PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “stationary phase”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

An assessment of the retention behaviour of polycyclic aromatic hydrocarbons on reversed phase stationary phases: selectivity and retention on C18 and phenyl-type surfaces.

In this manuscript the retention and selectivity of a set of linear and non-linear PAHs were evaluated on five different reversed-phase columns. These phases included C18 and C18 Aqua stationary phases, as well as three phenyl phases: Propyl-phenyl, Synergi polar-RP and Cosmosil 5PBB phase. Overall, the results revealed that the phenyl-type columns offered better separation performance for the linear PAHs, while the separation of the structural isomer PAHs was enhanced on the C18 columns. The Propyl-phenyl column was found to have the highest molecular-stationary phase interactions, as evidenced by the greatest rate of change in 'S' (0.71) as a function of the molecular weight in the PAH homologous series, despite having the lowest surface coverage (3% carbon load) (where S is the slope of a plot of logk versus the solvent composition). In contrast, the C18 Aqua column, having the highest surface coverage (15% carbon load) was found to have the second lowest molecular-stationary phase interactions (rate of change in S=0.61). Interestingly, the Synergi polar-RP column, which also is a phenyl stationary phase behaved more 'C18-like' than 'phenyl-like' in many of the tests undertaken. This is probably not unexpected since all five phases were reversed phase.

Benzene Derivatives↗

Chromatographic properties of reversed-phase stationary phases under pressure- and electro-driven conditions.

Seven different reversed-phase (RP) stationary phases were examined under high-performance liquid chromatographic (pressure-driven, HPLC), and capillary electrochromatographic (electro-driven, CEC) conditions. Characterization of the stationary phases was performed following well-established test procedures providing a number of distinct column descriptors: hydrophobicity, hydrophobic selectivity and silanol activity. These parameters were used to describe the behavior of the RP-columns under both HPLC and CEC conditions. It is shown that chromatographic characteristics of porous RP-phases greatly depend on the mode of operation. By contrast, column descriptors of a non-porous viz. solid RP-phase material hardly differed for HPLC and CEC conditions.

Chromatography, High Pressure Liquid↗

Characterisation of reversed-phase stationary phases for the liquid chromatographic analysis of basic pharmaceuticals by thermodynamic data.

This paper describes the characterisation of reversed-phase liquid chromatography (RPLC) columns using thermodynamic measurements. Retention versus 1/T data were used to construct Van't Hoff plots. The slope of these plots indicates the standard enthalpy of transfer of the analyte from the mobile to the stationary phase. The standard entropy can be calculated from the intercept. Van't Hoff plots were linear for the investigated RPLC columns, meaning that for basic analytes over the temperature range studied no changes in the retention mechanism occurred. Enthalpies and entropies of transfer of basic analytes from the mobile to the stationary phase revealed information about the types of interaction of protonated and neutral compounds with the stationary phases. However, a clear view using the present set of basic compounds on how these thermodynamic data may explain the observed substantial differences in peak symmetry cannot be given. It is considered that addition of N,N-dimethyloctylamine (DMOA) to the eluent will results in a dynamically coating of the stationary phase. Addition of DMOA to the eluent resulted for protonated basic compounds in a reduction of both enthalpy and entropy. In practice, with DMOA in the eluent symmetrical peaks were obtained. It is assumed that this is due to blocking residual silanols and/or ion exclusion effects.

Chromatography, Liquid↗

Phase transitions of reversed-phase stationary phases. Cause and effects in the mechanism of retention.

We provide a somewhat historical perspective on the work that has been accomplished that supports the suggestion of phase transitions in reversed-phase liquid chromatographic bonded phases. In addition to this general review, we consider from both a practical and theoretical viewpoint the implications of such transitions in the rational design of improved reversed-phase separations. Analytical theory and molecular simulation approaches to chromatographic stationary phases and related systems are reviewed. Initial results are presented on the temperature, density and chain length dependences of stationary phase properties. The role of computer simulation in analyzing transition behavior and retention processes is discussed.

Chemical Phenomena↗

Studies on the separation of hydronium ion using surfactant-modified reversed-phase stationary phases and eluents containing an acidified electrolyte.

A further investigation of a chromatographic system allowing determination of hydrogen ions is reported. For this purpose an octadecylsilica column dynamically modified with sodium dodecylsulfate (SDS) or lithium dodecylsulfate (LDS) was used as stationary phase and a slightly acidified electrolyte (usually KCl)-SDS solution was used as the eluent. The concentration of SDS, KCl and the acidity of the eluent affected the structure of aggregates formed by the molecules of dodecylsulfate at the surface of the stationary phase. These aggregates of dodecylsulfate were found to be responsible for the appearance of a chromatographic peak attributed to the presence of H3O+ ions in a sample. Other cations in the sample could be separated in the same manner, permitting the simultaneous separation of monovalent cations from H3O+. The detection limit for H3O+ ions was 2.25 x 10(-6) M using an eluent comprising 0.3 mM LDS, 50.0 mM KCl and 0.10 mM H2SO4. The proposed method is shown to be applicable for the determination of free H3O+ ions in aqueous solutions of strong acids.

