PubMed Health⌕ Search

Biomedical subjects

A Laghi

Publications and source records attributed to A Laghi.

At least 19 recordsLinked to original sources

The role of circulating tumor DNA (ctDNA) to detect minimal residual disease in locally advanced gastroesophageal carcinoma: the BUTTERFLY study.

BACKGROUND: Despite advances in perioperative and neoadjuvant strategies, patients with locally advanced gastroesophageal cancers remain at high risk of recurrence after curative intent treatment. No validated biomarkers are available to detect minimal residual disease (MRD) or to guide post-operative risk-adapted management. Circulating tumor DNA (ctDNA) has emerged as a noninvasive tool for disease monitoring; single-parameter or tumor-informed assays, however, may lack sensitivity in low-tumor burden settings. Multimodal, tumor-agnostic approaches may overcome these limitations. METHODS: The BUTTERFLY study is a prospective, multicenter observational study enrolling patients with stage II-III gastric, gastroesophageal junction, or esophageal cancer treated with perioperative chemotherapy or neoadjuvant chemoradiotherapy followed by surgery. It evaluates the diagnostic performance and prognostic value of an academic, tumor-agnostic, multimodal ctDNA assay for MRD detection and prognostic stratification. Serial plasma samples are collected from baseline through post-operative follow-up and at relapse. Cell-free DNA is analyzed using the Agnostic Liquid Biopsy Multimodal Advancement (ALMA) platform, integrating tumor fraction estimation, somatic copy number alterations, fragmentomic features, single-nucleotide variants, and whole-genome methylation profiling. Multimodal features are combined with clinical variables using machine learning-based models to enhance MRD detection and relapse risk stratification. The primary endpoint includes sensitivity and specificity of ALMA-defined ctDNA/MRD status at the 4-8 weeks after surgery landmark, whereas secondary endpoints assess diagnostic performance at other time points and associations between ctDNA status and dynamics with disease-free survival, overall survival, treatment response, and lead time to recurrence. FUTURE PERSPECTIVES: If validated, this tumor-agnostic, multimodal ctDNA approach may enable earlier molecular relapse detection and support personalized post-operative management strategies.

circulating tumor DNA (ctDNA)↗

Abdominal tuberculosis with pancreatic involvement: a case report.

A case of abdominal tuberculosis with pancreatic involvement is described. A 27-year-old Italian male, with no known cause of immunodeficiency and with no evidence of pulmonary tuberculosis, was admitted to our division because of acute pancreatitis. Abdominal imaging revealed a large 'tumour-like' mass in the pancreas head compressing the distal choledochous, and multiple adenopathy. Histological examination of multiple specimens removed during explorative laparotomy revealed granulomas with giant cells, caseous necrosis, and positive Ziehl-Neelsen staining. Tissue culture was positive for Mycobacterium tuberculosis. Once specific medical treatment was started, the pancreatic damage completely resolved.

Adult↗

Contrast enhanced magnetic resonance imaging of the terminal ileum in children with Crohn's disease.

