PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Siloxanes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Combinatorial and high-throughput screening of the effect of siloxane composition on the surface properties of crosslinked siloxane-polyurethane coatings.

Libraries of siloxane-polyurethane coatings were designed, formulated, and screened using high-throughput experimentation. Four independent variables that were analyzed were the molecular weight of poly(dimethylsiloxane) (PDMS), presence or absence of poly(epsilon-caprolactone) (PCL) blocks attached to the PDMS backbone, the length of the PCL blocks, and the siloxane polymer level in the coating formulations. In addition to the siloxane libraries (3-aminopropyl-terminated PDMS and poly(epsilon-caprolactone)-poly(dimethylsiloxane)-poly(epsilon-caprolactone) (PCL-PDMS-PCL) triblock copolymers), the coating formulation included a trifunctional isocyanate crosslinker, trifunctional poly(epsilon-caprolactone) polyol, 2,4-pentanedione (pot-life extender), dibutyltin diacetate (catalyst), and a blend of solvents. The resulting coatings were analyzed for their surface energy and pseudobarnacle adhesion both before and after aging the coatings for 30 days in water. The water and methylene iodide contact angle averages increase with increasing molecular weight of PDMS. Coatings prepared from PCL-PDMS-PCL triblock copolymers have lower surface energies than coatings prepared from 3-aminopropyl-terminated PDMS; however, lower pseudobarnacle adhesion results were obtained for the coatings prepared from 3-aminopropyl-terminated PDMS than coatings prepared from PCL-PDMS-PCL triblock copolymers. The siloxane polymer level in the coating formulations does not have a significant effect on the surface energy of the coatings, but it resulted in higher pseudobarnacle adhesion.

Animals↗

Potential estrogenic and antiestrogenic activity of the cyclic siloxane octamethylcyclotetrasiloxane (D4) and the linear siloxane hexamethyldisiloxane (HMDS) in immature rats using the uterotrophic assay.

The cyclic siloxane octamethylcyclotetrasiloxane (D4) and the linear siloxane hexamethyldisiloxane (HMDS) have numerous industrial and consumer applications and thus have the potential for human exposure. The present study was undertaken to examine potential estrogenic and antiestrogenic activities of D4 and HMDS. To address potential differences in sensitivity between rat strains the study used both Sprague-Dawley (SD) and Fischer 344 (F-344) rats. Estrogenicity of the test compounds was determined by measuring absolute and relative uterine weights in immature rats and by monitoring uterine epithelial cell height. In order to place the data obtained for D4 into perspective relative to strong and weak estrogenic compounds, the response produced by D4 at 0, 10, 50, 100, 250, 500, and 1000 mg/kg/day was compared to responses produced by ethinyl estradiol (EE) (1, 3, 10, or 30 microg/kg/day), diethylstilbestrol dipropionate (DES-DP) (0.5, 1.5, 5, 15 microg/kg/day), and coumestrol (CE) (10, 35, 75, 150 mg/kg/day). Antiestrogenic effects were evaluated by co-administering D4 (500 mg/kg/day) with EE at 1, 3, 10, and 30 microg /kg/day. All compounds were administered in sesame oil at a volume of 5 mL/kg by oral gavage. Beginning on postnatal day 18 (SD) or 21 (F-344) each pup (12 per group) received a single dose of test compound once a day for 4 consecutive days. The pups were euthanized the morning after the last treatment and their uteri removed, weighed, and processed for histological examination. EE and DES-DP produced a significant dose-dependent increase in absolute and relative uterine weights and uterine cell height. The maximum increase in uterine weight following EE exposure was approximately 350% relative to controls in both strains. The weak phytoestrogen CE also produced a dose-related increase in absolute and relative uterine weight and epithelial cell height, but the response occurred over a much higher range of doses. At the highest dose of CE, uterine weight was increased approximately 230% relative to controls. Following exposure to D4, absolute and relative uterine weights and uterine epithelial cell height were statistically significantly increased in both strains of rats at doses above 100 mg/kg/day. In terms of uterine weight, D4 was approximately 0.6 million times less potent than EE or DES-DP in SD pups and 3.8 million times less potent than EE or DES-DP in F-344 pups. The maximal increase in uterine weight, relative to controls, produced by D4 at 1000 mg/kg/day was approximately 160% in SD rats, while the maximum increase produced by D4 in F-344 rats was 86%. D4 co-administered over a wide range of EE doses, resulted in a significant reduction in uterine weight compared to EE alone. HMDS was evaluated in SD rats only. The response produced by HMDS (600 and 1200 mg/kg/day) was compared to EE (3 microg/kg/day). Antiestrogenic effects were evaluated by co-administering HMDS (1200 mg/kg/day) with EE at 3 microg/kg/day. HMDS had no measurable effect on uterine weight under the experimental conditions described here. However, HMDS coadministered with EE did produce a small, but statistically significant reduction in uterine weight compared to EE alone. In conclusion, D4 showed weak estrogenic and antiestrogenic activity that was several orders of magnitude less potent than EE, and many times less potent than the weak phytoestrogen CE.

