PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “electroporation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Highly efficient gene delivery by mRNA electroporation in human hematopoietic cells: superiority to lipofection and passive pulsing of mRNA and to electroporation of plasmid cDNA for tumor antigen loading of dendritic cells.

Designing effective strategies to load human dendritic cells (DCs) with tumor antigens is a challenging approach for DC-based tumor vaccines. Here, a cytoplasmic expression system based on mRNA electroporation to efficiently introduce tumor antigens into DCs is described. Preliminary experiments in K562 cells using an enhanced green fluorescent protein (EGFP) reporter gene revealed that mRNA electroporation as compared with plasmid DNA electroporation showed a markedly improved transfection efficiency (89% versus 40% EGFP(+) cells, respectively) and induced a strikingly lower cell toxicity (15% death rate with mRNA versus 51% with plasmid DNA). Next, mRNA electroporation was applied for nonviral transfection of different types of human DCs, including monocyte-derived DCs (Mo-DCs), CD34(+) progenitor-derived DCs (34-DCs) and Langerhans cells (34-LCs). High-level transgene expression by mRNA electroporation was obtained in more than 50% of all DC types. mRNA-electroporated DCs retained their phenotype and maturational potential. Importantly, DCs electroporated with mRNA-encoding Melan-A strongly activated a Melan-A-specific cytotoxic T lymphocyte (CTL) clone in an HLA-restricted manner and were superior to mRNA-lipofected or -pulsed DCs. Optimal stimulation of the CTL occurred when Mo-DCs underwent maturation following mRNA transfection. Strikingly, a nonspecific stimulation of CTL was observed when DCs were transfected with plasmid DNA. The data clearly demonstrate that Mo-DCs electroporated with mRNA efficiently present functional antigenic peptides to cytotoxic T cells. Therefore, electroporation of mRNA-encoding tumor antigens is a powerful technique to charge human dendritic cells with tumor antigens and could serve applications in future DC-based tumor vaccines.

Antigen Presentation↗

Electroporation can cause artefacts due to solubilization of cations from the electrode plates. Aluminum ions enhance conversion of inositol 1,3,4,5-tetrakisphosphate into inositol 1,4,5-trisphosphate in electroporated L1210 cells.

1. In electroporated L1210 cells, Ins(1,3,4,5)P4 causes Ca2+ release, owing to its conversion into Ins(1,4,5)P3, but this does not happen in cells permeabilized by digitonin treatment [Cullen, Irvine, Drøbak & Dawson (1989) Biochem. J. 259, 931-933]. 2. If the assay medium is subjected to electroporation by using a commercially available electroporation apparatus and then the cells are added and permeabilized with digitonin, the cells behave as if they had been electroporated. 3. Electroporation causes the release of high concentrations of Al3+ into the experimental medium, and addition of these concentrations of Al3+ into the experimental medium mimics the effect of electroporation on the conversion of Ins(1,3,4,5)P4 into Ins(1,4,5)P3. 4. It is concluded that the difference between electroporated and digitonin-permeabilized L1210 cells in this experimental system can be attributed to dissolution of Al3+ from the electroporation cuvette. Al3+ contamination may thus be a serious problem when using this apparatus.

Aluminum↗

Transdermal drug delivery using electroporation. II. Factors influencing skin reversibility in electroporative delivery of terazosin hydrochloride in hairless rats.

A previous study indicated that the parameters governing the performance of electroporative delivery to the skin, are voltage, pulse length, number of pulses and electrode area.1 This article describes a study in which the reversibility of the electroporation technique is evaluated with in vitro methods. The skin's reversal from an enhanced permeation mode as a result of electroporation to the base level was used as an index to understand the mechanism of drug delivery and also as a preliminary indicator of safety. Maximum delivery of the model drug, terazosin hydrochloride, occurred during the pulsing. Electroporative delivery with a wire electrode (small-area electrode, 0.56 cm(2)) using 20 pulses at U(skin,0) 88 V, and pulse length 20 ms, did not cause any damage to the skin. Increasing the pulse length to 60 ms, while keeping the rest of the parameters fixed, caused a visible change in the external appearance of the skin. However, with the use of a spiral electrode (large-area electrode, 2.74 cm(2)) at 60-ms pulse length, there was minimal damage to the skin. This may be attributed to the more uniform flow of current over the whole skin area. The large-area electrode required a smaller electrode voltage, U(electrode,0) for any given U(skin,0) and also delivered nearly double the instantaneous power density compared with the small-area electrode. These findings indicate that using shorter pulses and large-area electrodes is a safer technique than large pulses and small-area electrodes when electroporation is used to enhance skin's permeability for drug delivery.

