PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tandem Mass Spectrometry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Analysis of single nucleotide polymorphism sites in exon 4 of the p53 gene using high-performance liquid chromatography electrospray ionization mass spectrometry tandem mass spectrometry.

Three groups of four oligonucleotides with special single nucleotide polymorphisms (SNP) sites in exon 4 of the p53 gene were analyzed with ion-pair reversed-phase high-performance liquid chromatography electrospray ionization mass spectrometry tandem mass spectrometry. The retention order of four oligonucleotides with SNPs was C < G < A < T, regardless of whether the polymorphisms were at the 3' end, the 5' end, or the middle of the oligonucleotides. The charge state of the molecular ion affects the MS/MS spectra of the oligonucleotides. SNPs at the 3' end can be easily identified from the fragmentation pattern of the 2- charge state, but not from the 3- charge state, especially from the w1 fragment. The single base may be taken as the symbol of the 5' end SNP site derived from [M3H]2, but not from the [M3H]2 charge state. The oligonucleotides with SNPs in the middle were also determined from the [M2H]2 precursor ion.

Chromatography, High Pressure Liquid↗

Characterization of O-glycosylation sites in recombinant B-chain of platelet-derived growth factor expressed in yeast using liquid secondary ion mass spectrometry, tandem mass spectrometry and Edman sequence analysis.

High-performance tandem mass spectrometry has been employed to structurally characterize intact O-linked glycopeptides and establish the complexity and extent of glycosylation for recombinant human platelet-derived growth factor B chain (rhPDGF-B) expressed in yeast. In addition, liquid secondary ion mass spectrometry (LSIMS) and Edman degradation have been employed to verify the protein sequence. LSIMS of high-performance liquid chromatographically fractionated proteolytic digests confirmed the complete amino acid sequence predicted by the human PDGF-B gene structure. Potential glycopeptides (as indicated by a mass shift of 162 or 324 Da from the mass of a predicted cleavage product) were sequenced using tandem mass spectrometry and Edman degradation. Ultraviolet matrix laser desorption mass spectrometry of rhPDGF-B dimer was used to determine the molecular weight distribution for the intact recombinant glycoprotein. In addition to the presence of unmodified peptides, corresponding peptides bearing monomannosyl moieties were found on serine 26 and threonines 20, 63, 88, 90 and 101. Further, dimannosyl moieties were found on threonines 6 and 63. These data reveal the presence of O-linked glycosylation at sites which do not fortify the concept of a consensus sequence involving proline residues, but which strengthen the concept of secondary and tertiary structure requirements. The advantages of high-energy collisionally induced dissociation analysis of O-linked glycopeptides over conventional base elimination and borohydride reduction and other mass spectrometric techniques are presented for the first time.

Amino Acid Sequence↗

Combinatorial peptide libraries: robotic synthesis and analysis by nuclear magnetic resonance, mass spectrometry, tandem mass spectrometry, and high-performance capillary electrophoresis techniques.

Combinatorial peptide libraries are a new source of compounds from which a large number of pharmacological leads will emerge in the next few years. A large body of literature shows that this approach is of considerable interest in many areas of biological sciences for the search of enzyme substrates and inhibitors, of receptor agonists or antagonists, or of antigen sequences. Nevertheless, the analytical investigation of such complex mixtures as libraries which contain up to millions of individual molecules is still poorly documented. In this work, we present analytical solutions for their characterization. NMR and tandem mass spectrometry (MS/MS) can provide an in deep description of any type of combinatorial libraries, while MS and high-performance capillary electrophoresis can bring a rapid and overall information at the routine level, sufficient to ensure a first assessment of their composition. MS in the fast atom bombardment mode was used to describe the libraries O1X2X3X4X5 or O1X2X3X4 (Oi and Xi are fixed and random residue in position i, respectively). Advantage was taken of the high proton affinity of arginine and of its induction of charge remote fragmentation to interpret the MS spectra of whole libraries and neutral losses (MS/MS) in the model sublibraries ArgGlyX3X4 and NipValX3X4 (Nip,4-nitrophenylalanine). Two-dimensional NMR allowed the incorporation of the individual residues during synthesis to be tested in 24 sublibraries O1X2X3X4. While from the pharmacological point of view, impressive discoveries made with combinatorial peptide libraries have already been reported, our results show that they should be complemented by appropriate analytical tools, crucial for the proper characterization and exploitation of these libraries.

