PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Transducers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Comparison between a new acceleration transducer and a conventional force transducer in the evaluation of twitch responses.

An acceleration transducer elicits an output voltage proportional to the deformation of the piezo crystal, in accordance with the twitch responses of the applied fingers. The reliability of such a transducer was evaluated by comparing induced twitch responses with those from a force transducer applied on the contralateral arm of an individual during neuromuscular block with vecuronium. The results obtained from twitch responses with the acceleration transducer during neuromuscular block were almost identical to those obtained with the force transducer. Also, the twitch heights due to acceleration of the examined thumb correlated extremely well with the twitch height due to twitch tension with the force transducer. It is concluded that the acceleration transducer may be a useful and reliable device for monitoring neuromuscular block, although responses during tetanic stimulation such as tetanic fade cannot be determined by the transducer.

Adolescent↗

The balanced electromagnetic separation transducer a new bone conduction transducer.

Conventional bone conduction transducers, which are relatively large, suffer from poor performance at low frequencies. A new type of electro-dynamic transducer, the balanced electromagnetic separation transducer (BEST), was developed to improve the performance of the conventional transducers. By using a balanced suspension principle, the quadratic distortion forces, as well as the static forces between the vibrating parts, are principally counterbalanced. Both the distortion and the size of the transducer can therefore be considerably reduced. Moreover, the static and dynamic magnetic fluxes are separated, except in the air gap regions, giving a more efficient transducer. For example, in comparison with a conventional B71 transducer, a prototype of the BEST has: Lower total harmonic distortion (THD), by 20-25 dB, and improved sensitivity by 10-20 dB for 100 to 1000 Hz and by 2-10 dB for 1 to 10 kHz. From a clinical point of view, the BEST offers a chance to measure bone thresholds, at 250 and 500 Hz, which are reliable at hearing levels not possible before. For example, at 250 Hz the BEST has 23 dB higher sensitivity than the B71; the THD is improved from 61% (B71) to 3.3% (BEST) at 40 dB HL (ISO 389-3, 1994).

Audiometry, Pure-Tone↗

Comparative pressure measurements in the oesophagus by means of in situ tip-transducers and external transducer systems.

Basal gastro-oesophageal sphincter pressures and peak peristaltic pressure amplitudes in the oesophageal body 5 and 15 cm proximal to the gastro-oesophageal sphincter were measured with three different set ups in six healthy volunteers. The in situ tip-transducer measurements were compared to two different external pressure transducers in a perfused catheter system and to an external pressure transducer in a non-perfused catheter system. The in situ tip-transducer recorded higher sphincter pressures and peristaltic amplitudes than those recorded by the perfused and non-perfused systems (P less than 0.01). There was no difference between the pressures recorded by perfused systems in conjunction with the different external transducers. The perfused systems recorded sphincter pressures higher than those recorded by the non-perfused systems (P less than 0.02 and P less than 0.01), whereas the non-perfused system recorded higher peristaltic pressure amplitudes than those recorded by the perfused systems (P less 0.01 and P less than 0.01). The importance of the bend of the in situ tip-transducer was shown experimentally. It is concluded that the ideal system for recording oesophageal pressures is a perfused catheter set-up with minimal compliance. The probe with three side holes at the same level ensures registrations of the lowest occlusion pressure at the measuring point.

Adult↗

A comparison of sitting pressures on wheelchair cushions as measured by air cell transducers and miniature electronic transducers.

With increasing attention to cushion selection for patients subject to decubitus ulcers, greater efforts are being made to prescribe cushions based on individual need. Pressure measurements during sitting frequently are utilized as a clinical guide to the process of selection and fitting. To determine the relationship between pressure values recorded from different types of transducers, simultaneous measurements were made beneath the ischial tuberosities using a Scimedics air cell transducer on one side and a matrix of 5 Kulite electronic transducers on the other side of a subject while sitting on a series of 21 commercially available wheelchair cushions. Although these transducers are different in structure and function, statistically similar results were obtained. The air cell type of transducer appear to be more appropriate for routine clinical use, but caution is advised regarding interpretation of results in terms of absolute pressures due to the many variables involved -- these techniques are suitable primarily for comparative measurements to obtain the optimal seating support for a given patient.

Humans↗

The acceleration transducer--an assessment of its precision in comparison with a force displacement transducer.