Administration, Cutaneous↗

Electroporation and electrophoretic DNA transfer into cells. The effect of DNA interaction with electropores.

It has been shown recently that electrically induced DNA transfer into cells is a fast vectorial process with the same direction as DNA electrophoresis in an external electric field (Klenchin, V. A., S. I. Sukharev, S. M. Serov, L. V. Chernomordik, and Y. A. Chizmadzhev. 1991. Biophys. J. 60:804-811). Here we describe the effect of DNA interaction with membrane electropores and provide additional evidences for the key role of DNA electrophoresis in cell electrotransfection. The assay of electrically induced uptake of fluorescent dextrans (FDs) by cells shows that the presence of DNA in the medium during electroporation leads to a sharp increase in membrane permeability to FDs of M(r) < 20,000. The permeability increases with DNA concentration and the effect is seen even if FD is added to the cell suspension a few minutes after pulse application. The longer the DNA fragment, the greater the increase in permeability. The use of a two-pulse technique allows us to separate two effects provided by a pulsed electric field: membrane electroporation and DNA electrophoresis. The first pulse (6 kV/cm, 10 microseconds) creates pores efficiently, whereas transfection efficiency (TE) is low. The second pulse of much lower amplitude, but substantially longer (0.2 kV/cm, 10 ms), does not cause poration and transfection by itself but enhances TE by about one order of magnitude. In two-pulse experiments, TE rises monotonously with the increase of the second pulse duration. By varying the delay duration between the two pulses, we estimate the lifetime of electropores (which are DNA-permeable in conditions of low electric field) as tens of seconds. The data suggest that the mechanism of cell electrotransfection is underlain by electrophoretic movement of DNA through membrane pores, the size of which is determined by interaction with DNA in an electric field.

Animals↗

Effect of electroporation on the electroosmosis across hairless mouse skin in vitro.

The effect of electroporation on the iontophoresis-produced electroosmosis across the skin was evaluated by measuring the permeability of hairless mouse skin, to mannitol, a non-electrolyte, in vitro. Immediately after electroporation by squared pulses (10 times/s) at 100, 150 or 200 V for 1 ms, anodal iontophoretic permeations were determined at 0.4 mA/cm2 for 4 h. The observed iontophoretic permeability of mannitol was higher with electroporation pretreatment than without pretreatment. The enhanced flux of mannitol induced by electroporation, however, was due to increased passive diffusion. The contribution of convective or osmotic flow caused by anodal iontophoresis on skin permeation of mannitol was decreased by the pretreatment. In addition, osmotic flow was decreased with an increase in the applied voltage for electroporation. In contrast, mannitol flux during cathodal iontophoresis at 0.4 mA/cm2 after 150 or 200 V electroporation was higher than without electroporation as well as anodal iontophoresis, but cathodal iontophoretic flux after electroporation was lower than without iontophoresis. The neutral high-molecular compound dextran rhodamine B was also used as a second model. Anodal iontophoresis alone did not increase skin permeability of the compound. However, electroporation pretreatment before anodal iontophoresis enhanced the skin permeation of dextran rhodamine B, which was due to increased osmotic flow induced by this combination. These results suggest that electroporation decreases the electroosmosis produced by iontophoresis, and that electroporation increases skin permeability to neutral low and high model compounds (mannitol and dextran rhodamine B) probably due to an enlarged permeation pathway. Thus, electroporation affects osmotic flow from the anode to cathode during iontophoresis. Therefore, one has to pay attention to the change in electroosmosis produced by iontophoresis for the combined use of electroporation and iontophoresis to attain a high skin-penetration enhancing effect.

Administration, Topical↗

Bleomycin--electrical pulse delivery: electroporation therapy-bleomycin--Genetronics; MedPulser-bleomycin--Genetronics.