Amino Acid Sequence↗

Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry.

Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.

Atmospheric Pressure↗

Comparison of flow injection analysis electrospray mass spectrometry and tandem mass spectrometry and electrospray high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry for the determination of underivatized amino acids.

Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.

Amino Acids↗

Characterization of benzodiazepine "combinatorial" chemical libraries by on-line immunoaffinity extraction, coupled column HPLC-ion spray mass spectrometry-tandem mass spectrometry.

To characterize combinatorial chemical libraries of small drug compounds, an automated column switching system incorporating an immunoaffinity extraction (IAE) column and two reversed-phase HPLC columns was coupled to a triple-quadrupole mass spectrometer. A Protein G column and antibodies to benzodiazepines were used to screen library components. A pH change in the mobile phase eluted the benzodiazepine-antibody complexes onto a C-18 restricted access media (RAM) column, thereby separating the selected benzodiazepines from the antibody. In a final step, backflushing the RAM column eluted the benzodiazepines onto a C-8 analytical reversed-phase column for separation before detection and preliminary structural characterization using ion spray mass spectrometry (MS) and tandem mass spectrometry (MS/ MS). A known 19-component library and an unknown 20-component library were analyzed. Full-scan IAE/LC/ LC/MS and IAE/LC/LC/MS/MS chromatograms suggested the feasibility of this combination of techniques, although the antibodies used were not highly specific. Inspection of MS/MS spectra of components in the unknown library compared to the MS/MS spectrum of a known standard (chlordiazepoxide) identified a subclass of benzodiazepines. Productions of the known standard and an unknown benzodiazepine were successively captured and fragmented (MSn experiments) using an iontrap mass spectrometer off-line, which confirmed that the unknown was an analogue of chlordiazepoxide.

Benzodiazepines↗

Identification of the 'wrong' active pharmaceutical ingredient in a counterfeit Halfan drug product using accurate mass electrospray ionisation mass spectrometry, accurate mass tandem mass spectrometry and liquid chromatography/mass spectrometry.

Methodology is presented for identifying an unknown active (pharmaceutical) ingredient (AI) in a counterfeit drug product. A range of mass spectrometric techniques, i.e., accurate mass mass spectrometry, tandem mass spectrometry (MS/MS) and liquid chromatography/mass spectrometry (LC/MS), has been employed to determine the AI in a counterfeit Halfan suspension, an antimalarial drug. In particular, use of LockSpray accurate mass MS/MS allowed identification of parts of the molecule from fragments, hence limiting the number of possible elemental compositions for the nominal mass of 278 found for the AI in the counterfeit product. The analysis of the isotope pattern observed for the protonated molecule further reduced the number of possible elemental compositions. A literature search for readily commercially available compounds of molecular formula C(12)H(14)N(4)O(2)S suggested that the AI was either sulfamethazine or sulfisomidine. An LC/MS separation of those two compounds and reference MS/MS spectra obtained for sulfamethazine and sulfisomidine led to the conclusion that the AI in the counterfeit Halfan suspension is sulfamethazine, which is an antibacterial agent.

Chromatography, Liquid↗

[Screening of newborns for inborn errors of metabolism by tandem mass spectrometry].