A new and simple acceleration transducer (ACT)-based system of neuromuscular monitoring has recently been introduced. The precision of this transducer has been evaluated as compared to a conventional force displacement transducer (FDT) in the present study. Ten progressions of spontaneous recovery from atracurium-induced block with simultaneous measurements using the ACT on one hand and the FDT on the other were studied. Five individuals undergoing elective surgery in modified neurolept anaesthesia and one ICU-patient requiring prolonged neuromuscular blockade, sedated with pentobarbital, were included. Measurements were carried out on the latter patient on 5 consecutive days. Train-of-four (TOF) stimulation was used, readings were given in twitch heights (TH) (T1/control value), and when four responses were obtained in TOF-ratios (T4/T1). Linearity was achieved after logit-transformation and the values regressed on time for each progression of recovery. Analysis of variance was applied to the regressions for the TH and TOF-ratio readings of each transducer. No significant differences were found, either between variation due to differences between slopes or variation due to technical error between the two transducers. The study indicates that the ACT is equal to the FDT with regard to precision in clinical recordings on atracurium-relaxed individuals.

Aged↗

Ultrasonographic evaluation of equine tendons: a quantitative in vitro study of the effects of amplifier gain level, transducer-tilt, and transducer-displacement.

The objective of the in vitro experiments described in this paper was to quantify the effects of some instrumental variables on the quantitative evaluation, by means of first-order gray-level statistics, of ultrasonographic images of equine tendons. The experiments were done on three isolated equine superficial digital flexor tendons that were mounted in a frame and submerged in a waterbath. Sections with either normal tendon tissue, an acute lesion, or a chronic scar, were selected. In these sections, the following experiments were done: 1) a gradual increase of total amplifier gain output subdivided in 12 equal steps; 2) a transducer tilt plus or minus 3 degrees from perpendicular, with steps of 1 degree; and 3) a transducer displacement along, and perpendicular to, the tendon long axis, with 16 steps of 0.25 mm each. Transverse ultrasonographic images were collected, and in the regions of interest (ROI) first-order gray-level statistics were calculated to quantify the effects of each experiment. Some important observations were: 1) the total amplifier gain output has a substantial influence on the ultrasonographic image; for example, in the case of an acute lesion, a low gain setting results in an almost completely black image; whereas, with higher gain settings, a marked "filling in" effect on the lesion can be observed; 2) the relative effects of the tilting of the transducer are substantial in normal tendon tissue (18%) and chronic scar (12%); whereas, in the event of an acute lesion, the effects on the mean gray level are dramatic (40%); and 3) the relative effects of displacement of the transducer are small in normal tendon tissue, but on the other hand, the mean gray-level changes 7% in chronic scar, and even 20% in an acute lesion. In general, slight variations in scanner settings and transducer handling can have considerable effects on the gray levels of the ultrasonographic image. Furthermore, there is a strong indication that this quantitative method, as far as based exclusively on the first-order gray-level statistics, may be not discriminative enough to accurately assess the integrity of the tendon. Therefore, the value of a quantitative evaluation of the first-order gray-level statistics for the assessment of the integrity of the equine tendon is questionable.

Animals↗

Acoustic coupling from a focused transducer to a flat plate and back to the transducer.

An approximate solution for the acoustic coupling factor (the diffraction correction function) from a focused transducer to a flat plate and back to the transducer is provided. This function is useful for system calibrations where a pulse-echo system or transmit-receive system is used. Numerical solutions are provided for the important case where the flat plate is placed near the focal plane of the transducer. The solution for a flat disk transducer is obtained as a limiting case. Experimental evidence for a focused transducer is provided.

Acoustic Stimulation↗

Partially coherent transducers: the random phase transducer approach.

Ultrasound speckle is a consequence of the stochastic nature of the reflectivity of scattering media (e.g., biological tissue) and of the coherent nature of piezoelectric transducers. This speckle noise can be reduced by the use of incoherent processing techniques (e.g., spatial compounding, incoherent summation, random phase and phase insensitive transducers). We present a unified framework that explains the limitations of incoherent processing in terms of the information grain theory. This theory predicts the gains in SNR as well as the losses in directivity. We also present the random phase transducer approach to incoherence to total coherence. We present applications to speckle reduction, detection of specular reflectors, attenuation estimation and ultrasound imaging. We show that totally incoherent transducers completely remove diffraction effects. They might be used in attenuation estimation, in which case, correction for diffraction is no longer required, in order to obtain unbiased estimates. Partially coherent transducers might also be useful in imaging to reduce speckle noise.

