PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Space Suits”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Compatible atmospheres for a space suit, space station, and shuttle based on physiological principles.

Fundamental physiological principles have been invoked to design compatible environments for a space suit, space station, and the space craft used to transport the astronauts from Earth. These principles include the long-term memory of tissues for a bubble-provoking decompression, the intermittent nature of blood flow in the tight connective tissues(s) responsible for the bends whose incidence in aviators has been shown to be related to bubble volume by the Weibull distribution. In the overall design an astronaut breathing a mixture of 30% O2 in N2 for 4-5 h in a space craft at 11.9 psia can transfer to a space station filled with the same mix at 8.7 psia and, after a further 4-5 h, go EVA at any time without any oxygen prebreathing at any stage. The probable incidence of decompression sickness has been estimated as less than 0.5% using the present suit operating at 4.3 psia but the risk could be reduced to zero if the suit pressure were increased to 6.5 psia.

Aerospace Medicine↗

EVA Suit 2000: a joint European/Russian space suit design.

A feasibility study in 1992 showed the benefits of a common European Russian space suit development, EVA Suit 2000, replacing the Russian space suit Orlan-DMA and the planned European Hermes EVA space suit at the turn of the century. This EVA Suit 2000 is a joint development initiated by the European Space Agency (ESA) and the Russian Space Agency (RKA). The main objectives of this development program are: first utilization aboard the Russian Space Station MIR-2; performance improvement with respect to current operational suits; development cost reduction. Russian experience gained with the present extravehicular activity (EVA) suit on the MIR Space Station and extensive application of European Technologies will be needed to achieve these ambitious goals. This paper presents the current status of the development activities, the space suit system design and concentrates in more detail on life support aspects. Specific subjects addressed will include the overall life support conceptual architecture, design features, crew comfort and operational considerations.

Computer Systems↗

EVA 2000: a European/Russian space suit concept.

For the European manned space activities an EVA space suit system was being developed in the frame of the Hermes Space Vehicle Programme of the European Space Agency (ESA). The space suit was to serve the needs for all relevant extravehicular activities for the Hermes Columbus operations planned to begin in 2004. For the present Russian manned space programme the relevant EVAs are performed by the Orlan-DMA semi-rigid space suit. The origin of its development reaches back to the 1970s and has since been adapted to cover the needs for extravehicular activities on Salyut and MIR until today. The latest modification of the space suit, which guaranteed its completely self-contained operation, was made in 1988. However, Russian specialists considered it necessary to start developing an EVA space suit of a new generation, which would have improved performance and would cover the needs by the turn of the century and into the beginning of the next century. Potentially these two suit developments could have a lot in common based on similarities in present concepts. As future manned space activities become more and more an international effort, a safe and reliable interoperability of the different space suit systems is required. Based on the results of the Munich Minister Conference in 1991, the European Space Agency and the Russian Space Agency agreed to initiate a requirements analysis and conceptual design study to determine the feasibility of a joint space suit development, EVA 2000. The design philosophy for the EVA 2000 study was oriented on a space suit system design of: space suit commonality and interoperability; increased crew productivity and safety; increase in useful life and reduced maintainability; reduced development and production cost. The EVA 2000 feasibility study was performed in 1992, and with the positive conclusions for EVA 2000, this approach became the new joint European Russian EVA Suit 2000 Development Programme. This paper gives an overview of the results of the feasibility study and presents the joint requirements and the proposed design concept of a jointly developed European Russian space suit.

Equipment Design↗

Ensuring of long operation life of the orbiting station EVA space suit.

Russia has gained a lot of experience in operating the space suits (SS) during the extravehicular activities (EVA) by the crews of SALYUT-6, SALYUT-7 and MIR orbiting stations. A total of 21 Orlan-type space suits of various models were operated onboard the orbiting stations (OS) during almost 20 years period. Some of these space suits served up to 3 years in orbit. The paper reviews special features of long SS operation (without return to the Earth) onboard an orbiting station as well as the problems associated with SS repeated use by several crews. An analysis of measures to support solving of the problems of SS long stay and reliable operation onboard the orbiting station is made: selection of a corresponding SS type and separate elements design; selection of the materials; routine and preventive maintenance; development tests. The advantages of the space suit of a semi-rigid type for solving the above problems are shown. The paper includes a short analysis of space suits' operation onboard the Russian orbiting station MIR, and some restuts of inspection of the Orlan-DMA space suit returned to the Earth from orbit by STS-79 alter long operation in orbit. Recommendations on further improvement of the space suits for EVA operations in the International Space Station (ISS) are given.

