PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “antimicrobial susceptibility testing (AST)”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Antimicrobial susceptibility testing (AST): a review of changing trends, quality control guidelines, test accuracy, and recommendation for the testing of beta-lactam drugs.

The review that follows presents the changing trends in antimicrobial susceptibility testing observed from the author's clinical laboratory experience and the proficiency testing surveys of the College of American Pathologists (CAP). The CAP Microbiology Surveys show a clear trend toward standardized test methods of the National Committee for Clinical Laboratory Standard (NCCLS) and greater compliance with specified methods' technical steps. This has favorably influenced the laboratory performance on proficiency challenges where a 3-5% improvement has been noted over the last 5 years for the disk tests (overall acceptable rate of 95.2% in 1981). A concurrent increase in dilution test use, mainly broth microdilution methods, has resulted in greater than 25% of larger hospital laboratories reporting results as MICs (overall acceptable or good performance = 98%). Automated systems use also continues to increase, with user performance being monitored at an acceptable level. Quality control frequency may be reduced to once weekly without compromising test accuracy or patient care, but only after adequate daily or concurrent QC performance has been documented. Most methods continue to have problems in testing enterococci, methicillin-resistant staphylococci, and the class-disk concept appears to be less applicable. Recommendations are made for the testing of the newer semisynthetic penicillins and cephalosporins based on their spectrum comparability and cross-resistance studies with bacteria possessing known susceptibility or resistance mechanisms. The concept of "spectrum-class" is introduced with peer drugs within classes. The general trends and quality of antimicrobial susceptibility tests seem outstanding and point toward continued excellent intra- and interlaboratory reproducibility at the national level, primarily due to the efforts of the inspection and accreditation agencies, CAP, CDC, and other concerned professional groups.

Anti-Bacterial Agents↗

Evaluation of Oxford nanopore sequencing for antimicrobial resistance surveillance in Salmonella: comparison with phenotypic antimicrobial susceptibility in a large-scale study.

UNLABELLED: Salmonella is a major zoonotic foodborne pathogen, and antimicrobial resistance (AMR) in Salmonella presents a significant public health challenge. Compared with conventional antimicrobial susceptibility testing (AST), whole-genome sequencing (WGS) provides a more rapid and comprehensive approach to AMR characterization, thereby informing antimicrobial selection and supporting public health surveillance. In this study, Oxford Nanopore Technology (ONT)-based WGS was performed on 1,490 Salmonella isolates collected through nationwide surveillance in Taiwan in 2025. Genotypic resistance inferred from WGS data was compared with phenotypic AST results to assess the performance of ONT-WGS. Overall, WGS-inferred resistance showed high concordance with phenotypic resistance for most antimicrobials. However, major genotype-phenotype discordance was observed, attributed to four categories: (i) breakpoint-dependent classification, (ii) reduced or absent phenotypic expression of resistance genes, (iii) minimum inhibitory concentration (MIC) modulation by ramAp, and (iv) absence of known AMR determinants. Notable discrepancies included tigecycline resistance without known genetic determinants, nalidixic acid resistance linked to ramAp-mediated MIC elevation, and a high prevalence of colistin resistance (35.7%) in S. Enteritidis, with most resistant isolates lacking identifiable AMR determinants. Additionally, a significant proportion of ESBL- and AmpC-producing isolates were classified as susceptible or intermediate to cefotaxime and ceftazidime under CLSI criteria, highlighting the potential for misclassification and treatment failure. These findings demonstrate that ONT-WGS enables accurate and comprehensive AMR characterization by directly identifying resistance determinants and avoiding potential misclassification associated with breakpoint-based AST interpretations. When interpreted appropriately, WGS can support better antimicrobial selection and serve as a valuable alternative to conventional susceptibility testing. IMPORTANCE: Accurate prediction of antimicrobial resistance is essential for appropriate therapy and effective surveillance of Salmonella. However, discordance between genotype-based predictions and phenotypic antimicrobial susceptibility testing (AST) can complicate clinical interpretation. In this nationwide study of 1,490 Salmonella isolates, we show that Oxford Nanopore Technology-based whole-genome sequencing (ONT-WGS) provides rapid and comprehensive detection of antimicrobial resistance determinants with high concordance to phenotypic AST. We further identify four major mechanisms underlying genotype-phenotype discordance, including breakpoint-dependent classification, reduced or absent phenotypic expression of resistance genes, minimum inhibitory concentration (MIC) modulation by ramAp, and the absence of known AMR determinants. These findings demonstrate how WGS can complement conventional AST, improve interpretation of challenging susceptibility results, and strengthen genomic surveillance of emerging antimicrobial-resistant Salmonella.

