PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ion charge state”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Dissociation of multiple protein ion charge states following a single gas-phase purification and concentration procedure.

The formation of a range of precursor ion charge states from a single concentrated and purified charge state, followed by activation of each charge state, is introduced as a means to obtain more protein structural information than is available from dissociation of a single charge state alone. This approach is illustrated using off-resonance collisional activation of the [M + 8H]8+ to [M + 6H]6+ precursor ions of the bacteriophage MS2 viral coat protein following concentration and purification of the [M + 8H]8+ charge state. This range of charge states was selected on the basis of an ion trap collisional activation study of the effects of precursor ion charge state on the dissociation of the [M + 12H]12+ to [M + 5H]5+ ions. Gas-phase ion/ion proton-transfer reactions and the ion parking technique were applied to purify and concentrate selected precursor ion charge states as well as to simplify the product ion spectra. The high-charge-state ions fragment preferentially at the N-terminal side of proline residues while the product ion spectra of the lowest charge states investigated are dominated by C-terminal aspartic acid cleavages. Maximum structural information is obtained by fragmentation of the intermediate-charge states.

Amino Acid Sequence↗

Determination of peptide and protein ion charge states by Fourier transformation of isotope-resolved mass spectra.

We report an automated method for determining charge states from high-resolution mass spectra. Fourier transforms of isotope packets from high-resolution mass spectra are compared to Fourier transforms of modeled isotopic peak packets for a range of charge states. The charge state for the experimental ion packet is determined by the model isotope packet that yields the best match in the comparison of the Fourier transforms. This strategy is demonstrated for determining peptide ion charge states from "zoom scan" data from a linear quadrupole ion trap mass spectrometer, enabling the subsequent automated identification of singly- through quadruply-charged peptide ions, while reducing the numbers of conflicting identifications from ambiguous charge state assignments. We also apply this technique to determine the charges of intact protein ions from LC-FTICR data, demonstrating that it is more sensitive under these experimental conditions than two existing algorithms. The strategy outlined in this paper should be generally applicable to mass spectra obtained from any instrument capable of isotopic resolution.

Algorithms↗

Suppression of the lower charge state ions in the external accumulation RF multipole with a reduced trapping DC potential.

Radio frequency (RF) multipoles are increasingly used in mass spectrometry as two-dimensional ion traps for ion accumulation and preselection. It was reported recently that ions having lower charge states, in particular singly charged ions, can be efficiently removed from such an ion trap when reduced DC trapping voltages are applied. This procedure can be useful for removing singly charged species contributing chemical noise to mass spectra of complex biomolecular samples, e.g., solvent contaminants in LC-MS or relatively low MW ampholytes in CIEF-MS experiments. We consider a physical mechanism and derive relationships that provide a quantitative description for the low charge state ejection phenomenon. Experimental conditions for the efficient discrimination against lower charge states are evaluated. Initial experimental observations reported are in agreement with the theoretical treatment.

Journal Article↗

Product ion charge state determination via ion/ion proton transfer reactions.

Proton transfer from protonated pyridine to product anions derived from quadrupole ion trap collisional activation of the triply charged anion of the oligonucleotide 5'-d(AAAA)-3' and the 6- charge state of oxidized bovine insulin A-chain is shown to be a rapid and effective way to determine product charge states. The reactions are carried out in a quadrupole ion trap as part of a procedure involving three stages of mass analysis. It is demonstrated that the reactions can be driven at rates sufficiently high to convert 30-80% of the initial product anion population to second generation products in 50-200 ms. The use of ion/ion reactions enjoys significant advantages over the use of ion/molecule proton transfer chemistry. For example, ion/ion reactions are more universal than ion/molecule reactions due to their greater exothermicity, and ion/ion reactions allow for precise control over the timing of introduction and ejection of each reactant. Despite the high exothermicity of the reactions, no significant fragmentation of product ions derived from high-mass multiply charged anions is observed.

Animals↗

Controlling charge states of large ions.

The charge state of ions produced in electrospray ionization (ESI) was reduced in a controlled manner to yield predominantly singly charged species by exposure of the aerosol to a bipolar ionizing gas. Analysis of the resulting ions on an orthogonal time-of-flight mass spectrometer yielded mass spectra greatly simplified compared with conventional ESI spectra. The decreased spectral complexity afforded by the charge reduction facilitates the analysis of mixtures by ESI mass spectrometry.