BACKGROUND AND AIMS: Recently, magnetic resonance imaging (MRI) has been introduced in the diagnosis of patients with inflammatory bowel disease (IBD). However, it is still rarely reported in paediatric IBD. We studied the diagnostic value of gadolinium enhanced MRI in revealing inflammation of the distal ileum in children with Crohn's disease (CD) and in differentiating them from patients with other inflammatory diseases of the gut. MRI was performed using a polyethylene glycol (PEG) solution as oral contrast agent to distend the small bowel (CE-PEG-MRI). SUBJECTS AND METHODS: Seventy five consecutive patients (median age 13.6 years, range 8-17) with suspected CD underwent ileocolonoscopy with biopsy and CE-PEG-MRI. CD activity was measured by the paediatric Crohn's disease activity index (PCDAI). CE-PEG-MRI was evaluated with an overall score calculated, taking into account both wall thickness and contrast enhancement. RESULTS: Active CD with distal ileitis was diagnosed in 26 cases, active ulcerative colitis (UC) in 18, and spondyloarthropathy and indeterminate ileocolitis in 11; 20 children served as controls. In all CD patients, CE-PEG-MRI revealed a marked ileal involvement with increased wall thickness and parietal contrast enhancement and showed a high concordance with endoscopy and histology, whereas the test was negative in all controls. Of the 18 UC patients, CE-PEG-MRI was negative in 15 and showed a mild parietal contrast enhancement of the terminal ileum in only three of seven patients with backwash ileitis. Among the group of spondyloarthropathy patients, six had mucosal erosions and five mild superficial ileitis: CE-PEG-MRI was negative in four and revealed only mild parietal contrast enhancement of the ileal wall in seven. CE-PEG-MRI did not show an increase in wall thickness of the distal ileum in any of the UC or spondyloarthropathy patients. The sensitivity and specificity of CE-PEG-MRI related to the presence of erosive ileitis, as documented by endoscopy, were 84% and 100%, respectively. In addition, the test correlated markedly with endoscopy and histology in the entire population (r=0.94; r=0.95, respectively) as well as with the PCDAI in CD patients (r=0.91). CONCLUSIONS: In children with active CD, CE-PEG-MRI is a very sensitive and specific test for the detection of distal ileitis and for differentiation from other inflammatory diseases of the gut. The test could also be useful for the firstline diagnostic approach in children with suspected CD. The high correlation of CE-PEG-MRI with ileal endoscopy and histology as well as with PCDAI makes this test of great interest for future studies as a tool for monitoring the clinical course and the effect of therapy in CD patients.

Adolescent↗

High-resolution multidetector CT in the preoperative evaluation of patients with renal cell carcinoma.

OBJECTIVE: The purpose of our study was to evaluate the accuracy of multidetector CT (MDCT) using a high-resolution protocol in the preoperative assessment of patients with renal cell carcinoma who are possible candidates for nephron-sparing surgery. MATERIALS AND METHODS: Forty patients with suspected renal cell carcinoma underwent MDCT. Contrast-enhanced acquisitions were obtained during arterial, nephrographic, and urographic phases using a thin-slice protocol. One-millimeter-thick source images were evaluated by two observers on a dedicated workstation for the identification and characterization of the tumor, presence of a pseudocapsule or invasion of perirenal fat, involvement of adrenal glands or surrounding tissues, presence of satellite lesions within Gerota's fascia, infiltration of renal vein and inferior vena cava, involvement of lymph nodes, and presence of distant metastases. Imaging findings were compared with surgical specimens using criteria from the Robson and TNM classification systems. RESULTS: The presence and size of all lesions were correctly shown in all patients. In evaluating Robson stage I of renal cell carcinoma, we were able to diagnose fat infiltration on 1-mm scans with 96% sensitivity, 93% specificity, and 95% accuracy; the positive and negative predictive values were, respectively, 100% and 93%. One hundred percent accuracy was achieved in staging high-grade lesions. CONCLUSION: High-resolution MDCT is accurate in the preoperative evaluation of patients with renal cell carcinoma.

Adult↗

Multislice spiral computed tomography in diagnosis and staging of pancreatic carcinoma: preliminary experience.

BACKGROUND: Computed tomography has become the modality of choice for preoperative evaluation of patients with suspected pancreatic carcinoma, although some limitations are well known. AIMS: To evaluate use of multislice spiral computed tomography in preoperative assessment of patients with suspected pancreatic carcinoma using volume-rendering as image reconstruction algorithm. PATIENTS: A total of 27 patients with suspected pancreatic carcinoma underwent multislice spiral computed tomography examination. METHODS: All studies were performed on a multislice computed tomography scanner with the following parameters: slice collimation, 1 mm; slice thickness, 1.25 mm; reconstruction interval, 1 mm; scan time, 22-25 sec; mAs, 165. Scans were acquired with a biphasic technique with a 30-sec (pancreatic phase) and a 70-sec (portal venous phase) delay time after start of contrast material injection. Diagnostic confirmation was obtained with surgical exploration, percutaneous biopsy, or with a combination of follow-up imaging studies. RESULTS: Multislice spiral computed tomography yielded correct diagnosis of pancreatic carcinoma in 20 cases (sensitivity, 95%; specificity, 100%). Positive predictive values for resectability and unresectability were 80% and 93.3%, respectively. Three-dimensional volume-rendered images improved diagnostic confidence in the depiction of major vascular structures. Two cases of anomalous origin of hepatic artery were also identified with volume-rendered images. CONCLUSIONS: Multislice technology improves accuracy of spiral computed tomography for diagnosis and staging of pancreatic carcinoma.