Administration, Oral↗

Hydrophilic poly(vinyl siloxane) impression materials: dimensional accuracy, wettability, and effect on gypsum hardness.

Three hydrophilic poly(vinyl siloxane) impression materials, containing an intrinsic surfactant, were compared with a hydrophobic poly(vinyl siloxane) and a polyether impression material. The hydrophobic poly(vinyl siloxane) material was dimensionally more accurate than the hydrophilic poly(vinyl siloxane) in two of three measured dimensions, but the difference was small. The polyether material was the most wettable, and the hydrophilic poly(vinyl siloxane) were more wettable than the hydrophobic poly(vinyl siloxane). However, when a topical surfactant was used, no difference in wettability was noted between the hydrophilic and hydrophobic poly(vinyl siloxane), and their wettability was comparable to the polyether material, indicating that the topical surfactant was more effective than the intrinsic surfactants. Stone dies made from the hydrophobic poly(vinyl siloxane) material were harder than those obtained from the other materials.

Analysis of Variance↗

Marginal accuracy of indirect provisional restorations fabricated on poly(vinyl siloxane) models.

Indirect interim restorations have been traditionally fabricated on stone casts. Recently, flexible models fabricated from poly(vinyl siloxane) impression material have been suggested in place of stone casts. This study compared the marginal accuracy of indirect single-unit provisional restorations fabricated on stone casts with units made on poly(vinyl siloxane) impression material models. The mean marginal discrepancy of provisional restorations was compared for restorations fabricated from stone, low-viscosity poly(vinyl siloxane), and medium-viscosity poly(vinyl siloxane). Ten restorations were also fabricated directly on a master metal model (control). The mean marginal discrepancies were: control = 0.161 mm; stone model = 0.180 mm; low-viscosity poly(vinyl siloxane) = 0.245 mm; and medium-viscosity poly(vinyl siloxane) = 0.157 mm. The mean marginal discrepancy for the low-viscosity poly(vinyl siloxane) models was significantly higher than the other three groups. No significant difference was found between the control, stone cast, and medium-viscosity poly(vinyl siloxane) model groups.

Analysis of Variance↗

An anionic siloxane polymer as a pseudostationary phase for electrokinetic chromatography.

A novel polymeric pseudostationary phase for electrokinetic chromatography is introduced and characterized. Siloxane polymers are of interest for this application because of the range of chemistries that could be developed based on these backbones, and because successful development of siloxane polymers would make it possible to employ much of the stationary phase chemistry developed in the past thirty years. A commercially available water-soluble siloxane with a hydroxy-terminated alkyl group was converted to the sulfate derivative. This siloxane polymer is water-soluble, effectively eliminating this limitation associated with siloxane polymers. When employed as a pseudostationary phase, this compound provided rapid, efficient, and selective separations. The electrophoretic mobility of the polymer was less than sodium dodecyl sulfate (SDS) and poly(sodium 10-undecenylsulfate), providing a compressed migration time range, which is the main limiting factor for this polymer. The chemical selectivity of the siloxane sulfate was somewhat different than SDS micelles. The siloxane was employed in buffers modified with a large amount of acetonitrile to separate a number of polynuclear aromatic hydrocarbons. The addition of acetonitrile caused an apparent discontinuity in the electrophoretic mobility of the polymer, which may indicate a change in the structure with increasing organic solvent content.