Aerosols↗

Analysis of macromolecules using nanoelectrospray ionization mass spectrometry and low-energy collision activation.

The mass spectrometric analysis of several proteins using nanoelectrospray (nanoES) with elastic collisions showed an improvement in the sensitivity over nanoES without collisional activation. We believe this effect is due to a better declusterization/ionization process. Optimization of the collision parameters can be easily performed during the long experiment time allowed using the nanoES source. Moreover, an apparent shift in the charge-state distribution is observed, with lower charged ions becoming relatively more abundant with increasing either target gas pressure or kinetic energy of the precursor ions. Higher charge-state ions might be expected to have higher collision frequencies and correspondingly lose more kinetic energy than lower charge-state ions.

Animals↗

'Top down' protein characterization via tandem mass spectrometry.

Technological and scientific advances over the past decade have enabled protein identification and characterization strategies to be developed that are based on subjecting intact protein ions and large protein fragments directly to tandem mass spectrometry. These approaches are referred to collectively as 'top down' to contrast them with 'bottom up' approaches whereby protein identification is based on mass spectrometric analysis of peptides derived from proteolytic digestion, usually with trypsin. A key step in enabling top down approaches has been the ability to assign tandem mass spectrometer product ion identities, which can be done either via high resolving power or through product ion charge state manipulation. The ability to determine product ion charge states has permitted studies of the reactions, including dissociation, ion-molecule reactions, ion-electron reactions and ion-ion reactions of high-mass, multiply charged protein ions. Electrospray ionization combined with high magnetic field strength Fourier transform ion cyclotron resonance has proven to be particularly powerful for detailed protein characterization owing to its high mass resolution and mass accuracy and its ability to effect electron capture-induced dissociation. Other types of tandem mass spectrometers are also beginning to find increasing use in top down protein identification/characterization studies. Charge state manipulation via ion-ion reactions in electrodynamic ion traps, for example, enables top down strategies to be considered using instruments with relatively modest mass resolution capabilities. Precursor ion charge state manipulation techniques have also recently been demonstrated to be capable of concentrating and charge-state purifying proteins in the gas phase. Advances in technologies applied to the structural analysis of whole protein ions and in understanding their reactions, such as those described here, are providing new options for the study of complex protein mixtures.

Amino Acid Sequence↗

Ion trap collisional activation of the (M + 2H)2+ - (M + 17H)17+ ions of human hemoglobin beta-chain.

The parent ions of human hemoglobin beta-chain ranging in charge from 2+ to 17+ have been subjected to ion trap collisional activation. The highest charge-state ions (17+ to 13+) yielded series of products arising from dissociation of adjacent residues. The intermediate charge-state ions (12+ to 5+) tended to fragment preferentially at the N-terminal sides of proline residues and the C-terminal sides of acidic residues. Many, but not all, of the possible cleavages at proline, aspartic acid, and glutamic acid residues were represented in the spectra. The lowest charge-state ions were difficult to dissociate with high efficiency and yielded spectra with poorly defined product ion signals. This observation is attributed to sequential fragmentations arising from losses of small molecules such as water and/or ammonia. The poor fragmentation efficiency observed for the low charge states is due at least in part to the low trapping wells used to store the ions. Higher ion stabilities due to lower Coulombic repulsion and charges being sequestered at highly basic sites may also play an important role. Ion/ion proton-transfer reactions involving protein parent ions allows for the formation of a wide range of parent ion charge states. In addition, the ion/ion proton-transfer reactions involving protein dissociation products simplify interpretation of the product ion spectra.

Amino Acid Sequence↗

Charge-state-dependent sequence analysis of protonated ubiquitin ions via ion trap tandem mass spectrometry.