Algorithms↗

Computed tomographic colonography (virtual colonoscopy): blinded prospective comparison with conventional colonoscopy for the detection of colorectal neoplasia.

BACKGROUND AND STUDY AIMS: Computed tomographic colonography (CTC), also known as virtual colonoscopy, is a recently introduced imaging modality for the detection of colorectal neoplasia. The aim of our study was to evaluate the performance of CTC in a blinded comparison with conventional colonoscopy. PATIENTS AND METHODS: A total of 66 consecutive, symptomatic patients underwent spiral computed tomography (CT) examination after standard bowel preparation. CT images were analyzed and subsequently compared with conventional colonoscopy findings. RESULTS: Conventional colonoscopy detected 15 colorectal carcinomas and 52 polyps. CTC correctly identified all carcinomas, 13 of 14 polyps greater than 10.0 mm (sensitivity 92.8 %; 95 % confidence interval (95 % CI); 77 - 100), 11 of 13 polyps between 6.0 and 9.0 mm (sensitivity 84.6 %; 95 % CI; 62 - 100), and six of 25 polyps smaller than 5.0 mm (sensitivity 24 %; 95 % CI; 6 - 42). The per-patient sensitivity and specificity were 93.7 % and 94.1 %, respectively. CONCLUSIONS: Computed tomographic colonography is an accurate imaging modality for the detection of colorectal neoplasia, especially for lesions larger than 6.0 mm in diameter.

Adult↗

Multiphase multislice spiral CT for liver assessment: optimization in cirrhotic patients.

PURPOSE: The aim of our study was to optimize a multiphase study protocol with double arterial phase acquisition in a patient population with cirrhosis using a multislice spiral CT scanner. MATERIAL AND METHODS: Thirteen patients (10 males, 3 females, mean age 58 years) with known cirrhosis were selected for the study. All examinations were performed with a multislice spiral CT scanner (Somatom Plus 4 Volume Zoom; Siemens, Erlangen, Germany). Images were acquired using the following parameters: slice collimation, 2.5 mm; slice thickness, 3.0 mm; table feed, 10.8 mm/sec; mAs, 165; kVp, 120. Four scans of the hepatic parenchyma were obtained after the administration of contrast material. The first pass (early arterial phase) was acquired in a cranio-caudal direction; the second pass (late arterial phase) was acquired in a caudo-cranial direction. Early and late arterial phases were obtained during a single breath-hold of 24 sec. The third pass (portal-venous phase) was acquired with a 60-sec delay time after contrast material injection. The fourth pass (equilibrium phase) was obtained with a 180-sec delay time. Optimal delay time to start CT acquisition was assessed by means of injecting a 20-ml minibolus of contrast material and by performing serial dynamic scans every two sec at the level of the hepatic hilum. The time of peak aortic enhancement was used as the start time for the early arterial phase. Attenuation values of aorta, portal vein, and liver parenchyma were calculated in all the acquisitions. CT data from the early arterial phase were used to produce three-dimensional angiographic images of the hepatic and mesenteric circulation. RESULTS: The enhancement of liver parenchyma progressively increased from pre-contrast phase to portal-venous and equilibrium phases. The highest difference in attenuation values between aorta and hepatic parenchyma was observed during the second acquisition (early arterial phase, 247.78+/-106.29 HU) rather than during the third acquisition (late arterial phase, 185.72+/-109.23 HU); this difference was statistically significant (p<0.01). DISCUSSION: Results from our study emphasize the potential of multiphase acquisition in the evaluation of cirrhotic patients; in particular, the use of an early arterial phase is useful for studying the hepatic and mesenteric vascular anatomy, whereas the late arterial and the portal-venous phases are of paramount importance for adequate evaluation of liver parenchyma and focal lesions. Further studies are needed to evaluate whether the benefits deriving from double arterial phase acquisition would justify the increase in cost and patient radiation exposure.

Contrast Media↗

Magnetic Resonance Imaging of the anal canal using high resolution sequences and phased array coil: visualization of anal sphincter complex.

