PubMed Health⌕ Search

PubMed · 11122482

Cell analysis system based on immunomagnetic cell selection and alignment followed by immunofluorescent analysis using compact disk technologies.

Abstract

BACKGROUND: Although the flow cytometer has become the standard in cell analysis, it has limitations. Recently, we introduced a new cell analysis method based on immunomagnetic selection and aligning of cells. No flow system is needed and cell analysis can be performed in whole blood. METHODS: Whole blood is incubated with fluorescent labels and immunomagnetic nanoparticles. The blood is injected into a capillary that is in a strong magnetic field. The immunomagnetic-labeled cells move upward and align themselves along ferromagnetic lines present on the upper surface of the capillary. An optical focus and tracking system analogous to that used in a conventional compact disk player focuses a 635-nm laser-diode on the magnetically aligned cells. The emitted fluorescence signals are projected on two photomultipliers. Allophycocyanin (APC)-labeled CD4 (CD4-APC) and Cyanin5.5 (Cy5.5)-labeled CD8 (CD8-Cy5.5) antibodies and Oxazine750, all red excited, are used as fluorescent labels. RESULTS: A differential white blood cell count performed in whole blood is obtained using the CD4-APC in combination with Oxazine750. The results are compared with the Technicon-H1 hematology analyzer. Correlation coefficients of 0.91 for neutrophilic granulocytes, 0.93 for lymphocytes, 0.93 for monocytes, and 0.96 for eosinophilic granulocytes were obtained. Immunofluorescence is demonstrated using CD4-APC and CD8-Cy5.5. The absolute counts obtained for CD4+ and CD8+ are compared with the Coulter Epics XL flow cytometer. Correlation coefficients of, respectively, 0.91 and 0.94 were obtained. CONCLUSION: We conclude that our system is as capable as a standard flow cytometer or hematology analyzer for a reliable routine white blood cell analysis, including immunophenotyping, and can be used as an easy-to-handle disposable white blood cell test.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A G Tibbe, B G de Grooth, J Greve, P A Liberti, G J Dolan, L W Terstappen. 2001-01-01. Cell analysis system based on immunomagnetic cell selection and alignment followed by immunofluorescent analysis using compact disk technologies.. https://pubmed.health/record/pubmed%3A11122482/cell-analysis-system-based-on-immunomagnetic-cell-selection-and-alignment-followed-by-immunofluoresc

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

The effect of nutritional support on weight gain of HIV-infected children with prolonged diarrhoea.

AIM: To examine the effect on growth and immunity of enhanced calorie and protein provision to HIV-infected children presenting with prolonged diarrhoea. METHODS: A total of 169 HIV-infected children aged 6-36 months with diarrhoea for 7 days or more were randomly assigned to either standard nutrition support for children with prolonged diarrhoea or an enhanced diet started during hospitalisation and continued after discharge. The change in weight between enrolment and 8, 14 and 26 weeks and changes in plasma HIV-RNA and CD4 cell count at 8 and 26 weeks were estimated. RESULTS: Children receiving enhanced nutrition achieved significantly more weight gain (p < 0.001) between enrolment and 8 weeks than children on the standard diet (median increase in weight-for-age standard deviation score +1.02 vs. +0.01). After 8 weeks median weight velocity was normal and similar in both groups. The change in median CD4 count was similar in both groups. The 26-week mortality rate was high in both groups (standard support: 22%, enhanced support: 29%). CONCLUSIONS: Nutrition support of children with advanced HIV infection and prolonged diarrhoea resulted in significant and sustained weight gain, but did not improve CD4 counts or survival. These results support integrated nutrition interventions for HIV-infected children.

CD4 Antigens↗

Agranular CD4+/CD56+ hematodermic neoplasm: a distinct entity described in the recent World Health Organization-European Organization for Research and Treatment of Cancer classification for cutaneous lymphomas.

Agranular CD4+/CD56+ hematodermic neoplasm is a distinct form of lymphoma with aggressive behavior and marked predilection for cutaneous involvement. Because of CD56 positivity, natural killer cells were initially suggested as the cell of origin in this tumor. In the recent World Health Organization-European Organization for Research and Treatment of Cancer classification, the term blastic natural killer cell lymphoma has been replaced with CD4+/CD56+ hematodermic neoplasm because of its derivation from a plasmacytoid dendritic cell precursor. Clinicopathologic features, immunohistochemical features, and differential diagnosis of this rare neoplasm with emphasis on the recent World Health Organization-European Organization for Research and Treatment of Cancer classification are discussed.

CD4 Antigens↗

Kinetic studies of HIV-1 and HIV-2 envelope glycoprotein-mediated fusion.

BACKGROUND: HIV envelope glycoprotein (Env)-mediated fusion is driven by the concerted coalescence of the HIV gp41 N-helical and C-helical regions, which results in the formation of 6 helix bundles. Kinetics of HIV Env-mediated fusion is an important determinant of sensitivity to entry inhibitors and antibodies. However, the parameters that govern the HIV Env fusion cascade have yet to be fully elucidated. We address this issue by comparing the kinetics HIV-1IIIB Env with those mediated by HIV-2 from two strains with different affinities for CD4 and CXCR4. RESULTS: HIV-1 and HIV-2 Env-mediated cell fusion occurred with half times of about 60 and 30 min, respectively. Binding experiments of soluble HIV gp120 proteins to CD4 and co-receptor did not correlate with the differences in kinetics of fusion mediated by the three different HIV Envs. However, escape from inhibition by reagents that block gp120-CD4 binding, CD4-induced CXCR4 binding and 6-helix bundle formation, respectively, indicated large difference between HIV-1 and HIV-2 envelope glycoproteins in their CD4-induced rates of engagement with CXCR4. CONCLUSION: The HIV-2 Env proteins studied here exhibited a significantly reduced window of time between the engagement of gp120 with CD4 and exposure of the CXCR4 binding site on gp120 as compared with HIV-1IIIB Env. The efficiency with which HIV-2 Env undergoes this CD4-induced conformational change is the major cause of the relatively rapid rate of HIV-2 Env mediated-fusion.

CD4 Antigens↗