PubMed HealthSearch

SEARCH · PubMed Health

Results for “accelerometers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

11 recordsLinked to original sources

Proteomic Signatures Related to Physical Activity Are Associated with Risks of Future Disease.

PURPOSE: Physical activity (PA) can lower the risk of developing chronic diseases. However, few studies have examined the proteomic signatures linked to PA, and the role of these signatures in the connection between PA levels and future disease risk remains unclear. This study aimed to investigate whether proteomic signatures indicative of PA are associated with the risk of developing common chronic diseases and to explore their role as statistical links in the relationship between PA levels and disease development. METHODS: We used data from a subcohort of UK Biobank participants. PA intensity data were collected from accelerometers worn by each participant. Plasma proteomics results were obtained through Olink analysis. The risks of developing each primary chronic disease were evaluated for types of PA and their associated proteomic signatures, adjusting for age, sex, ethnicity, socioeconomic status, lifestyle factors, and key measurement time-lag covariates. RESULTS: Based on the UK Biobank, we identified significant differences among the proteomic signatures of accelerometer-measured light PA, moderate-to-vigorous PA, and total PA. The main enriched pathways of these proteomic signatures included cell adhesion, cell migration, and immune response. Higher levels of accelerometer-measured PA and their associated proteomic signatures correlated with a lower risk of developing cardiometabolic disorders, cancers, psychological or neurological disorders, and respiratory diseases. CONCLUSIONS: Our findings show that PA and PA-related proteomic signatures are statistically associated with lower risks of chronic diseases. Further analyses identified proteins that were correlated with both PA and disease risk. These results need to be confirmed through longitudinal studies involving diverse populations.

Humans

Quantification of muscle tremor of Huntington's disease patients and their offspring in an early detection study.

Accelerometer measurements of muscle tremor yielded significant findings for both Huntington's disease (HD) patients and their genetically at risk offspring. Although affected individuals are usually characterized by gross involuntary muscle movements, alterations in minute muscle tremor were also found in our sample of ten HD patients. Irregularities in tremor patterns were intensified with increased time since onset of the disorder and in addition reflected the effects of drug therapy for those on medication. The use of accelerometer measurements of muscle tremor may therefore, prove to be useful in evaluating new medications for affected individuals. For high risk immediate family members currently there is no safe and reliable method to identify, prior to clinical onset, any among them who will develop HD. Aberrant muscle tremor patterns resembling that shown by HD patients were found in one-third of a sample of 15 genetically at risk offspring. In the event an effective method of treatment is developed, early recognition of HD gene carriers by accelerometer tremor measurement could result in control of the disorder prior to substantial neurological damage.

Adult

Physical Activity and Cardiovascular Outcomes in Phenotype-Negative Cardiomyopathy Variant Carriers.

IMPORTANCE: Exercise may lead to disease progression and higher risk of sudden death in individuals with genetic cardiomyopathies, but the effects of exercise among individuals carrying a cardiomyopathy-associated variant without clinical manifestations (G+P-) are unclear. OBJECTIVE: To examine whether the effects of moderate to vigorous physical activity (MVPA) on cardiovascular (CV) outcomes, cardiac structure and function, and risk of developing overt cardiomyopathy and malignant ventricular arrhythmias (VAs) vary by G+P- status. DESIGN, SETTING, AND PARTICIPANTS: UK Biobank participants with whole-genome sequencing providing 1 week of accelerometer-based physical activity data and without prevalent heart failure (HF), atrial fibrillation (AF), cardiomyopathy, VAs, or implantable cardioverter-defibrillators were included in this cohort study. The study was conducted at 22 assessment centers throughout the UK from February 2013 to December 2015 with a median follow-up of 8 years. Data were analyzed from March 2024 to June 2025. EXPOSURE: Accelerometer-measured MVPA (minutes/week). MAIN OUTCOMES AND MEASURES: Associations were analyzed between MVPA volume and future incidence of adverse CV outcomes (AF, HF, myocardial infarction [MI], and stroke), cardiac magnetic resonance (CMR)-based measures of cardiac remodeling, and surrogates for clinical cardiomyopathy onset (cardiomyopathy and VA). Associations were compared between G+P- carriers and noncarriers. RESULTS: Among 84 699 individuals (mean [SD] age, 62 [8] years; 48 353 [57%] women; 3979 G+P- carriers), greater MVPA was associated with a lower risk of adverse CV outcomes over a median (IQR) 8.0 (7.5-8.5) years, irrespective of genotype. In multivariable models, higher MVPA was broadly associated with lower risk of incident CV disease in G+P- carriers (hazard ratio [HR] at optimal MVPA level vs zero [95% CI], AF: 0.68 [0.58-0.79]; HF: 0.58 [0.47-0.71]; MI: 0.49, [0.24-1.00]; stroke: 0.35 [0.12-0.99]). For G+P- carriers, MVPA in the range of 100 to 400 minutes per week was generally associated with lowest risk. Among individuals with CMR imaging, MVPA was associated with a similar pattern and extent of cardiac remodeling (eg, left ventricular dilation and left ventricular hypertrophy) in G+P- carriers vs noncarriers. Among G+P- carriers, higher MVPA was associated with lower risk of incident cardiomyopathy (HR at optimal MVPA vs 0, 0.03; 95% CI, 0.00-0.98) with no increase in risk of VA (eg, HR at 400 minutes of MVPA vs 0, 0.98; 95% CI, 0.83-1.14). Findings were generally consistent across variants associated with dilated cardiomyopathy, hypertrophic cardiomyopathy, or arrhythmogenic right ventricular cardiomyopathy, although precision of estimates for arrhythmogenic right ventricular cardiomyopathy were limited. CONCLUSIONS AND RELEVANCE: In this cohort study, MVPA within the general range of guideline-based recommendations was associated with lower risk of adverse CV outcomes and similar degrees of cardiac remodeling for G+P- carriers compared to noncarriers. Findings support the appropriateness of guideline-based MVPA recommendations for G+P- carriers.