Humans↗

Comparative study of a 15-MHz focused ultrasonic transducer and a 15-MHz unfocused ultrasonic transducer for clinical in-vivo skin-thickness measurements in human subjects.

A commercial focused 15-MHz immersion ultrasonic transducer and a commercial unfocused 15-MHz thickness-gaging ultrasonic transducer were evaluated for invivo skin-thickness measurements in humans. The unfocused transducer produced thicker skin measurements than did the focused transducer but both measurements were generally within previously reported ranges. The differences in the determined thicknesses may have been a result of the uneven nature of the dermissubcutaneous tissue interface and the ability of the focused transducer to better follow this interface.

Arm↗

Ex vivo selection for oncoretrovirally transduced green fluorescent protein-expressing CD34-enriched cells increases short-term engraftment of transduced cells in baboons.

In an effort to improve hematopoietic stem cell gene transfer rates using gibbon ape leukemia virus (GALV)-pseudotype retroviral vectors in baboons, we have studied preselection of transduced green fluorescent protein (GFP)-expressing CD34-enriched marrow cells. Three animals were transplanted with GFP-selected (GS) CD34-enriched marrow. To ensure engraftment, preselected GFP-positive cells were infused together with unselected neo-transduced cells. After transduction on fibronectin, cells were cultured for an additional 2 days to allow for expression of GFP. GFP-expressing cells were enriched by fluorescence-activated cell sorting and infused together with cells from the unselected fractions after myeloablative irradiation of the recipient. Three other animals were transplanted with GFP-transduced CD34-enriched cells without prior GFP selection (GU). At 4 weeks after transplant, the percentage of GFP-expressing white blood cells was significantly higher in the GS group (6.6%) than in the GU group (1.3%) (p < 0.002). The higher gene transfer levels in the animals transplanted with GS cells gradually declined, and by day 100 after transplant, gene transfer levels were similar in both groups. PCR analysis performed on genomic DNA isolated from peripheral blood cells demonstrated that the decline in GFP-positive cells was due to the loss of gene-marked cells and not due to loss of expression. These results show that transplantation of CD34-positive marrow cells selected for GFP-positive cells after transduction provides high levels of transduced granulocytes in the short term. However, using this experimental design with concomitant infusion of unselected cells and the use of oncoretroviral vectors, preenrichment of vector-expressing, transduced CD34-enriched cells does not improve long-term persistence and expression.

Animals↗

The measurement of tremor using a velocity transducer: comparison to simultaneous recordings using transducers of displacement, acceleration and muscle activity.

Precise kinematic measurements of tremor have historically been obtained using accelerometers. However, current technology permits precise measurements in velocity and displacement. The primary advantage of velocity recording is that only one step of integration or differentiation is required for either displacement or acceleration. A method is presented of measuring finger tremor using a laser system that transduces velocity precisely. Measurements of postural finger tremor thus obtained were compared to those simultaneously obtained from a laser system that transduces displacement, from an accelerometer and from surface electromyography (EMG) of the extensor digitorum communis. A range of amplitude and frequency content was obtained by testing control subjects and subjects with Parkinson's disease. The velocity transducer showed excellent correspondence of amplitude and frequency measurement with the displacement transducer. Measures of absolute and relative amplitude correlated well (r > or = 0.96 in amplitude measures in displacement, velocity and acceleration), and high coherence was found throughout the frequency range of interest. Measurements by the accelerometer generally showed poorer correspondence with those of the other instruments. EMG measurements showed good correspondence in some trials but poorer correspondence in others, attributed to the low level of muscle activity required in the task. Precise kinematic measurements appear to be highly sensitive to neuromotor impairment.

Acceleration↗

Assessment of neuromuscular transmission by the evoked acceleration response. An evaluation of the accuracy of the acceleration transducer in comparison with a force displacement transducer.

This paper presents preliminary observations on an acceleration-responsive transducer designed to monitor neuromuscular transmission. Simultaneously evoked acceleration and tension responses of the adductor pollicis muscles were studied. Registrations were obtained during recovery from atracurium-induced block in 29 individuals in neurolept II anaesthesia (Group I) and in 4 ICU patients (Group II) sedated with pentobarbital or midazolam. Regression analysis of 1567 train-of-four (TOF) registrations, in regard to TOF-ratio (T4/T1) and first twitch ratio (T1/T0), demonstrated regression coefficients (b) and correlation coefficients (r) in the range 0.91-1.06 and 0.89-0.98, respectively. During 1 Hz single twitch stimulation and post-tetanic count stimulation, b and r were in the range 0.85-1.03 and 0.77-0.90, respectively. Following administration of edrophonium (n = 6, Group I) a deviation of T1/T0 regression values was observed in four individuals, i.e. 0.48 (b) and 0.56 (r). This investigation proved a good level of accuracy of the acceleration transducer compared to the force displacement transducer during spontaneous and neostigmine-induced recovery from atracurium block. The acceleration transducer-based system does not require a rigid suspension and seems to have a good monitoring potential in clinical assessment of neuromuscular transmission.