Buffers↗

Synthesis and characterization of novel anionic siloxane polymers as pseudostationary phases for electrokinetic chromatography.

Four novel siloxane polymeric pseudostationary phases with three different ionic head groups have been synthesized and characterized for electrokinetic chromatography. Siloxane polymers are of interest in this application because of the wide range of chemistries that can be developed based on these backbones, including much of the chromatographic stationary phase chemistry developed in the last thirty years. All four of the siloxanes studied were synthesized by modification of a single methylhydrosiloxane polymer with highly acidic anionic functionalities. One of the siloxanes had both ionic groups and alkane chains attached to the siloxane backbone. The electrophoretic mobilities varied from being somewhat less than sodium dodecyl sulfate (SDS) to being much greater than SDS. The siloxanes substituted with ionic groups at all of the silicon sites showed significant nonequilibrium band broadening, severely limiting the efficiencies of these polymers. Substitution of 20% of the silicon sites with an alkyl group improved the efficiency of the separations and the peak symmetry. The chemical selectivities of the siloxane polymers are very different from SDS, but are similar to each other.

Chromatography↗

Cytotoxicity and membrane damage in vitro by inclusion complexes between gamma-cyclodextrin and siloxanes.

Inclusion complexes of gamma-cyclodextrin and octamethylcyclotetrasiloxane (D4), decamethyltetrasiloxane (M10TS), and 1,3,5,7-tetramethyltetravinylcyclotetra - siloxane (TMTV-D4) were prepared to compare the cytotoxic effects of siloxanes in vitro. In these preparations, the hydrophobic siloxanes are surrounded by a hydrophilic shell of eight circularly linked D-glucose molecules (gamma-cyclodextrin), and upon contact with plasma membranes the siloxane molecule can intercalate into the lipid bilayer of the cell membrane. XRPC24, 2-11 plasmacytoma, CH12.LX lymphoma and P388D1 macrophage-like cells were used as indicator cells in toxicity assays. Using an MTT tetrazolium reduction to formazan test, a colorimetric method to determine the number of viable cells, the 50% minimal lethal doses (CD50) for the siloxane compounds were found to range from 30 to 50 microM. Sublethal doses (e.g., 15 microM and lower) resulted in the loss of lactate dehydrogenase (LDH) and glutathione (GSH) from the cytosolic compartment of the target cells and thus indicated cytotoxicity. Treatment of macrophages with siloxanes resulted in a higher production of interleukin-6 (IL-6) than was exhibited by untreated macrophages. The B9 cell bioassay of these treated cells showed as much as a 10 fold higher production (500 U/ml) of IL-6 than did the untreated cells. The degree of increase was dependent on the compound and concentration used. The results of this study show that low molecular weight siloxanes produce lethal effects on B-lymphocyte derived target cells in vitro and permeabilize the plasma membranes at lower sublethal concentrations.

Animals↗

Determination of siloxanes, silicon, and platinum in tissues of women with silicone gel-filled implants.

Silicone [poly(dimethylsiloxane)] gel used in breast implants has been known to migrate through intact silicone elastomer shells, resulting in the clinically observable "gel bleed" on the implant surface. Although silicon concentrations in capsular tissues of women with silicone prostheses have been measured with element-specific silicon analyses, no silicone-specific investigation of these tissues has been performed as yet.A combination of element-specific inductively coupled plasma high-resolution isotope dilution mass spectrometry (ICP-HR-IDMS) and species-specific gas chromatography coupled mass spectrometry (GC-MS) was used to analyze silicon, platinum, and siloxanes in prosthesis capsule, muscle, and fat tissues of women (n=3) who had silicone gel-filled breast implants and in breast tissue of non-augmented women (n=3) as controls.In all tissues of augmented women, siloxanes, in particular octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), and dodecamethylcyclohexasiloxane (D6) were identified. Depending on the siloxane species and type of tissue analyzed, siloxane levels in the range of about 10-1,400 ng g(-1) were detected; total silicon was found in all tissue samples in the range of about 8,900-85,000 ng g(-1). Higher platinum levels ranging from 25-90 ng g(-1 )were detected in fibrin layer and fat tissue of two patients with prostheses. No siloxanes were detected in control breast tissue samples. This investigation of human tissues by a combination of element-specific and species-specific analytical techniques clearly demonstrates for the first time that platinum and siloxanes leak from prostheses and accumulate in their surrounding tissues.