PURPOSE: To assess the normal anatomy of the anal sphincter complex using high-resolution MR imaging with phased -array coil. MATERIAL AND METHODS: Twenty patients, 13 males and 7 females, ranging in age between 27 and 56 years underwent MRI evaluation of the pelvic region, using a superconductive 1.5 T magnet (maximum gradient strength, 25 mT/m; minimum rise time 600 microseconds, equipped with phased-array coil. High-resolution T2-weighted Turbo Spin Echo sequences (TR, 4055 ms; TE, 132 ms; matrix 390x512; in-plane resolution, 0.67x0.57 mm) were acquired on multiple axial, sagittal and coronal planes. Images were reviewed by two experienced gastrointestinal radiologists in order to evaluate the normal anal sphincter complex. RESULTS: Optimal image quality of the anal sphincter complex was obtained in all cases. Different muscular layers were observed between the upper and lower aspects of the anal canal. In the lower part of the anal canal, internal and external sphincter muscles could be observed; in the upper part, puborectal and internal sphincter muscles were depicted. Good visualization of intersphincteric space, levator ani muscle and ischioanal space was also obtained in all cases. CONCLUSIONS: High-resolution MR images with phased-array coil provide optimal depiction of the anal canal and the anal sphincter complex.

Adult↗

Multislice spiral computed tomography angiography of mesenteric arteries.

The introduction of multislice technology has improved and expanded the clinical applications of computed tomography angiography (CTA), and it is now possible to detect subtle vascular abnormalities. We optimised a high resolution CTA protocol to study the anatomy of mesenteric arteries with a multislice spiral CT scanner. We showed that multislice CTA produces images of high quality, with excellent anatomical visualisation of the main mesenteric trunks, and small collateral vessels. CTA may facilitate the diagnosis of vascular diseases, such as chronic mesenteric ischaemia, as well as acute disorders such as gastrointestinal bleeding.

Adult↗

Duodenal pancreatic heterotopy diagnosed by magnetic resonance cholangiopancreatography: report of a case.

We describe herein the case of a heterotopic pancreas that caused stenosis in the second portion of the duodenum. A 46-year-old man presented with upper abdominal pain and a 12-month history of intermittent vomiting. There was no history of melena, hematochezia, hematemesis, clay-colored stools, jaundice, or hepatitis and he did not describe any food dyscrasias, although fatty foods and alcohol seemed to make the symptoms worse. No specific medication or change in position relieved the pain. An initial diagnosis of chronic pancreatitis with multiple pseudocysts was made on the basis of elevated serum amylase and lipase levels, and abdominal ultrasonography and computed tomography (CT) findings. Medical treatment with octreotide was given for 8 weeks, but without any marked effect. Double-contrast barium examination and esophagogastroduodenoscopy were not diagnostic. Magnetic resonance (MR) cholangiopancreatography revealed findings indicative of cystic dystrophy of a heterotopic pancreas (CDHP), and an endoscopy supported this diagnosis. A pancreatoduodenectomy was performed and pathological examination confirmed a diagnosis of CDHP. In our opinion, MR cholangiopancreatography is the diagnostic tool of choice when CDHP is suspected.

Cholangiopancreatography, Endoscopic Retrograde↗

Multislice CT colonography: technical developments.

The introduction of multislice spiral computed tomography (CT) offers increased spatial resolution along the longitudinal axis, resulting in improved image quality, and dramatically reduced acquisition times, with the capability of examining large anatomic regions in a single breath hold. Dedicated protocols are still under optimization to reduce radiation exposure and to take full advantage of the new technology. This article presents a review of the literature; the impact of multislice CT on virtual colonoscopy is also discussed.

Colon↗

Three-dimensional contrastless varicography by spiral computed tomography.

OBJECTIVE: to report and discuss preliminary results obtained in varicose limbs by means of a volume rendering (VR)-computed tomography (CT) technique without contrast medium injection. MATERIALS AND METHODS: VR-CT and duplex sonography (US) were performed to visualise the superficial veins of the lower extremity in eight healthy and 12 varicose limbs. RESULTS: VR-CT clearly demonstrated the 3D arrangement of the superficial veins and visualised small sized veins which were not visible at US examination. CONCLUSIONS: VR-CT is not suitable for routine evaluation of varicose limbs. VR-CT 3D reconstructions may be useful in the evaluation of atypical varicosis. Further studies are needed to define the role of VR-CT in deep venous disease.