Adult↗

Evaluation of pulse oximetry in anaesthetised foals using multiple combinations of transducer type and transducer attachment site.

A commercially available pulse oximeter was evaluated in anaesthetised foals to determine its accuracy for estimating arterial haemoglobin saturation (SaO2). Five different transducer/transducer attachment site (TTAS) combinations were evaluated; 1-3) a fingertip transmission transducer attached to the foal's ear, lip and tongue, 4) an adhesive transmission transducer positioned on the foal's ear and 5) a forehead reflectance transducer placed on the ventral aspect of the foal's tail-base. Eight normal, Quarter Horse foals (age 5-10 days) were studied while under general anaesthesia. Alterations in arterial carbon dioxide tension (PaCO2) were produced by changing the level of ventilation. At each level of ventilation, alterations of arterial haemoglobin saturation (SaO2) were produced by varying the inspired fraction of oxygen (FIO2). At each level of ventilation and each level of FIO2, arterial blood samples were obtained for blood gas analysis while pulse oximeter readings were recorded simultaneously for each TTAS combination. Arterial blood oxygen saturation (SaO2) was calculated from arterial blood gas values and the equine blood oxygen dissociation curve. Pulse oximeter readings from each TTAS combination were compared with SaO2 values with linear regression analyses. Bias and precision values were determined and the sensitivity and specificity of each TTAS combination for detecting desaturation (SaO2 < 90%) were determined. Linear regression analyses indicated significant (P < 0.05) linear correlation between oxygen saturation determined by pulse oximeter (SpO2) and SaO2 for each of the 5 TTAS combinations. The combinations TTAS-1, TTAS-3 and TTAS-4 tended slightly to underestimate SaO2 at high SaO2 ranges, but overestimated SaO2 at low ranges of SaO2. Combination TTAS-2 overestimated SaO2 over all ranges of SaO2. Combination TTAS-5 consistently underestimated SaO2 at all ranges of SaO2. In general, accuracy and precision of each TTAS combination decreased at lower SaO2 ranges. All TTAS combinations, except TTAS-2 and TTAS-4, had good sensitivity for detecting SaO2 less than 90%. All TTAS combinations except TTAS-5 demonstrated good specificity. We concluded that pulse oximetry appears to be a valuable method for assessing SaO2 and detecting desaturation in anaesthetised foals. Clinicians should be aware that the type of transducer used and the anatomical site to which it is attached can have marked effects on the accuracy of pulse oximetry; and that different TTAS combinations may behave differently over various ranges of SaO2.

Anesthesia↗

A theoretical model of acoustoelectric transducer with a nonuniform distribution of piezoelectric coefficient: application to transducer optimization.

A general equation is derived that describes the behavior of a piezoelectric transducer with a nonuniform distribution of piezoelectric coefficient within its bulk, when submitted to an arbitrary distribution of acoustic pressure. Based on this equation, an expression for the receiving transfer function of the transducer is calculated. The results demonstrate the dependence of the transfer function on the distribution of piezoelectric coefficient, and that it is possible to benefit from a nonuniform distribution to optimize the transfer function. The general equation also describes the influence of the external electric circuit loading the transducer, which leads to another independent means of optimizing the transfer function. The proposed model combines effects of piezoelectric material characteristics, acoustic backing, and electric loading, without resorting to Mason or other equivalent circuits for the transducer.

Models, Theoretical↗

Induction of antitumor immunity by interleukin-2 gene-transduced mouse mammary tumor cells versus transduced mammary stromal fibroblasts.