One of the major factors governing the "top-down" sequence analysis of intact multiply protonated proteins by tandem mass spectrometry is the effect of the precursor ion charge state on the formation of product ions. To more fully understand this effect, electrospray ionization coupled to a quadrupole ion trap mass spectrometer, collision-induced dissociation, and gas-phase ion/ion reactions have been employed to examine the fragmentation of the [M + 12H]12+ to [M + H]+ ions of bovine ubiquitin. At low charge states (+1 to +6), loss of NH3 or H2O from the protonated precursor and directed cleavage at aspartic acid residues was observed. At intermediate charge states, (+7, +8, and +9), extensive nonspecific fragmentation of the protein backbone was observed, with 50% sequence coverage obtained from the [M + 8H]8+ ion alone. At high charge states, (+10, +11, +12), the single dominant channel that was observed was the preferential fragmentation of a single proline residue. These data can be readily explained in terms of the current model for intramolecular proton mobilization, that is, the "mobile proton model", the mechanisms for amide bond dissociation developed for protonated peptides, as well as the structures of the multiply charged ions of ubiquitin in the gas phase, examined by ion mobility and hydrogen/deuterium exchange measurements.

Amino Acid Sequence↗

Simplification of product ion spectra derived from multiply charged parent ions via ion/ion chemistry.

High-mass multiply charged ions fragment to yield a mixture of products of varying mass and charge. When the measurement of mass-to-charge ratio is used to determine products ion mass, product ion charge must first be established. To minimize charge-state ambiguity in product ion spectra derived from multiply charged parent ions, product ions have been subjected to proton-transfer reactions with oppositely charged ions to reduce product ion charge states largely to +1. This procedure greatly simplifies the interpretation of product ion spectra derived from multiply charged ions. Illustrative data are presented for the +4 and +3 parent ions derived from electrospray of melittin and the +12 to +4 parent ions of bovine ubiquitin, whereby product ions were formed in a conventional quadrupole ion trap tandem mass spectrometry experiment. Data are also shown for product ion mixtures derived from interface-induced dissociation of multiply charged ions derived from bovine ubiquitin, tuna cytochrome c, bovine cytochrome c, and equine cytochrome c. The use of ion/ion chemistry to simplify product ion spectra derived from multiply charged parent ions significantly extends the size range of macromolecules for which the quadrupole ion trap can derive structural information.

Amino Acid Sequence↗

Thermal decomposition of a gaseous multiprotein complex studied by blackbody infrared radiative dissociation. Investigating the origin of the asymmetric dissociation behavior.

The blackbody infrared radiative dissociation technique was used to study the thermal decomposition of the gaseous B5 pentamer of the Shiga-like toxin I and its complexes with the Pk trisaccharide and a decavalent Pk-based oligosaccharide ligand (STARFISH, S). Dissociation of the protonated pentamer, (B5 + nH)n+ triple bond B5n+ where n = 11-14, proceeds almost exclusively by the loss of a single subunit (B) with a disproportionately large fraction (30-50%) of the parent ion charge. The degree of charge enrichment of the leaving subunit increases with increasing parent ion charge state. For n = 12-14, a distribution of product ion charge states is observed. The yields of the complementary pairs of product ions are sensitive to the reaction temperature, with higher temperatures favoring greater charge enrichment of the leaving subunit for +13 and +14, and the opposite effect for +12. These results indicate that some of the protons are rapidly exchanged between subunits in the gas phase. Dissociation of B5(14+) x S proceeds exclusively by the loss of one subunit, although the ligand increases the stability of the complex and also reduces the degree of charge enrichment in the ejected monomer. For B5(12+)(Pk)1-3, the loss of neutral Pk competes with loss of a subunit at low temperatures. Linear Arrhenius plots were obtained from the temperature-dependent dissociation rate constants measured for the loss of B from B5n+ and B514+ x S. The magnitude of the Arrhenius parameters is highly dependent on the charge state of the pentamer: Ea = 35 kcal/mol and A = 1,019 s(-1) (+14), 46 kcal/mol and 1,023 S(-1) (+13), 50 kcal/mol and 1026 s(-1) (+12), and 80 kcal/mol and 10(39) (+11). The Ea and A for B5(14+) x S are 59 kcal/mol and 10(30) s(-1), respectively. The reaction pathways leading to greater charge enrichment of the subunit lost from the B5(14+) and B5(13+) ions correspond to higher energy processes, however, these pathways are kinetically preferred at higher temperatures due to their large A factors. A simple electrostatic model, whereby charge enrichment leads to Coulombic repulsion-induced denaturation of the subunits and disruption of the intersubunit interactions, provides an explanation for the magnitude of the Arrhenius parameters and the origin of the asymmetric dissociation behavior of the complexes.