Microbial Sensitivity Tests↗

Antimicrobial susceptibility testing of Neisseria gonorrhoeae and implications for epidemiology and therapy.

Antimicrobial susceptibility testing (AST) of Neisseria gonorrhoeae has been under development since the early days of antimicrobial agents. However, it is rarely applied to clinical isolates today. The history of the various in vitro tests to determine the susceptibility of N. gonorrhoeae to antibiotics is rich with evidence that these results predict response to therapy for almost all agents tested. Further, AST is a useful and important aspect of strain characterization and disease epidemiology in conjunction with the more specific but laborious techniques of auxotyping, serotyping, and plasmid analysis. Current technology has overcome many of the objections to AST for N. gonorrhoeae with standardization of test media and the development of an accurate disk diffusion AST method that is suited to most clinical laboratories regardless of volume or level of technical expertise. Ironically, the very low level of resistance to the current primary treatment strategy in the United States, ceftriaxone or another potent cephalosporin, makes the use of AST somewhat superfluous.

Anti-Bacterial Agents↗

Whole-Genome Sequencing Uncovers Chromosomal and Plasmid-Borne Multidrug Resistance and Virulence Genes in Poultry-Associated Escherichia coli from Nigeria.

BACKGROUND: Broad and unregulated antibiotic use in livestock production, particularly poultry farming, has increased the development and persistence of multidrug-resistant (MDR) bacterial strains in animals. These resistant pathogens and their antibiotic resistance genes (ARGs) can spread to humans through environmental exposure and the food chain, posing serious public health risks. Whole-genome sequencing (WGS), alongside phenotypic antimicrobial susceptibility testing (AST), enables a comprehensive understanding of resistance mechanisms and informs antimicrobial stewardship strategies, particularly in resource-limited settings. AIM: This study aimed to characterize the phenotypic and genotypic antimicrobial resistance profiles, plasmid content, and virulence factors of an MDR E. coli strain (S3) isolated from a poultry farm in Enugu State, Nigeria, to elucidate potential risks to public health and the role of poultry as a reservoir for resistance determinants. METHODS: E. coli strain S3 was isolated from chicken droppings using standard microbiological methods and confirmed by MALDI-TOF mass spectrometry. AST was assessed using disc diffusion and broth microdilution to determine minimum inhibitory concentrations (MICs) for ten antibiotics across multiple classes. WGS was performed with a hybrid approach combining Illumina and Nanopore platforms, followed by genome assembly and annotation. ARGs, plasmid replicons, and virulence factors were identified in silico using AMRFinderPlus, starAMR, RGI/CARD, PlasmidFinder, MOB-suite, and the Virulence Factor Database (VFDB). RESULTS: Phenotypic testing revealed extensive resistance, with complete resistance to six of seven tested antibiotics (cefotaxime, ampicillin, erythromycin, gentamicin, ciprofloxacin, and doxycycline). MICs exceeded clinical breakpoints for multiple classes, confirming an MDR phenotype. Genome analysis indicated a 5.33 Mb genome distributed across five contigs, including one chromosome and four plasmid-associated contigs. The strain harboured numerous ARGs, including bla CTX-M-15, bla OXA-1, bla TEM-1, aac(6')-Ib-cr, aadA5, aph(3")-Ib, sul1/sul2, tet(A), dfrA17, and mph(A), co-localized on plasmids indicative of horizontal gene transfer (HGT) potential. Plasmid types included Col156, IncF, and two rep clusters. Virulence profiling revealed genes associated with adhesion (pap cluster, ECP), iron acquisition (enterobactin, yersiniabactin, aerobactin, heme uptake), and toxins (sat, senB), highlighting the isolate's potential for urinary tract and intestinal infections. CONCLUSION: This study highlights the significant role of poultry-associated bacteria as reservoirs of AMR genes, particularly those harboured on mobile plasmids with potential for HGT. E. coli strain S3 exhibits extensive multidrug resistance and carries a complex plasmid repertoire facilitating horizontal transfer of ARGs. Coupled with a rich virulence gene profile, this strain underscores the public health risk posed by poultry-associated E. coli in Nigeria. These findings demonstrate the urgent need for stringent antimicrobial stewardship, regulatory oversight, and genomic surveillance in poultry production milieus to mitigate the dissemination of MDR pathogens.