Adipose Tissue↗

Alkyl modified anionic siloxanes as pseudostationary phases for electrokinetic chromatography. I. Synthesis and characterization.

Anionic water soluble siloxane polymers have been synthesized and characterized for electrokinetic chromatography. Siloxane polymers are of interest in electrokinetic chromatography because of the wide variety of chemistries that can be developed based on these backbones, including much of the stationary phase chemistry developed in the last 30 years. The siloxanes in this study have a sulfonate functional group. The siloxanes have different length alkyl chains (C8, C12, C18) attached to the backbone in differing densities. The methylene selectivity generally increases with increasing alkyl chain length and with increasing alkyl chain density. The electrophoretic mobility appears to pass through a maximum as more alkyl chain is added to the siloxane backbone. The efficiency also would seem to pass through a maximum as more alkyl chain is added. The chemical selectivities of the siloxane polymers are very different from sodium dodecyl sulfate but are similar to each other.

Chromatography, Micellar Electrokinetic Capillary↗

Removal of siloxanes in biogases.

Methods for the removal of gaseous silicon compounds in biogases are presented. In laboratory studies, various solid adsorption materials and liquid absorption solutions were evaluated for their siloxane elimination efficiencies. Among the liquid sorbents studied, concentrated nitric acid and sulfuric acid were found to be especially potent siloxane removing agents at elevated temperature. Solid adsorbents tested include activated charcoal, carbopack B, Tenax TA, XAD II resins, molecular sieve 13X and silica gel. Apart from activated charcoal, silica gel showed especially high adsorption capacities of more than 100mg/g for siloxanes. Furthermore, excellent thermal regeneration of the loaded material was possible. The efficiency of silica gel in removing gaseous siloxanes was verified at a sewage treatment plant, where an adsorption bed with silica gel was used for biogas drying. Other gas pretreatment installations studied included refrigeration condensers and adsorbent beds of meadow ore for the catalytic removal of hydrogen sulfide. In contrast to biogas drying by refrigeration, which had a poor effect on siloxane content, the installation of meadow ore adsorption beds resulted in a significant siloxane reduction of 31-75%, depending on the site studied.

Adsorption↗

Physical and biological properties of a novel siloxane adhesive for soft tissue applications.

The aim of this study was to investigate the adhesive properties of an in-house aminopropyltrimethoxysilane-methylenebisacrylamide (APTMS-MBA) siloxane system and compare them with a commercially available adhesive, n-butyl cyanoacrylate (nBCA). The ability of the material to perform as a soft tissue adhesive was established by measuring the physical (bond strength, curing time) and biological (cytotoxicity) properties of the adhesives on cartilage. Complementary physical techniques, X-ray photoelectron spectroscopy, Raman and infrared imaging, enabled the mode of action of the adhesive to the cartilage surface to be determined. Adhesion strength to cartilage was measured using a simple butt joint test after storage in phosphate-buffered saline solution at 37 degrees C for periods up to 1 month. The adhesives were also characterised using two in vitro biological techniques. A live/dead stain assay enabled a measure of the viability of chondrocytes attached to the two adhesives to be made. A water-soluble tetrazolium assay was carried out using two different cell types, human dermal fibroblasts and ovine meniscal chondrocytes, in order to measure material cytotoxicity as a function of both supernatant concentration and time. IR imaging of the surface of cartilage treated with APTMS-MBA siloxane adhesive indicated that the adhesive penetrated the tissue surface marginally compared to nBCA which showed a greater depth of penetration. The curing time and adhesion strength values for APTMS-MBA siloxane and nBCA adhesives were measured to be 60 s/0.23 MPa and 38 min/0.62 MPa, respectively. These materials were found to be significantly stronger than either commercially available fibrin (0.02 MPa) or gelatin resorcinol formaldehyde (GRF) adhesives (0.1 MPa) (P < 0.01). Cell culture experiments revealed that APTMS-MBA siloxane adhesive induced 2% cell death compared to 95% for the nBCA adhesive, which extended to a depth of approximately 100-150 microm into the cartilage surface. The WST-1 assay demonstrated that APTMS-MBA siloxane was significantly less cytotoxic than nBCA adhesive as an undiluted conditioned supernatant (P < 0.001). These results suggest that the APTMS-MBA siloxane may be a useful adhesive for medical applications.

