PubMed HealthSearch

SEARCH · PubMed Health

Results for “conventional laryngoscope”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

4 recordsLinked to original sources

Less Invasive Surfactant Administration Using Video Laryngoscope to Decrease Pain in Neonates: A Randomized Controlled Trial.

OBJECTIVES: To assess whether the use of video laryngoscope, when compared to conventional laryngoscope decreases pain (assessed by Faceless Acute Neonatal Pain Scale) in preterm neonates while administering surfactant by LISA. METHODS: Preterm neonates <&#x2009;35 weeks requiring FiO2&#x2009;>&#x2009;0.3 on CPAP pressure of at least 6&#x2009;cm of H2O were administered surfactant by LISA technique either by video laryngoscope (Intervention) or conventional laryngoscope (Control). Faceless Acute Neonatal Pain Scale was used to determine pain 5&#x2009;min before the procedure, immediately, 5&#x2009;min, and 10&#x2009;min after the procedure. The primary outcome was severity of pain; secondary outcomes were time taken to complete the procedure, number of attempts, incidence of IVH, and adverse events during the procedure. RESULTS: In total, 42 neonates of <&#x2009;35 weeks gestation with comparable baseline demographics were randomized into 2 groups. The median (IQR) FANS score immediately post-procedure in the intervention arm was 2 (2-4) versus 2 (1-4) in the control arm, p&#x2009;=&#x2009;0.79. There was no statistical difference in the secondary outcomes studied. CONCLUSION: The two groups had no difference in the pain score. The pain experienced by neonates during the LISA procedure was moderate and of short duration and it did not depend on the type of laryngoscope used. Moderate pain during the procedure can be managed with nonpharmacological measures; thereby, the use of sedatives or analgesics can be avoided, which might be of concern. There was no difference in the number of attempts or in time taken to complete the procedure when performed by neonatologists experienced in using conventional laryngoscopes compared to video laryngoscopes. TRIAL REGISTRATION: Clinical Trial Registry of India: CTRI/2022/09/045204 on 05.09.2022.

Humans

The fibreoptic laryngoscope in the management of cut throat injuries.

The trachea of a man who had cut his own throat was successfully intubated using a fibreoptic laryngoscope after attempts at conventional oral intubation had failed. The advantages of the fibreoptic instrument and the method of use in such an injury are discussed.

Fiber Optic Technology

Intralaryngeal surgery 1977.

A very brief history of laryngoscopy and intralaryngeal surgery up to the present time is outlined. A simple comparison of some of the conventional laryngeal instruments with CO2 laser capability is made, and the common one-handed and two-handed surgical techniques are outlined. Four cases are presented, each of which demonstrates a significant feature of laryngoscopic surgery.

Aged

Re-evaluating pediatric laryngoscope blade size recommendations: Comparable intubation performance across blade sizes in pediatric manikin models.

BACKGROUND: Pediatric airway management traditionally emphasizes strict adherence to age-based laryngoscope blade size recommendations, despite limited empirical validation. OBJECTIVES: To evaluate whether intubation performance varies across a range of blade sizes, and whether a Macintosh 2 blade performs comparably across multiple pediatric age groups in a simulation setting. METHODS: We conducted a randomized crossover simulation study using three pediatric airway manikins (neonate, infant, and child age groups). Emergency medicine residents and faculty physicians performed intubations using multiple laryngoscope blade types and sizes, including standard and nonstandard options. Primary outcomes were intubation time and first-attempt success. Secondary outcomes included complications and operator-rated ease of glottic view and tube passage. Between-blade differences were estimated with 95% confidence intervals. RESULTS: Across manikin sizes and blade types, intubation times were short and first-attempt success rates exceeded 98% in most conditions. Performance remained consistent even with blade sizes outside conventional age-based recommendations. Between-blade differences in intubation time were small, and complication rates were low across conditions. The Macintosh 2 blade performed comparably across all manikin sizes, with similar intubation times, high success rates, and favorable ease ratings. CONCLUSIONS: Intubation performance in pediatric manikin models was similar across a wide range of blade sizes. These hypothesis-generating findings warrant prospective clinical evaluation of simplified blade selection strategies for pediatric intubation.

Manikins