysis are compared to those obtained by high-performance liquid chromatography with post-column oxidation and fluorescence detection. The coupling of liquid chromatography and capillary electrophoresis with ionspray mass spectrometry is described for the separation of mixtures of PSP toxins and the highly potent pufferfish toxin tetrodotoxin. Tandem mass spectrometry is used to provide the structural information, and the ability to distinguish isomeric PSP toxins both chromatographically and mass spectrometrically is demonstrated.

Chromatography, High Pressure Liquid↗

The characterisation of selected antidepressant drugs using electrospray ionisation with ion trap mass spectrometry and with quadrupole time-of-flight mass spectrometry and their determination by high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry.

The electrospray ionisation ion trap tandem mass spectrometry (ESI-MS(n)) of selected antidepressant drugs, i.e., citalopram, fluoxetine, mirtazapine, paroxetine, sertraline, and venlafaxine, has been investigated. Sequential product ion fragmentation experiments (MS(n)) have been performed in order to elucidate the degradation pathways for the [M+H](+) ions and their predominant product ions. These MS(n) experiments show certain characteristic fragmentations in that functional groups are generally cleaved from the ring systems as molecules such as H(2)O, amines and phenols. When an aromatic entity is present in a drug molecule together with a nitrogen-containing saturated ring structure as with mirtazapine, fragmentation initially occurs at the latter ring with the former being predictably resistant to fragmentation. Also, when an amine-containing drug molecule such as fluoxetine also contains a functional group, which liberates a phenol with a significantly lower DeltaH(f) (0) value than that of the corresponding amine, the phenol is preferentially liberated. The structures of product ions proposed for ESI-MS(n) can be supported by electrospray ionisation quadrupole-time-of-flight tandem mass spectrometry (ESI-QToF-MS/MS). These molecules can be identified and determined in mixtures at low ng/mL concentrations by the application of high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry (HPLC/ESI-MS(2)), which can also be used for their analysis in hair samples.

Antidepressive Agents↗

Identification of two-dimensionally separated human cerebrospinal fluid proteins by N-terminal sequencing, matrix-assisted laser desorption/ionization--mass spectrometry, nanoliquid chromatography-electrospray ionization-time of flight-mass spectrometry, and tandem mass spectrometry.

Optimal application of biological mass spectrometry (MS) in combination with two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) of human cerebrospinal fluid (CSF) can lead to the identification of new potential biological markers of neurological disorders. To this end, we analyzed a number of 2-D PAGE protein spots in a human CSF pool using spot co-localization, N-terminal sequencing, matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) and nanoliquid chromatography-electrospray ionization-time of flight-mass spectrometry (nanoLC-ESI-TOF-MS) with tandem MS switching. Our constructed CSF master contained 469 spots after image analysis and processing of 2-D gels. Upon visual inspection of our CSF master with the CSF pattern available on the ExPASy server, it was possible to locate and annotate 15 proteins. N-terminal sequence analysis and MALDI-MS peptide mass fingerprint analysis of both silver- and Coomassie Brilliant Blue (CBB) G-250-stained protein spots after in situ trypsin digest not only confirmed nine of the visually annotated spots but additionally resolved the identity of another 13 spots. Six of these proteins were not annotated on the 2-D ExPASy map: complement C3 alpha-chain (1321-1663), complement factor B, cystatin C, calgranulin A, hemoglobin beta-chain, and beta-2-microglobulin. It was clear that MALDI-MS identification from CBB G-250-stained, rather than from silver-stained, spots was more successful. In cases where no N-terminal sequence and/or no clear MALDI-MS result was available, nanoLC-ESI-TOF-MS and tandem MS automated switching was used to clarify and/or identify these protein spots by generating amino acid sequence tags. In addition, enrichment of the concentration of low-abundant proteins on 2-D PAGE was obtained by removal of albumin and immunoglobulins from the CSF pool using affinity chromatography. Subsequent analysis by 2-D PAGE of the fractionated CSF pool showed various new silver-stainable protein spots, of which four were identified by nanoLC-ESI-TOF-MS and tandem MS switching. No significant homology was found in either protein or DNA databases, indicating than these spots were unknown proteins.

Amino Acid Sequence↗

Applications of fast atom bombardment mass spectrometry and fast atom bombardment mass spectrometry-mass spectrometry to the maduramicins and other polyether antibiotics.

Fast atom bombardment mass spectrometry (FAB MS) and fast atom bombardment mass spectrometry-mass spectrometry (FAB MS/MS) were used to study the monovalent glycoside polyether antibiotics maduramicin alpha, beta and delta and the maduramicin alpha salts, their derivatives and degradation products. Also, representative compounds from three major classes of polyether antibiotics were studied: the monovalent polyethers, nigericin and monensin A, the divalent polyether lasalocid A and the monovalent glycoside polyethers septamycin, BL580 delta, etheromycin and carriomycin. The respective FAB fragment and decomposition ions were correlated with the known structures. The FAB spectra of all the polyethers contained metal-adduct molecular ions. Protonated molecular ions were absent. All the polyethers having a beta-hemiketal carboxylic acid group produced an abundant ion, often the base peak of the spectra, 62 daltons less than the corresponding metal-adduct molecular ion. The gas phase mechanism proposed for the formation of this fragment ion is an unusual unimolecular reaction which is initiated by an intramolecular proton transfer from the carboxylic acid to the hydroxy group of the beta-hemiketal, and, then followed by the concerted losses of water and carbon dioxide to produce the corresponding polyether olefin.

