PubMed Health⌕ Search

Biomedical subjects

A G Webb

Publications and source records attributed to A G Webb.

At least 19 recordsLinked to original sources

Union of capillary high-performance liquid chromatography and microcoil nuclear magnetic resonance spectroscopy applied to the separation and identification of terpenoids.

This paper describes the first coupling of a commercial capillary HPLC system with a diode array spectrophotometric detector and a custom-built nuclear magnetic resonance (NMR) flow microprobe. The eluent from a 3-microm diameter C18 HPLC column is linked to a 500 MHz 1H-NMR microcoil probe with an observe volume of 1.1 microl. The separation and structurally-rich detection of a mixture of terpenoids under both isocratic and gradient solvent elution conditions is presented. The lowest limits of detection yet reported for capillary HPLC on-line measurement (i.e., 37 ng for alpha-pinene) are achieved with this system. The complementary nature of diode array and NMR detection allows stopped-flow data collection from analytes which would otherwise go unnoticed in continuous-flow NMR. Moreover, stopped-flow NMR data is presented for the detection of a trace (sub-nmol) impurity in the sample mixture. Since NMR signals degrade and shift during solvent gradients, flow injection analysis studies are conducted with injected solvent plugs differing in mobile phase composition. The NMR signal degradation accompanying these injections is largely due to the variance in chemical shift with the solvent composition rather than to changes in magnetic susceptibility of the solvent. Characterization of such effects enables the development of improved NMR probes for the coupling of capillary HPLC and NMR.

Chromatography, High Pressure Liquid↗

Apparent diffusion tensor measurements in myelin-deficient rat spinal cords.

The apparent diffusion tensor (ADT) was measured in excised and fixed spinal cords from myelin-deficient (md) rats and age-matched controls. These data were used to obtain the principal diffusivities of the ADT, and also the scalar invariant parameters _D (averaged principal diffusivity) and A(sigma) (anisotropy index) for four white matter and two gray matter regions. The results for white matter regions showed that the principal diffusivities were significantly higher for md animals, and while the _D was increased in tissue from md animals, the A(sigma) was found to be decreased. Grey matter _D was measured to be between those of white matter from control and md animals, and the A(sigma) was much smaller than that of white matter from both sets of animals, indicating that diffusion in md white matter is more anisotropic than in gray matter. The results show that while myelination is not a prerequisite for diffusion anisotropy, it does influence the magnitude of the observed anisotropy. Magn Reson Med 45:191-195, 2001.

Animals↗

Magnetic resonance microscopy of morphological alterations in mouse trabecular bone structure under conditions of simulated microgravity.

This work describes the use of magnetic resonance (MR) microscopy to examine changes in tibial trabecular bone structure in mice following 28 days of hindlimb suspension, a model simulating the effects of microgravity in rodents. In this first MR study involving mice, analysis of 3D images showed that apparent bone volume fraction, trabecular number, and trabecular thickness were decreased, and apparent trabecular spacing increased, significantly (P < 0.05) in hindlimb-suspended mice compared to controls. These changes agreed well with light microscopy measurements from an independent study and also with actual spaceflight experiments with rats.

Animals↗

Unifying linear prior-information-driven methods for accelerated image acquisition.

In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework provides a conceptual link that facilitates comparison among these methods to reveal their strengths and weaknesses. By considering the limitations of existing methods, a new member in this class of methods was developed. The broad-use linear acquisition speed-up technique (BLAST) uses the estimated amount of change within the FOV as prior information. BLAST has the flexibility of incorporating a variable amount of prior information to avoid the misleading appearance of "phantom features," which arise from overconstraining the reconstruction. Examples from dynamic imaging and MR thermometry are shown.

Body Temperature↗

MR microscopy of multicomponent diffusion in single neurons.

This study examines multicomponent diffusion in isolated single neurons and discusses the implications of the results for macroscopic water diffusion in tissues. L7 Aplysia neurons were isolated and analyzed using a 600 MHz Bruker wide-bore instrument with a magnetic susceptibility-matched radiofrequency microcoil. Using a biexponential fit, the apparent diffusion coefficients (ADCs) from the cytoplasm (with relative fraction) were 0.48 +/- 0.14 x 10(-3) mm2 x s(-1) (61 +/- 11%) for the fast component, and 0.034 +/- 0.017 x 10(-3) mm2 x s(-1) (32 +/- 11%) for the slow component (N = 10). Diffusion in the nucleus appears to be primarily monoexponential, but with biexponential analysis it yields 1.31 +/- 0.32 x 10(-3) mm2 x s(-1) (89 +/- 6%) for the fast component and 0.057 +/- 0.073 x 10(-3) mm2 x s(-1) (11 +/- 6%) for the slow (N = 5). The slow component in the nucleus may be explained by cytoplasmic volume averaging. These data demonstrate that water diffusion in the cytoplasm of isolated single Aplysia neurons supports a multiexponential model. The ADCs are consistent with previous measurements in the cytoplasm of single neurons and with the slow ADC measurement in perfused brain slices. These distributions may explain the multiple compartments observed in tissues, greatly aiding the development of quantitative models of MRI in whole tissues.