Escherichia coli↗

Genomic and phenotypic characterization of mcr-9 carrying Enterobacter oligotrophicus recovered from bovine mastitis.

Bovine mastitis (BM) is a leading cause of economic loss in the dairy industry, driven by decreased milk yields, involuntary culling, and substantial veterinary costs. A single Gram-negative isolate recovered from BM was characterized in this study. For this, antimicrobial susceptibility testing (AST) was performed using the Neg-Urine-Combo 98 panel. Whole-genome sequencing (WGS) was employed to identify antimicrobial resistance genes (ARG), virulence factors (VF) genes, plasmid replicons and prophage sequences. Comparative genomic analysis was performed through phylogenetic analysis. The BM isolate was phenotypically identified as Citrobacter rodentium, however, WGS analysis reclassified the isolate as Enterobacter oligotrophicus. Phenotypic AST revealed a resistance profile of 12%, with the isolate exhibiting resistance to β-lactams antimicrobials, specifically amoxicillin-clavulanate, ampicillin and the cephalosporin-cefoxitin. Conversely, susceptibility was demonstrated for the remaining tested antimicrobials. Genomic profiling identified 31 ARG, 10 VF genes and 6 prophage sequences within the E. oligotrophicus genome. This study provides the first evidence of E. oligotrophicus as a causative agent of BM, expanding the known spectrum of pathogens affecting the dairy industry by delivering the second complete genome of E. oligotrophicus available globally. The identification of 31 ARG, 10 VF, and 6 prophage sequences underscore the potential pathogenic risk and environmental resilience of this isolate. These findings highlight the critical role of WGS-based surveillance in identifying non-conventional mastitis pathogens and underscore the need for targeted mitigation strategies in veterinary medicine.

Animals↗

Molecular epidemiology and genomic characteristics of clinical Acinetobacter baumannii isolates from patients with hospital-acquired pneumonia in China, 2019-2020: a multicentre retrospective study.

BACKGROUND: Carbapenem-resistant Acinetobacter baumannii (CRAB) is a leading cause of hospital-acquired pneumonia (HAP) with high mortality. However, large-scale nationwide data of HAP-causing CRAB in China remain limited. METHODS: Here, we performed a nationwide multicentre retrospective study to characterise the molecular epidemiology and genomic features of 802 A. baumannii isolates from patients with HAP across 33 tertiary hospitals in China during 2019-2020. Antimicrobial susceptibility testing (AST), whole-genome sequencing (WGS), phylogenetic and comparative genomic analysis were used to investigate molecular epidemiology of HAP-causing CRAB strain. Clinical comparative analyses were carried out on data from 500 patients with HAP stratified by distinct antimicrobial susceptibility and genomic profiles, and a Galleria mellonella infection model was utilised for in vivo virulence assessment. FINDINGS: The overall carbapenem resistance rate of A. baumannii was 82.0% (658/802), with marked regional variations. CRAB exhibited high resistance to conventional agents but remained largely susceptible to polymyxin, tigecycline, cefiderocol and sulbactam-durlobactam. Among enrolled patients, CRAB infection was linked to substantially higher mortality (39.0% vs. 17.5%), and multivariate analysis confirmed ICU admission and advanced age as independent risk factors for patients with CRAB infection. Molecular typing revealed STPas2 (96.2%) as the absolutely predominant type; STOxf208, STOxf195, STOxf540, and STOxf369 were the most prevalent Oxford sequence types with obvious geographic stratification and divergent comorbidity profiles among corresponding patients. A total of 654 CRAB isolates harboured carbapenemase genes, with blaOXA-23 dominating at 98.8%. Genomic analysis revealed lineage-specific features: STOxf208 carried more virulence genes, while STOxf540 harboured a broader antimicrobial resistance genes (ARGs). The STOxf208 clone mainly belonged to KL2 (62.1%) and KL7 (36.8%) serotypes, with KL2 strains possessing richer ARGs and virulence factors, and in vivo virulence assays further validated that KL2 strains possessed higher pathogenicity than KL7 strains. INTERPRETATION: This study demonstrates the extremely high prevalence and clonal dominance of CRAB in Chinese patients with HAP, providing critical evidence for clinical treatment, antimicrobial stewardship, and targeted infection control. FUNDING: National Key Research and Development Program of China (2024YFE0106200), National Natural Science Foundation of China (U22A20338, 82502763, W2621007), Zhejiang Provincial Natural Science Foundation of China (LQN25H190006), Zhejiang Provincial Postdoctoral Science Foundation (ZJ2025058).