Humans

Associations Between Health-Related Physical Fitness and Accelerometry-Based Energy Expenditure in Physiotherapy Workers.

BACKGROUND AND PURPOSE: Although it has been assumed that higher physical activity (PA) levels will contribute to better physical fitness (PF) performance, the interplay between these two has yet to be investigated. Moreover, the majority of studies have been presented in children and adolescents, and older adults, while little is known about the correlation in the adult working population of physiotherapists. Therefore, the main purpose of the study was to examine associations between objectively measured PA and health-related PF. METHODS: We recruited 50 physiotherapists (72.6% women) from several public and private settings in the city of Zagreb. The SenseWearArmbandPro3 (SWA), a triaxial accelerometer placed on the nondominant hand for 7 consecutive days, was used to capture total energy expenditure (TEE) and active EE (AEE). Cardiorespiratory fitness included the Harvard step test, and muscular fitness was composed of sit-ups in 60&#xa0;sec and the Handgrip strength. Flexibility was evaluated using the Toe-touch test. RESULTS: TEE and AEE were moderately and positively correlated with the Harvard step test (r&#xa0;=&#xa0;0.65 and 0.62, p&#xa0;<&#xa0;0.001), sit-ups (r&#xa0;=&#xa0;0.70 and 0.59, p&#xa0;<&#xa0;0.001), and the Handgrip strength test (r&#xa0;=&#xa0;0.74 and 0.64, p&#xa0;<&#xa0;0.001). No significant correlation with the Toe-touch test was observed (r&#xa0;=&#xa0;-0.25 and -0.19, p&#xa0;>&#xa0;0.05). When models were adjusted for age, weaker, but significant positive correlations remained. DISCUSSION: The findings suggest that both cardiorespiratory and muscular fitness are positively associated with PA, whereas no statistically significant association with flexibility was detected. Thus, it is not surprising that we obtained moderate to almost strong correlations between TEE and AEE with cardiorespiratory and muscular fitness. CONCLUSIONS: In physiotherapists, TEE and AEE yield moderate correlations with health-related PF, especially for cardiorespiratory and muscular fitness.

Humans

Huntington's disease: clinical and chemical effects of choline administration.

Choline (Ch) administration sequentially increases blood Ch, brain Ch, and brain acetylcholine (ACh) levels in the rat and might be useful in Huntington's disease, a brain disorder thought to be associated with deficient cholinergic tone. Ten patients with Huntington's disease took Ch orally (8 to 20 gm per day) after the extent of their disabilities had been documented by clinical examination, movies, and combined electromyogram-accelerometer recordings. Choline levels in blood and cerebrospinal fluid increased markedly during treatment with Ch, affirming that oral Ch administration increases the amount of ACh precursor delivered to the brain. Although some of the patients exhibited transient improvement in speech, balance, and gait, treatment with Ch failed to bring about consistent or lasting improvement in any of the subjects.

Acetylcholine

[Animal experiments on the biomechanical vibration behaviour of the bulbus (author's transl)].

Mechanical vibration may have a detrimental effect on visual performance. This particularly seems to be the case if the natural frequency of the bulbus is excited. Experiments with animals were made with the aim of calculating the biomechanic transmission of vibration between the cranium and bulbus. Postmortem experiments using pig crania have shown that in vivo application of the method of sewing miniature accelerometers onto the cornea may be possible. Our experiments with monkeys gave typical resonance curves for the transmission of vibration of the bulbi with maxima between 25 and 31.5 Hz. Transferability of the results to the human eye is discussed.

