PubMed Health⌕ Search

Biomedical subjects

A D Gosbell

Publications and source records attributed to A D Gosbell.

6 recordsLinked to original sources

Insulin receptor and insulin receptor substrate-I in rat retinae.

Insulin receptor substrate-I (IRS-I) is a major cytosolic substrate of the insulin receptor Expression of insulin receptor and IRS-I, and the distribution of these components of the insulin-signalling pathway, were investigated in rat retinae. Insulin receptor and IRS-I were located in retinal sections with anti-insulin receptor and anti-IRS-I antibodies. Reverse transcription-polymerase chain reaction (RT-PCR) of retinal mRNA was performed with primers specific for insulin receptor and IRS-I gene sequences. Immunohistochemistry demonstrated distinct but closely associated staining patterns for insulin receptor and IRS-I throughout rat retinae. The RT-PCR product from rat retinal insulin receptor mRNA corresponded to the high affinity insulin receptor isoform. The RT-PCR product for retinal IRS-I mRNA agreed with that predicted from the gene sequence. The expression of IRS- I and insulin receptors indicates a signalling mechanism by which insulin can influence retinal metabolism or function.

Animals↗

Photodynamic therapy: a 5-year study of its effectiveness in the treatment of posterior uveal melanoma, and evaluation of haematoporphyrin uptake and photocytotoxicity of melanoma cells in tissue culture.

A human melanoma cell line RVH-421 which selectively demonstrates melanin synthesis when cultured in L15 Leibowitz medium but not in RPMI medium was used as a model to examine haematoporphyrin derivative (HPD) uptake and the photocytotoxicity of photodynamic therapy (PDT). Confocal scanning microscopy and extraction fluorometry showed HPD uptake in both non-pigmented and pigmented melanoma cells. Phototoxicity was determined by incubating pigmented and non-pigmented monolayer cells with HPD, exposing them to variable periods of white fluorescent light and calculating the number of viable cells in the samples relative to the controls. Both the non-pigmented and pigmented melanoma cells were affected by light-dependent cytotoxicity which was greater in the non-pigmented cells. Melanin or other substances may reduce the photo-oxidative effects of PDT. Posterior uveal melanomas in 36 patients were treated with PDT with the longest duration of tumour control being 6.5 years. Kaplan-Meier survival analysis showed that 76% of melanomas were not growing at the end of the first year, declining to 62% at the end of the second year, with 38% showing no signs of growth at the end of the fifth year. No eyes were lost as a result of PDT. Cox's hazards analysis showed that the degree of tumour pigmentation and patient age at therapy significantly influence the tumour response to PDT.

Adult↗

Volume measurement of intraocular tumours by cross-sectional ultrasonographic scans.

The volume of intraocular tumours can be calculated from tumour height and cross-sectional areas measured in maximal orthogonal B-mode ultrasonograms, on the assumption that the tumour morphology is hemi-ellipsoidal. Comparison of this method with an accurate but more complex computer-aided B-mode ultrasonic tomographic method demonstrated a highly linear relationship with a correlation coefficient of 0.93. Furthermore, the comparison of cross-sectional areas measured from B-scan images and histological cross-sections in a small series of enucleated eyes demonstrated that tumour cross-sectional area measured from ultrasound images provides an accurate representation of the true physical size of the tumour in the globe. This method can be easily implemented with readily available B-mode ultrasound equipment. Unlike previously reported volume measurement methods, customised hardware or software is not required. The method is rapid and easy to perform, and may offer a useful standard method of measuring and monitoring intraocular tumours.

Choroid Neoplasms↗

Computer-assisted analysis of the electro-oculogram.

A method of acquiring and analysing electro-oculogram signals was developed using computer-aided techniques. The repetitive nature, characteristic shape and spectral properties of the electro-oculogram are used in the automated analysis, enabling the retinal resting potential to be investigated. Online computer-aided automatic analysis of the electro-oculogram is efficient, reliable and accurate. Automated analysis produced results that have a highly significant degree of correlation (P less than 0.001) with the results obtained manually from strip chart recording of the electro-oculogram signals. The increased accuracy of the automatic analysis system demonstrates a significantly reduced (McNemar's Test) false positive rate in classifying abnormal results on the basis of Arden ratio. The computer-aided analysis system offers a useful clinical means of measuring the electro-oculogram for diagnostic and research purposes.

Dark Adaptation↗

Computer-aided area measurement of ocular images.

Using a combination of computer-aided measurement techniques and fundus camera images, the area of regions of interest on the fundus can be measured. If these area measurements are corrected for the magnification effects of the patient's visual system, and the fundus camera optics, an estimate of the true anatomical size of the measured object can be determined in physical units. While the results of measuring models indicate a maximum error of 6% for the system, the results of clinical trials demonstrate an average error of 10% for well-defined areas of interest, with increasing error of up to 30% for poorly defined areas of interest.

Adult↗

Computer-aided volume measurement of choroidal melanomas.

Using a combination of conventional B-scan ultrasonography, standard video techniques, computer image digitization and area analysis, it is possible to measure the volume of choroidal melanomas by area calculation of successive ultrasound image slices, allowing the monitoring of such tumors. The design of a combined water-bath and linear tracking B-scan transducer is presented, together with a description of the instrumentation and computer software required. The results of volume measurements performed upon eye models demonstrated that melanomas of volume greater than 100 mm3 could be measured with an average error of 6%. The problems associated with linear calibration of the system from scan-head to analysed image, resolution of the digitised image, reproducibility of the measurements, sources of error and assumptions made in formulating the measurement procedure are discussed.

Adult↗