BACKGROUND: Tumor cell-targeted cytokine gene transfer has been used to generate tumor cell vaccines, but this approach is limited by the need to establish and implant live tumor cells. PURPOSE: The purpose of this study was to determine if stromal fibroblasts could be used as an alternative vehicle for delivery of the cytokine interleukin-2 (IL-2) into the tumor microenvironment. We attempted to establish the feasibility of (a) genetic immunotherapy in a mammary tumor system and (b) engineering stromal fibroblasts as well as tumor cells. We compared the effects of tumor cell-mediated and stromal fibroblast-mediated local IL-2 expression on the generation of antitumor immune responses. METHODS: Retroviral vectors containing a human IL-2 gene were used to transduce a mouse mammary tumor line, 4TO7, and an immortalized but nontumorigenic fibroblast line established from syngeneic mammary fatpads. Expression of the IL-2 gene in transduced cells was determined by measuring IL-2 secretion, by RNA-polymerase chain reaction, and by immunochemistry. Groups of 5-12 BALB/c mice were injected with either 4TO7 cells or various doses of IL-2-secreting 4TO7 cells (4TO7-IL-2); tumor growth was monitored. To test whether local IL-2 expression by transduced cells could influence the growth of unmodified tumor cells, we determined tumor development in groups of mice treated with 4TO7 cells co-injected with either 4TO7-IL-2 cells or IL-2-secreting fibroblasts. RESULTS: 4TO7-IL-2 cells induced active immunity able to reject the immunizing tumor and to resist challenge with parental 4TO7 cells on the contralateral side. Mice pretreated with 4TO7-IL-2 were significantly protected compared with untreated control animals or mice pretreated with irradiated 4TO7 cells. The immunity induced by 4TO7-IL-2 cells did not protect against challenge with another subline, 4T1, which was derived from the same spontaneously arising mammary tumor as 4TO7. Co-injection of 4TO7 cells with 4TO7-IL-2 cells reduced tumorigenicity, whereas co-injection of 4TO7 cells with IL-2 secreting fibroblasts did not. CONCLUSION: Our results suggest that induction of anti-tumor immune response by local IL-2 production is most effective when the helper cytokine is secreted by the tumor cell. IMPLICATION: Our studies caution against the use of IL-2 gene-transduced syngeneic stromal cells as an alternative strategy of gene therapy for cancer. However, they may allow study of the mechanisms of tumor antigen recognition and the possible involvement of co-stimulatory signals for effective tumor vaccination by gene-modified cells.

Animals↗

Appearance of transducing particles and the fate of host DNA after infection of Salmonella typhimurium with P22-mutants with increased transducing ability (HT-mutants).

The kinetics of production of transducing particles for different bacterial markers were followed by premature lysis of Salmonella typhimurium cells infected with P22 phages. The were compared for cells infected with wild type phage or with HT-mutants which show increased transduction frequencies. Measuring the sedimentation velocity of bacterial DNA of cells infected with wild type or HT-phages, it was shown that: a) there is no cutting of DNA at random; b) original fragments necessary for packaging host DNA into transducing particles cannot be smaller than 10 phage-genome lengths; c) cutting of transducing fragments leads immediately to the right length; d) there is no loss of precipitable DNA due to phage infection.

DNA, Bacterial↗

Retrovirus-mediated enzymatic correction of Tay-Sachs defect in transduced and non-transduced cells.

Tay-Sachs disease is a severe neurodegenerative disorder due to mutations in the HEXA gene coding for the alpha-chain of the alpha-beta heterodimeric lysosomal enzyme beta-hexosaminidase A (HexA). Because no treatment is available for this disease, we have investigated the possibility of enzymatic correction of HexA-deficient cells by HEXA gene transfer. Human HEXA cDNA was subcloned into a retroviral plasmid generating to G.HEXA vector. The best Psi-CRIP producer clone of G.HEXA retroviral particles was isolated, and murine HexA-deficient fibroblasts derived from hexa -/- mice were transduced with the G.HEXA vector. Transduced cells overexpressed the alpha-chain, resulting in the synthesis of interspecific HexA (human alpha-chain/murine beta-chain) and in a total correction of HexA deficiency. The alpha-chain was secreted in the culture medium and taken up by HexA-deficient cells via mannose-6-phosphate receptor binding, allowing for the restoration of intracellular HexA activity in non-transduced cells.

3T3 Cells↗

Transducers in medical ultrasound. Part 4: Transducer safety.

Transducer safety encompasses a wide spectrum of topics. It may range from mechanical construction reliability to biological effects created by ultrasound radiation. In this Paper the electrical and acoustical safety aspects are summarized and initial experience with sterilization of echocardiographic transducers for peroperative cardiac scanning is mentioned.

Echocardiography↗