Animals

The vibration stimulus. Effects of viscous-elastic resistance of skin on the amplitude of vibrations.

Accurate measurements of the vibration amplitude were Fig. 7. Reproducibility of double determinations of the vibratory perception threshold (log V2) in normal persons and uraemic patients. PH=pulp, big toe; MM=medial malleolus. Axes show read values in volts transformed into a log V2 scale. Full and strippled lines indicate mean and 95% confidence limits of expected variation (ref. Table II). Made possible by a piezo-electric transducer (accelerometer). With constant voltage to the vibrator slight compression of the tactor against the skin produced an increase in amplitude, similar to that seen with compression against a rubber diaphragm. Further compression had a variable effect on the vibration amplitude, depending on the nature of the underlying tissue (bone, soft tissue). An exact calibration of the vibration stimulus strength therefore appears impossible, and a comparison of the acuity of vibratory perception is invalidated by the different viscous-elastic protion amplitude and the square of the voltage, as seen for vibrations in air, was also demonstrable between independent measurements of the vibratory perception threshold (VPT) in the two terms. The intra- and interindividual variations in terms of the amplitude and the square of the voltage were of the same order. On a logarithmic scale the reproducibility of VPT was independent of the threshold stimulus strength.

Elasticity

Virtual reality physical education and adolescents' exercise interest and physical fitness: An explanatory sequential mixed-methods randomized trial with exploratory pathway analysis.

Traditional physical education (PE) faces declining student interest and limited fitness gains. Virtual reality (VR) offers immersive, gamified experiences, but evidence regarding its effectiveness and explanatory pathways remains limited. This explanatory sequential mixed-methods randomized trial assigned 360 adolescents (aged 13-16) from three middle schools to either VR-supported PE (n&#xa0;=&#xa0;180) or conventional PE (n&#xa0;=&#xa0;180) for 12&#xa0;weeks, with a 4-week follow-up. Outcomes included exercise interest (validated scale), physical fitness (coordination via MABC-2, cardiorespiratory endurance via the 20-m shuttle run, explosive power via the standing long jump, and speed via the 10-m sprint), and accelerometer-measured physical activity. The qualitative component involved 38 unique students: 32 completed individual semi-structured interviews, and six additional students participated only in focus groups. Three-level linear mixed-effects models and exploratory structural equation modeling were used. The VR group showed significantly greater improvements in exercise interest (d&#xa0;=&#xa0;0.78), coordination (d&#xa0;=&#xa0;0.62), cardiorespiratory endurance (d&#xa0;=&#xa0;0.55), and speed (d&#xa0;=&#xa0;0.48) than the control group (all p&#xa0;<&#xa0;0.001), but not in explosive power (d&#xa0;=&#xa0;0.12, p&#xa0;=&#xa0;0.148). Effects were partially retained at follow-up (interest d&#xa0;=&#xa0;0.65, coordination d&#xa0;=&#xa0;0.48, endurance d&#xa0;=&#xa0;0.42, and speed d&#xa0;=&#xa0;0.30), a pattern not fully consistent with a purely novelty-driven explanation. Exploratory mediation identified exercise interest as a statistically compatible explanatory pathway (indirect effect&#xa0;=&#xa0;0.34, 95% CI [0.22, 0.46]), although the timing of measurement precludes causal interpretation. Qualitative findings contextualized these results by highlighting immersion, feedback, self-efficacy, and perceived transfer. VR-supported PE may enhance adolescents' exercise interest and selected fitness dimensions, but its limited effect on explosive power and possible novelty contribution indicate that it should complement, rather than replace, conventional PE. Longer-term studies are needed.

Humans

Reliability of resting heart rate measurements in atrial fibrillation.

