A simple method for measuring 125I by liquid scintillation counting.

Scintillation solutions containing surface active substances, soluble in Toluene, could be used for efficient counting of 125I. The use of Triton X-114 in the proportion 30% v/v with a Toluene-2,5-Diphenyloxazole basic scintillation solution, provides a method for the measurement of liquid and solid samples with 50% efficiency and aqueous sample capacity up to 25%.

Chorionic Gonadotropin

Evaluation of liquid scintillation counting solutions for radioimmunoassay of hepatitis-associated antigen (HBsAg).

Liquid scintillation counting solutions for radioimmunoassay of hepatitis associated antigen (HBsAg) are evaluated and discussed. Data is also presented which indicates that liquid scintillation counting could be carried out by placing cut-off Ausria-125 test tubes in counting vials containing 10 ml of either Brays, Unogel, or Instagel solutions. The data suggest that Brays was the least effective and Unogel and Instagel were the most effective liquid scintillation counting solutions. This is a fundamental consideration if a laboratory is contemplating an initial investiment in counting equipment. The acquisition of a liquid scintillation counter provides additional capabilities for the clinical laboratory interested in radioisotope measurements. In addition, if a laboratory already has a liquid scintillation counter (Beta counter), the director of the clinical laboratory may elect not to purchase additional counting equipment (gamma counter) since he already has the added advantage of measuring iodine-125 with the Beta counter. The authors propose liquid scintillation (RIA) as an alternative counting system for HBsAg detection in hospital patients and donors.

False Negative Reactions

Cell cycle time determinations based on liquid scintillation counting of 3H-TdR labeled mitotic cells.

Following a 10 min pulse labeling with 3H-TdR, flasks of asynchronous monolayer cultures of Chinese hamster ovary cells were subjected to mitotic selection at 2 hr intervals. The mitotic index of the selected populations was always greater than 90%. Counts per min per cell obtained by liquid scintillation counting were plotted versus time after the pulse label. Comparisons were made between cycle times obtained by the mitotic-scintillation counting method and by the standard per cent labeled mitosis technique. The resulting curves were used for calculations of the cell cycle times and the lengths of G1, S, G2 and M phases of the cell cycle. There was less than 2% difference in the cell cycle times obtained using the scintillation method as compared to times calculated from autoradiographic data obtained from individual petri dishes. The mitotic-scintillation counting technique is simple, accurate and rapid and allows the calculation of the cell kinetics parameters within 1 hr of the end of the experiment.

Autoradiography

A micro-scale method for liquid scintillation counting, applicable to radioimmunoassay of steroids and substances of comparable relative molecular mass.

A major expense of radioimmunoassay involving tritiated tracers is that of liquid scintillation counting. We present a micro-scale method that markedly reduces the cost of liquid scintillation counting. The radioimmunoassay is done in 10 X 50 mm tubes. The antibody-bound tracer is precipitated with a second antibody, the precipitate is resuspended in 0.1 ml of water, and 0.3 ml of dioxane is added. One milliliter of a toluene-based scintillation cocktail is added, and the tube is capped and placed in an adapter for liquid scintilation counting. When this method was applied to a double-antibody testosterone radioimmunoassay, it performed comparably to assays counted by the usual method.

Costs and Cost Analysis

[Liquid scintillation counting of 51chromium. Application to a micromethod of cell-mediated cytotoxic assay (author's transl)].

Detection of gamma emitting isotopes is achieved conventionally by using a gamma spectrometer, or in some cases by liquid scintillation counting. We applied these two methods to the detection of 51 Chromium released in a lymphocyte-mediated cytotoxic reaction. Detection in liquid scintillation appeared more efficient than conventional gamma detection: 16.74% vs 1,11%. It is therefore possible to reduce by a factor of 10 the number of target cells in the cytotoxic assay if liquid scintillation counting is used. Either method gave the same results when applied on the same samples. Liquid scintillation counting is to be preferred when high sensitivity is needed. In addition it offers the advantage of using the same apparatus for detection of gamma or beta emitting isotopes.

Chromium Radioisotopes

A chemiluminescent effect encountered in the liquid scintillation counting of 32P phosphate.