Genetronics Biomedical is using its electroporation therapy technology to deliver bleomycin to tumour cells for the treatment of cancer. Genetronics have developed the MedPulser Electroporation Therapy System, which consists of an electrical pulse generator and disposable electrode applicators. The MedPulser system enables the delivery of large molecules into cells by briefly applying an electric field to the cell. This causes a transient permeability in the cell's outer membrane characterised by the appearance of pores across the membrane. After the field is discontinued, the pores close, trapping the therapeutic molecules inside the target cells. Genetronics is using the MedPulser System in conjunction with bleomycin, an antineoplastic antibiotic that binds to DNA causing strand scissions. Genetronics is seeking a licensing partner for the use of electroporation for the delivery of drugs in chemotherapy. In 1998, Genetronics entered a licensing and development agreement with Ethicon for electroporation and electrofusion. Under the terms of this agreement, Ethicon was to develop and clinically test the Genetronics electroporation delivery system and conduct all regulatory activities throughout the world except Canada. Ethicon would also market the products once regulatory approval has been obtained and Genetronics was to receive a percentage of the net sales and as license fees. However, in July 2000, Ethicon exercised its rights to terminate the agreement without cause. All rights were returned to Genetronics in January 2001. In 1997, Genetronics entered an agreement with Abbott Laboratories for the manufacture of bleomycin for use in the US in its MedPulsar system after regulatory approval had been granted for its use in the treatment of solid tumours. In a separate supply agreement, Faulding Inc. has agreed to manufacture bleomycin for Genetronic for use in Canada after regulatory approval had been granted. The MedPulsar Electroporation Therapy System with bleomycin is currently in phase III pivotal studies in the US as a treatment for recurrent and second primary squamous cell carcinomas of the head and neck. Genetronics received approval for the Electroporation Therapy system as a device in March 1999 when it achieved CE Mark certification. In February 2004, Genetronics announced that it had completed a Special Protocol Assessment review process with the US FDA for two new trials that will compare bleomycin electroporation therapy to surgery. The primary endpoint will be tissue and function preservation rather than survival. One proposal is for recurrent head and neck cancer, and the other is for disfiguring cutaneous cancer. Three Institutional Review Boards in the US have approved the two protocols and Genetronics has initiated enrollment. In June 2004, Genetronics was granted fast-track status for its MedPulsar Electroporation Therapy System clinical development programme for patients with head and neck cancer. Shifting from a primary endpoint of survival to a quality-of-life outcome will enable those clinical trials to be carried out faster with less cost and with a higher likelihood of success. As a result, Genetronic's phase III trials focussing on survival as a primary endpoint have been discontinued. This includes a phase III trial for late-stage, recurrent head and neck cancer in combination with the normal standard of treatment compared with normal standard of treatment alone. Interim results from this trial had suggested bleomycin electroporation therapy demonstrated local tumour control and preservation of organ function, as well as non-inferiority when compared with surgery. This trial was initiated in May 2002. In March 2004, Genetronics initiated a post-European regulatory approval clinical study in patients with primary or recurrent squamous cell carcinoma of the head and neck (SCCHN). This study aims to enroll approximately 100 patients at 12-15 hospitals located in the UK, Germany, Italy, France, Austria and other western European countries. The study is designed to support the commercialisation of the MedPulser Electroporation System in the EU. Prior clinical trials established the safety and performance of the MedPulser System for the treatment of SCCHN, leading to approval for sale in the EU based on achieving the CE Mark. This study will document the clinical and pharmacoeconomic benefit in support of reimbursement approval throughout Western Europe, establish centres of excellence to facilitate early sales, create a reference and customer base for a projected European commercial launch in 2005, and generate safety and efficacy data to support marketing applications in the US. The bleomycin delivery system has completed phase IIB trials in the US, Canada and Europe in patients with squamous cell carcinoma of the head and neck who have failed conventional therapies. Phase II data were submitted to the FDA in the first quarter of 2002 and a phase III trial was launched in May 2002. The therapy is also being used in France in patients with cancers of the head and neck, liver (metastatic) and melanoma. A review of the data from these phase II trials was completed in April 2001. In June 2004, Genetronics was granted two US patents. US patent 6,748,265 covers its trans-surface drug and gene delivery technology and provides additional proprietary rights for an apparatus and method to deliver genes, drugs and other molecules through tissue surfaces. The second US patent, 6,746,441, pertains to the field of ex vivo therapies and covers the introduction of molecules into cells by electroporation, either in a continuous-flow or batch mode, with a variable electric field orientation. In July 2004, Genetronics received a US patent (no. 6,763,264) covering methods for the in vivo delivery of a recombinant expression vector (DNA) or a pharmaceutical agent into tissue cells, and a method for the therapeutic application of electroporation to a patient to introduce macromolecules.