Decompression Sickness↗

The experience in operation and improving the Orlan-type space suits.

Nowadays significant experience has been gained in Russia concerning extravehicular activity (EVA) with cosmonauts wearing a semi-rigid space suit of the "Orlan" type. The conditions for the cosmonauts' vital activities, the operational and ergonomic features of the space suit and its reliability are the most critical factors defining the efficiency of the scheduled operation to be performed by the astronaut and his safety. As the missions performed by the cosmonauts during EVA become more and more elaborate, the requirements for EVA space suits and their systems become more and more demanding, resulting in their consistent advancement. This paper provides certain results of the space suit's operation and analysis of its major problems as applied to the Salyut and MIR orbiting stations. The modification steps of the space suit in the course of operation (Orlan-D, Orlan-DM, Orlan-DMA) and its specific features are presented. The concept of the suited cosmonauts' safety is described as well as trends for future space suit improvements.

Equipment Design↗

Main problems of the Russian Orlan-M space suit utilization for EVAs on the ISS.

In the recent years the Russian Orlan-M space suits have been improved as applied to their operational requirements for the ISS. A special attention is paid to enhancement of EVA crew efficiency and safety. The paper considers the main problems regarding specific features of the Russian space suit operation in the ISS, and analyses measures on their solution. In particular, the problems associated with the following are considered: enhancement of the anthropometric range for the EVA crewmembers; use of some US EMU elements and unified NASA equipment elements; Orlan-M operation support in the wide range of the ISS thermal conditions; use of Simplified Aid For Extravehicular activity Rescue (SAFER) designed as a self-rescue device, which will be used for an EVA crewmember return in the event that he (she) breaks away inadvertently from the ISS surface. The paper states the main space suit differences with reference to solution of the above problems. The paper presents briefly the design of space suit arms developed for crewmembers with small anthropometric parameters, as well as peculiarities and test results for the gloves with enhanced thermal protection. Measures on further space suit development with the purpose to improve its performances are considered.

Anthropometry↗

The EVA space suit development in Europe.

The progress of the European EVA space suit predevelopment activities has resulted in an improved technical reference concept, which will form the basis for a start of the Phase C/D development work in 1992. Technology development work over the last 2 years has resulted in a considerable amount of test data and a better understanding of the characteristics and behaviour of individual parts of the space suit system, in particular in the areas of suits' mobility and life support functions. This information has enabled a consolidation of certain design features on the one hand, but also led to the challenging of some of the design solutions on the other hand. While working towards an improved situation with respect to the main design drivers mass and cost, the technical concept has been improved with respect to functional safety and ease of handling, taking the evolving Hermes spaceplane requirements into consideration. Necessary hardware and functional redundancies have been implemented taking the operational scenario with Hermes and Columbus servicing into consideration. This paper presents the latest design status of the European EVA space suit concept, with particular emphasis on crew safety, comfort and productivity, in the frame of the predevelopment work for the European Space Agency.

Aerospace Medicine↗

[Russian intra vehicular space suit and cold protection].

During space flights, astronauts use equipment allowing protection against many environmental factors. During tests realised in Russia, space suit efficiency was evaluated particularly concerning cold protection capacity in cold water (3 degrees C) and in cold air (-30 degrees C). Obtained results prove that this equipment allows to prevent hypothermia in cold water and ensure thermal comfort in cold air.

Cold Temperature↗

Design and structural analysis of highly mobile space suits and gloves.