Animals↗

A probe design for the acquisition of homonuclear, heteronuclear, and inverse detected NMR spectra from multiple samples.

A new probe design is presented for obtaining homonuclear, heteronuclear, and inverse detected NMR spectra from more than one sample in the same total data acquisition time as for a single sample, thus increasing data acquisition efficiency. Specifically, a two-coil system, with each solenoidal coil impedance matched to 50 Omega at both proton and nitrogen frequencies, has been designed for operation at 11.7 T with an observe volume of 15 microL for each coil. Isolation between the two frequencies for each individual coil, and at each frequency between coils, was greater than 30 dB. Two-dimensional COSY and HMQC spectra were obtained with negligible NMR cross-talk between the two coils.

Adenosine Triphosphate↗

IL-12 treatment of endogenously arising murine brain tumors.

A number of recent studies have indicated that T cells can be stimulated to attack transplanted brain tumors in rodent models. As IL-12 has been shown to activate cytotoxic T cell responses, we tested the idea that it might stimulate a T cell response against endogenous brain tumors that arise in SV40 large T Ag transgenic mice (SV11). SV11 mice develop tumors of the choroid plexus, a specialization of the ependymal lining of the brain ventricles. They are a particularly relevant model of human disease, because they are immunocompetent but immunologically tolerant of the tumors. SV11 mice were treated with recombinant murine IL-12 for 10 days. Tumors grew more slowly than in control treated mice, and in some cases were reduced in size, as assessed by magnetic resonance imaging before and after treatment. At the end of treatment, tumors, but not brain parenchyma, exhibited extensive infiltration of activated CD8(+) and CD4(+) T cells. Tumors also showed a reduction in vascular density. Mice treated with IL-12 lived significantly longer than control mice. Tumors that progressed were nearly devoid of T cells, indicating that the T cell response was not sustained. In addition, some mice that had a substantial tumor burden at the beginning of treatment displayed evidence of immunosuppression, which might be related to TGF-ss2 detected in tumors. We conclude that IL-12 treatment can initiate an anti-tumor response even against endogenously arising brain tumors, but factors that will allow a sustained and more effective anti-tumor response need to be determined.

Animals↗

Monitoring temperature changes in capillary electrophoresis with nanoliter-volume NMR thermometry.

Nanoliter-volume proton nuclear magnetic resonance (NMR) spectroscopy is used to monitor the electrolyte temperature during capillary electrophoresis (CE). By measuring the shift in the proton resonance frequency of the water signal, the intracapillary temperature can be recorded noninvasively with subsecond temporal resolution and spatial resolution on the order of 1 mm. Thermal changes of more than 65 degrees C are observed under both equilibrium and nonequilibrium conditions for typical CE separation conditions. Several capillary and buffer combinations are examined with external cooling by both liquid and air convection. Additionally, NMR thermometry allows nonequilibrium temperatures in analyte bands to be monitored during a separation. As one example, a plug of 1 mM NaCl is injected into a capillary filled with 50 mM borate buffer. Upon reaching the NMR detector, the temperature in the NaCl band is more than 20 degrees C higher than the temperature in the surrounding buffer. Such observations have direct applicability to a variety of studies, including experiments which utilize sample stacking and isotachophoresis.

Electrophoresis, Capillary↗

NMR spectroscopy of single neurons.

The first spatially localized NMR spectra of osmolytes and metabolites from single isolated neurons have been obtained using a combination of high magnetic field strengths and NMR radio frequency (RF) microcoils. The proton spectra display peaks at high concentrations (100-300 mM) assigned to betaine and choline, and other metabolite resonances including lactate at lower concentrations in the order of 10s of millimoles. The volumes examined were approximately 10 nl, over two orders of magnitude less than previously possible. In these initial experiments; the cells were unperfused and the signal intensities of the osmolytes decrease with time, a phenomenon consistent with cell swelling. This work demonstrates the technical feasibility of NMR spectroscopy of single cells, further broadening the scope of NMR spectroscopy of living tissues from application to entire living organisms (man and animal models) and isolated tissues (perfused organs and cultured assemblies of cells) and now to single cells. Magn Reson Med 44:19-22, 2000.

Acetates↗

A microcoil NMR probe for coupling microscale HPLC with on-line NMR spectroscopy.