Acrylamides↗

Alkyl-modified siloxanes as pseudostationary phases for electrokinetic chromatography.

Anionic siloxane polymers with novel linker arm structures have been synthesized and characterized with respect to their performance and selectivity as pseudophases for electrokinetic chromatography. The linker arm between the siloxane backbone and the sulfonate head group is shorter and does not have the tertiary amine structure found in the siloxane pseudophases studied previously. This change in the linker arm structure and chemistry has dramatic effects on the chemical selectivity of the pseudophases. Linear solvation energy relationship (LSER) studies show that the greatest contributor to the difference in selectivity is that the new polymers are not as nonpolar as those previously studied. This result indicates that siloxane polymers are not by their nature more nonpolar or hydrophobic than other pseudophases. The LSER studies also demonstrate that siloxane pseudophases have a strong tendency to accept hydrogen bonds that cannot be attributed to the presence of the tertiary amine in the linker arm.

Alkylation↗

Inflammatory response to a novel series of siloxane-crosslinked polyurethane elastomers having controlled biodegradation.

A series of polyurethane polymers was synthesized with increasing proportions of silicone in the form of polydimethylsiloxane (PDMS) utilised as a cross-linking agent, based on an aromatic, non-biostable polyetherurethane (PEtU). Eight formulations ranging from 0-50% PDMS were constructed into porous and non-porous films. These were implanted subcutaneously in rats, both unstrained and 100% strained, for 3 and 6 months. Degradation was determined by FTIR-ATR. Porous films were implanted for 6 and 12 months intramuscularly in both rats and rabbits. These were explanted and examined for inflammatory cell markers by immunohistochemistry. Both low and high percentages of siloxane gave rise to increased degradation, with 20-40% PDMS resulting in the least degradation. Infrared spectral changes correlated well with both visual examination and observation by SEM. Changes to the concentration of siloxane gave rise to differences in the thickness of fibroblastic capsule and infiltration of inflammatory cells in both films & scaffolds. Cellular infiltration was greatest in the films with lower siloxane concentrations. Macrophage activation (MHC-I & MHC-II expression) was least in the higher siloxane variants. It is concluded that by varying the siloxane content in the PEtU matrix we can obtain an acceptable inflammatory response with a relatively short degradation time.

Animals↗

Novel alkyl-modified anionic siloxanes as pseudostationary phases for electrokinetic chromatography. III. Performance in organic-modified buffers.

Anionic water-soluble siloxanes modified with different amounts of alkyl chains have been used as pseudostationary phases in electrokinetic chromatography. Ionic siloxane polymers with attached alkyl chains of C8 and C12 and having different alkyl chain densities have been employed previously to achieve selective and efficient separations with a range of electrophoretic mobilities and methylene selectivities. In this study, the performance of three alkyl-modified siloxanes is examined in different organic-modified buffers and at differing amounts of organic modifier. The organic modifiers used are acetonitrile and methanol. The siloxanes are stable in these organic solvents and show good mobility and good methylene selectivities even at high concentration of organic solvent. Siloxanes have also been used to separate a mixture of 14 polynuclear aromatic hydrocarbons in an acetonitrile-modified buffer.

Anions↗

Efforts directed toward the synthesis of colchicine: application of palladium-catalyzed siloxane cross-coupling methodology.

