PubMed Health⌕ Search

Biomedical subjects

A Laghi

Publications and source records attributed to A Laghi.

At least 37 records · Page 2Linked to original sources

Three-dimensional contrastless varicography by spiral computed tomography.

OBJECTIVE: to report and discuss preliminary results obtained in varicose limbs by means of a volume rendering (VR)-computed tomography (CT) technique without contrast medium injection. MATERIALS AND METHODS: VR-CT and duplex sonography (US) were performed to visualise the superficial veins of the lower extremity in eight healthy and 12 varicose limbs. RESULTS: VR-CT clearly demonstrated the 3D arrangement of the superficial veins and visualised small sized veins which were not visible at US examination. CONCLUSIONS: VR-CT is not suitable for routine evaluation of varicose limbs. VR-CT 3D reconstructions may be useful in the evaluation of atypical varicosis. Further studies are needed to define the role of VR-CT in deep venous disease.

Adult↗

[Diffusion-weighted echo-planar sequences for the evaluation of the upper abdomen: technique optimization].

PURPOSE: To optimize the technique for the evaluation of molecular diffusion in the abdomen. MATERIAL AND METHODS: Fifteen healthy volunteers, 6 males and 9 females, ranging in age between 24 and 31 years underwent an MRI evaluation of the upper abdomen, using a superconductive 1.5T magnet (maximum gradient strength, 25 mT/m; minimum rise time 600 ms), equipped with phased array abdominal multicoil. Diffusion study was performed with a single-shot Inversion Recovery Spin-Echo Echo-planar sequence (IR-SE-EPI) with the following parameters: TR = infinite; TE=101 ms; matrix 128 yen 128; receiver bandwidth 2080 Hz/pixel; slices: n.20; slice thickness: 8 mm; acquisition time: 5.41 s. For diffusion weighting the following b values were employed: b=30 mm/s2, b=300 mm/s2 e b=500 mm/s2. Both qualitative and quantitative (calculation of linear regression analysis and of apparent diffusion coefficient) image analysis was performed. RESULTS: Image quality was graded as diagnostic in all the cases. Image quality decreased with the increase of b values: at low b values, the anatomy of upper abdominal organs was easily recognized, whereas, at high b values, the same organs could not be adequately assessed unless the images were compared with those obtained with low b values. Magnetic susceptibility artifacts were observed in all the cases; no significant chemical-shift artifacts were observed as the fat saturation pre-pulse was employed. Quantitative analysis demonstrated an apparent diffusion coefficient of 1.58 s/mm2 for the liver, 1.61 s/mm2 for the spleen and 5,14 s/mm2 for the gallbladder. A statistically significant difference (p<0.001) was observed between parenchymatous organs (liver and spleen) and gallbladder, presenting as a stationary fluid. CONCLUSIONS: Diffusion-weighted MR sequences may be implemented for abdominal studies, but the optimization of same parameters is slightly different compared with neuroradiologic applications. The potential applications are interesting above all as regards the characterization of focal liver lesions. Further developments are awaited in both sequence optimization (greater stability and lower sensitivity to magnetic susceptibility artifacts) and data analysis, with more complex algorithms able to better quantify the real diffusion coefficient.

Abdomen↗

Analysis of a follow-up program for anal canal carcinoma.

The ideal follow-up program for anal canal cancer remains unclear and controversial. We hereby describe an extensive follow-up program for anal canal carcinoma in order to evaluate which examinations and which diagnostic techniques really had impact on survival and management. We evaluated 25 patients with anal canal carcinoma. Local excision (LE) was performed in 5 patients, radiochemotherapy (RCT) in 13, radiochemotherapy and local excision (RCTE) in 7. Mean follow-up time was 6.3 years (range 20 months-11 years). The follow-up program included clinical examination, serum tumor markers evaluation, transrectal ultrasonography (TRUS), anoscopy with either mucosal or by Tru-cut needle multiple biopsies, standard chest X-ray and hepatic-inguinal ultrasonography, endoanal magnetic resonance imaging and in some cases total-body skeletal scintigraphy. A large multicentered randomized and prospective trial is surely lacking and should be undertaken as soon as possible. Our results suggest that an effective local control, rather than a higher survival is the reachable goal at present for anal canal carcinomas. However, further steps should be made to achieve better results. After this experience we propose a more semplified follow-up protocol which consists in performing only rectal examination, endoscopy, Tru-cut needle biopsies and TRUS for local control and inguinal ultrasound and TC to evidence distant metastases.