An HPLC NMR system is presented that integrates a commercial microbore HPLC system using a 0.5-mm column with a 500-MHz proton NMR spectrometer using a custom NMR probe with an observe volume of 1.1 microL and a coil fill factor of 68%. Careful attention to capillary connections and NMR flow cell design allows on-line NMR detection with no significant loss in separation efficiency when compared with a UV chromatogram. HPLC NMR is performed on mixtures of amino acids and small peptides with analyte injection amounts as small as 750 ng; the separations are accomplished in less than 10 min and individual NMR spectra are acquired with 12 s time resolution. Stopped-flow NMR is achieved by diversion of the chromatographic flow after observation of the beginning of the analyte band within the NMR flow cell. Isolation of the compound of interest within the NMR detection cell allows multidimensional experiments to be performed. A stopped-flow COSY spectrum of the peptide Phe-Ala is acquired in 3.5 h with an injected amount of 5 micrograms.

Amino Acids↗

Multiple solenoidal microcoil probes for high-sensitivity, high-throughput nuclear magnetic resonance spectroscopy.

Two designs for incorporating multiple solenoidal microcoils into a single probe head are presented to increase the throughput of high-resolution NMR. Through a combination of radio frequency switches and low-noise amplifiers, multiple NMR spectra can be acquired in the same time as a single spectrum from a conventional probe consisting of one coil. Since this method does not compromise sensitivity with regard to the individual microcoils, throughput increases linearly with the number of coils. Only one receiver is needed, and data acquisition parameters can be optimized for each sample. Specifically, a four-coil system has been implemented for proton NMR at 250 MHz using a wide-bore magnet, with an observe volume of 28 nL for each microcoil. Signal cross-contamination was approximately 0.2% between individual coils, and simultaneous one- and two-dimensional spectra have been obtained from samples of fructose, galactose, adenosine triphosphate, and chloroquine (7 nmol of each compound). A more compact two-coil configuration has also been designed for operation at 500 MHz, with observe volumes of 5 and 31 nL for the two coils. One- and two-dimensional spectra were acquired from samples of 1-butanol (55 nmol) and ethylbenzene (250 nmol).

Image Processing, Computer-Assisted↗

Nanoliter-volume 1H NMR detection using periodic stopped-flow capillary electrophoresis.

Recent advances in the analysis of nanoliter volumes using 1H NMR microcoils have led to the application of microcoils as detectors for capillary electrophoresis (CE). Custom NMR probes consisting of 1-mm-long solenoidal microcoils are fabricated from 50-micron diameter wire wrapped around capillaries to create nanoliter-volume detection cells. For geometries in which the capillary and static magnetic field are not parallel, the electrophoretic current induces a magnetic field gradient which degrades the spectroscopic information obtainable from CE/NMR. To reduce this effect and allow longer analyte observation times, the electrophoretic voltage is periodically interrupted so that 1-min high-resolution NMR spectra are obtained for every 15 s of applied voltage. The limits of detection (LODs; based on S/N = 3) for CE/NMR for arginine are 57 ng (330 pmol; 31 mM) and for triethylamine (TEA) are 9 ng (88 pmol; 11 mM). Field-amplified stacking is used for sample preconcentration. As one example, a 290-nL injection of a mixture of arginine and TEA both at 50 mM (15 nmol of each injected) is stacked severalfold for improved concentration LODs while achieving a separation efficiency greater than 50,000. Dissolving a sample in a mixture of 10% H2O/90% D2O allows H2O to serve as the nearly ideal neutral tracer and allows direct observation of the parabolic and flat flow profiles associated with gravimetric and electrokinetic injection, respectively. The unique capabilities of CE and the rich spectral information provided by NMR spectroscopy combine to yield a valuable analytical tool, especially in the study of mass-limited samples.

Arginine↗

Limited-sample NMR using solenoidal microcoils, perfluorocarbon plugs, and capillary spinning.

This study demonstrates three improvements to mass-limited NMR using solenoidal microcoils as detectors: (1) sample confinement using liquid perfluorocarbon plugs to increase the observe factor, (2) design and incorporation of a capillary spinner to improve spectral line widths, and (3) facile sample changing via the use of a capillary insert. The probe is constructed to spin a fused silica capillary of 530 microns i.d., 700 microns o.d. inside a solenoidal coil wound around a 0.8 mm i.d., 1 mm o.d. glass capillary. The smaller capillary contains the sample, and capillaries with different samples can be exchanged easily. In high-resolution limited sample microcoil NMR studies published thus far, the length of the sample plug has been 7-10 times the length of the solenoid to avoid line broadening from volume magnetic susceptibility (chi v) mismatches at both ends of the sample. This arrangement is not efficient since it places most of the sample volume outside of the coil observe volume. It is shown here that the observe factor cannot exceed 23% if the sample plug is bracketed by air, without substantial line broadening occurring. However, if the sample is bracketed by two liquid perfluorocarbon plugs, the observe factor can be increased to 70% while maintaining high spectral resolution. This is equivalent to improving the limit of detection by a factor of 3, or reducing the total data acquisition time for a given signal-to-noise by a factor of 9. It is also shown that, for the 440-nL sample plug used in this study (bracketed by the perflurocarbon plugs), sample spinning can improve the spectral resolution from 1.5 (nonspinning) to 0.6 Hz (spinning). This corresponds to a further improvement in the limit of detection of 2.5, or just over a factor of 6 decrease in data acquisition time.