This paper evaluates the factors that control the flexibility of fabric space-suit elements, in particular gloves, by examining a bending model of a pressurized fabric tube. Results from the model are used to evaluate the design strategies used in space-suit components, to evaluate the current direction in research on highly mobile space-suit gloves and to suggest changes necessary for optimum glove fabric selection. Finally it is shown that the modulus of the fabric used in space-suit joint construction is as important to the flexibility of the joint as the glove size and design.

Astronauts↗

The physiology of spacecraft and space suit atmosphere selection.

The majority of the environmental factors which comprise the spacecraft and space suit environments can be controlled at "Earth normal" values, at optimum values, or at other values decided upon by spacecraft designers. Factors which are considered in arriving at control values and control ranges of these parameters include physiological, engineering, operational cost, and safety considerations. Several of the physiological considerations, including hypoxia and hyperoxia, hypercapnia, temperature regulation, and decompression sickness are identified and their impact on spacecraft and space suit atmosphere selection are considered. The past experience in controlling these parameters in U.S. and Soviet spacecraft and space suits and the associated physiological responses are reviewed. Current areas of physiological investigation relating to environmental factors in spacecraft are discussed, particularly decompression sickness which can occur as a result of change in pressure from Earth to spacecraft or spacecraft to space suit. Physiological considerations for long-term lunar or Martian missions will have different impacts on atmosphere selection and may result in the selection of atmospheres different than those currently in use.

Atmospheric Pressure↗

[Thermal physiological analysis of man in an Intravehicular Activity space suit].

OBJECTIVE: To analyze the thermal physiological changes of man in a Intravehicular Activity (IVA) space suit. METHOD: Combined second design was used to arrange 24 tests in 6 young male subjects wearing an IVA space suit at sea level. RESULT: The relationship between common thermal physiological measurements and air ventilating parameters (air temperature, flow rate and its relative humidity) together with metabolic state (rest or work) of man were established in mathematical models. Possible applications of these models were illustrated. Metabolic heat production which influences the relations was also discussed. CONCLUSION: Thermal physiological changes of man in the space suit were properly expressed by the mathematical models in this paper.

Adolescent↗

Extravehicular activity space suit interoperability.

The European Agency (ESA) and the Russian Space Agency (RKA) are jointly developing a new space suit system for improved extravehicular activity (EVA) capabilities in support of the MIR Space Station Programme, the EVA Suit 2000. Recent national policy agreements between the U.S. and Russia on planned cooperations in manned space also include joint extravehicular activity (EVA). With an increased number of space suit systems and a higher operational frequency towards the end of this century an improved interoperability for both routine and emergency operations is of eminent importance. It is thus timely to report the current status of ongoing work on international EVA interoperability being conducted by the Committee on EVA Protocols and Operations of the International Academy of Astronauts initiated in 1991. This paper summarises the current EVA interoperability issues to be harmonised and presents quantified vehicle interface requirements for the current U.S. Shuttle EMU and Russian MIR Orlan DMA and the new European/Russian EVA Suit 2000 extravehicular systems. Major critical/incompatible interfaces for suits/mother-craft of different combinations are discussed, and recommendations for standardisations given.

Equipment Design↗

Model of human/liquid cooling garment interaction for space suit automatic thermal control.

The Wissler human thermoregulation model was augmented to incorporate simulation of a space suit thermal control system that includes interaction with a liquid cooled garment (LCG) and ventilation gas flow through the suit. The model was utilized in the design process of an automatic controller intended to maintain thermal neutrality of an exercising subject wearing a liquid cooling garment. An experimental apparatus was designed and built to test the efficacy of specific physiological state measurements to provide feedback data for input to the automatic control algorithm. Control of the coolant inlet temperature to the LCG was based on evaluation of transient physiological parameters that describe the thermal state of the subject, including metabolic rate, skin temperatures, and core temperature. Experimental evaluation of the control algorithm function was accomplished in an environmental chamber under conditions that simulated the thermal environment of a space suit and transient metabolic work loads typical of astronaut extravehicular activity (EVA). The model was also applied to analyze experiments to evaluate performance of the automatic control system in maintaining thermal comfort during extensive transient metabolic profiles for a range of environmental temperatures. Finally, the model was used to predict the efficacy of the LCG thermal controller for providing thermal comfort for a variety of regiments that may be encountered in future space missions. Simulations with the Wissler model accurately predicted the thermal interaction between the subject and LCG for a wide range of metabolic profiles and environmental conditions and matched the function of the automatic temperature controller for inlet cooling water to the LCG.