Antibiotics, Antineoplastic↗

Lipid and electroosmosis enhanced transdermal delivery of insulin by electroporation.

Transdermal transport of insulin and extraction of interstitial glucose under anodal iontophoresis (electroosmosis) following electroporation in the presence of 1,2-dimyristoylphophatidylserine (DMPS) was studied. An earlier study showed that DMPS increased the transport of insulin across porcine epidermis under electroporation by approximately fourfold. It was suggested that DMPS increased the lifetime of electropores in the epidermis resulting in an enhanced transport of permeants. When electroosmosis was applied across the epidermis following electroporation with DMPS, the enhancement of insulin transport was approximately 18-fold over electroporation alone. When the same strategy was applied to extract interstitial glucose, the enhancement was approximately 23-fold over electroporation alone. Real-time transdermal insulin transport kinetics was measured using FITC-labeled insulin and a custom-made vertical diffusion apparatus that had a fluorescence cuvette as the receiver compartment. Insulin transport by electroporation alone showed a nonlinear kinetics that is most likely due to the resealing of the electropores with time. The transport kinetics when electroporation was carried out in the presence of DMPS was more linear, confirming earlier studies that suggested the DMPS stabilizes transport paths formed by electroporation. The data suggests that in vivo, noninvasive insulin delivery to therapeutic levels and glucose extraction may be achieved by combining electroporation with anionic lipids and electroosmosis.

Administration, Cutaneous↗

Skin targeted DNA vaccine delivery using electroporation in rabbits II. Safety.

The Achilles heel of gene-based therapy is gene delivery into the target cells efficiently with minimal toxic effects. Viral vectors for gene/DNA vaccine delivery are limited by the safety and immunological problems. Recently, nonviral gene delivery mediated by electroporation has been shown to be efficient in different tissues including skin. There are no detailed reports about the effects of electroporation on skin tissue, when used for gene/DNA vaccine delivery. In a previous study we demonstrated the efficacy of skin targeted DNA vaccine delivery using electroporation in rabbits [Medi, B.M., Hoselton, S., Marepalli, B.R., Singh, J., 2005. Skin targeted DNA vaccine delivery using electroporation in rabbits. I. Efficacy. Int. J. Pharm. 294, 53-63]. In the present study, we investigated the safety aspects of the electroporation technique in vivo in rabbits. Different electroporation parameters (100-300 V) were tested for their effects on skin viability, macroscopic barrier property, irritation and microscopic changes in the skin. Skin viability was not affected by the electroporation protocols tested. The electroporation pulses induced skin barrier perturbation and irritation as indicated by elevated transepidermal water loss (TEWL) and erythema/edema, respectively. Microscopic studies revealed inflammatory responses in the epidermis following electroporation using 200 and 300 V pulses. However, these changes due to electroporation were reversible within a week. The results suggest that the electroporation does not induce any irreversible changes in the skin and can be a useful technique for skin targeted DNA vaccine delivery.

Animals↗

Effects of electroporation on primary rat hepatocytes in vitro.

