PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “degrees of freedom”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Computer control of a powered two degree freedom reciprocating gait orthosis.

The design of a motion control system for a powered reciprocating gait orthosis is considered. Models for the orthosis are obtained using least squares identification. The control system design is based on pole-placement techniques and a restricted Youla parametrization of the controller. Experimental results are included.

Algorithms↗

Control performance with three translational degrees of freedom.

For multiple degree-of-freedom (DOF) systems, it is important to determine how accurately operators can control each DOF and what influence perceptual, information processing, and psychomotor components have on performance. Sixteen right-handed male students participated in 2 experiments: 1 involving positioning and 1 involving tracking with 3 translational DOFs. To separate perceptual and psychomotor effects, we used 2 control-display mappings that differed in the coupling of vertical and depth dimensions to the up-down and fore-aft control axes. We observed information processing effects in the positioning task: Initial error correction on the vertical dimension lagged in time behind the horizontal dimension. The depth dimension error correction lagged behind both, which was ascribed to the poorer perceptual information. We observed this perceptual effect also in the tracking experiment: Tracking error along the depth dimension was 3.8 times larger than along the other dimensions. Motor effects were also present, with tracking errors along the up-down axis of the hand controller being 1.1 times larger than along the fore-aft axis. These results indicate that all 3 components contribute to control performance. Actual applications of this research include interface design for remote control and virtual reality.

Adult↗

Degenerate resonances in Hamiltonian systems with 3/2 degrees of freedom.

Hamiltonian systems with 3/2 degrees of freedom close to autonomous systems are considered. Special attention is focused on the case of degenerate resonances. In this case, an averaged system in the first approximation reduces to an area-preserving mapping of a cylinder whose rotation number is a nonmonotonic function of the action variable. Behavior of the trajectories of such a map is similar to that of the trajectories of a Poincare map. Three regions: B(+/-) in the upper and lower parts of the cylinder and an additional region A which contains separatrices of fixed points for the corresponding resonance are distinguished on the cylinder. It is shown that there is a nonempty set of initial points corresponding to walking trajectories in B(+/-) and, hence, there are no closed invariant curves that are homotopically nontrivial on the cylinder. Cells limited by a "stochastic network" can exist in region A. The number of cells is the greater the higher the order of degeneration of the resonance. Possible types of orbit behavior in region A are described. (c) 2002 American Institute of Physics.

Journal Article↗

Coordination of multiple muscles in two degree of freedom elbow movements.

The present study quantifies electromyographic (EMG) magnitude, timing, and duration in one and two degree of freedom elbow movements involving combinations of flexion-extension and pronation-supination. The aim is to understand the organization of commands subserving motion in individual and multiple degrees of freedom. The muscles tested in this study fell into two categories with respect to agonist burst magnitude: those whose burst magnitude varied with motion in a second degree of freedom at the elbow, and those whose burst magnitude depended on motion in one degree of freedom only. In multiarticular muscles contributing to motion in two degrees of freedom at the elbow, we found that the magnitude of the agonist burst was greatest for movements in which a muscle acted as agonist in both degrees of freedom. The burst magnitudes for one degree of freedom movements were, in turn, greater than for movements in which the muscle was agonist in one degree of freedom and antagonist in the other. It was also found that, for movements in which a muscle acted as agonist in two degrees of freedom, the burst magnitude was, in the majority of cases, not different from the sum of the burst magnitudes in the component movements. When differences occurred, the burst magnitude for the combined movement was greater than the sum of the components. Other measures of EMG activity such as burst onset time and duration were not found to vary in a systematic manner with motion in these two degrees of freedom. It was also seen that several muscles which produced motion in one degree of freedom at the elbow, including triceps brachii (long head), triceps brachii (lateral head), and pronator quadratus displayed first agonist bursts whose magnitude did not vary with motion in a second degree of freedom. However, for the monoarticular elbow flexors brachialis and brachioradialis, agonist burst magnitude was affected by pronation or supination. Lastly, it was observed that during elbow movements in which muscles acted as agonist in one degree of freedom and antagonist in the other, the muscle activity often displayed both agonist and antagonist components in the same movement. It was found that, for pronator teres and biceps brachii, the timing of the bursts was such that there was activity in these muscles concurrent with activity in both pure agonists and pure antagonists.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Stabilization and destabilization of perception--action patterns influence the self-organized recruitment of degrees of freedom.

The recruitment of an additional biomechanical degree of freedom in a unimanual rhythmic task was explored. Subjects were asked to synchronize adduction or abduction of their right index finger with a metronome, the frequency of which was increased systematically. In addition, haptic contact on or off the metronome beat was provided. Results showed that the pattern exhibiting the highest intrinsic stability recruited the vertical plane more than did the less stable one. Moreover, presence and location of haptic contact modulated coordination stability and therefore induced changes in the recruitment of the vertical plane. Thus, a trade-off was shown between coordination stability on the horizontal plane and recruitment of the vertical one. These findings suggest that recruitment of degrees of freedom is governed by general principles of coordination dynamics.

