Demonstration of calcium in dermal melanocytes of Xenopus laevis and Poecilia reticulata with electron energy-loss spectroscopy and electron spectroscopic imaging.

The subcellular distribution of calcium in dermal melanocytes of Xenopus laevis and Poecilia reticulata has been analysed. Using two cytochemical methods, phosphate precipitation and a combined oxalate-pyroantimonate technique, electron energy-loss spectroscopy and electron spectroscopic imaging have been applied for elemental analysis. Both precipitation techniques revealed a high calcium content in the melanosomes of both species. Calcium was also located in the vicinity of collagen fibrils and in the plasma membrane.

Animals↗

Reflection electron energy-loss spectroscopy and imaging for surface studies in transmission electron microscopes.

A review is given on the techniques and applications of high-energy reflection electron energy-loss spectroscopy (REELS) and reflection electron microscopy (REM) for surface studies in scanning transmission electron microscopes (STEM) and conventional transmission electron microscopes (TEM). A diffraction method is introduced to identify a surface orientation in the geometry of REM. The surface dielectric response theory is presented and applied for studying alpha-alumina surfaces. Domains of the alpha-alumina (012) surface initially terminated with oxygen can be reduced by an intense electron beam to produce Al metal; the resistance to beam damage of surface domains initially terminated with Al+3 ions is attributed to the screening effect of adsorbed oxygen. Surface energy-loss near-edge structure (ELNES), extended energy-loss fine structure (EXELFS), and microanalysis using REELS are illustrated based on the studies of TiO2 and MgO. Effects of surface resonances (or channeling) on the REELS signal-to-background ratio are described. The REELS detection of a monolayer of oxygen adsorption on diamond (111) surfaces is reported. It is shown that phase contrast REM image content can be significantly increased with the use of a field emission gun (FEG). Phase contrast effects close to the core of a screw dislocation are discussed and the associated Fresnel fringes around a surface step are observed. Finally, an in situ REM experiment is described for studying atomic desorption and diffusion processes on alpha-alumina surfaces at temperatures of 1,300-1,400 degrees C.

Aluminum Oxide↗

Characterization of biological macromolecules by combined mass mapping and electron energy-loss spectroscopy.

The combination of scanning transmission electron microscopy (STEM) and parallel-detection energy-loss spectroscopy (EELS) was used to detect specific bound elements within macromolecules and macromolecular assemblies prepared by direct freezing. After cryotransferring and freeze-drying in situ, samples were re-cooled to liquid nitrogen temperature and low-dose (about 10(3) e/nm2) digital dark-field images were obtained with single-electron sensitivity using a beam energy of approximately 100 keV and a probe current of approximately 5 pA. These maps provided a means of characterizing the molecular weights of the structures at low dose. The probe current was subsequently increased to about 5 nA in order to perform elemental analysis. The 320 copper atoms in a keyhole limpet haemocyanin molecule (mol.wt = 8 MDa) were detected with a sensitivity of +/- 30 atoms in an acquisition time of 200 s. Phosphorus was detected in an approximately 10-nm length of single-stranded RNA contained in a tobacco mosaic virus particle (mol.wt = 130 kDa/nm) with a sensitivity of +/- 25 atoms. Near single-atom sensitivity was achieved for the detection of iron in one haemoglobin molecule (mol.wt = 65 kDa, containing four Fe atoms). Such detection limits are only feasible if special processing methods are employed, as is demonstrated by the use of the second-difference acquisition technique and multiple least-squares fitting of reference spectra. Moreover, an extremely high electron dose (about 10(10) e/nm2) is required resulting in mass loss that may be attributable to 'knock-on' radiation damage.

Animals↗

Localization of Ca(2+)-stores and tissue compartments with a Ca(2+)-binding capacity in the organ of Corti of the guinea-pig by electron energy-loss spectroscopy.

The addition of 10 mM CaCl2 to glutaraldehyde fixative leads to the formation of small electron-dense deposits in the organ of Corti of the guinea-pig. These precipitates are mainly attached to cell membranes in contact with different extracellular lymphatic fluids. A higher number of precipitates is localized in the acellular parts of tectorial and basilar membrane. Electron energy-loss spectroscopy (EELS) was used to determine the elemental composition of the deposits formed. The spectra showed a prominent signal at the Ca2+ L2,3 ionization edge. Oxygen could also be detected in all the precipitates analysed. EELS analysis of mitochondria of the inner and outer hair cells after conventional fixation (glutaraldehyde followed by post-fixation in OsO4) revealed a small but significant calcium signal.