AIM: To investigate the effects of electroporation on primary rat hepatocyte and to optimize the electroporation conditions introducing foreign genes into primary hepatocytes. METHODS: A single-pulse procedure was performed at low voltage (220-400 V) but with high capacitance (500-950 microF). Hepatocytes were divided into 4 groups according to the electroporation conditions: group I, 220 V and 500 microF; group II, 220 V and 950 microF; group III, 400 V and 950 microF,and group IV. The control group was freshly isolated hepatocytes and directly cultured under the same conditions as those of electroporation groups. The effects of electroporation on primary rat hepatocytes were detected by trypan blue exclusion (TBE) and MTT analysis. Besides, albumin (Alb), alanine transaminase (ALT) and lactate dehydrogenase (LDH) in the supernatants of cultured hepatocytes were measured by biochemical assay. RESULTS: Between day 1 and day 15 after incubation, primary rat hepatocytes of each electroporation group appeared normal, being the same with those of control group. TBE staining showed that slight hepatocyte damage and high survival rate were found in the electroporation groups and the control group. Cultured for 3, 7, 11 and 15 days, hepatocyte viability was approximately 92.6+/-2.5 %, 89.5+/-3.3 %, 82.0+/-3.5 % and 74.3+/-1.2 %, respectively. MTT analysis indicated that the viabilities of hepatocytes had no significant difference between each electroporation group, and those were similar to that of control group. At the 36th hour after electroporation, Alb, ALT and LDH in the supernatants of control group were 5.3+/-0.1 g x L(-1), 183.7+/-8.4 nkat x L(-1) and 896.8+/-58.5 nkat x L(-1); those of group II were 5.7+/-0.1 g x L(-1), 215.4+/-16.7 nkat x L(-1) and 1063.8+/-51.8 nkat x L(-1); and those of group III were 5.8+/-0.2 g x L(-1), 217.1+/-8.4 nkat x L(-1) and 1063.8+/-10.0 nkat x L(-1). Statistically, the proteins of group II and group III were significantly higher than those of control group (P<0.05), whereas the protein production of group I, Alb, ALT and LDH were 5.3+/-0.2 g x L(-1), 205.4+/-3.3 nkat x L(-1) and 1035.4+/-116.9 nkat x L(-1), were similar to those of control group. At the same time, TBE and MTT analysis indicated that there was no significant cell viability difference between electroporation groups and control group. CONCLUSION: This single-pulse electroporation procedure performed at low voltage (220-400 V) but with high capacitance (950 microF) is one of the optimal choices to introduce foreign genes into primary rat hepatocyte.

Animals↗

Tc-99m pyrophosphate imaging of poloxamer-treated electroporated skeletal muscle in an in vivo rat model.

OBJECTIVE: This study investigates whether (99m)Tc pyrophosphate (PYP) imaging provides a quantitative non-invasive assessment of the extent of electroporation injury, and of the effect of poloxamer in vivo on electroporated skeletal muscle. METHODS: High-voltage electrical shock was used to produce electroporation injury in an anesthetized rat's hind limb. In each experiment, the injured limb was treated intravenously by either poloxamer-188, dextran, or saline, and subsequently imaged with (99m)Tc PYP. The radiotracer's temporal behavior among the experimental groups was compared using curve fitting of time-activity curves from the dynamic image data. RESULTS: The washout kinetics of (99m)Tc PYP changed in proportion to the electric current magnitude that produced electroporation. Also, (99m)Tc PYP washout from electroporated muscle differed between poloxamer-188 treatment and saline treatment. Finally, 10-kDa dextran treatment of electroporated muscle altered (99m)Tc PYP washout less than poloxamer-188 treatment. CONCLUSIONS: Behavior of (99m)Tc PYP in electroporated muscle appears to be an indicator of the amount of electroporation injury. Compared to saline, intravenous polaxamer-188 treatment reduced the amount of (99m)Tc PYP uptake. Coupled to results showing poloxamer-188 seals ruptured cellular membranes, lessens the extent of electroporation injury and improves cell viability, (99m)Tc PYP imaging appears to be a useful in vivo monitoring tool for the extent of electroporation injury.

Animals↗

Improved intracellular delivery of oligonucleotides by square wave electroporation.

Prior studies have shown that electroporation is a simple and effective method for the introduction of oligonucleotides (ODN) into cells. In ex vivo bone marrow purging models, electroporation of ODN into cells has been associated with selective killing of human neoplastic cells while sparing hematopoietic stem cells. Prior studies used conventional electroporation methods (i.e., exponential decay) to introduce ODN into cells. Square wave electroporation allows the delivery of a more defined and regulated electrical pulse and is associated with high transfection efficiencies in a variety of systems. The current study was undertaken to determine whether square wave electroporation was more effective than exponential decay electroporation for the delivery of ODN into hematopoietic cells. Using fluorescein-tagged ODN and K562, chronic myelogenous leukemia (CML) cells, higher transfection rates were observed after square wave electroporation. In addition, c-myc antisense ODN were more effective in reducing c-myc protein when introduced by square wave electroporation, as compared with introduction by exponential decay electroporation. Square wave electroporation is thus identified as the optimal method for delivering ODN into hematopoietic cells.

Base Sequence↗

Effects of electroporation on the transmembrane potential distribution in a two-dimensional bidomain model of cardiac tissue.

