Overexposure analysis of pulsed distributed feedback laser source.

The goal of this study is to assess the risk of overexposure, when DFB dye laser is used for medical treatment in pulsed mode operation. Results of experimental study showing an unexpected rise of energy in pulses of distributed feedback dye laser (DFDL) output due to temperature phase gratings in dye cell during passively Q switched and mode-locked operation is reported. This unintended increase in the number of pulses, pulse duration, per pulse energy may cause side effects, when used for selective photothermolysis. To probe this phenomenon the most commonly used Rh6G dye was excited with 10-20 pulses of second harmonic of a passively Q switched and mode-locked Nd:yttrium-aluminum-garnet(YAG) laser. The outputs of DFDL and Nd:YAG laser were recorded by an Imacon-675 streak camera. The peak of DFDL output pulses was found delayed proportionally from the peak of the Nd:YAG pulses by more than an interpulse period of excitation laser. A computer program was used to simulate the experimentally measured results to estimate the thermal decay constants and energy retained by medium. The delay between peaks of Nd:YAG (input) and DFDL (output) pulses was found to vary from 10 to 14 ns for various cavity lengths. It was interesting to note that for smaller inter-pulse periods the effect of gradual gain buildup satisfied the threshold conditions for some of the pulses that otherwise cannot lase. This may lead to unintended increase in energy fluence causing overexposure-induced bio effects.

Feedback↗

A comparative study of positive pressure ventilation via laryngeal mask airway and endotracheal tube.

OBJECTIVE: To investigate the use of Laryngeal Mask Airway (LMA) and its comparison with the endotracheal tube for positive pressure ventilation. SETTING: A tertiary care teaching hospital. METHODS: Fifty adult ASA I and II patients undergoing peripheral limb surgery were randomly allocated to 2 groups for LMA or endotracheal tube insertion. A standardized anaesthetic technique was used. The groups were then compared regarding haemodynamic changes on insertion as well as removal of LMA and ETT and any complications that occurred were noted. RESULTS: The haemodynamic response to insertion was significantly attenuated (p < 0.05) in LMA group as compared to ETT group. The cardiovascular response to extubation was not significantly different between the groups. A higher incidence of coughing and mild hypoxaemia at extubation was noted in ETT group as compared to LMA group (p < 0.05) and blood was detected in 4 cases after LMA removal. CONCLUSION: It is concluded that the use of LMA during positive pressure ventilation is safe in selected cases. There is an attenuated haemodynamic response to insertion of LMA as compared to endotracheal tube which will be beneficial in certain patients e.g., those with ischaemic heart disease, vascular disease and hypertensives.

Adult↗