Anti-Bacterial Agents↗

Identification of the 'wrong' active pharmaceutical ingredient in a counterfeit Halfan drug product using accurate mass electrospray ionisation mass spectrometry, accurate mass tandem mass spectrometry and liquid chromatography/mass spectrometry.

Methodology is presented for identifying an unknown active (pharmaceutical) ingredient (AI) in a counterfeit drug product. A range of mass spectrometric techniques, i.e., accurate mass mass spectrometry, tandem mass spectrometry (MS/MS) and liquid chromatography/mass spectrometry (LC/MS), has been employed to determine the AI in a counterfeit Halfan suspension, an antimalarial drug. In particular, use of LockSpray accurate mass MS/MS allowed identification of parts of the molecule from fragments, hence limiting the number of possible elemental compositions for the nominal mass of 278 found for the AI in the counterfeit product. The analysis of the isotope pattern observed for the protonated molecule further reduced the number of possible elemental compositions. A literature search for readily commercially available compounds of molecular formula C(12)H(14)N(4)O(2)S suggested that the AI was either sulfamethazine or sulfisomidine. An LC/MS separation of those two compounds and reference MS/MS spectra obtained for sulfamethazine and sulfisomidine led to the conclusion that the AI in the counterfeit Halfan suspension is sulfamethazine, which is an antibacterial agent.

Chromatography, Liquid↗

Studies of organic residues from ancient Egyptian mummies using high temperature-gas chromatography-mass spectrometry and sequential thermal desorption-gas chromatography-mass spectrometry and pyrolysis-gas chromatography-mass spectrometry.

The techniques of gas chromatography-mass spectrometry (GC-MS) and sequential thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) and pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) have been utilised to characterise the constituents of tissue-derived or applied organic material from two Pharaonic Egyptian mummies with a view to identifying embalming practices/substances. The results obtained using TD-GC-MS revealed a series of monocarboxylic acids with the C16:0, C18:1 and C18:0 components dominating in both mummies. The thermal desorption products related to cholesterol, i.e., cholesta-3,5,7-triene and cholesta-3,5-diene (only in Khnum Nakht), were detected in both mummies. Khnum Nakht also contained a number of straight chain alkyl amides (C16-C18) and an alkyl nitrile (C18). Other products included the 2,5-diketopiperazine derivative (DKP) of proline-glycine (pro-gly) which was a major component (7.9%) in Khnum Nakht but only a very minor component in Horemkenesi. Py-GC-MS of samples of both specimens yielded a series of alkene/alkane doublets (Horemkenesi C6-C18, Khnum Nakht C6-C24) which dominated their chromatograms. Series of methyl ketones in the C9-C19 chain length range were also present, with C5-C7 cyclic ketones occurring in Horemkenesi only. These ketones are indicative of covalent bond cleavage, probably of polymerised acyl lipids. Nitrogenous products included nitriles (C9-C18) which were significant in both samples, and amides which were only detected in Khnum Nakht. Also present amongst the pyrolysis products were three steroidal hydrocarbons, cholest-(?)-ene, cholesta-3,5,7-triene and cholesta-3,5-diene. High temperature-GC-MS of trimethylsilylated lipid extracts yielded similar monocarboxylic acids to that obtained using TD-GC-MS, while a series of alpha, omega-dicarboxylic acids and a number of mono- and di-hydroxy carboxylic acids not seen in the thermal desorption or pyrolysis GC-MS analyses were significant constituents in both mummy samples. Overall, the use of GC-MS and sequential TD-GC-MS and Py-GC-MS has demonstrated in both mummies the presence of a complex suite of lipids and proteinaceous components whose compositions indicates extensive alteration via oxidative and hydrolytic processes during long-term interment. None of the classical embalming resins was detected but an exogenous origin for at least a proportion of these components cannot be discounted since fats, oils and gelatin have been proposed as embalming agents in mummification. The combined approach of sequential TD- and Py-GC-MS has potential for application to the characterisation of embalming materials in mummies. Most importantly these techniques virtually eliminate any destruction of the mummified bodies thereby allowing the scope of investigations of ancient Egyptian funerary practices to be significantly extended.

Embalming↗

Assessment of the pollutant elimination efficiency by gas chromatography/mass spectrometry, liquid chromatography-mass spectrometry and -tandem mass spectrometry. Comparison of conventional and membrane-assisted biological wastewater treatment processes.