Carbohydrate Sequence↗

Heme-peptide/protein ions and phosphorous ligands: search for site-specific addition reactions.

High-resolution Fourier transform ion cyclotron resonance mass spectrometry is employed to gain thorough kinetics and thermodynamics information on the reaction of free and ligated heme-type ions with selected ligands, with the aim of obtaining an insight into the coordination environment of the prosthetic group in a variety of biomolecular ions. Adopting a stepwise approach towards systems of increasing complexity, we examined the reactivity of free gaseous iron(III) protoporphyrin IX ions, Fe(III)-heme(+), of the charged species from microperoxidase-11 (MP11) (covalently peptide bound heme), and of the multiply charged ions from heme proteins, namely, cytochrome c (cyt c) and myoglobin (examples of noncovalently protein bound hemes). Among an array of test compounds allowed to react with Fe(III)-heme(+), OP(OMe)(3) and P(OMe)(3) proved to be similarly efficient ligands in the first addition step, yet displayed markedly distinct reactivity towards heme iron already engaged in axial coordination. The ease with which P(OMe)(3) acts as a second axial ligand is exploited to probe structural and conformational features of biomolecular ions. In this way, circumstantial evidence is gained of a folded conformation of +2 charge state ions from MP11 and an elongated one for the +3 charge state ions. Similarly, both the general reaction pattern and detailed kinetics and thermodynamics data point to a regiospecific addition reaction of P(OMe)(3) directed at the heme iron within multiply charged ions from cyt c. This unprecedented example of ion-molecule reaction which specifically involves a prosthetic group belonging to protein ions stands in contrast to the multiple, nonspecific interactions established by OP(OMe)(3) molecules with the protonated sites of multiply charged cyt c and apomyoglobin ions. This finding may develop and provide sensitive probes of the structure and bonding features of protein ions in the gas phase.

Animals↗

Oligonucleotide mixture analysis via electrospray and ion/ion reactions in a quadrupole ion trap.

Electrospray ionization combined with ion/ion reactions in a quadrupole ion trap can be used for the direct analysis of oligonucleotide mixtures. Elements to the success of this approach include factors related to ionization, ion/ion reactions, and mass analysis. This paper deals with issues regarding the ion polarity combination, viz., positive oligonucleotides/negative charge-transfer agent versus negative oligonucleotides/positive charge-transfer agent. Anions derived from perfluorocarbons appear to be directly applicable to mixtures of positive ions derived from electrospray of oligonucleotides, in direct analogy with positive protein ions. Conditions for forming positive oligonucleotide ions devoid of adducts were more difficult to establish than for forming relatively clean negative oligonucleotide ions. A new approach for manipulating negative ion charge states in the ion trap is described and is based on use of the electric field of the positive charge-transfer agent for storage of high-mass negative ions formed during the ion/ion reaction period. Oxygen cations are shown to be acceptable for charge-state manipulation of mixed-base oligomers but induce fragmentation in polyadenylate homopolymers. Protonated isobutylene (C4H9+), on the other hand, is shown to induce significantly less fragmentation of polyadenylate homopolymers.

Anions↗

Unfolding dynamics of a beta-sheet protein studied by mass spectrometry.

The unfolding dynamics of cellular retinoic acid-binding protein I (CRABP I), an 18 kDa predominantly beta-sheet protein, were studied by monitoring the hydrogen-deuterium (H-D) exchange reaction under various solution conditions. A bimodal charge state distribution was observed when a denaturing agent was added to the protein aqueous solution. These two populations exhibit different kinetics of H-D exchange, with the high charge state ions undergoing very rapid isotope exchange, while the low charge state protein ions exchange cooperatively but at much slower rates. Transiently populated intermediate states were detected indirectly using hydrogen exchange measurement in aqueous solution at various pHs. At pH 2.5 and room temperature, three distinct populations of CRABP I ions exist over an extended period of time, each corresponding to a specific degree of backbone amide hydrogen atom protection. Mass spectral data are complementary to hydrogen exchange measurements by NMR, since the former samples a much faster time-scale of dynamic events in solution.

Deuterium↗