[reaction: see text] Colchicine is an important and synthetically challenging natural product. The key synthetic step in this approach to the synthesis of colchicine involved a palladium-catalyzed cross-coupling reaction between 5-bromotropolone (4) and an aryl siloxane to form the aryl-tropolone bond. The coupling of a variety of highly functionalized aryl siloxane derivatives was investigated and optimized coupling conditions were developed. It was discovered that a palladium catalyst with a high degree of phosphine ligand coordination (5 equiv of phosphine/mol Pd) was necessary to efficiently couple aryl siloxanes with 5-bromotropolone (4). In addition, the coupling approach has provided a direct comparison between siloxane and boronic acid coupling technologies that demonstrated that aryl siloxanes and boronic acids produce similar yields of highly functionalized biaryl products.

Bromus↗

The measurement of conformational stability of proteins adsorbed on siloxanes.

The paper investigates the conformational stability of bovine serum albumin (BSA) and fibrinogen during 24-h incubation in turn with a linear silicone polymer (polydimethylsiloxane (PDMS)), with linear silicone oligomers (hexamethyldisiloxane and octamethyltrisiloxane) and with cyclic silicone oligomers (octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5)). Ten-fold and 100-fold excesses of siloxanes with respect to the proteins were used. Using fluorescence spectroscopy of tryptophan located in the domain of proteins and fluorescence of 8-anilino-1-naphthalenesulfonic acid (1,8-ANS), which interacts with hydrophobic domains of proteins, changes in the tertiary structure of the protein were recorded. The results demonstrated that BSA does not change its native form during 24-h incubation with siloxanes. In contrast, the tertiary structure of fibrinogen was found to be altered by both short-chain linear siloxanes: (hexamethyldisiloxane and octamethyltrisiloxane) and long-chain PDMS. The changes can be observed only at a 100-fold excess of siloxanes with respect to the protein. No conformational changes in fibrinogen exposed to cyclic siloxanes were observed.

Adsorption↗

Novel alkyl-modified anionic siloxanes as pseudostationary phases for electrokinetic chromatography: II. Selectivity studied by linear solvation energy relationships.

Anionic, water-soluble siloxane polymers modified with different lengths of alkyl chains have very different selectivity than sodium dodecyl sulfate (SDS) micelles when used as pseudostationary phases in electrokinetic chromatography. The siloxanes in this study are random copolymers with side chains bearing sulfonate groups and alkyl groups (C8, C12, or C18), with the proportion of alkyl groups between 10 and 25% of the total. The differences in selectivity have been studied by linear solvation energy relationships (LSERs). The siloxanes in general have been found to be more cohesive, less polar, more able to interact with solutes through n- and pi-electrons, and more able to accept hydrogen bonds than SDS micelles, while the ability to act as hydrogen bond donors is not significantly different than SDS micelles. In addition, the performance in a pH 7.0 Tris buffer has been investigated and the siloxanes were found to have higher methylene selectivities and more variable electrophoretic mobilities than in borate buffers.

Alkylation↗

A modelling assessment of the atmospheric fate of volatile methyl siloxanes and their reaction products.

Volatile methyl siloxanes break down in the atmosphere by reacting with OH radicals to form OH-substituted silanols. As the silanols become increasingly OH substituted they are increasingly likely to be removed from the atmosphere by wet and dry deposition. A simple equilibrium partitioning model was constructed to explore the relative rates of removal by different mechanisms (reaction vs. deposition) for siloxanes and their resultant silanols. A mass balance is calculated for the parent siloxane molecule and for each silanol, characterised by the number of OH substitutions. The model includes the effect of incomplete equilibrium between the vapour, adsorbed and dissolved phases of silanols in the atmosphere using a non-equilibrium factor (epsilon) expressing relative departure from equilibrium. Model results show: (1) maximum vapour-phase concentrations for non-substituted siloxanes and single-OH-substituted silanols; (2) maximum dissolved-phase and adsorbed-phase concentrations for two-OH-substituted silanols; (3) >99% of the original material will be removed in wet deposition and <1% in dry deposition as silanols. For increasing OH-substitutions, the decreasing concentration of precursor molecules (as a consequence of combined removal processes) means that concentrations are negligible, in all phases, beyond three or four substitutions. Predictions were relatively insensitive to assumed departures from phase equilibrium. Predictions of silanol hydrolysis in liquid water droplets suggest that the mix of diol chain lengths in precipitation may not be in thermodynamic equilibrium and will depend on atmospheric residence time and pH.

Atmosphere↗