Acinetobacter baumannii↗

Clinical carbapenem-resistant Enterobacterales in a University Hospital in Dakar, Senegal: genomic insights into Enterobacter hormaechei ST182 strains carrying blaNDM-5 and blaOXA-48 genes .

Senegal has witnessed the emergence and spread of carbapenem-resistant Enterobacterales (CRE), which often cause deadly infections. Accordingly, this study aimed to determine the antimicrobial susceptibility and prevalence of carbapenemases, as well as to perform a whole-genome sequence analysis of clinical CRE isolates from a university hospital in Dakar, Senegal. MALDI-TOF MS and VITEK2 systems were used for bacterial identification and antimicrobial susceptibility testing (AST). Carbapenemase- and cephalosporinase-encoding genes were screened using simplex end-point polymerase chain reaction. Whole-genome sequencing (WGS) was performed using the Illumina MiSeq platform. The CRE isolates were resistant to almost all the 34 antimicrobials tested. Nevertheless, colistin and amikacin remained active, with susceptibility rates of 96% and 71%, respectively. Only the carbapenemase genes blaOXA-48 (53.8%; 15/28) and blaNDM (35.7%; 10/28) and the cephalosporinase gene blaCMY-1 (25%; 7/28) were identified. In this context, two extensively drug-resistant Enterobacter hormaechei isolates were subjected to WGS analysis. These isolates were assigned as sequence type (ST) 182 and carried several genes related to antimicrobial resistance (AMR), metal tolerance, and virulence. An IncL/M plasmid with 61,054 bp in length was identified as carrying the blaOXA-48 gene, whereas an IncFIB(pECLA)/IncFII(pECLA)/IncX3 mutireplicon plasmid with 217,745 bp in length was detected as harboring the blaNDM-5 gene and other genes related to AMR and metal tolerance. Our study presents the first landscape of clinical CRE circulating in Senegal, along with additional genomic analysis of E. hormaechei ST182 strains, which could be useful for mitigating the burden associated with CRE in this country.IMPORTANCEThe investigation of global critical priority CRE isolates has become crucial to reduce morbidity and mortality associated with AMR. This study revealed that colistin and amikacin can be considered good alternatives for treating CRE-associated infections in Dakar. In addition, the genomic approach revealed that the CRE isolates carried both a wide resistome and virulome. Moreover, the abundance of horizontal gene transfer regions in the genomes suggests the great implications of mobile genetic elements in the spread of AMR in Dakar. Furthermore, this study reported the complete sequences of chromosomes and blaOXA-48 and blaNDM-5-carrying plasmids. Our findings are of great importance because complete genome sequences are still rarely characterized in the West African region. Finally, this study highlights the importance of strengthening genomic surveillance of CRE in sub-Saharan African countries to mitigate the burden associated with these pathogens.

Senegal↗

Validation of the automated reading and incubation system with Sensititre plates for antimicrobial susceptibility testing.

The present study compared the antimicrobial susceptibility testing (AST) results generated by the Automated Incubation and Reading System (ARIS) with custom Sensititre plates (TREK Diagnostic Systems, Cleveland, Ohio) and MicroScan PC10 GP and NUMIC10 GN plates interpreted with the WalkAway-96 system (Dade Behring, West Sacramento, Calif.) for gram-positive (GP) and gram-negative (GN) organisms as part of an in-house validation. A total of 326 isolates (3,689 antimicrobial agent-organism combinations) were evaluated. Sensititre plates were inoculated according to the instructions of the manufacturer with a suspension adjusted to a 0.5 McFarland standard, while the Prompt Inoculation System was used for the MicroScan plates. ARIS and the WalkAway system were used for automated reading of the Sensititre and MicroScan plates, respectively, at 18 to 24 h. The results were analyzed for essential (+/-1 twofold dilution) and categorical (sensitive, intermediate, or resistant) agreements. Plates that resulted in ARIS interpretations with major (falsely resistant) or very major (falsely susceptible) errors compared to the results obtained with the WalkAway system were read manually to corroborate instrument readings. Isolates for which very major or major errors were obtained and for which the results were not resolved by manual reading were retested in parallel. Isolates for which very major or major errors were obtained and for which the results were not resolved upon repeat testing were tested by the National Committee for Clinical Laboratory Standards M7-A5 frozen reference microdilution method. Essential agreement was 95.8% for 246 GN isolates. The following categorical error rates were obtained for the GN isolates: 1.3% minor errors, 0% major errors, and 0.4% very major errors. For 95 GP isolates, there was 93.5% essential agreement. Categorical error rates for GP isolates were 0.9% minor errors, 0.6% major errors, and 0.4% very major errors. ARIS-Sensititre is a diagnostic system feasible for use for automated AST in a clinical laboratory.