Acids↗

Prediction of the retention in reversed-phase liquid chromatography using solute-mobile phase-stationary phase polarity parameters.

A previously reported algorithm, based on the equation: log k = (log k)o + p(PN(m) - PN(s)), that relates the retention in reversed-phase liquid chromatography with solute (p), mobile phase (PN(m)) and stationary phase (PN(s)) relative polarity parameters, is improved. The retention data reported by several authors for different sets of compounds, eluted with acetonitrile-water and methanol-water mixtures, are used to test the algorithm and elaborate a database of p values. The methodology is successfully applied to predict the retention using PN(m), values calculated as PN(m) = 1.00 - (2.13phi)/(1+1.4phi) for acetonitrile-water and PN(m) = 1.00 - (1.33phi)/(l1 + 0.47phi) for methanol-water, phi being the organic solvent volumetric fraction. The polarity parameters are demonstrated to be useful to transfer retention data between solvent systems and between columns. Accordingly, the retention in a solvent system is predicted by characterising the working column with a small training set of compounds having diverse polarities, and using the p values known for another solvent system or column. The p polarity parameter is found to be a good descriptor of the retention, allowing the prediction of the expected elution order and peak overlaps.

Algorithms↗

Characterization and comparison of the chromatographic performance of different types of reversed-phase stationary phases.

The chromatographic performance of several base-deactivated stationary phases was evaluated with a specific chromatographic test. Seven basic test compounds, possessing different physico-chemical properties were injected on different supports with two mobile phases: one at pH 7.0 (acetonitrile-phosphate buffer, 40:60, v/v), and the other at pH 3.0 (acetonitrile-phosphate buffer, 15:85, v/v). Chromatographic parameters obtained under these conditions were treated by principal component analysis (PCA) to separate base deactivated supports according to their silanol activity (pH 7.0 mobile phase) and hydrophobic properties (pH 3.0 mobile phase). The information given by the specific test column evaluation was improved with complementary chemometric tools such as hierarchical cluster analysis. The same base deactivated supports were also tested following a general test procedure issued from the literature and obtained fundamental properties (in particular silanol activity and hydrophobicity) were compared with column evaluation obtained with the specific test: results were in good agreement, although the use of the specific test offered a better differentiation between numerous base-deactivated supports.

Chemical Phenomena↗

Bare silica as a reverse-phase stationary phase: liquid chromatographic separation of antihistamines with buffered aqueous organic mobile phases.

Unbonded silica gel is an effective support for reverse-phase liquid chromatographic separations of lipophilic amines. Simple buffered aqueous-organic mobile phases provide rapid isocratic separations of antihistamines. Phenylpropanolamine hydrochloride, chlorpheniramine maleate, and dextromethorphan hydrobromide are separated in 8 min on bare silica with a mobile phase of 75% methanol and 25% water which is 0.01 M in (NH4)2HPO4. Quantitation is reproducible. A wide variety of additional compounds may be separated using the same mobile phase.

Chromatography, Liquid↗

Cation-exchange liquid chromatography of choline and acetylcholine on free shielded silanols of silica-based reversed-phase stationary phases.

Free anionic functions present on the surface of reversed-phase packing materials were used for the selective cation-exchange preconcentration and separation of the neurotransmitters choline and acetylcholine from a biological matrix. The cation-exchange behaviour of different reversed-phase packing materials in the neat aqueous mobile phase, the properties of an end-capped column, the dependence of capacity factors and peak shape on the concentration of counter ions, ionic strength, pH and the addition of acetonitrile and optimum conditions for enzymatic conversion of solutes to hydrogen peroxide were studied. The studied reversed-phase columns exhibit better pH stability and longer lifetimes than normal silica-based cation exchangers. Acetylcholine is an effective and sensitive test sample for the measurement of adsorption on silica support. A large sample volume was injected onto a precolumn inserted instead of an injection valve and after injection the solutes were focused and separated on an analytical column with a mobile phase containing tetramethylammonium perchlorate as the counter ion.

Acetonitriles↗

Ultrasound driven synthesis of reversed-phase stationary phases for liquid chromatography using 4-dimethyl-aminopyridine as acid-acceptor.

A reproducible new method for synthesizing high density monomeric reversed-phase chromatographic packings based on the use of ultrasonic waves as the driving force for the bonding reaction is presented. The use of ultrasound has two distinct advantages over traditional reflux methods. It provides a reaction driving force that is independent of temperature; in addition, the power of the ultrasonic driving force can be varied using a variable-power ultrasonic probe. The use of a novel acid-acceptor, 4-dimethylaminopyridine, is also recommended in the bonding reaction due to its ease of use and the resulting high bonding densities.

