PubMed HealthSearch

SEARCH · PubMed Health

Results for “Systems Analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Arginine vasopressin metabolism in dogs. II. Modeling and system analysis.

System modeling and analysis methods were applied to interpret data regarding arginine vasopressin (AVP) metabolism in dogs. Based on this analysis a new nonlinear 3-pool model of AVP distribution and disposal was proposed and quantified; the model pools included the plasma, a receptor pool, and an extravascular nonreceptor pool. The receptor pool mediated a portion of the rapid flux of hormone between the plasma and the extravascular pool. Mathematical analysis indicated that the plasma AVP impulse response (bolus) data would be insufficient to uniquely estimate all the model constants, but additional plasma impulse data using 125I-labeled AVP, which does not bind to physiologic hormone receptors, would allow unique model quantification. Other required measurements were the urinary excretion of intact hormone, and plasma AVP degradation. The model was successfully fitted to the data from 10 dogs. The results suggest that, in the normal dogs studied, plasma contained 25% of the total AVP, 19% was bound to receptors, and the remaining 56% was in the extravascular pool. Eighty percent of the flux of AVP from the vascular compartment was mediated by the receptor pool; 98% of AVP degradation occurred in the extravascular pool; and urine excretion and plasma degradation made up the remainder.

Animals

Principles and methods for the quantitative determination of Feulegen stained DNA with the television texture analysis system (TAS).

The television texture analysis system (TAS, Leitz) has been applied to determination of the relative DNA content of Feulgen stained nuclei. The principles of the method are described and comparative measurements are presented. The determination is based on the measurement of areas at preset intervals of transmittance, taking into consideration the necessary correction of extinction values in relation to area and applying a correction for background. The data obtained can be used for the quantitative determination of DNA, and to provide analytical information for quantitation of structure. Comparison of the mean of extinctions as recorded with the scanning photometric method and those recorded with the television texture analysis method, with which 43 nuclei were investigated in transmittance steps of 0.01, revealed a coefficient of correlation of 0.9938.

Amnion

Nonlinear systems analysis: comparison of white noise and sum of sinusoids in a biological system.

The Gaussian white noise and the sum-of-sinusoids methods of systems analysis provide equivalent descriptions of nearly linear and strongly nonlinear transductions in the cat retina. Smoothness in the frequency domain is a common characteristic of biological transductions. This permits a substantial improvement in the signal-to-noise ratio by using the sum-of-sinusoids method, as is demonstrated for the transductions of the cat retina.

Animals

A systems analysis approach to planned change in a clinical psychiatric program.

In health car facilities, systems studies are commonly conducted as ivory-tower operations with minimal impact and little practical result. A real-life case study was presented to demonstrate how it can be used effectively in a collaborative manner to implement constructive change. Systems Analysis techniques were succe-sfully used with the staff of a psychiatric ward to plan for a satellite outpatient treatment program. The focus was on collaboration to help the ward to obtain objective information for decisions concerning the need for changes in their existing system.

California

Systems analysis of an aeromedical evacuation mission.

The author applies general systems theory to the analysis of a social system. Through an examination of information processing in an aeromedical evacuation mission, more meaningful levels of coordination evolve. Thus system analysis, as applied here, is an approach used to not only describe an organization but, more importantly, to clearly discern the interrelationships inherent in an activity of major significance such that change or improvement, if needed, may the more readily result.

Aerospace Medicine

An image analysis system for cervical cytology automation using nuclear DNA content.

An experimental computer/image analysis system has been used to investigate cytology automation techniques based on nuclear DNA measurement and morphological artefact rejector tests. The system automatically measures and normalizes the integrated optical density of cell nuclei in specially prepared cervical cytology specimens, and selects any objects with abnormally high values for further analysis. These are then analyzed by morphological and densitometric tests designed to eliminate false positive signals caused by non-nuclear artefacts. The coordinates of the remaining abnormal nuclei are recorded so that they can subsequently be relocated and examined by a cytotechnician. Preliminary results are given showing the measurement accuracy of the system and the performance of the artefact rejection tests.

Cell Nucleus

An automated dosimetry data-acquisition and analysis system at the LAMPF pion therapy facility.

An automated data-acquisition and analysis system has been developed for dosimetry measurements on the pion therapy beam at the Clinton P. Anderson Meson Physics Facility Biomedical Channel in Los Alamos using a PDP-11/45 computer and CAMAC interface. Initialization, test, and monitor programs allow the user to set the physical limits of scanner travel, test the data lines, calibrate the analog signals for the scanner position, and monitor the analog versus digital values of the scanner position during operation. Data-acquisition programs scan beams in one, two, and three dimensions. Many options are available to the user in selecting the scan parameters and in changing some of these parameters during scanning. Data-analysis programs provide reproduction of stored data, comparison of linear scans, beam profiles along any line of a planar or volume scan, and isodose distributions from any planar scan or from any planar scan or from any plane of a volume scan. Other programs summarize stored data files and search for specific data according to the user's instruments.

Computers

SCANCANS--an interactive scanning cell analysis system.