Automation↗

Accuracy of the Vitek system for antimicrobial susceptibility testing Enterobacteriaceae bloodstream infection isolates: use of "direct" inoculation from Bactec 9240 blood culture bottles.

A recent investigation indicates that rapid antimicrobial susceptibility tests (AST) can affect patient therapy leading to reductions in health-care costs for some patient populations. However, there is little information relative to the often performed direct inoculation of positive blood culture bottles into rapid AST systems. AST results of direct inoculated Vitek (bioMerieux Vitek, Hazelwood, MO, USA) GNS cards were compared to those inoculated per package insert recommendations and a reference broth microdilution test using 50 consecutive Enterobacteriaceae bloodstream infection isolates. Escherichia coli (44% of isolates), Klebsiella ssp. (30%), and six other members of this family were tested against 15 antimicrobial agents. The direct inoculation method produced only two false-susceptible (0.3%), seven false-resistant (0.9%; six different drugs), and 48 minor errors (6.4%). The GNS cards inoculated in the usual, recommended manner had no very major error, and 7.5% combined major and minor errors. If the results of the urinary infection-specific drugs (nitrofurantoin, trimethoprim/sulfamethoxazole; not appropriate for bacteremia therapy) and ampicillin/sulbactam were deleted, both Vitek inoculation methods yielded results well within acceptable limits (< or = 4.5% overall error). These results indicate that the direct inoculation method of Vitek GNS cards from Enterobacteriaceae bloodstream infections (detected by Bactec 9240, Becton-Dickinson, Cockeysville, MD, USA) performed as well as the NCCLS broth microdilution test. Thus, a procedural modification of this type could further accelerate rapid access to accurate AST data.

Bacteremia↗

[Drug susceptibility of Pseudomonas aeruginosa strains isolated from patients of a hospital and specialistic outpatients clinics of the SP ZOZ in Nidzica].

The aim of this study was to evaluate a frequency of isolation and antimicrobial susceptibility testing (AST) of Pseudomonas aeruginosa strains cultured from clinical specimens collected from patients hospitalized in wards and specialistic outpatients clinics of a hospital in Nidzica (01. 09. 2000 -31. 12. 2003). During over three years 392 Pseudomonas aeruginosa strains were cultured from 16346 clinical samples provided to bacteriological laboratory. P. aeruginosa strains were isolated from 2.5% of examined specimens. Susceptibility of Pseudomonas aeruginosa strains to antimicrobial agents was tested. The highest in vitro activity against clinical P. aeruginosa strains demonstrated imipenem. One strain was resistant to imipenem. This strain was isolated from a patient of a surgical department. Metalo-beta-lactamase was not detected (MBL-negative strain). Twenty nine strains were ESBL producer (7.4% of all strains). The contribution of Pseudomonas aeruginosa strains to the etiology of nosoconial and ambulatory infections increases. In vitro activity of antibacterial agents against P. aeruginosa strains should be monitored during therapy of infections. Resistance to antibiotics/chemothe-rapeutics may be acquired during treatment with antibacterial agent to which P. aeruginosa strain was susceptible according to the antibiogram.

Adult↗

Two-center collaborative evaluation of the performance of the BD Phoenix automated microbiology system for identification and antimicrobial susceptibility testing of Enterococcus spp. and Staphylococcus spp.