Algorithms↗

Fetal 'space-suit' hydrops in the first trimester: differentiating risk for chromosome abnormalities by delineating characteristics of nuchal translucency.

Detecting first trimester fetuses with pan-body hydrops, giving the appearance of a 'space-suit,' is associated with a marked increased risk for chromosome abnormalities. In 30 consecutive fetuses prospectively characterized by space-suit hydrops, detected at or before 13.9 weeks' gestation, 26 (86.7%) were characterized by chromosome abnormalities. However, as opposed to the preponderance of autosome abnormalities among first-trimester fetuses with prominent nuchal translucencies, 15 of the 26 fetuses (57.7%) with abnormal complements were characterized by sex chromosome aneuploidies. Genetic counselling and consideration of invasive prenatal testing is warranted when space-suit hydrops is detected in the first trimester.

Abortion, Therapeutic↗

A theoretical method for selecting space craft and space suit atmospheres.

A theoretical method for selecting space craft and space suit atmospheres assumes that gas bubbles cause decompression sickness and that the risk increases when a critical bubble volume is exceeded. The method is consistent with empirical decompression exposures for humans under conditions of nitrogen equilibrium between the lungs and tissues. Space station atmospheres are selected so that flight crews may decompress immediately from sea level to station pressure without preoxygenation. Bubbles form as a result of this decompression but are less than the critical volume. The bubbles are absorbed during an equilibration period after which immediate transition to suit pressure is possible. Exercise after decompression and incomplete nitrogen equilibrium are shown to increase bubble size, and limit the usefulness of one previously tested stage decompression procedure for the Shuttle. The method might be helpful for evaluating decompression procedures before testing.

Decompression Sickness↗

The European space suit, a design for productivity and crew safety.

In order to fulfill the two major mission objectives, i.e. support planned and unplanned external servicing of the COLUMBUS FFL and support the HERMES vehicle for safety critical operations and emergencies, the European Space Suit System baseline configuration incorporates a number of design features, which shall enhance the productivity and the crew safety of EVA astronauts. The work in EVA is today--and will be for several years--a manual work. Consequently, to improve productivity, the first challenge is to design a suit enclosure which minimizes movement restrictions and crew fatigue. It is covered by the "ergonomic" aspect of the suit design. Furthermore, it is also necessary to help the EVA crewmember in his work, by giving him the right information at the right time. Many solutions exist in this field of Man-Machine Interface, from a very simple system, based on cuff check lists, up to advanced systems, including Head-Up Displays. The design concept for improved productivity encompasses following features: easy donning/doffing thru rear entry, suit ergonomy optimisation, display of operational information in alpha-numerical and graphical form, and voice processing for operations and safety critical information. Concerning crew safety the major design features are: a lower R-factor for emergency EVA operations thru increased suit pressure, zero prebreath conditions for normal operations, visual and voice processing of all safety critical functions, and an autonomous life support system to permit unrestricted operations around HERMES and the CFFL. The paper analyses crew safety and productivity criteria and describes how these features are being built into the design of the European Space Suit System.

Communication↗

[Research progress of thermal control system for extravehicular activity space suit].

New research progress of thermal control system for oversea Extravehicular Activity (EVA) space suit is presented. Characteristics of several thermal control systems are analyzed in detail. Some research tendencies and problems are discussed, which are worthwhile to be specially noted. Finally, author's opinion about thermal control system in the future is put forward.

Aerospace Medicine↗

Highly mobile space suit material optimization.

This paper discusses the factors that control the flexibility of fabric space suit elements by examining a bending model of a pressurized fabric tube. Results from the model are used to evaluate the current direction in highly mobile EVA glove research and suggest that changes are necessary in the suit and glove fabric selection methodology.

Computer Simulation↗