Animals↗

Fluorinated molecule as a tracer: difluoroserotonin in human platelets mapped by electron energy-loss spectroscopy.

The intracellular distribution of fluorine has been delineated in human platelets incubated with 4,6-difluoroserotonin, utilizing a scanning-transmission electron microscope equipped with an energy-loss spectrometer. Discrete intracellular structures corresponding in location to dense bodies contained high concentrations of fluorine. Electron energy-loss spectroscopy, which apparently can detect less than 10(-20) gram of fluorine in an area of 10 square nonometers, can thus localize fluorinated tracer molecules with biological activity.

Blood Platelets↗

Ultrastructural aluminium detection in amphibian tissues by electron spectroscopic imaging and electron energy-loss spectroscopy.

Aluminium causes a variety of toxic effects in living organisms but very little is known about its uptake, pathways and locations of deposition. We have applied electron spectroscopic imaging (ESI) and electron energy-loss spectroscopy (EELS) to locate aluminium at the ultrastructural level in amphibian larvae from acidic ponds. It is found diffusely bound or precipitated in cell organelles. The spatial resolution of aluminium detection is high. The elemental composition of small areas can be demonstrated by EELS. Three different fixation procedures give similar results. The two- and three-window methods at the K- and L-edges are compared.

Aluminum↗

Electron energy-loss spectroscopy analysis of adriamycin-plasma membrane interaction.

Our previous studies on the mechanism of cytotoxic action of the anti-tumour drug adriamycin (ADR) indicated that this anthracyclinic antibiotic strongly modified the molecular architecture of the plasma membrane of human erythrocytes, presumably becoming incorporated within both lipid layers. In order to verify this hypothesis, electron energy-loss spectroscopy (EELS) has been used to compare the P content in control and ADR-treated erythrocyte ghosts. EELS measurements allowed us to reveal a significant reduction in the P/C ratio in erythrocyte ghosts after ADR treatment. This finding seems to reflect a phospholipid 'dilution' produced by the incorporation of the drug molecules in the membrane layers. A structural model of the ADR-membrane interaction is proposed.

Doxorubicin↗

The influence of lens chromatic aberration on electron energy-loss spectroscopy quantitative measurements.

An investigation has been made into the effect of chromatic aberrations of a pre-spectrometer lens system on quantitative elemental analysis by electron energy loss spectroscopy (EELS). In transmission electron microscopy (TEM) diffraction mode, the measured effects are typically 150-330 times larger than if only objective-lens chromatic aberration were important. We discuss several methods of avoiding errors arising from chromatic aberration, including selection of a suitable optical mode (dependent on the desired spatial resolution), adjustment of the TEM imaging system so as to focus the system for a chosen energy loss, and analysis of a large area of a uniform specimen.

Electron Probe Microanalysis↗

About the use of electron energy-loss spectroscopy for chemical mapping of thin foils with high spatial resolution.

Core-loss energy-filtered images have been suggested as a substantial contribution to the development of an analytical electron microscope with high spatial resolution. However, for many problems in complex materials, the characteristic signals can only be detected as slope variations of the continuously decreasing background. Therefore further data processing techniques are needed to extract satisfactorily the true chemical information. A discussion of the present limits and of the existing solutions clearly shows that the method can only be developed at the expense of more elaborate systems such as simultaneous detection channels (quite well suited to the STEM instruments). Typical numbers for realistic situations illustrate the field of application of the technique.

Electrons↗

The application of energy-filtering electron microscopy for the cytochemical localization of Ca(2+)-ATPase activity in synaptic terminals.