Adult↗

[Diffusion-weighted echo-planar sequences for the evaluation of the upper abdomen: technique optimization].

PURPOSE: To optimize the technique for the evaluation of molecular diffusion in the abdomen. MATERIAL AND METHODS: Fifteen healthy volunteers, 6 males and 9 females, ranging in age between 24 and 31 years underwent an MRI evaluation of the upper abdomen, using a superconductive 1.5T magnet (maximum gradient strength, 25 mT/m; minimum rise time 600 ms), equipped with phased array abdominal multicoil. Diffusion study was performed with a single-shot Inversion Recovery Spin-Echo Echo-planar sequence (IR-SE-EPI) with the following parameters: TR = infinite; TE=101 ms; matrix 128 yen 128; receiver bandwidth 2080 Hz/pixel; slices: n.20; slice thickness: 8 mm; acquisition time: 5.41 s. For diffusion weighting the following b values were employed: b=30 mm/s2, b=300 mm/s2 e b=500 mm/s2. Both qualitative and quantitative (calculation of linear regression analysis and of apparent diffusion coefficient) image analysis was performed. RESULTS: Image quality was graded as diagnostic in all the cases. Image quality decreased with the increase of b values: at low b values, the anatomy of upper abdominal organs was easily recognized, whereas, at high b values, the same organs could not be adequately assessed unless the images were compared with those obtained with low b values. Magnetic susceptibility artifacts were observed in all the cases; no significant chemical-shift artifacts were observed as the fat saturation pre-pulse was employed. Quantitative analysis demonstrated an apparent diffusion coefficient of 1.58 s/mm2 for the liver, 1.61 s/mm2 for the spleen and 5,14 s/mm2 for the gallbladder. A statistically significant difference (p<0.001) was observed between parenchymatous organs (liver and spleen) and gallbladder, presenting as a stationary fluid. CONCLUSIONS: Diffusion-weighted MR sequences may be implemented for abdominal studies, but the optimization of same parameters is slightly different compared with neuroradiologic applications. The potential applications are interesting above all as regards the characterization of focal liver lesions. Further developments are awaited in both sequence optimization (greater stability and lower sensitivity to magnetic susceptibility artifacts) and data analysis, with more complex algorithms able to better quantify the real diffusion coefficient.

Abdomen↗

Analysis of a follow-up program for anal canal carcinoma.

The ideal follow-up program for anal canal cancer remains unclear and controversial. We hereby describe an extensive follow-up program for anal canal carcinoma in order to evaluate which examinations and which diagnostic techniques really had impact on survival and management. We evaluated 25 patients with anal canal carcinoma. Local excision (LE) was performed in 5 patients, radiochemotherapy (RCT) in 13, radiochemotherapy and local excision (RCTE) in 7. Mean follow-up time was 6.3 years (range 20 months-11 years). The follow-up program included clinical examination, serum tumor markers evaluation, transrectal ultrasonography (TRUS), anoscopy with either mucosal or by Tru-cut needle multiple biopsies, standard chest X-ray and hepatic-inguinal ultrasonography, endoanal magnetic resonance imaging and in some cases total-body skeletal scintigraphy. A large multicentered randomized and prospective trial is surely lacking and should be undertaken as soon as possible. Our results suggest that an effective local control, rather than a higher survival is the reachable goal at present for anal canal carcinomas. However, further steps should be made to achieve better results. After this experience we propose a more semplified follow-up protocol which consists in performing only rectal examination, endoscopy, Tru-cut needle biopsies and TRUS for local control and inguinal ultrasound and TC to evidence distant metastases.

Aged↗

[Multislice spiral CT angiography in the evaluation of the anatomy of splanchnic vessels: preliminary experience].