Tandem mass spectrometry is an analytical method which is being implemented for neonatal screening. The method can determine the content of amino acids and acylcarnitines in neonatal screening samples in one integrated analysis. This allows detection of more than 20 inherited disorders of amino acid, fatty acid and organic acid metabolism. The aggregate incidence of these disorders is in the order of 1:4000. The principal disease which is detectable is medium-chain acyl-CoA dehydrogenase deficiency, which has an incidence of 1:10,000-1:20,000 in Northern Europe. Medium-chain acyl-CoA dehydrogenase deficiency puts the affected at risk of life-threatening metabolic crises, which are preventable if the condition has been diagnosed. Hence, the prognosis is excellent. The central theme for therapeutic management of medium-chain acyl-CoA dehydrogenase deficiency is carbohydrate supplementation, especially in situations of intercurrent illness. Tandem mass spectrometry screening will also enhance the present screening for phenylketonuria which employs a bacterial assay: the screening sample can be obtained 48-72 hours post partum, the false-positive rate will be reduced, and there will be no interference with antibiotics. Tandem mass spectrometry is being used in state-mandated screening panels in a few places and is being tested in pilot studies in many other places. A national prospective pilot project was launched on February 1, 2002 in Denmark. The project includes tandem mass spectrometry screening for galactosemia. In addition to neonatal screening, tandem mass spectrometry can be used for investigation of metabolic diseases, sudden unexpected death of infancy and shaken baby syndrome. Critical appraisal of tandem mass spectrometry will lead to improved health for infants affected by rare inherited disorders of metabolism.

Acyl-CoA Dehydrogenases↗

13C isotopomer analysis of glutamate by tandem mass spectrometry.

Tandem mass spectrometry allows a compound to be isolated from the rest of the sample and dissociated into smaller fragments. We show here that fragmentation of glutamate mass isotopomers yields additional mass spectral data that significantly improve the analysis of metabolic fluxes compared to full-scan mass spectrometry. In order to validate the technique, tandem and full-scan mass spectrometry were used along with (13)C NMR to analyze glutamate from rat hearts perfused with three substrate mixtures (5 mM glucose plus 5 mM [2-(13)C]acetate, 5 mM [1-(13)C]glucose plus 5 U/L insulin, and 5 mM glucose plus 1 mM [3-(13)C]pyruvate). Analysis by tandem mass spectrometry showed that the enriched substrate contributed 98 +/- 2, 53 +/- 2, and 84 +/- 7%, respectively, of acetyl-coenzyme A while the rate of anaplerotic substrate entry was 7 +/- 3, 25 +/- 8, and 16 +/- 8%. Similar results were obtained with (13)C NMR data, while values from full-scan data had higher error. We believe that this is the first use of tandem mass spectrometry to determine pathway flux using (13)C-enriched substrates. Although analysis of the citric acid cycle by NMR is simpler (and more intuitive), tandem mass spectrometry has the potential to combine high sensitivity with the high information yield previously available only by NMR.

Animals↗

Distinguishing and quantifying peptides and proteins containing D-amino acids by tandem mass spectrometry.

Tandem mass spectrometry (MS/MS) utilizing both electron capture dissociation (ECD) and collisionally activated dissociation (CAD) was used to develop a qualitative and quantitative analytical method for chiral analysis of individual amino acid residues in polypeptides. ECD produced a more distinct chiral recognition than CAD, which is attributed to the smaller degree of vibrational excitation in ECD. Several peptide and protein model systems were used in this study, including the smallest known protein, tryptophan cage, a lactoferrin peptide, and the biologically relevant opioid peptide, dermorphin. An adaptation of the kinetic method was used to quantify the degree of separation between fragmentation patterns of stereoisomeric peptides as a function of fragment ion abundances. The obtained calibration scale for relative abundances of d-amino acids in diastereomeric peptide mixtures was accurate to 1% for ECD and to 3-5% for CAD. It was found that separation and quantification of stereoisomers could be advantageously performed by nanoflow reversed-phase liquid chromatography, with the objective of on-line MS/MS limited to stereoisomer identification. This technique shows promise for the analysis of chiral substitution in peptides and proteins, broadening the application area for tandem mass spectrometry.

Amino Acid Sequence↗

Protein identification using nano liquid chromatography-tandem mass spectrometry.