The energy-filtering electron microscopical modes of electron energy-loss spectroscopy (EELS) and electron spectroscopic imaging (ESI) have been applied to the cytochemical detection of Ca(2+)-ATPase activity in synaptic terminals in the brain of a cichlid fish. Using a recently developed modification of an enzyme-histochemical method, cerium phosphate was precipitated as a marker of high-affinity Ca(2+)-ATPase activity. This is considered to be a marker for the plasmalemma-bound calcium pump, an enzyme which plays a crucial role in the regulation of the cytoplasmic calcium concentrations and therefore of the reactivity of nerve cells. High-affinity Ca(2+)-ATPase activity is located preferentially at the inner side of synaptic plasma membranes and enables a discrimination of different types of synapse. It is only by using EELS and ESI that the very small amounts of high-affinity Ca(2+)-ATPase reaction product can be analysed reliably and located precisely. These new electron microscopical techniques offer powerful tools for cytochemical studies.

Animals↗

Quantitative analysis of electron energy-loss spectra from ultrathin-sectioned biological material. I. Optimization of the background-fit with the use of Bio-standards.

A computer program for quantitative spectral analysis is proposed for the elemental analysis of biological material by electron energy-loss spectroscopy in a conventional transmission electron microscope, the Zeiss EM902. Bio-standards are used to test the performance of this program. The application of a simplex optimization method for curve-fitting is proposed to separate the ionization edge from the background. Making use of Ce-, Ca- and Fe-bio-standards, this method is compared with Egerton's well-known two-area method.

Calcium↗

Analysis of the calcium distribution in predentine by EELS and of the early crystal formation in dentine by ESI and ESD.

Predentine is a collagen-rich extracellular matrix between the odontoblasts and the dentine with a width of about 15-20 microns. Electron energy-loss spectroscopy of rat incisors shows a significantly higher calcium content in the predentine at the predentine-dentine border than in the middle region of the predentine. At the predentine-dentine border in the dentine, the calcium and the phosphate groups combine to form apatite crystallites. Electron spectroscopic diffraction with zero-loss filtering revealed that the earliest crystallites contain only Debye-Scherrer rings of apatite, which are fewer in number and more diffuse than the diffraction rings from the mature crystallites. We therefore conclude that the early crystallites still contain lattice defects, which are annealed out to some degree with crystal growth. Electron spectroscopic imaging with zero-loss filtering also showed that the earliest crystallites are chains of dots (or small islands); they build up strands composed of islands, which rapidly acquire a needle-like character and coalesce laterally to form ribbon-or plate-like crystallites. The parallel strands sometimes appear to reinforce the macroperiod of the collagen microfibrils (67 nm) by tiny holes without any crystal-substance lined up perpendicular to the parallel strands of the crystallites.

Animals↗

Ultrastructural and electron spectroscopic analyses of cyanobacteria and bacteria.

The extracellular sheath material and some intracellular cell components of cyanobacteria and phosphate-accumulating sewage bacteria were analysed by electron spectroscopic imaging (ESI) and electron energy-loss spectroscopy (EELS). The specimens were embedded in water-soluble Nanoplast resin without any previous fixation and ultrathin sections were examined in a Zeiss CEM 902 microscope. A high sulphur content was detected in the inner sheath of the cyanobacterium Gloeothece. The elemental composition of some cell components and inclusion bodies, such as carboxysomes and cyanophycin, was determined by ESI and EELS. In addition, the phosphate content in specific granules of phosphate-accumulating sewage bacteria was estimated by EELS and nuclear magnetic resonance spectroscopy.

Bacteria↗

The use of parallel EEL spectral imaging and elemental mapping in the rapid assessment of anti-cancer drug localization.

Both electron spectroscopic imaging (ESI) and electron energy-loss spectroscopy (EELS) have great potential for use in several areas of cancer research. In biologically targeted radiotherapy, cytotoxic drug therapy and boron neutron capture therapy the effectiveness of many drugs is often critically dependent upon the intracellular localization of the agent employed. We describe the use of parallel EEL spectral imaging to assess the penetration and location of the iodine-containing drug meta-iodobenzyl guanidine, of potential value in targeted radiotherapy, and for the rapid detection of boron within borate-adsorbed polystyrene beads, of potential value in boron neutron capture therapy. We also describe elemental mapping of boron following low-temperature embedding. These results show how the techniques could be applied to many forms of cancer research by discussing the validity and limitations of the techniques experimentally. We also provide an outline of other areas in this field which could benefit from the future application of ESI and EELS.