PURPOSE: The aim of this study was to optimize the protocol for multislice spiral CT angiography and to assess the ability of the technique to detect the anatomy of splanchnic vessels, using volume rendering as reconstruction algorithm. MATERIAL AND METHODS: The anatomy of splanchnic vessels was studied in 19 patients (11 men, 8 women, age range 38-83 years) undergoing CT of the abdomen and pelvis. All examinations were performed with a multislice spiral CT scanner (Somatom Plus 4 Volume Zoom; Siemens, Erlangen, Germany) using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 8 mm/sec; reconstruction interval, 1 mm; mAs, 120; kVp, 120. Before the study, the patients received 800 ml of water as oral contrast agent to opacify the stomach and small bowel. A nonionic contrast medium (130-140 ml; Xenetix 350, Guerbet, Aulnay-Sous-Bois, France) was infused intravenously at a rate of 3-5 ml/sec. Two scans of the abdomen and pelvis were obtained at 20-25 sec (arterial phase) and 60-65 sec (venous phase) after starting contrast medium injection. Image elaboration was performed using Vitrea 2.2 (Vital Images; Minneapolis, Minn., USA), a software with volume-rendering capabilities. RESULTS: All major arterial (celiac trunk, superior mesenteric artery, and inferior mesenteric artery) and venous (portal vein, superior mesenteric vein, inferior mesenteric vein, and splenic vein) vessels could be evaluated with excellent detail in all patients. Side branches, including small collaterals, could also be easily visualized. Volume rendered images always provided better understanding of the 3D anatomic relationships among splanchnic vessels and surrounding organs. DISCUSSION AND CONCLUSIONS: Multislice spiral CT angiography allows for optimal depiction of the anatomy of splanchnic vessels. It can be anticipated that the clinical applications of this imaging modality in the study of splanchnic vessels will be greatly expanded. However, further studies are necessary to rigorously compare the results of multislice spiral CT angiography with conventional angiography in terms of diagnostic accuracy.

Adult↗

[Optimization of the technique of virtual colonoscopy using a multislice spiral computerized tomography].

PURPOSE: To optimize scanning parameters for virtual colonoscopy utilizing a multislice Helical CT scanner in an in vitro study (using a homemade colonic phantom) and in a preliminary clinical study. MATERIAL AND METHODS: A colonic phantom was built using a plastic tube and 12 plastiline polyps were placed inside. The colonic phantom was studied with a multislice Helical CT scanner. Axial images were obtained with the phantom parallel to the long axis of the moving table (in order to simulate the evaluation of ascending and descending colon): oblique images were acquired with the phantom at 45 degrees relative to the long axis of the moving table (in order to simulate the evaluation of sigmoid colon and colonic flexures). Four different scanning protocols were tested: 1) slice collimation, 5 mm; slice width, 7 mm; table speed, 25 mm; reconstruction index, 5 mm; 2) slice collimation, 2.5 mm; slice width, 3 mm; table speed, 15 mm; reconstruction index, 3 mm; 3) slice collimation, 1 mm; slice width, 1.25 mm; table speed, 5 mm; reconstruction index, 1 mm; 4) slice collimation, 1 mm; slice width, 1.25 mm; table speed, 4 mm; reconstruction index, 1 mm. Quantitative analysis consisted in evaluation of the number of identified polyps and polyp size along the longitudinal axis. Qualitative analysis consisted in the evaluation of image artifacts and quality of 3D reconstructed images (step artifacts and polyp geometry distortion). This preliminary clinical study was performed in 12 patients (7 men and 5 women) who underwent multislice Helical CT colonography. We selected patients with clinical indications for conventional colonoscopy or after unsuccessful conventional colonoscopy. RESULTS: Multislice Helical CT colonography was 100% sensitive in the detection of all polyps and in all scanning protocols. With oblique scans, only a 3-mm polyp was missed during protocol 1 (sensitivity: 92%). Polyp geometry distortion was observed on longitudinal reconstructions, whereas no distortion was seen on axial images. Image quality was graded as optimal for protocols 2, 3, and 4; protocol 1 was graded as good on transverse scans and as poor on oblique scans. In our preliminary clinical study, two colonic carcinomas and three polyps were identified. CONCLUSIONS: At present, the introduction of multislice technology in virtual colonoscopy permits to improve spatial resolution and image definition. The actual clinical advantage, in terms of increased diagnostic accuracy, needs further investigation in larger clinical studies.

Artifacts↗