Adult↗

Instrumentation in neonatal research: commonly used statistics.

Nurse researchers share one common characteristic: They all use statistical tests to provide the answers they are seeking. For others to correctly interpret research, it is important to understand what choices of tests are available and why a test was used. As nursing becomes more sophisticated in the research arena, the ability to read, interpret, and critique reported research findings becomes an important component of professional practice. This month's column contains a description of commonly used statistical tests. Researchers are often interested in differences between groups and relationships between variables. Examples of these two types of research are provided to illustrate use of the various tests. One common part of statistical tests examining differences between groups is the number of degrees of freedom. Degrees of freedom are usually defined as the number of observations (number of subjects or categories) minus the number of limitations placed on those observations. Examples of this concept are provided throughout the pertinent tests.

Humans↗

Control of Three- and Four-Joint Arm Movement: Strategies for a Manipulator With Redundant Degrees of Freedom.

Control of arm movements when the number of joints exceeds the degrees of freedom necessary for the task requires a strategy for selecting specific arm configurations out of an infinite number of possibilities. This report reviews strategies used by human subjects to control the shoulder, elbow, and wrist (three degrees of freedom) while moving a pointer to positions in a horizontal plane (two degrees of freedom). Analysis of final arm configurations assumed when the pointer was at the target showed the following: (a) Final arm configurations were virtually independent of the configuration at the start of the pointing movement, (b) subjects avoided configurations subjectively felt to be uncomfortable (e.g., those with extreme flexion or extension of the wrist), and (c) the results could be simulated by assigning hypothetical cost functions to each joint and selecting the arm configuration that minimized the sum of the costs. The fitted cost functions qualitatively agreed with psychophysically determined comfort; they appeared to depend on joint angle and on muscular effort. Simple neural networks can learn implicit representations of these cost functions and use them to specify final arm configurations. The minimum cost principle can be extended to movements that use the fingers as a fourth movable segment. For this condition, however, experiments showed that final configurations of the arm depended upon initial configurations. Analysis of movement trajectories for arms with three degrees of freedom led to a control model in which the minimum cost principle is augmented by a mechanism that distributes required joint movements economically among the three joints and a mechanism that implements a degree of mass-spring control.

Journal Article↗

A light weight compliant hand mechanism with high degrees of freedom.

This paper presents the design and prototyping of an inherently compliant lightweight hand mechanism. The hand mechanism itself has 15 degrees of freedom and five fingers. Although the degrees of freedom in each finger are coupled, reducing the number of independent degrees of freedom to 5, the 15 degrees of freedom of the hand could potentially be individually actuated. Each joint consists of a novel flexing mechanism that is based on the loading of a compression spring in the axial and transverse direction via a cable and conduit system. Currently, a bench top version of the prototype is being developed; the three joints of each finger are coupled together to simplify the control system. The current control scheme under investigation simulates a control scheme where myoelectric signals in the wrist flexor and extensor muscles are converted in to x and y coordinates on a control scheme chart. Static load-deformation analysis of finger segments is studied based on a 3-dimensional model without taking the stiffener into account, and the experiment validates the simulation.

Biomimetics↗

Control of a single degree of freedom artificial hand.

A commercial single degree of freedom artificial hand has been fitted with touch, slip and position sensors, which permit low-level control tasks to be performed by a microprocessor; little conscious effort is required by the wearer. Hardware and software for the microprocessor system are described.

Biomedical Engineering↗

Coordination of mono- and bi-articular muscles in multi-degree of freedom elbow movements.

We investigated the coordination of mono- and bi-articular muscles during movements involving one or more degrees of freedom at the elbow. Subjects performed elbow flexion (or extension) alone, forearm pronation (or supination) alone, and combinations of the two. In bi-articular muscles such as biceps brachii and pronator teres, the amplitude of agonist electromyographic (EMG) activity was dependent on motion in the two degrees of freedom. Agonist burst amplitudes for combined movements were approximately the sum of the agonist burst amplitudes for movements in the individual degrees of freedom. Activity levels in individual degrees of freedom were, in turn, greater than activity levels observed when a muscle acted as agonist in one degree of freedom and antagonist in the other. Other muscles such as triceps, brachialis, and pronator quadratus acted primarily during motion in a single degree of freedom. The relative magnitude and the timing of activity between sets of muscles also changed with motion in a second degree of freedom. These patterns are comparable with those reported previously in isometric studies.

Elbow↗

Dynamic complexity of visuo-motor coordination: an extension of Bernstein's conception of the degrees-of-freedom problem.