3-Iodobenzylguanidine↗

Quantitative analysis of electron energy-loss spectra from ultrathin-sectioned biological material. II. The application of bio-standards for quantitative analysis.

Electron energy-loss spectroscopy (EELS) has been used to determine elemental concentrations in biological specimens, consisting of ultrathin-sectioned cells and tissues. Chelex100-based Ca- and Fe Bio-standards are used for elemental quantification to establish iron and calcium concentrations. These Bio-standards, as well as the biological materials, are treated in a standard EM procedure such that 'known' and 'unknown' sites are located in one cross-section. Uncertainties and variabilities present in the equations for calculating the concentration in the 'unknown' site (determined by comparing simplex-fitted EEL spectra from Bio-standards with those from tissue) are outlined in two examples. Using an H+ Bio-standard, the matrix composition of such biological cell material is analysed, leading to values which approach each other closely. Quantitative EELS, using Chelex100-based Bio-standards, is advocated.

Animals↗

Energy-loss near-edge fine structure and compositional profiles of cryomilled oxide-dispersion-strengthened aluminum.

Spatially resolved electron energy-loss spectroscopy (SREELS) makes possible the identification of small second-phase particles in an oxide-dispersion-strengthened aluminum alloy produced by mechanical alloying in a liquid-nitrogen slurry. Near-edge fine structure profiles based on aluminum L23 features that are characteristic of Al-Al or Al-O bonding yield the metal/oxide fraction as a function of probe position. Profiles of nitrogen fraction are derived from linear sequences of spectra so that detection limits can be analyzed at each point in a scan. Quantitative analysis of these linear profiles shows that particles with diameters in the range 10 to 30 nm are rich in nitrogen. A combination of statistical analysis of background removal results with visual inspection of derivative spectra is used to estimate detection limits.

Aluminum↗

Contrast in the electron spectroscopic imaging mode of a TEM. IV. Thick specimens imaged by the most-probable energy loss.

When the zero-loss transmission falls below 10(-3) for biological sections of mass-thickness greater than 70 micrograms/cm2, the energy window in the electron spectroscopic imaging (ESI) mode of an energy-filtering electron microscope (EFEM) can be shifted to the most-probable energy loss of the electron energy-loss spectrum. This enables mass-thicknesses up to 150 micrograms/cm2 or thicknesses of 1.5 microns to be examined. Electron energy-loss spectra of thick carbon films calculated by a Fourier method agree with experimental spectra. Measurements of the electron energy-loss spectroscopy and ESI image intensities with an additional platinum film confirm a scattering model for the calculation of the image intensity. This model considers the angular broadening at the most-probable energy loss by introducing an effective illumination aperture of the order of the full-width at half-maximum of the angular distribution.

Fourier Analysis↗

Electron spectroscopic study (ESI, EELS) of Nanoplast-embedded mammalian lung.

The potential of Nanoplast melamine resin embedding for the study of mammalian lung parenchyma was examined by means of electron spectroscopic imaging (ESI) and electron energy-loss spectroscopy (EELS). Samples were either fixed with glutaraldehyde-paraformaldehyde or glutaraldehyde-tannic acid, or were directly transferred to the embedding medium without prior fixation. Organic dehydrants, as well as fixatives containing heavy metals and stains, were omitted. A very high level of ultrastructural detail of chromatin, ribosomes, mitochondria and plasma membranes was achieved by ESI from the Nanoplast-embedded samples. The most prominent gain in ultrastructural detail was achieved when moving from an energy loss just below the L2,3 edge of phosphorus at 132 eV to an energy loss just beyond this edge. This reflects the prominent P L2,3 edge observed by EELS of Nanoplast-embedded samples in comparison with conventionally processed samples. Thus, taking into account possible sectioning artefacts, excellent heterochromatin images which rely on the phosphorus distribution can be obtained from Nanoplast-embedded samples by computer-assisted analysis of electron spectroscopic images. In this respect glutaraldehyde-paraformaldehyde fixation is preferable to glutaraldehyde-tannic acid fixation because the presence of silicon, revealed by EELS, in tannic-acid-fixed samples may introduce artefacts in phosphorus distribution images obtained by the three-window method because of the close proximity of the L2,3 edges of silicon and phosphorus.

Animals↗