INTRODUCTION: Defibrillation shocks, when delivered through internal electrodes, establish transmembrane potentials (Vm) large enough to electroporate the membrane of cardiac cells. The effects of such shocks on the transmembrane potential distribution are investigated in a two-dimensional rectangular sheet of cardiac muscle modeled as a bidomain with unequal anisotropy ratios. METHODS AND RESULTS: The membrane is represented by a capacitance Cm, a leakage conductance g(l) and a variable electroporation conductance G, whose rate of growth depends exponentially on the square of Vm. The stimulating current Io, 0.05-20 A/m, is delivered through a pair of electrodes placed 2 cm apart for stimulation along fibers and 1 cm apart for stimulation across fibers. Computer simulations reveal three categories of response to Io: (1) Weak Io, below 0.2 A/m, cause essentially no electroporation, and Vm increases proportionally to Io. (2) Strong Io, between 0.2 and 2.5 A/m, electroporate tissue under the physical electrode. Vm is no longer proportional to Io; in the electroporated region, the growth of Vm is halted and in the region of reversed polarity (virtual electrode), the growth of Vm is accelerated. (3) Very strong Io, above 2.5 A/m, electroporate tissue under the physical and the virtual electrodes. The growth of Vm in all electroporated regions is halted, and a further increase of Io increases both the extent of the electroporated regions and the electroporation conductance G. CONCLUSION: These results indicate that electroporation of the cardiac membrane plays an important role in the distribution of Vm induced by defibrillation strength shocks.

Anisotropy↗

The role of electroporation in defibrillation.

Electric shock is the only effective therapy against ventricular fibrillation. However, shocks are also known to cause electroporation of cell membranes. We sought to determine the impact of electroporation on ventricular conduction and defibrillation. We optically mapped electrical activity in coronary-perfused rabbit hearts during electric shocks (50 to 500 V). Electroporation was evident from transient depolarization, reduction of action potential amplitude, and upstroke dV/dt. Electroporation was voltage dependent and significantly more pronounced at the endocardium versus the epicardium, with thresholds of 229+/-81 versus 318+/-84 V, respectively (P=0.01, n=10), both being above the defibrillation threshold of 181.3+/-45.8 V. Epicardial electroporation was localized to a small area near the electrode, whereas endocardial electroporation was observed at the bundles and trabeculas throughout the entire endocardium. Higher-resolution imaging revealed that papillary muscles (n=10) were most affected. Electroporation and conduction block thresholds in papillary muscles were 281+/-64 V and 380+/-79 V, respectively. We observed no arrhythmia in association with electroporation. Further, preconditioning with high-energy shocks prevented reinduction of fibrillation by 50-V shocks, which were otherwise proarrhythmic. Endocardial bundles are the most susceptible to electroporation and the resulting conduction impairment. Electroporation is not associated with proarrhythmic effects and is associated with a reduction of vulnerability.

Action Potentials↗

Digression on membrane electroporation for drug and gene delivery.

Membrane electroporation (ME) defines an electrical technique to render lipid membranes porous and permeable, transiently and reversibly, by external voltage pulses. Although there are numerous applications of ME to manipulate cells, organelles and tissues in cell biology, biotechnology and medicine, yet the molecular mechanism of ME is only slowly being understood. A general chemical- thermodynamical approach for the quantitative description of cell membrane electroporation has been developed to provide the framework to quantitatively rationalize electroporative cell transformation and electroporative uptake of drug-like dyes into cells, as well as electrolyte efflux from salt-filled electroporated vesicles. Mechanistically, the electroporative transfer of gene and drug-like dyes involves the coupling between an interactive contact formation of the permeates with the cell surface membrane and the structural electroporation-resealing cycle C <--> (P) where C is the closed and (P) represents a number of different porated membrane states, respectively. The experimentally accessible concentration fraction f(p) = [(P)] / ([C] + [(P)]) of porous states is related to thermodynamic and electro-mechanic parameters such as temperature and the electric field strength, membrane rigidity or curvature. The results of the theoretical approach, mainly based on electrooptical data of lipid vesicles, have been successfully used to analyze single cells and to specify conditions for the practical purpose of direct electroporative gene transfer and drug delivery, in particular in the new medical disciplines of electroporative chemotherapy and electroporative gene vaccination.