Extending Bernstein's spatial conception of the degrees-of-freedom problem in the human motor system, we introduce a method developed from the theory of non-linear dynamics that allows one to quantify the spatio-temporal, i.e. dynamic, complexity of visuo-motor coordination. The correlation dimension D is used to measure the effective number of dynamic degrees of freedom in the coordination that a subject uses when performing a visuo-motor tracking task. The validity of the estimator employed is demonstrated. Visuo-motor coordination had a low-dimensional (mean D-SD=6.07 -0.82) dynamic structure, which was consistent with deterministic chaos rather than with pure stochastic noise. D correlated with tracking performance, P. Both D and P were closely related to the degree of visuo-motor compatibility that the task presented to the subject. However, for short periods of training P increased, but D did not. As these seemingly contradictory results suggest, our dynamic conception of the degrees-of-freedom problem may reveal far more intricate visuo-motor interactions than Bernstein could identify on the basis of his spatial analyses of bodily movement patterns and by the methods of evaluation that were available to him at the time.

Adult↗

Predictions of co-contraction depend critically on degrees-of-freedom in the musculoskeletal model.

In biomechanics, the calculation of individual muscle forces during movements is based on a model of the musculoskeletal system and a method for extracting a unique set of muscle forces. To obtain a unique set of muscle forces, non-linear, static optimisation is commonly used. However, the optimal solution is dependent on the musculoskeletal geometry, and single joints may be represented using one, two or three degrees-of-freedom. Frequently, a system with multiple degrees-of-freedom is replaced with a system that contains a subset of all the possible degrees-of-freedom. For example, the cat ankle joint is typically modelled as a planar joint with its primary degree-of-freedom (plantar-dorsiflexion), whereas, the actual joint has three rotational degrees-of-freedom. Typically, such simplifications are justified by the idea that the reduced case is contained as a specific solution of the more general case. However, here we demonstrate that the force-sharing solution space of a general, three degrees-of-freedom musculoskeletal system does not necessarily contain the solutions from the corresponding one or two degrees-of-freedom systems. Therefore, solutions of a reduced system, in general, are not sub-set solutions of the actual three degrees-of-freedom system, but are independent solutions that are often incompatible with solutions of the actual system. This result shows that representing a three degrees-of-freedom system as a one or two degrees-of-freedom system gives force-sharing solutions that cannot be extrapolated to the actual system, and vice-versa. These results imply that general solutions cannot be extracted from models with fewer degrees-of-freedom than the actual system. They further emphasise the need for precise geometric representation of the musculoskeletal system, if general force-sharing rules are to be derived.

Algorithms↗

Three degree of freedom description of movement of the human chest wall.

A three degree of freedom description of movement of the human chest wall is presented. In addition to the standard variables representing surface displacements of the rib cage and abdominal wall in transverse planes, the description includes a variable representing axial displacements of the chest wall associated with postural movements of the spine and pelvis. A simple technique was developed for quantifying the axial displacements using a single measurement by magnetometry of changes in the distance between a point on the anterior surface of the rib cage near the xiphisternum and a point on the abdominal surface near the pubic symphysis. It was found that axial displacements produced by either flexion-extension of the spine or rotation of the pelvis in the standing postures can be treated as a single degree of freedom. The chest wall displacements induced over the range of axial displacement examined were as large as those normally accompanying a change in lung volume on the order of 30-50% of the vital capacity. It is concluded, however, that although this additional degree of freedom can cause large chest wall displacements, it probably cannot independently change lung volume. This implies that the system is constrained so that there are only a limited number of independent modes of chest wall movement that are capable of producing significant changes in lung volume. It also suggests that the system is constructed so that lung volume can be relatively independent of certain postural distortions of the chest wall.

Humans↗

An eight-degree-of-freedom quantum dynamics study for the H2+C2H system.

An eight-degree-of-freedom (8DOF) time-dependent wave-packet approach has been developed to study the H(2)+C(2)H-->H+C(2)H(2) reaction system. The 8DOF model is obtained by fixing one of the Jacobi torsion angle in the nine-degree-of-freedom AB+CDE reaction system. This study is an extension of the previous seven-degree-of-freedom (7DOF) computation [J. Chem. Phys. 119, 12057 (2003)] of this reaction system. This study shows that vibrational excitations of H(2) enhance the reaction probability, whereas the stretching vibrational excitations of C(2)H have only a small effect on the reactivity. Furthermore, the bending excitation of C(2)H, compared to the ground-state reaction probability, hinders the reactivity. A comparison of the rate constant between the 7DOF calculation and the present 8DOF results has been made. The theoretical and experimental results agree with each other very well when the present 8DOF results are adjusted to account for the lower transition state barrier heights found in recent ab initio calculations.

Journal Article↗

Driven electron transfer in an environment with slow and fast degrees of freedom.

Driven electron transfer in a polar medium with slow and fast degrees of freedom is studied in the framework of a spin-boson Hamiltonian. Evolution dynamics is rigorously found when omega(s)(c)/(Gamma(a))sqrt[E(rs)/kT]<<1, where omega(s)(c) is the Debye cutoff frequency in the spectral function for the slow modes, E(rs) is the reorganization energy of slow degrees of freedom, and Gamma(-1)(a) is the reaction time dependent on the laser intensity parameter a=muE(0)/Planck's over 2piomega. Here omega and E0 are the frequency and the amplitude of a cw electric field, and mu is the electron dipole moment difference between the initial and final states. The master equation is derived for an arbitrary driving force affecting both the transition matrix element and the potential energy. For a cw electric field, the time dependent probability of staying at the product state, P1(t), is shown to be strongly dependent on the field intensity parameter a: P1(a,t) approximately (Gamma(m(1),m(2))t)(-E(rf)/E(rs)) or P1(a,t) approximately (Gamma(m(0))t)(-E(rf)/E(rs)), double or single resonances, respectively. Here E(rf) is the reorganization energy of fast degrees of freedom, Gamma(m(1),m(2)) approximately J(2)(m(1))(a)+J(2)(m(2))(a), and Gamma(m(0)) approximately J(2)(m(0))(a), where J(a) is a Bessel function. By changing the parameter a, one is able to manipulate the rate and direction of the reaction. When J(2)(m(0))(a) is close to zero the reaction is slow. Hence, slow modes turn out to be fast. This changes the character of the evolution dynamics from non- to mono- exponential decay, respectively. For the double resonance, the equilibrium constant is studied with the field intensity. It is shown that the reaction is almost insensitive to temperature. However, it strongly depends on the reaction heat, which provides a condition for the resonance.

Journal Article↗

Flexibility and repeatability of finger movements during typing: analysis of multiple degrees of freedom.

The kinematics of the hand and fingers were studied during various keystrokes in typing. These movements were defined by 17 degrees of freedom of motion, and methods were developed to identify simplifying strategies in the execution of the task. Most of the analysis was restricted to the 11 degrees of freedom of the fingers, neglecting thumb and wrist motion. Temporal characteristics of the motion were defined by computing principal components, and it was found that only a few (two to four) principal components were needed to characterize motion of each of the degrees of freedom. Hierarchical relationships among patterns within and between different degrees of freedom were identified using cluster analysis. There was a considerable amount of consistency each time a given keystroke was executed by a subject, and this repeatability may imply a reduction in the number of degrees of freedom independently controlled by the nervous system. However, there also appears to be considerable flexibility in the coordination of the many joints of the hand when examined across different keys and across different subjects.

Biomechanical Phenomena↗

Using collision-induced dissociation with corrections for the ion number of degrees of freedom for quick comparisons of relative bonding strength.

The number of degrees of freedom-dependent stability of ions and ion-neutral non-covalent complexes under collision-induced dissociation (CID) conditions was studied in a quadrupole ion trap mass spectrometer. It was found that the stability of ions as probed by energy-variable CID has a linear dependence on the total number of degrees of freedom for the ions (or ion-neutral complexes) with the same (or nearly the same) bonding energy. The slope of such a stability vs number of degrees of freedom dependence correlates with the binding energy. Proton-bound amine dimers display the lowest slope as they have weak bonds. Breaking covalent bonds will result in much greater slopes. In addition to the binding energy, the vibrational frequencies of the ion also affect the stability vs number of degrees of freedom behavior. Studying such a dependence of the CID stability in a system paves the way for direct relative binding energy comparisons. The application of this approach is demonstrated by testing the relative heme affinities of anti-malaria drugs and related compounds.

Amines↗

On chaotic dynamics in "pseudobilliard" Hamiltonian systems with two degrees of freedom.

A new class of Hamiltonian dynamical systems with two degrees of freedom is studied, for which the Hamiltonian function is a linear form with respect to moduli of both momenta. For different potentials such systems can be either completely integrable or behave just as normal nonintegrable Hamiltonian systems with two degrees of freedom: one observes many of the phenomena characteristic of the latter ones, such as a breakdown of invariant tori as soon as the integrability is violated; a formation of stochastic layers around destroyed separatrices; bifurcations of periodic orbits, etc. At the same time, the equations of motion are simply integrated on subsequent adjacent time intervals, as in billiard systems; i.e., all the trajectories can be calculated explicitly: Given an initial data, the state of the system is uniquely determined for any moment. This feature of systems in interest makes them very attractive models for a study of nonlinear phenomena in finite-dimensional Hamiltonian systems. A simple representative model of this class (a model with quadratic potential), whose dynamics is typical, is studied in detail. (c) 1997 American Institute of Physics.

Journal Article↗