PubMed HealthSearch

SEARCH · PubMed Health

Results for “soft-tissue implants”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2 recordsLinked to original sources

Influence of Concave Versus Convex Emergence Profiles on Midfacial Mucosal Stability-A Systematic Review With Meta-Analysis.

OBJECTIVES: To systematically evaluate the influence of concave versus convex emergence profiles on midfacial mucosal stability in partially edentulous patients restored with implant-supported single restorations. MATERIALS AND METHODS: A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted and registered in PROSPERO (CRD420251139042). An electronic search in MEDLINE (PubMed) and Embase was performed up to May 7, 2026. Eligible studies included RCTs comparing concave (test group) and convex (control group) transmucosal prosthetic designs and reporting midfacial mucosal level changes (mm). Data extraction and risk of bias assessment (RoB 2) were performed independently. A random-effects meta-analysis was conducted using weighted mean differences (MDs) and 95% confidence intervals (CIs). Heterogeneity was assessed using the I2 statistic and sensitivity analyses were performed to evaluate the robustness of the findings. RESULTS: Four RCTs including 144 implants with a 12-month follow-up were included. Of these, 128 implants contributed to the quantitative synthesis, with 66 implants allocated to the concave/modified emergence profile group and 62 implants allocated to the convex/non-concave emergence profile group. The pooled analysis demonstrated a mean difference of -0.31 mm (95% CI -0.63 to 0.02; p = 0.064), indicating a trend toward greater midfacial mucosal recession with convex emergence profiles compared with concave designs. Between-study heterogeneity was low to moderate (I2 = 28%), suggesting consistent findings across studies. Sensitivity analyses confirmed the direction of the effect, with pooled estimates ranging from -0.12 to -0.43 mm. Exclusion of one study resulted in a statistically significant difference favoring concave emergence profiles (-0.43 mm; 95% CI -0.70 to -0.16; p = 0.002). CONCLUSIONS: Convex emergence profiles are associated with a tendency toward increased midfacial mucosal recession. Concave profiles are preferable to support peri-implant soft-tissue stability. CLINICAL RELEVANCE: Emergence profile design should be considered an integral component of prosthetic and surgical planning. The use of concave transmucosal contours during provisionalization and definitive restoration may contribute to improved peri-implant soft tissue stability and enhanced esthetic outcomes.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper