PubMed Health⌕ Search

Biomedical subjects

A Hentsch

Publications and source records attributed to A Hentsch.

6 recordsLinked to original sources

[First clinical results in a study of contrast enhanced magnetic resonance angiography with the 1.0 molar gadobutrol in peripheral arterial occlusive disease--comparison to intraarterial DSA].

PURPOSE: To assess the value of contrast enhanced (CE)-MR angiography (MRA) with 1.0 molar Gadobutrol (Schering, Germany) in comparison to intraarterial DSA in peripheral arterial occlusive disease (PAOD). MATERIALS AND METHODS: Within 48 hours, 30 symptomatic patients with PAOD were examined by CE-MRA (Gadobutrol dose 0.2-0.3 mmol/kg body weight) and DSA. For CE-MRA, a 1.5 T magnet (Vision, Siemens, Germany) was used (FA 35 degrees, TR/TE 4.6/1.8 ms, FOV 400 mm, matrix 230 x 512, total acquisition time 81 sec). Two radiologists evaluated a total of 600 vessel segments for stenotic lesions and image quality (1 = not visible to 5 = excellent). Treatment was independently planned on the basis of the MRA and DSA findings. RESULTS: The Kendall's tau-b coefficient was 0.92 for overall stenotic grading, and 0.92, 0.93 and 0.92, respectively, for the vascular flow in the iliac, femoropopliteal and crural arteries. Sensitivity, specificity, negative and positive predictive value, and accuracy were, respectively, 94, 97, 98 and 92, 96 % for > 50 % stenoses, 95, 99, 99, 95 and 99 % for iliac arteries, 96, 98, 98%, 94 and 97 % for femoropopliteal arteries, and 92, 94, 96, 89 and 94 % for crural arteries. Therapy planning by MRA and DSA coincided in 51 of 54 cases. No relevant adverse event occurred. CONCLUSION: CE-MRA with 1.0 molar Gadobutrol is highly efficient in diagnosing peripheral arterial occlusive disease and correlates excellently with DSA.

Aged↗

Extraspinal dural arteriovenous fistula in a patient with lipomyelodysplasia: value of MRI and MRA.

Spinal dural arteriovenous fistulae are extremely rare in spinal dysraphism. A fistulous malformation within a lipomyelomeningocele has not been reported previously. A 50-year-old man presented with progressive paraparesis and bladder dysfunction. MRI revealed a large lumbar lipomyelomeningocele. A vascular malformation was indicated by abnormal signal in the thoracolumbar spinal cord and dilated perimedullary veins. Phase-contrast MRA demonstrated only the slow-flow veins of the fistula and an intradural ascending vein. Contrast-enhanced ultra-fast MRA gave excellent delineation of all parts of the fistula within the dysraphic lesion.

Arteriovenous Fistula↗

Development of an endoscopic navigation system based on digital image processing.

We developed a new system to couple the endoscope to an optical position measurement system (OPMS) so that the image frames from the endoscope camera can be labeled with the accurate endoscopic position. This OPMS is part of the EasyGuide Neuro navigation system, which is used for microsurgery and neuroendoscopy. Using standard camera calibration techniques and a newly developed system calibration, any 3-dimensional (3-D) world point can be mapped onto the view from the endoscope. In particular, we can display the coordinates of any anatomical landmark of the patient as it is viewed from the current position of the camera. This and other image-processing techniques are applied to the labeled frame sequence in order to offer the neurosurgeon a variety of control modules that increase the safety and flexibility of neuroendoscopic operations. Several modules, including a new motion alarm system and the "tracking" and "virtual map" modules, were tested in a human cadaveric model using the frontal and occipital approaches. A failure rate of 8.6% was experienced during testing of the first version of the software, but the second version was 100% successful. Thus, an endoscopic navigation system based on digital image processing has been developed that could be a revolutionary advance in image-guided surgery.

Cadaver↗

[3-D-TONE magnetic resonance angiography in the detection of intracranial aneurysms compared with digital subtraction angiography. A prospective study].

PURPOSE: To evaluate the efficiency and accuracy of the optimized 3-D-MT-TONE-magnetic resonance angiography (MRA) with that of intraarterial digital subtraction angiography (DSA) in the detection of intracranial aneurysms. MATERIAL AND METHODS: From March 1994 to March 1995 30 patients with 38 aneurysms were prospectively subjected to MRA as well as to DSA. Respiratory insufficient patients were excluded from MRA. RESULTS: The aneurysm size ranged from 3-50 mm with an average size of 9 mm. Correct diagnosis was done in 33 aneurysms (86.8%) in 26 of the patients. In 4 patients (13.3%) with 5 aneurysms, the blinded readers made an incorrect diagnosis due to degradation of image quality. One (2.6%) aneurysm was falsely described via MRA as well as via DSA. The sensitivity was 86.8%. In the control group of 30 patients three aneurysms were found, therefore the specificity was 90% and we could calculate a positive predictive value of 97.1%, a negative predictive value of 84.4% and a correct diagnosis of 90.1%. CONCLUSION: Our results show that MT-TONE-MRA is a useful non-invasive technique with improved vascular detail and vascular background for detection of intracranial aneurysm. Further technical improvements are necessary for better visualisation of pathological findings in the carotid siphon, where only 60% of the aneurysms could be clearly detected.

Adult↗