Tandem mass spectrometry is an efficient technique for the identification of peptides on the basis of their fragmentation pattern (MS/MS scan). It can generate individual spectra for each peptide, thereby creating a powerful tool for protein identification on the basis of peptide characterization. This important advance in automatic data acquisition has allowed an efficient association between liquid chromatography and tandem mass spectrometry, and the use of nanocolumns and nanoelectrospray ionization has dramatically increased the efficiency of this method. Now large sets of peptides can be identified at a femtomole level. At the end of the process, batch processing of the MS/MS spectra produces peptide lists that identify purified proteins or protein mixtures with high confidence.

Chromatography, High Pressure Liquid↗

A suboptimal algorithm for de novo peptide sequencing via tandem mass spectrometry.

Tandem mass spectrometry has emerged to be one of the most powerful high-throughput techniques for protein identification. Tandem mass spectrometry selects and fragments peptides of interest into N-terminal ions and C-terminal ions, and it measures the mass/charge ratios of these ions. The de novo peptide sequencing problem is to derive the peptide sequences from given tandem mass spectral data of k ion peaks without searching against protein databases. By transforming the spectral data into a matrix spectrum graph G = (V, E), where |V| = O(k(2)) and |E| = O(k(3)), we give the first polynomial time suboptimal algorithm that finds all the suboptimal solutions (peptides) in O(p|E|) time, where p is the number of solutions. The algorithm has been implemented and tested on experimental data. The program is available at http://hto-c.usc.edu:8000/msms/menu/denovo.htm.

Algorithms↗

Structural analysis of choline phospholipids by fast atom bombardment mass spectrometry and tandem mass spectrometry.

The structures of intact choline phospholipids were determined by positive and negative ion mode fast atom bombardment mass spectrometry, tandem mass spectrometry, and B2/E and B/E constant linked scan mass spectrometry. The molecular weight of the choline lipid could be clearly determined by the appearance of [M + H]+ or [M + Na]+ in the positive ion mode and triplet ions, e.g., [M - 15]-, [M - 60]-, and [M - 86]-, in the negative ion mode. The structures of the triplet ions were assigned to [M - CH3]-, [M - HN(CH3)3]-, and [M - CH2 = CHN(CH3)3]-, respectively, by the MS/MS of each triplet ion, and the origin of the triplet ions was found as the matrix-ion adduct to the target molecule by using the B2/E linked scan technique. The polar group could be identified by the existence of ions indicating glycerophosphocholine and its cleavage products and by the presence of the triplet ions in the negative ion mode. Positional determination of the distribution of constituent fatty acyl groups was carried out by comparing the intensity of deacylated ions from positions 1 and 2 in the positive ion mode and of the ions produced by MS/MS of the triplet ions. From the mass number of the [RCOO]- ion which appeared in the negative ion mode, the molecular weight and degree of unsaturation of the fatty acyl group were determined. The position of double bond(s) in the acyl group was determined from the MS/MS of the [RCOO]- ion.

Lysophosphatidylcholines↗

An SVM scorer for more sensitive and reliable peptide identification via tandem mass spectrometry.

Tandem mass spectrometry (MS/MS) has become increasingly important and indispensable in high-throughput proteomics for identifying complex protein mixtures. Database searching is the standard method to accomplish this purpose. A key sub-routine, peptide identification, is used to generate a list of candidate peptides from a protein database according to an experimental MS/MS spectrum, and then validate these candidate peptides for protein identification. Although currently there are many algorithms for peptide identification, most of them either lack an effective validation module or only validate the first-ranked peptide, thus leading to a low identification reliability or sensitivity. This paper proposes a new algorithm, named pepReap, to overcome the above drawbacks. It consists of a two-layered scoring scheme based on machine learning. The first layer is a rough scoring function which uses some simple and heuristic factors to measure the degree of the matches between an experimental MS/MS spectrum and the candidate peptides; thus a ranked list of candidate peptides is generated at a relatively low computational cost. The second layer is a fine scoring function which re-ranks the candidate peptides generated in the first layer and determines which one among them is the true positive. The fine scoring function was designed based on support vector machines (SVMs) using more comprehensive factors, such as the correlations between ions, the mass matching errors of fragment and peptide ions, etc. Consequently, the SVM classifier serves as not only a scorer but also a validation module. Experimental comparison with the popular SEQUEST algorithm coupled with threshold validation criteria on a reported dataset demonstrates that the pepReap algorithm achieves higher performance in terms of identification sensitivity with comparable precision.