Fluorocarbons↗

Design of solenoidal microcoils for high-resolution 13C NMR spectroscopy.

Typical high-resolution natural-abundance 13C NMR experiments require milligrams of material. In this study, solenoidal microcoil direct and inverse detection probes have been designed to explore improvements in the limits of detection (LOD) for 13C NMR at 11.7 T. A direct-detection radio frequency probe with an observe volume (Vobs) of 1 microL has been developed with carbon observe, deuterium lock, and proton decouple channels. The nonspinning line width of a decoupled [3-13C]-L-alanine (99%) peak achieved is 1.3 Hz. The natural-abundance 13C3 sigma LOD for sucrose for a 90-min acquisition time is 18 micrograms (52 nmol). The 3 sigma LOD for [3-13C]-L-alanine (99%) is 375 ng (4.2 nmol) for an acquisition time less than 30 s. The inverse detection probe has proton observe and carbon decouple channels and a Vobs of 550 nL. The 3 sigma LOD for sucrose from a 1 D 13C decoupled HMQC spectrum is 1.6 micrograms (4.5 nmol) for a 14-min acquisition time.

Alanine↗

RF microcoil design for practical NMR of mass-limited samples.

This paper addresses practical issues involved in obtaining high resolution 1H NMR spectra from samples containing less than 10 nmol. Solenoidal microcoils have been constructed to: (a) assess the effects of magnetic susceptibility mismatches at 500 MHz, (b) increase the concentration sensitivity of microcoil probes, (c) incorporate a lock channel for 2D experiments and long 1D acquisitions, and (d) assess the total amount of the sample required (with respect to the coil length) to avoid line broadening due to edge effects. Compared to previously published microcoil results, sample volumes have been increased by a factor of 20 with a concomitant decrease in the required concentration (5-20 mM). Perfluorocarbon susceptibility matching remained effective at 500 MHz, allowing acquisition of high resolution NMR spectra. A lock channel has also been successfully incorporated in microcoil probes. The limits of detection for sucrose with a 10 min acquisition time were found to be 17.8 and 34.1 pmol for the single and double resonance coils, respectively. A sample length of approximately 10 times than that of the coil was required to avoid magnetic susceptibility artifacts.

Artifacts↗

A multiple echo pulse sequence for diffusion tensor imaging and its application in excised rat spinal cords.

A new imaging sequence for rapid determination of the apparent self-diffusion tensor of water was developed and tested on fixed excised rat spinal cords. To reduce the time required to determine the tensor, the sequence utilized a new single-shot approach with multiple spin echoes. An assumption of cylindrical symmetry in the sample was made, thus requiring the measurement of only four of the six unique elements of the tensor. This assumption was found experimentally to be valid, and the results obtained using the new sequence were found to be quantitatively the same as results obtained using a standard spin-echo sequence.

Animals↗

Nanoliter volume, high-resolution NMR microspectroscopy using a 60-micron planar microcoil.

Previous studies demonstrated the feasibility of using 100-microns inner diameter planar spiral inductors (microcoils) as detectors in 1H nuclear magnetic resonance (NMR) microspectroscopy. However, high-resolution NMR applications were not possible due to poor spectral resolution and low signal-to-noise ratio (SNR). These limitations in performance have now been largely overcome by using a nonconductive liquid fluorocarbon (FC-43) to minimize the effects of susceptibility mismatch between materials, and by carefully optimizing the microcoil geometry for maximum SNR. In this study, liquid samples were loaded into a fused silica capillary (75-microns inner diameter, 147-microns outer diameter). The capillary was positioned 50 microns above a 3.5-turn microcoil so that approximately 1 nL of the sample was present in the sensitive region of the microcoil. The microcoil was fabricated on a gallium arsenide substrate with an inner diameter of 60 microns, an outer diameter of 200 microns, trace width of 10 microns, trace spacing of 10 microns, and trace height of 3 microns. At 5.9 T (250 MHz) in 1H-NMR microspectroscopy experiments using a spectral width of 1 kHz, 4096 sampled data points, and a recovery delay of 1 s, a SNR of 25 (per acquisition) and a spectral linewidth of less than 2 Hz were obtained from a sample of water. These results demonstrate that planar microcoils can be used for high-resolution NMR microspectroscopy. Such coils may also be suitable for localized NMR studies at the cellular level and as detectors in capillary electrophoresis or microbore liquid chromatography.

Electric Conductivity↗