Animals↗

Biomaterial-Integrated Electroporation for Therapeutic Delivery: From Gene Editing to Tumor Ablation and Immune Modulation.

Electroporation has evolved from a membrane-permeabilization method into a versatile therapeutic platform for intracellular delivery, locoregional tumor intervention, and bioelectrically regulated treatment. Depending on pulse intensity and duration, electroporation operates in two distinct modes: reversible electroporation (RE), which transiently permeabilizes the plasma membrane to enable delivery of nucleic acids, proteins, and small molecules while preserving cell viability, and irreversible electroporation (IRE), which causes permanent membrane damage for non-thermal tissue ablation. Increasingly, the therapeutic scope of electroporation is being expanded through integration with biomaterials, including nanocarriers, hydrogels, soft conductors, and micro/nanoengineered bioelectronic interfaces. These material-assisted strategies improve cargo protection, field confinement, local retention, tissue conformity, and spatiotemporal control, thereby extending electroporation beyond conventional transfection toward gene editing, engineered cell manufacturing, electrochemotherapy, tumor ablation, immune modulation, and transdermal or localized delivery. In this Review, we summarize the biophysical principles of RE and IRE, discuss how biomaterials reshape electroporation performance across therapeutic settings, compare the design logic of major biomaterial-assisted electroporation platforms, and highlight key translational challenges, including pulse-material compatibility, manufacturing scalability, in vivo dosimetry, and regulatory complexity.

Humans↗

Electroporation-facilitated delivery of plasmid DNA in skeletal muscle: plasmid dependence of muscle damage and effect of poloxamer 188.

Electroporation has been reported to facilitate naked DNA gene transfer in skeletal muscle, but has also been implicated in the pathogenesis of electrical injuries. To assess the effects of electroporation on gene transfer, mouse quadriceps muscles were injected with the luciferase reporter plasmid VR1255 and electroporated with caliper electrodes. Intramuscular luciferase expression was increased 10- to 70-fold by electroporation, depending on the DNA dose and injection volume used. In the absence of plasmid DNA injection, electroporation of quadriceps muscles resulted in rapid elevations in serum creatine phosphokinase activity, but did not elicit visible muscle damage. However, in muscles injected with plasmid DNA and electroporated, visible lesions consistently developed in the areas proximal to electrode placement when field strengths optimal for gene transfer (300 volts/cm) were applied. The development of muscle lesions was independent of plasmid transgene expression and required the presence of plasmid in the muscle during electroporation. Co-injection of poloxamer 188 (pluronic F68) with VR1255 substantially reduced elevations in serum creatine phosphokinase activity following electroporation, but did not inhibit the development of muscle lesions. In non-electroporated muscles, co-injection of poloxamer 188 increased luciferase expression threefold. Poloxamer 188 may thus constitute a useful excipient for intramuscular delivery of naked DNA.

Animals↗

Dendritic cells loaded with exogenous antigen by electroporation can enhance MHC class I-mediated antitumor immunity.

To develop an efficient antitumor immunotherapy, we have examined if dendritic cells (DCs) loaded with soluble antigens by electroporation present more antigens via the MHC (major histocompatibility complex) class I pathway, which mediate a cytotoxic T-cell response. DCs loaded with ovalbumin (OVA) by electroporation presented more MHC class I-restricted determinants compared with DCs pulsed with OVA. When electroporated DCs were pulsed with OVA for additional times, both MHC class I- and II-restricted presentation of OVA were increased compared with each single procedure, including electroporation or simple pulse. Immunization with DCs loaded with OVA by electroporation induced higher cytotoxicity of splenocytes to E.G7 cells, a clone of EL4 cells transfected with an OVA cDNA, than immunization with DCs pulsed with OVA. In the animal study, immunization with DCs loaded with OVA or tumor cell lysates by electroporation induced an effective antitumor immunity against tumor of E.G7 cells or Lewis lung carcinoma cells, respectively. In addition, immunization with DCs loaded with antigen by combination of electroporation and pulse, completely protected mice from tumor formation, and prolonged survival, in both tumor models. These results demonstrated that electroporation would be a useful way to enhance MHC class I-mediated antitumor immunity without functional deterioration, and that the combination of electroporation and pulse could be a simple and efficient antigen-loading method and consequently lead to induction of strong antitumor immunity.

Animals↗