4-Aminopyridine↗

Separation of amino acids, peptides and proteins on molecularly imprinted stationary phases.

Stationary phases, to be used in high-performance liquid chromatography, were tailor-made for the separation of amino acids, peptides and proteins. The stationary phases were prepared by molecular imprinting, applying two different approaches. Low-molecular-mass compounds were imprinted in bulk polymers by copolymerization of functional monomers and cross-linkers in the presence of the compound of interest, the print molecule. These polymers were, after extraction of the print molecule, successfully applied as chiral stationary phases, showing high resolution and load capacity. The development of a surface-imprinting approach for the preparation of stationary phases selective for proteins is also discussed.

Amino Acid Sequence↗

Leishmania braziliensis: protein, carbohydrate, and antigen differences between log phase and stationary phase promastigotes in vitro.

When Leishmania species are grown in vitro, parasites from the stationary phase differ from those in log phase growth in being more infective and more resistant to complement and macrophage mediated killing. In the present study, log phase and stationary phase promastigotes of Leishmania braziliensis panamensis were compared at the molecular level. Differences in polypeptide and glycoprotein composition and antigenicity between log and stationary phase promastigotes of L. b. panamensis were detected by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blotting; the former showed that two polypeptides were unique to log phase promastigotes and one was unique to stationary phase promastigotes. There were also differences in surface lectin binding characteristics of log and stationary phase promastigotes. Live stationary phase promastigotes bound more concanavalin and lentil lectin than log phase promastigotes, indicating a greater number of mannose residues on their surfaces.

Animals↗

Synthesis and evaluation of polymeric continuous bed (monolithic) reversed-phase gradient stationary phases for capillary liquid chromatography and capillary electrochromatography.

There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.

Benzene Derivatives↗

Retention mechanisms in reversed-phase chromatography. Stationary phase bonding density and solute selectivity.

Chromatographic selectivity for small, non-polar solutes has been determined as a function of monomeric octadecyl stationary phase bonding density over the range 1.74-4.07 mumol/m2. Phenyl or shape selectivity increases with increasing bonding density, whereas methylene selectivity remains approximately constant. These findings are in agreement with the mean field statistical thermodynamic theory of Dill, which predicts that increased stationary phase chain density should lead to increased anisotropic chain ordering and increased solute-shape selectivity. These studies provide further evidence that partitioning, not adsorption, is the dominant mode of retention for small, non-polar molecules in reversed-phase liquid chromatography.

Chemical Phenomena↗

Mobile phase versus stationary phase approaches to the direct injection of biological fluids in liquid chromatography.

The liquid chromatographic analysis of drugs in urine through direct injection without any sample pretreatment was extended to micellar chromatography with nonionic surfactants, the Pinkerton ISRP column and the shielded hydrophobic phase (Hisep) column. The feasibility of using each was demonstrated through the determination of the diuretic, hydrochlorothiazide, in urine. Good separation, recovery, precision and linearity, and adequate limits of detection were obtained for this analysis with all three techniques. The advantages and limitations of the mobile phase approach of micellar chromatography and the two stationary phase approaches are discussed for the direct injection of urine as well as other biological fluids.

Chromatography, High Pressure Liquid↗

On-chip electrochromatography using sol-gel immobilized stationary phase with UV absorbance detection.

A chromatography column on a chip was fabricated by immobilizing reversed-phase stationary phase particles (5 microm, C4) using sol-gel technology. Channels were fabricated in quartz using photolithography and wet etching. Localization of the stationary phase was achieved by immobilizing the stationary phase at the desired location in the separation channel prior to bonding of the cover plate. Cross channel design was employed for gated injection. An optical fiber setup was developed for carrying out on-chip UV absorbance detection. The effective optical path length was theoretically determined for the trapezoidal shaped channel and the result was shown to match closely with the experimentally determined value. The effect of applied voltage on velocity was evaluated using thiourea as an unretained marker. Separation performance of the stationary phase was demonstrated by separation of three peptides (Trp-Ala, Leu-Trp and Trp-Trp) under isocratic chromatographic conditions.

Chromatography, Micellar Electrokinetic Capillary↗

Developments in the use of soluble ionic polymers as pseudo-stationary phases for electrokinetic chromatography and stationary phases for electrochromatography.

This article reviews the development, characterization and application of soluble ionic polymeric materials as pseudo-stationary phases for electrokinetic chromatography and as stationary phases for electrochromatography since 1997. Polymeric pseudo-stationary phases for electrokinetic chromatography, including cationic polymers, anionic siloxane and acrylamide polymers, polymerized surfactants (micelle polymers), and chiral polymers are reviewed. Also reviewed are suspended molecularly imprinted polymer micro-particles. Application of polymeric pseudo-stationary phases with electrospray ionization mass spectrometric detection is presented. Recent progress in the development and characterization of physically adsorbed stationary phases for electrochromatography using polymers of the same or similar chemistry is also reviewed.

Chromatography, Micellar Electrokinetic Capillary↗