Computer-assisted analysis of the electro-oculogram.

Abstract

A method of acquiring and analysing electro-oculogram signals was developed using computer-aided techniques. The repetitive nature, characteristic shape and spectral properties of the electro-oculogram are used in the automated analysis, enabling the retinal resting potential to be investigated. Online computer-aided automatic analysis of the electro-oculogram is efficient, reliable and accurate. Automated analysis produced results that have a highly significant degree of correlation (P less than 0.001) with the results obtained manually from strip chart recording of the electro-oculogram signals. The increased accuracy of the automatic analysis system demonstrates a significantly reduced (McNemar's Test) false positive rate in classifying abnormal results on the basis of Arden ratio. The computer-aided analysis system offers a useful clinical means of measuring the electro-oculogram for diagnostic and research purposes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A D Gosbell, W R Barry, I Favilla, G Burkitt. 1991. Computer-assisted analysis of the electro-oculogram.. https://doi.org/10.1111/j.1442-9071.1991.tb00682.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LED-generated multifocal ERG on- and off-responses in complete congenital stationary night blindness -- a case report.

We report on the application of a light emitting diode (LED) screen to elicit multifocal ERG on- and off-responses in a patient presenting with the complete type of congenital stationary night blindness (cCSNB): A 63-years old woman was diagnosed with cCSNB by means of standard ERG procedures and dark adaptometry. To confirm this diagnosis and to investigate topographical differences of on- and off-responses a multifocal approach employing long-duration stimuli was added. Results of mfERG-testing were averaged in three groups (a central area of 7.5 degrees , a ring area of 7.5-21.9 degrees and a peripheral ring of 21.9-31.1 degrees ). When compared to normal controls (n = 4) on-responses (P1-amplitudes) were severely reduced symmetrically at all eccentricities, while off-responses showed no reduction resulting in an increased off/on-ratio. Furthermore on-latencies of P1 were delayed symmetrically at all eccentricities, whereas off-latencies were normal. To our knowledge this is the first report of multifocal on- and off-responses in a CSNB-patient. Stimulus-generation with a LED-screen provides the advantage of a stable luminance during the long-duration on-phase.

Dark Adaptation↗

Is the spectacle lens jack-in-the-box phenomenon really due to the lenses?

The calculation of the extent of the ring scotoma around positive lenses, as conventionally taught to students of clinical optics, indicates that the scotoma is of a significant size. Using knife-edge lenses this study shows that the calculations are invalid due to the finite size of the eye's entrance pupil and in many instances the scotoma is shown not to exist. The effect noticed in clinical practice is probably largely due to the frame and the edging techniques used which add to the refractive scotoma which is present with high powered lenses, large apertures and/or small pupil sizes.

Dark Adaptation↗