BACKGROUND: Heart rate (HR) control in atrial fibrillation (AF) is commonly guided by resting HR measurements, usually with 12&#x2011;lead ECG or in-office pulse palpation. OBJECTIVES: We aimed to assess the reliability of resting HR measurements in AF patients with long-term ambulatory ECG and activity monitoring. METHODS: We included patients who had recorded a full-disclosure ambulatory ECG with a mobile cardiac telemetry device equipped with an accelerometer (PocketECG, MEDICALgorithmics, Poland), with at least 95% AF. Resting HR samples (&#x2264;20 per individual/day) were collected as 10-s daytime (8&#xa0;am to 8&#xa0;pm) measurements after &#x2265;10&#xa0;min of rest. These samples were compared to each individual's mean daytime resting HR. RESULTS: In 832 patients (median age 77 (interquartile range (IQR) 69-83) years, 42% women) with a median registration duration of 13&#xa0;days (IQR 7-22), the population mean daytime resting HR was 85 (&#xb1;15) beats per minute (bpm). A single resting HR differed from the mean daytime resting HR by a mean of &#xb1;10.4% (IQR 3.6-14.4%). When the mean daytime resting HR was &#x2265;110&#xa0;bpm, 29% of resting HR samples were&#xa0;<&#xa0;110&#xa0;bpm, and when the mean daytime resting HR was 80-109&#xa0;bpm,11% of samples were&#xa0;&#x2265;&#xa0;110&#xa0;bpm. Resting HR measurement variability decreased to 5.3% (IQR 1.9-7.5%) when four resting HR samples were averaged. CONCLUSION: In patients with AF, a single resting HR measurement often differs substantially from the mean daytime resting HR. When a precise measurement is clinically relevant, repeated resting HR sampling or ambulatory monitoring can address this measurement imprecision.

Humans

Teacher- Versus Video-Delivered Classroom Activity Breaks and Student Physical Activity: The PAAC-3 Trial.

BACKGROUND: Classroom activity breaks may increase moderate-to-vigorous physical activity (MVPA); however, few studies have compared teacher and video-delivered approaches under real-world conditions. METHODS: In this cluster randomized trial, 11 elementary schools were assigned to teacher-delivered (PAAC-T; 5 schools, 192 students) or video-delivered (PAAC-V; 6 schools, 276 students) classroom activity breaks across one academic year. Teachers were trained to deliver two 10-min breaks daily. Intervention delivery was tracked via a web-based platform, and classroom MVPA was assessed using accelerometers at baseline and follow-up. RESULTS: Implementation fidelity was low and highly variable, but comparable between PAAC-T (42.3&#x2009;&#xb1;&#x2009;57.1 activity breaks/teacher/year) and PAAC-V (39.2&#x2009;&#xb1;&#x2009;33.9; p&#x2009;=&#x2009;0.96), with teachers delivering &#x223c;50% of the intended daily activity. Classroom MVPA increased significantly in both groups (PAAC-T: 9.8&#x2009;&#xb1;&#x2009;15.9; PAAC-V: 9.1&#x2009;&#xb1;&#x2009;15.3&#x2009;min/day; p&#x2009;<&#x2009;0.001), with no intervention arm-by-time interaction (p&#x2009;=&#x2009;0.43). IMPLICATIONS FOR SCHOOL HEALTH POLICY, PRACTICE, AND EQUITY: Classroom physical activity breaks may increase student MVPA, but effectiveness in elementary schools appears to depend on implementation fidelity, administrative support, and equitable system-level infrastructure. CONCLUSIONS: Modest increases in classroom MVPA were observed across both delivery formats, although low and variable implementation fidelity limited conclusions regarding effectiveness and highlighted the need for stronger implementation supports. TRIAL REGISTRATION: NCT03493139.

Humans

Lifestyle, anthropometric factors and clinically significant prostate cancer diagnosis in men with suspected prostate cancer.

OBJECTIVE: Lifestyle and anthropometric factors may influence prostate cancer (PCa) risk, yet evidence remains inconclusive. This study reports the associations between lifestyle and anthropometric factors and clinically significant PCa (csPCa; ISUP grade > 1) among men with clinical suspicion of PCa. MATERIALS AND METHODS: In this registered (NCT06116851), single-institution, prospective cohort trial, men referred for PCa diagnostics due to elevated prostate-specific antigen or abnormal digital rectal examination were included. Subjects underwent prostate diagnostics and completed detailed surveys of lifestyle, medical and family history. Physical activity was measured using a triaxial accelerometer. Anthropometric assessments included body mass index, waist circumference and magnetic resonance imaging-based body composition analyses. RESULTS: Among 298 included men, 143 (48%) were diagnosed with csPCa. In multivariate logistic regression, higher physical activity, measured by step count (odds ratio [OR]: 0.91, 95% confidence interval [CI]: 0.82-0.99) and active smoking compared to never-smokers (OR: 0.38, 95% CI: 0.14-0.96) were inversely associated with detection of csPCa. Higher prostate-specific antigen density was associated with increased risk (OR: 1.78, 95% CI: 1.39-2.35). Body composition was not associated with csPCa. Study strengths include comprehensive data collection. Primary limitation is partial reliance on self-reported data. CONCLUSIONS: Higher measured physical activity was inversely associated with detection of csPCa in men with suspicion of PCa. Active smoking also showed an inverse association. Both findings merit further investigation.

Aged