This paper describes a computerized, general-purpose, interactive, scanning cell-analysis system developed at the Department of Clinical Cytology of the University Hospital in Uppsala. The system uses a Leitz MPV II scanning photometer, a PDP-8 computer with 24 k of core memory and a Tektronix 4010 graphic display terminal. A command interpreter and overlay structure which makes it simple to add new capabilities to the system is described. Some examples of command strings and the kind of operations the system can perform are included. Finally, the experience gained from using the system and some plans for future extensions are discussed.

Autoanalysis

Quantification of human sperm morphology and motility by means of semi-automatic image analysis systems.

Sperm morphology and motility are determined using a semi-automatic image analysis system under opto-manual control. The system consists of a microscope equipped with a drawing-tube, a digitizer-tablet, and a cursor interfaced to a small microcomputer. A light-emitting diode is mounted on the cursor, visible as a bright red pilot-light in the microscopic field. Sperm head and midpiece as well as the pathway of motile spermatozoa are traced with the cursor's red pilot light. The microcomputer calculates area, circumference, and length simultaneously. Motility and sperm density are determined altogether using microchamber technique. In a selected group of male subjects with normal, doubtful, and pathological semen analyses biometrical analyses of sperm morphology and motility were performed. Sperm morphology is best described by the variation of the head size and by the average midpiece width. Motility is best described by % motile spermatozoa and mean velocity determined 1 hour after semen collection. Biometrical semen analyses are superior to subjective evaluations regarding degree of information, objectivity, and reproducibility.

Cell Survival

The role of operations research and systems analysis in holding down the costs of hospitals and clinics.

In the past, medical care facilities have concentrated primarily on professional clinical evaluation. With the cost of treatment rising rapidly, it is becoming increasingly important to critically review and analyze our delivery systems so that scarce resources can be used optimally. In this paper the applications of operations research (O.R.) and systems analysis techniques that have been employed successfully in private industry are explored to find ways to improve clinical operations and hold costs down.

Costs and Cost Analysis

Detection of suspicious cells and rejection of artefacts in cervical cytology using the Leyden Television Analysis System.

In slide based automation of cervical cytology the first stage of analysis involves finding possibly suspicious cells, or areas on the slide with these types of cells. By using a television based system such as the Leyden Television Analysis System (LEYTAS), a number of detection methods can be applied to rapidly screen a large number of fields automatically for suspicious cells. In this paper, results using a parameter based on increased nuclear DNA content of cells are given and a second detection method based on a chromatin pattern feature, called chromatin contrast, is discussed. Two blind trials on 41 positive and 22 negative cervical slides, using the Leyden Television Analysis System to detect suspicious cells with an increased nuclear DNA content, were promising. In 1 of the 41 positive cases no suspicious cells were found. In the negative specimens, suspicious cells were detected in 1 of 9 cases and 1 of 13 cases, with the two detection parameters investigated. These findings are discussed and some automatic artefact rejection procedures with preliminary results are given.

Cervix Uteri

A microcomputer-based data acquisition and analysis system for CO2 rebreathing studies.

A real-time microcomputer-based data acquisition and analysis system has been developed to automate the measurement of the ventilatory response to CO2 by the rebreathing method. Previous systems acquire the data on-line and then analyze and display the results off-line. The system described here performs all processing on-line and displays experimental results in real-time. The results of 5 min of data acquisition are available for display only 1.5 sec after completion of the experiment. Immediate interpretation of the results of each experiment enable a series of related studies to be performed on the same patient in a short time period. The microcomputer is Digital Equipment Corporation's LSI-11, a low cost 16 bit machine with the basic instruction set of a PDP-11/40. The system has 16 kbytes of memory, a CRT for data display, and a paper tape reader for program loading. Due to the time constraints of real-time processing and the memory constraints of a small system, the software is written entirely in assembler language. The software includes routines for numeric and character input, line and graphical output, linear curve fitting, start of rise detection and floating point computations.

Carbon Dioxide

An automated fluorescent excitation analysis system for medical applications.

The use of stable tracers assayed by x-ray fluorescent excitation analysis has proven advantageous over other stable or radioisotopic techniques in a number of clinical and investigative situations. An automated fluorescent excitation analysis system for medical application has developed. Its design parameters and performance are described.

Blood Volume Determination

The cross sectional area of diaphragmatic muscle fibres in emphysema, measured by an automated image analysis system.

The cross-sectional area of diaphragmatic muscle fibres was measured using a Quantimet 720 image analysis system in 18 patients with emphysema and six control non-emphysematous patients. The technique proved to be an accurate method of measuring muscle fibre area and much more rapid than the previously described methods. The mean cross-sectional area of the muscle fibres in the emphysematous group was 1069-5 mum2 and this was significantly greater than the mean of the control group which was 851-0 mum2. In the emphysematous group nine patients who died from chronic airways obstruction had a larger mean muscle fibre area than the nine patients with non-fatal respiratory disease. The emphysematous patients showed a marked increase in the number of very large muscle fibres (2000-2200 mum2) in the diaphrahm and also an increased variation in size from fibre to fibre. The increase in muscle fibre size showed a positive correlation with ventricular weight but not with the amount of emphysema in the lungs. It would appear that although the excursion of the diaphragm is reduced in emphysema the muscle fibres do not atrophy but in fact undergo work hypertrophy. This is presumably due to the horizontal shortening of the muscle fibres, when the diaphragm is working at a poor mechanical advantage, because it cannot descend normally in emphysematous patients.

Adolescent