The elimination efficiency of advanced conventional biological wastewater treatment was compared to membrane-assisted biological wastewater treatment. The sum parameter analyses dissolved organic carbon (DOC) and chemical oxygen demand (COD) or substance-specific analyses such as gas chromatography combined with mass spectrometry, flow injection analysis (FIA-MS) and liquid chromatography (LC-MS) in combination with mass or tandem mass spectrometry (MS-MS) were applied to assess elimination of hardly eliminable compounds in both types of wastewater treatment plants (WWTP). Reduction of DOC and COD in wastewater treatment processes confirmed a favourable elimination efficiency. Substance-specific methods which were applied in addition permitted a qualitative and semi-quantitative assessment of elimination with a visual pattern recognition approach. In order to identify pollutants either the NIST library of electron impact mass spectra for unpolar compounds or the laboratory-made collision-induced dissociation spectra library for polar pollutants was used. To assess elimination efficiency FIA-MS in the selected ion monitoring mode (SIM) besides high selective substance-specific mass spectrometric techniques such as parent ion scans and neutral loss scans were used for quantification. Results proved that membrane-assisted treatment was more effective than advanced biological treatment. In both types of WWTPs predominantly unpolar pollutants were eliminated, while all effluents were dominated by polar compounds of anthropogenic and biogenic origin. These unpolar and polar compounds which had been identified as hardly eliminable are reported about. Quantitative results obtained by FIA-MS, LC-MS and MS-MS for the elimination of alkyl polyglycol ethers, nonylphenol ethoxylates and linear alkylbenzenesulfonic acids from wastewater are presented.

Chromatography, Liquid↗

Analysis of estrogens in river sediments by liquid chromatography-electrospray ionisation mass spectrometry. Comparison of tandem mass spectrometry and time-of-flight mass spectrometry.

A method has been developed and optimised for the determination of two natural estrogens, estrone (E1) and 17beta-estradiol (E2), and one synthetic estrogen, 17alpha-ethynylestradiol (EE2), in river sediments at the sub-ng/g level. This procedure includes microwave-assisted solvent extraction (MASE), solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionisation. Using sediments spiked with the three estrogens at 10 ng/g wet weight, efficient extraction (>92%) of all the three analytes was achieved by MASE, and whole-procedure recoveries ranged from 82 to 98%. Optimisation of the LC separation allowed for substantial reduction of ionisation suppression in the electrospray source to a final level of <18% suppression. Time-of-flight mass spectrometry (TOF-MS) and MS/MS were compared for the analysis of sediment extracts, with the latter technique proving to be the most selective. The method detection limits achieved by LC-MS/MS were 15, 30 and 40 pg/g for E1, E2 and EE2, respectively, which were 13-fold lower than those obtained by LC-TOF-MS. Analysis of river sediments collected from the River Ouse, UK, showed the presence of the natural estrogens at sub-ng/g level. E1 levels ranged from 0.40 ng/g (dry weight) to 3.30 ng/g while E2 levels ranged from <0.03 to 1.20 ng/g and EE2 was never detected (<0.04 ng/g).

Chromatography, Liquid↗

Capillary electrophoresis-mass spectrometry, liquid chromatography-mass spectrometry and nanoelectrospray-mass spectrometry of praziquantel metabolites.

Capillary electrophoresis-mass spectrometry (CE-MS) and liquid chromatography-mass spectrometry (LC-MS) coupling was used for the investigation of metabolites of the anthelmintic drug praziquantel. Human urine samples and microsomal incubation mixtures were investigated after preparation by solid-phase extraction. CE- and LC-MS coupling was performed using an electrospray ionization interface. An ion trap mass spectrometer equipped with a laboratory-made nanoelectrospray ion source was used for the investigation of the glucuronide conjugates by consecutive fragmentations. The nanoelectrospray interface offers the opportunity to perform complicated MSn spectrometric investigations. Different phase I metabolites of praziquantel and their glucuronidated and sulfated conjugates were detected.

Animals↗

Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry.

Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.

Atmospheric Pressure↗

Time-of-flight mass spectrometric analysis of ion formation in hypervelocity impact of organic polymer microspheres: comparison with secondary ion mass spectrometry, (252)Cf mass spectrometry and laser mass spectrometry.

Unisized 1.6-microm polystyrene microspheres coated with PEDOT (polyethylene-dioxythiophene) were accelerated to speeds of 6-16 km/s and shot onto a silver target. Either positive or negative ions, both instantaneously formed by the impact process, have been analyzed by time-of-flight mass spectrometry (TOF). Apparently, the processes that control the formation of ions of either polarity depend on the impact velocity. Comparing the results with those of secondary ion mass spectrometry with primary ion energy in both the elastic and the inelastic ((252)Cf-MS) energy loss regimes, some reaction mechanisms of the polymer ions for different energy densities could be elucidated. Some aspects of ion formation are also related to those found in pulsed laser ion generation from these microspheres. This investigation was performed in order to further improve the method of analyzing the organic fraction of interstellar, interplanetary, and cometary dust particles impinging on the targets of the "CIDA" time-of-flight (TOF) mass spectrometers on-board the NASA comet missions "STARDUST" and "CONTOUR".

Journal Article↗