The performance of the BD Phoenix Automated Microbiology System (BD Diagnostic Systems, Sparks, Md.) was assessed for identification (ID) and antimicrobial susceptibility testing (AST) for the majority of clinically encountered bacterial isolates in a European collaborative two-center trial. A total of 469 bacterial isolates of the genera Staphylococcus (275 isolates), Enterococcus (179 isolates), and Streptococcus (15 isolates, for ID only) were investigated; of these, 367 were single patient isolates, and 102 were challenge strains tested at one center. Sixty-four antimicrobial drugs were tested, including the following drug classes: aminoglycosides, beta-lactam antibiotics, beta-lactam-beta-lactamase inhibitors, carbapenems, cephems, folate antagonists, quinolones, glycopeptides, macrolides-lincosamides-streptogramin B (MLS), and others. Phoenix ID results were compared to those of the laboratories' routine ID systems (API 32 Staph, API 32 Strep, and VITEK 2 [bioMérieux, Marcy l'Etoile, France]); Phoenix AST results were compared to those of frozen standard broth microdilution (SBM) panels according to NCCLS guidelines (NCCLS document M 100-S 9, approved standard M 7-A 4). Discrepant results were repeated in duplicate. Concordant IDs of 97.1, 98.9, and 100% were observed for staphylococci, enterococci, and streptococci, respectively. For AST results the overall essential agreement was 93.3%; the category agreement was 97.3%; and the very major error rate, major error rate, and minor error rate were 1.2, 1.9, and 1.3%, respectively. In conclusion, the Phoenix ID results showed high agreement with results of the systems to which they were being compared; the AST performance was highly equivalent to that of the SBM reference method.

Anti-Bacterial Agents↗

Comparison of workflow and accuracy of identification and antimicrobial susceptibility testing of clinical isolates of Enterobacteriaceae, Pseudomonas aeruginosa and enterococci by Vitek 2 and routine methods.

Three hundred and fifty-three consecutive urine cultures growing Enterobacteriaceae, Pseudomonas aeruginosa or enterococci were subjected to parallel identification (ID) and antimicrobial susceptibility testing (AST) by Vitek 2 and routine methods, including simple screening tests or API 20 E for ID and standardized disc diffusion for AST. Accuracy of results, technician hands-on time required by both methods and time to results were compared. Vitek 2 correctly identified 322 (94.7%) of the 340 gram-negative isolates and 17 (81%) of the 21 Enterococcus faecalis strains. AST by Vitek 2 and disc diffusion gave category agreement for 4,058 (95.5%) of 4,248 organism-antimicrobial agent combinations. With MIC determination by E-test as reference, AST by Vitek 2 and disc diffusion produced 15 and 3 very major errors, respectively. Six (40%) of the fifteen very major errors by Vitek 2 were associated with trimethoprim-sulfamethoxazole. With an average of 22 specimens processed per day, use of Vitek 2 saved 80 min per day of technician hands-on time as compared to routine methods. Regarding the cost of hands-on worktime and consumables, use of Vitek 2 for identification of Escherichia coli-screened Enterobacteriaceae saved 0.70 p per sample in comparison to API 20 E. More than 80% of Enterobacteriaceae introduced to Vitek 2 in the morning could be reported by 16:00.

Anti-Bacterial Agents↗

Two-center collaborative evaluation of performance of the BD phoenix automated microbiology system for identification and antimicrobial susceptibility testing of gram-negative bacteria.

The performance of the BD Phoenix Automated Microbiology System (BD Diagnostic Systems, Sparks, MD) was assessed for identification (ID) and antimicrobial susceptibility testing (AST) of the majority of clinically encountered bacterial isolates in a European collaborative two-center trial. A total of 494 bacterial isolates including various species of the Enterobacteriaceae and 110 nonfermentative gram-negative bacteria were investigated: of these, 385 were single patient isolates, and 109 were challenge strains tested at one center. The performance of the Phoenix extended-spectrum beta-lactamase (ESBL) test was also evaluated for 203 strains of Escherichia coli, Klebsiella pneumoniae, and Klebsiella oxytoca included in the study. Forty-two antimicrobial drugs were tested, including members of the following drug classes: aminoglycosides, beta-lactam antibiotics, beta-lactam/beta-lactamase inhibitors, carbapenems, cephems, monobactams, folate antagonists, quinolones, and others. Phoenix system ID results were compared to those of the laboratories' routine ID systems (API 20E and API CHE, ATB ID32E, ID32GN, and VITEK 2 [bioMérieux, Marcy l'Etoile, France]); Phoenix AST results were compared to those of frozen standard broth microdilution (SBM) panels according to NCCLS (now CLSI) guidelines (NCCLS document M100-S9, approved standard M7-A4). Discrepant results were repeated in duplicate. Concordant IDs of 98.4 and 99.1% were observed for the Enterobacteriaceae and the nonfermentative group, respectively. For AST results, the overall essential agreement was 94.2%; the category agreement was 97.3%; and the very major error rate, major error rate, and minor error rate were 1.6, 0.6, and 1.9%, respectively. In terms of ESBL detection, Phoenix results were 98.5% concordant with those of the reference system, with 98.0% sensitivity and 98.7% specificity. In conclusion, the Phoenix ID results showed high agreement with results of the systems to which they were being compared: the AST performance was highly equivalent to that of the SBM reference method, and the system proved to be very accurate for the detection of ESBL producers.

