PubMed Health⌕ Search

PubMed · 9888200

Development of an endoscopic navigation system based on digital image processing.

Abstract

We developed a new system to couple the endoscope to an optical position measurement system (OPMS) so that the image frames from the endoscope camera can be labeled with the accurate endoscopic position. This OPMS is part of the EasyGuide Neuro navigation system, which is used for microsurgery and neuroendoscopy. Using standard camera calibration techniques and a newly developed system calibration, any 3-dimensional (3-D) world point can be mapped onto the view from the endoscope. In particular, we can display the coordinates of any anatomical landmark of the patient as it is viewed from the current position of the camera. This and other image-processing techniques are applied to the labeled frame sequence in order to offer the neurosurgeon a variety of control modules that increase the safety and flexibility of neuroendoscopic operations. Several modules, including a new motion alarm system and the "tracking" and "virtual map" modules, were tested in a human cadaveric model using the frontal and occipital approaches. A failure rate of 8.6% was experienced during testing of the first version of the software, but the second version was 100% successful. Thus, an endoscopic navigation system based on digital image processing has been developed that could be a revolutionary advance in image-guided surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Scholz, W Konen, S Tombrock, B Fricke, L Adams, M von Düring, A Hentsch, L Heuser, A G Harders. 1998. Development of an endoscopic navigation system based on digital image processing.. https://doi.org/10.1002/(sici)1097-0150(1998)3%3A3%3C134%3A%3Aaid-igs5%3E3.0.co%3B2-t

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A population-based study of cancer incidence in solid organ transplants from donors at various risk of neoplasia.

A population-based cohort study of recipients of organs from donors with a recognized history or active cancer has been conducted by linking the Italian National Registry of Transplanted Patients and the National Registry of Donors with Neoplasia Risk. Between 2002 and 2004, 8,198 solid organ transplants have been performed in Italy, 108 of them with organs from 59 cadaveric donors with various risk of neoplasia. There were two reported cases of nonmelanoma skin cancer during the follow up of the transplanted patients, which lasted 27.6+/-11.3 months (234 patient-years). In our study, recipients of organs from donors with various degree of neoplasia risk are exposed to a low risk of cancer transmission.

Cadaver↗

[Primary stability of the capsule-labrum complex after reconstruction with the Mitek Bioknotless anchor system in human cadaver models].

BACKGROUND: This study examines the postoperative stability of the Mitek Bioknotless anchor system with biomechanical draw-out pulling in human cadaver shoulders. METHOD: With simulation of anterior shoulder dislocation a test group (n=10, Ø 45 years) was tested against a native group (n=8, Ø 47 years). All shoulders were dissected up to the passive stabilizers. In the test group an artificial Bankart lesion was created and repaired with three Mitek Bioknotless anchors. The humeri of both groups were fixed in 60 degrees glenohumeral abduction and 90 degrees external rotation and then dislocated in a ventral direction. For evaluation purposes the ultimate draw-out strength, mode of failure, translation of humeral head, capsular slope, and bone density in the test group were measured. RESULTS: In the test group the ultimate strength was a median of 937 N (min. 554 N, max. 1,294 N) with 28 bony anchor dislocations, 1 suture rupture, and 1 capsular rupture, and in the native group with 6 Bankart and 2 HAGL lesions it was 1,214 N (708 N, 1,471 N). The bone density showed a positive correlation to the draw-out strength regarding cortical density and total density. CONCLUSION: Regarding the high draw-out strength the Mitek Bioknotless anchor system provides enough stability for early functional treatment.

Cadaver↗