During the course of a kinetic enzyme study of bisphosphoglyceromutase (EC 2.7.5.4.) a chemiluminescent effect was encountered in the liquid scintillation counting of the beta-emission from 32Pi. A method is described for overcoming the effect, thereby permitting the accurate determination of the radioactive compounds. It is important to check for chemiluminescent effects early in the development of new procedures that involve liquid scintillation counting.

Hydrogen-Ion Concentration

A new assay for rapid measurement of MIF levels by 3H-labelled cells in liquid scintillation counting vials: statistical implications for the measurement of migration inhibition.

A new quantitative assay for migration inhibitory factor (MIF) employs 3H-labelled cultured mouse or human lymphoid cells migrating from capillary tubes. Capillaries filled with labelled cells are placed in liquid scintillation counting vials, along with the MIF-containing sample and are removed at the end of a five-hour incubation period. The residual, labelled cells which have migrated out of the tubes are solubilized and counted in a liquid scintillation counter. While cultured lymphoblast cells are routinely used in the assay, the method was checked against mouse and guinea pig peritoneal exudate cells in both the labelled cell technique and the conventional chamber assay. The assay is technically simple to perform and a useful tool for laboratory research purposes because of the short span of time needed to obtain the results. These advantages indicate a potential for automation and use of this assay in a clinical immunology laboratory. Statistical analysis of data from both assays demonstrated that the relative variation among replicates is lower in the labelled cell assay. The new assay also measured a significant difference between controls and MIF-containing samples when the migration index (MI) was greater than 80%. Criteria for significant inhibition of migration are discussed in regard to the use of analysis of variance (ANOVA) and other statistical procedures, and the inadequacy of a single measure, such as the MI, is discussed.

Animals

Comparison of RNA and DNA synthesis, spontaneous and PHa induced, between blood lymphoid cells of newborn infants, older infants, and adults. A study of scintillation counting and by autoradiography.

Spontaneous and PHA induced RNA and DNA synthesis was measured qualitatively by autoradiography and quantitatively by scintillation counting in blood lymphoic cells of newborn infants, older infants, and adults. Spontaneous RNA synthesis was found in transitional cells, large phagocytic lymphoid cells and lymphocytes. Transitional cells and phagocytic lymphoid cells also synthesized DNA spontaneously. Quantitatively, spontaneous RNA synthesis was active in both newborn infants and in adults, but significantly less so in older infants. PHA stimulation for 18 h increased RNA synthesis significantly in blood lymphoid cells of newborn infants and adults, and to a much lesser but still significant degree in older infants. Spontaneous DNA synthesis was significantly greater in newborn infants than in older infants and adults. PHA stimulation for 18 h had no effect on thymidine incorporation in any of the groups studied.

Adult

[The liquid scintillation counting of the 14C natural level in ethanol: a comparison of different standardisation methods (author's transl)].

The influence on liquid scintillation counting efficiency of internal standards toluene-14C, hexadecane-14C and ethanol-14C has been studied for low level-14C measuring of ethanol samples. Many biological and synthetic samples of ethanol have been counted: the best results are obtained with external standardisation on quenching calibration curve made with ethanol-14C. External standardisation on quenching calibration curve made with toluene-14C is preferable to internal standardisation with ethanol-14C. Hesadecane-14C as internal standard gives activities rather higher than true values.

Carbon Radioisotopes

Measurement of 'unscheduled' DNA synthesis in HeLa cells by liquid scintillation counting after carcinogen treatment.

HeLa cells, conditioned in an arginine-deficient medium to reduce DNA S-phase synthesis, were treated with one of four ultimate carcinogens (MNNG, BrMBA, N-acetoxy AAF and EMS) and one precarcinogen, AFB1. All treated cells preferentially incorporated [3H] thymidine as a result of DNA repair monitored by liquid scintillation counting of the extracted DNA. The cells showed some capacity to activate AFB1, but repair synthesis was much increased if a rat liver mixed function oxidase preparation was also present. At equimolar concentrations the various carcinogens stimulated different amounts of DNA repair; this variation was not proportional to the carcinogenic potency of the chemicals tested. Reasons for this are discussed as is the use of this technique as a screen for chemical carcinogens.

Acetoxyacetylaminofluorene