Algorithms↗

Structural elucidation of minor components of peptidyl antibiotic P168s (leucinostatins) by tandem mass spectrometry.

Tandem mass spectrometry with a four-sector type mass spectrometer was used to elucidate the structures of minor components of the peptidyl antibiotic P168s (leucinostatins). As N-terminal fragments, ions by B-type cleavage were dominant, while V-type cleavages were observed along with X, Y, and Z types as C-terminal ions. The V-type ions were predominant in the cleavages of the amino terminals of leucyl and hydroxyleucyl residues. The structures of several minor components could be deduced from the tandem mass spectra.

Amino Acid Sequence↗

Primary sequence information from intact proteins by electrospray ionization tandem mass spectrometry.

Tandem mass spectrometry has been used to obtain information related to portions of the primary sequence for an intact protein, bovine ribonuclease A. Multiply charged molecular ions, generated by electrospray ionization, were collisionally dissociated at low energies in a triple quadrupole mass spectrometer to yield singly and multiply charged fragment ions that can be assigned to the known sequence of the protein. Dissociation of the highly charged molecular ions resulted in pairs of complementary product ions. The higher order (gas-phase) protein structure affects the dissociation processes, as observed in comparisons of tandem mass spectra of the native and disulfide-reduced forms of ribonuclease A.

Amino Acid Sequence↗

A dynamic programming approach to de novo peptide sequencing via tandem mass spectrometry.

Tandem mass spectrometry fragments a large number of molecules of the same peptide sequence into charged molecules of prefix and suffix peptide subsequences and then measures mass/charge ratios of these ions. The de novo peptide sequencing problem is to reconstruct the peptide sequence from a given tandem mass spectral data of k ions. By implicitly transforming the spectral data into an NC-spectrum graph G (V, E) where /V/ = 2k + 2, we can solve this problem in O(/V//E/) time and O(/V/2) space using dynamic programming. For an ideal noise-free spectrum with only b- and y-ions, we improve the algorithm to O(/V/ + /E/) time and O(/V/) space. Our approach can be further used to discover a modified amino acid in O(/V//E/) time. The algorithms have been implemented and tested on experimental data.

Algorithms↗

Characterization of disulfide bond position in proteins and sequence analysis of cystine-bridged peptides by tandem mass spectrometry.

Tandem mass spectrometry employing high-energy, collisionally activated dissociation (CAD) is shown to be a useful method for sequencing through the cystine bridge of intermolecularly disulfide-bonded peptides. A characteristic triplet of intense fragment ions is observed corresponding to cleavage through and to either side of the disulfide bridge. These fragments define the masses of the linked peptides. Fragments due to peptide chain cleavage are also observed at lower abundance in the product-ion spectra and can be sufficient to sequence both of the disulfide-linked peptides without any prior knowledge of the peptide or protein sequence. Even in cases where the peptide sequence-related product-ion yields are poor, the intensities of the disulfide cleavage ions are usually sufficient to determine the molecular weights of the component cystine-bridged peptides. In this paper we demonstrate that the high-energy CAD tandem MS approach may be used to characterize disulfide-bonded peptides directly in complex enzymatic or chemical digests of native proteins. This obviates the need for individual purification of intermolecularly disulfide-linked peptides prior to analysis. The techniques are illustrated here for synthetic, inter- and intramolecularly disulfide-linked peptides and for human transforming growth factor-alpha (des-Val-Val-TGF-alpha), a compact protein containing 48 residues and three disulfides.

Amino Acid Sequence↗