PubMed Health⌕ Search

Biomedical subjects

A G Tibbe

Publications and source records attributed to A G Tibbe.

3 recordsLinked to original sources

Cell analysis system based on immunomagnetic cell selection and alignment followed by immunofluorescent analysis using compact disk technologies.

BACKGROUND: Although the flow cytometer has become the standard in cell analysis, it has limitations. Recently, we introduced a new cell analysis method based on immunomagnetic selection and aligning of cells. No flow system is needed and cell analysis can be performed in whole blood. METHODS: Whole blood is incubated with fluorescent labels and immunomagnetic nanoparticles. The blood is injected into a capillary that is in a strong magnetic field. The immunomagnetic-labeled cells move upward and align themselves along ferromagnetic lines present on the upper surface of the capillary. An optical focus and tracking system analogous to that used in a conventional compact disk player focuses a 635-nm laser-diode on the magnetically aligned cells. The emitted fluorescence signals are projected on two photomultipliers. Allophycocyanin (APC)-labeled CD4 (CD4-APC) and Cyanin5.5 (Cy5.5)-labeled CD8 (CD8-Cy5.5) antibodies and Oxazine750, all red excited, are used as fluorescent labels. RESULTS: A differential white blood cell count performed in whole blood is obtained using the CD4-APC in combination with Oxazine750. The results are compared with the Technicon-H1 hematology analyzer. Correlation coefficients of 0.91 for neutrophilic granulocytes, 0.93 for lymphocytes, 0.93 for monocytes, and 0.96 for eosinophilic granulocytes were obtained. Immunofluorescence is demonstrated using CD4-APC and CD8-Cy5.5. The absolute counts obtained for CD4+ and CD8+ are compared with the Coulter Epics XL flow cytometer. Correlation coefficients of, respectively, 0.91 and 0.94 were obtained. CONCLUSION: We conclude that our system is as capable as a standard flow cytometer or hematology analyzer for a reliable routine white blood cell analysis, including immunophenotyping, and can be used as an easy-to-handle disposable white blood cell test.

CD4 Antigens↗

Intracellular reactions in single human granulocytes upon phorbol myristate acetate activation using confocal Raman microspectroscopy.

We have obtained new evidence for the occurrence of intracellular NADPH-oxidase activity in neutrophilic and eosinophilic granulocytes upon stimulation with phorbol myristate acetate (PMA). PMA activation leads to a partial translocation of cytochrome b(558) from the membranes of the specific granules to the plasma membrane. It was suggested that NADPH-oxidase activity only takes place in the plasma membrane, leading to an extracellular release of oxygen metabolites because cellular self-destruction can be avoided in this way. The effects of PMA activation were indirectly studied in recent experiments employing scavengers of extracellular superoxide anion and hydrogen peroxide, and support for intracellular NADPH-oxidase activity was obtained. In this paper we use Raman microspectroscopy as a direct method to study intracellular molecular reactions that result from cellular triggering by PMA. The molecular specificity of this microscopic method enables us to show that intracellular reduction of both myeloperoxidase (MPO) and cytochrome b(558) occurs in neutrophilic granulocytes. Control measurements with cytochrome b(558)-deficient neutrophilic granulocytes did not show a reduction of intracellular MPO. This is direct support for the occurrence of intracellular NADPH-oxidase activity in organelles that must be in close contact with the azurophilic granules that contain MPO. Furthermore, a comparison was made with chemical reactions occurring in eosinophilic granulocytes after activation with PMA. Moreover, in these cells an intracellular reduction of eosinophil peroxidase was observed.

Biophysical Phenomena↗

Optical tracking and detection of immunomagnetically selected and aligned cells.

We have developed a platform for cell analysis based on immunomagnetic selection and magnetic alignment of cells in combination with an epi-illumination tracking and detection system. Whole blood was labeled with ferromagnetic nanoparticles and fluorescent probes, and placed in a magnetic field in a chamber. Cells labeled with ferromagnetic nanoparticles moved upward and aligned along ferromagnetic lines deposited by lithographic techniques on an optically transparent surface of the chamber. An epi-illumination system using a 635 nm laser diode as a light source scanned the lines and measured signals obtained from the aligned cells. The cell counts per unit of blood volume obtained with the system correlated well with those obtained from the counts from a standard hematology analyzer and flow cytometer. The cell analysis platform is significantly less complex and more sensitive than current cell analysis equipment and provides additional functionality through its ability to subject the cells to repeated and varied analyses while they remain in a natural environment (i.e., whole blood).

Computer Simulation↗