Automation↗

Drug resistant Klebsiella pneumoniae from patients and hospital effluent: a correlation?

BACKGROUND: The application of wastewater-based epidemiology has gained traction as a cost effective tool in antimicrobial resistance (AMR) surveillance with studies showing a correlation between the presence of resistant bacteria from hospital sewage and patients. This study compared Klebsiella pneumoniae from patients and hospital effluent in terms of antibiotic resistance patterns, antibiotic resistance genes (ARGs), mobile genetic elements (MGEs) and phylogenomic relationships. RESULTS: Pooled effluent samples were collected from the final effluent point of a regional hospital and K. pneumoniae isolates were identified on selective media. Clinical isolates were also collected from the same hospital. Antimicrobial susceptibility testing (AST) was performed using the VITEK&#xae; 2 system. DNA was extracted prior to whole genome sequencing (WGS). The resistome, mobilome, and phylogenetic lineages of sequenced isolates were assessed using bioinformatics analysis. A total of 10 randomly selected presumptive and 10 clinical K. pneumoniae constituted the sample and were subjected to AST. Total resistance was observed in the clinical samples to cefuroxime, cefotaxime, piperacillin/tazobactam, gentamicin, tobramycin and trimethoprim/sulfamethoxazole. The effluent isolates exhibited total susceptibility to most antibiotics but showed resistance to amoxicillin/clavulanic acid and piperacillin/tazobactam (100%), and tigecycline (10%). The effluent isolates did not exhibit a diverse resistome, while the clinical isolates harboured genes conferring resistance to aminoglycoside (aph(6)-Id, aph(3'')-Ib, aac(6')-Ib-cr, aadA16), &#xdf;-lactam (blaSVH group, blaOXA group, blaTEM group), and fluoroquinolone (oqxA, oqxB) antibiotics. Only class 1 integrons were identified. Phylogenetic analysis revealed that effluent isolates from this study were not closely related to the clinical isolates. CONCLUSION: This study showed no correlation between the resistance profiles of the clinical and effluent isolates. The relationship between AMR in hospital effluent and clinical resistance may depend on the antimicrobial agents and bacterial species studied.

Klebsiella pneumoniae↗

Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing.

To assess the expected clinical and financial benefits of rapid reporting of microbiology results, we compared patients whose cultured samples were processed in the normal manner to patients whose samples were processed more rapidly due to a minor change in work flow. For the samples tested in the rapid-reporting time period, the vast majority of bacterial identification and antimicrobial susceptibility testing (AST) results were verified with the Vitek system on the same day that they were available. This time period was called rapid AST (RAST). For RAST, a technologist on the evening shift verified the data that became available during that shift. For the control time period, cultures were processed in the normal manner (normal AST [NAST]), which did not include evening-shift verification. For NAST, the results for approximately half of the cultures were verified on the first day that the result was available. The average turnaround time for the reporting of AST results was 39.2 h for RAST and 44.4 h for NAST (5.2 h faster for RAST [P = 0.001]). Subsequently, physicians were able to initiate appropriate antimicrobial therapy sooner for patients whose samples were tested as part of RAST (P = 0.006). The mortality rates were 7. 9 and 9.6% for patients whose samples were tested as part of RAST and NAST, respectively (P = 0.45). The average length of stay was 10. 7 days per patient for RAST and 12.6 days for NAST, a difference of 2.0 days less for RAST (P = 0.006). The average variable cost was $4, 927 per patient for RAST and $6,677 for NAST, a difference of $1,750 less per patient for RAST (P = 0.001). This results in over $4 million in savings in variable costs per year in our hospital.

Bacteria↗

Detection of antibiotic heteroresistance in clinical microbiology: current and emerging methodologies.

BACKGROUND: Antibiotic heteroresistance (HR) is characterised by the coexistence of susceptible and resistant subpopulations within an apparently isogenic bacterial isolate. Because routine antimicrobial susceptibility testing (AST) primarily assesses the dominant population, HR may escape detection, potentially leading to discrepancies between laboratory susceptibility categorisation and the underlying bacterial population structure. OBJECTIVES: To provide a critical and practice-oriented evaluation of current and emerging methodologies for HR detection and to discuss their strengths, limitations, and potential for clinical implementation. SOURCES: Narrative review based on PubMed searches, complemented by screening of key reference lists and relevant EUCAST and CLSI documents. Peer-reviewed literature was prioritised. CONTENT: Phenotypic approaches, particularly population analysis profiling, remain the reference method for HR definition, but their labour-intensive workflows, long turnaround times, and limited standardisation restrict routine implementation. Alternative strategies, including modified AST assays, metabolic assays, and single-cell platforms, offer gains in speed or throughput but require broader validation. Molecular approaches such as quantitative PCR, droplet digital PCR, targeted deep sequencing, and whole-genome sequencing improve detection of minority resistance determinants. Emerging computational frameworks, including machine learning models integrating phenotypic and genomic data, represent a promising frontier for scalable HR prediction. IMPLICATIONS: Available evidence supports the clinical relevance of HR, although its association with adverse outcomes varies across bacterial species and antibiotic classes. Harmonised methodologies and clinically validated interpretive criteria are needed to support integration of HR assessment into routine diagnostics. Prospective multicentre studies and further standardisation, including engagement with EUCAST and CLSI, will be important to advance clinical implementation.

Antimicrobial resistance↗

Antimicrobial susceptibility testing in European hospitals: report from the ARPAC study.

This observational study describes the antimicrobial susceptibility testing (AST) methods and interpretive criteria used in European hospitals during 2001, focusing specifically on detection of methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE). Of 263 hospitals that took part in the ARPAC study, 192 submitted data on AST. Of these, 89% (n = 170) routinely used a disk-diffusion AST method, 43% (n = 82) used a semi-automated method, and 70% (n = 135) routinely determined MICs. Hospitals in southern Europe were less likely to use disk-diffusion, but were more likely to use a semi-automated method (p <0.001). In total, 173 (90%) interpreted AST results using CLSI breakpoints; 30% of these detected MRSA using unmodified CLSI disk-diffusion methods, while 35% used the unmodified CLSI agar-screening method for MRSA; 41% and 30% adhered to unmodified CLSI methodology for disk-diffusion and agar-screening, respectively, to detect VRE. Some of the modifications made may have greatly reduced the ability of the tests to detect MRSA/VRE. For example, 20% of respondents used excessively high incubation temperatures and 13% used inadequate incubation times to detect MRSA by disk-diffusion, and 28% used Mueller-Hinton agar instead of brain-heart infusion agar in VRE screening plates. The majority of respondents stated that they followed CLSI guidelines, but a high proportion had modified the CLSI methods for detecting MRSA and VRE, which may compromise clinical management and antimicrobial resistance surveillance.

Enterococcus↗

Vitek GPS card susceptibility testing accuracy using direct inoculation from BACTEC 9240 blood culture bottles.

The emergent need for antimicrobial susceptibility testing (AST) data for the therapy of bacteremic patients has led to the development of rapid methods and local procedure modification of some commercial AST products such as the direct inoculation from blood culture systems. We compared the Vitek GPS card results using direct and standardized inoculation with a reference broth microdilution method for 112 consecutive staphylococcal bloodstream infections (seven drugs). Among the 28 Staphylococcus aureus strains, 0%-3.6% total error/drug was observed with both Vitek inoculation procedures. However, the only oxacillin-resistant strain was not detected (100% true very-major error). For 84 coagulase-negative staphylococci (CNS), the direct inoculation procedure had an 11.9% very-major error rate for oxacillin, ampicillin-sulbactam, and cephalothin, plus 4.8% very-major error rate for ciprofloxacin and trimethoprim-sulfamethoxazole (total error rate 4.8%-16.7% for five of seven drugs compared). The Vitek direct inoculation procedure routinely missed 20.4% of oxacillin-resistant CNS strains. The use of Vitek direct inoculation procedures for staphylococcal bloodstream infection isolates (from BACTEC 9240 cultures) produced serious false-susceptible results; this procedure should be avoided in favor of routine package insert-recommended Vitek procedures or other reference-quality overnight incubation susceptibility tests.

Bacteremia↗