Aged↗

[Multislice spiral CT angiography in the evaluation of the anatomy of splanchnic vessels: preliminary experience].

PURPOSE: The aim of this study was to optimize the protocol for multislice spiral CT angiography and to assess the ability of the technique to detect the anatomy of splanchnic vessels, using volume rendering as reconstruction algorithm. MATERIAL AND METHODS: The anatomy of splanchnic vessels was studied in 19 patients (11 men, 8 women, age range 38-83 years) undergoing CT of the abdomen and pelvis. All examinations were performed with a multislice spiral CT scanner (Somatom Plus 4 Volume Zoom; Siemens, Erlangen, Germany) using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 8 mm/sec; reconstruction interval, 1 mm; mAs, 120; kVp, 120. Before the study, the patients received 800 ml of water as oral contrast agent to opacify the stomach and small bowel. A nonionic contrast medium (130-140 ml; Xenetix 350, Guerbet, Aulnay-Sous-Bois, France) was infused intravenously at a rate of 3-5 ml/sec. Two scans of the abdomen and pelvis were obtained at 20-25 sec (arterial phase) and 60-65 sec (venous phase) after starting contrast medium injection. Image elaboration was performed using Vitrea 2.2 (Vital Images; Minneapolis, Minn., USA), a software with volume-rendering capabilities. RESULTS: All major arterial (celiac trunk, superior mesenteric artery, and inferior mesenteric artery) and venous (portal vein, superior mesenteric vein, inferior mesenteric vein, and splenic vein) vessels could be evaluated with excellent detail in all patients. Side branches, including small collaterals, could also be easily visualized. Volume rendered images always provided better understanding of the 3D anatomic relationships among splanchnic vessels and surrounding organs. DISCUSSION AND CONCLUSIONS: Multislice spiral CT angiography allows for optimal depiction of the anatomy of splanchnic vessels. It can be anticipated that the clinical applications of this imaging modality in the study of splanchnic vessels will be greatly expanded. However, further studies are necessary to rigorously compare the results of multislice spiral CT angiography with conventional angiography in terms of diagnostic accuracy.

Adult↗

[Optimization of the technique of virtual colonoscopy using a multislice spiral computerized tomography].

PURPOSE: To optimize scanning parameters for virtual colonoscopy utilizing a multislice Helical CT scanner in an in vitro study (using a homemade colonic phantom) and in a preliminary clinical study. MATERIAL AND METHODS: A colonic phantom was built using a plastic tube and 12 plastiline polyps were placed inside. The colonic phantom was studied with a multislice Helical CT scanner. Axial images were obtained with the phantom parallel to the long axis of the moving table (in order to simulate the evaluation of ascending and descending colon): oblique images were acquired with the phantom at 45 degrees relative to the long axis of the moving table (in order to simulate the evaluation of sigmoid colon and colonic flexures). Four different scanning protocols were tested: 1) slice collimation, 5 mm; slice width, 7 mm; table speed, 25 mm; reconstruction index, 5 mm; 2) slice collimation, 2.5 mm; slice width, 3 mm; table speed, 15 mm; reconstruction index, 3 mm; 3) slice collimation, 1 mm; slice width, 1.25 mm; table speed, 5 mm; reconstruction index, 1 mm; 4) slice collimation, 1 mm; slice width, 1.25 mm; table speed, 4 mm; reconstruction index, 1 mm. Quantitative analysis consisted in evaluation of the number of identified polyps and polyp size along the longitudinal axis. Qualitative analysis consisted in the evaluation of image artifacts and quality of 3D reconstructed images (step artifacts and polyp geometry distortion). This preliminary clinical study was performed in 12 patients (7 men and 5 women) who underwent multislice Helical CT colonography. We selected patients with clinical indications for conventional colonoscopy or after unsuccessful conventional colonoscopy. RESULTS: Multislice Helical CT colonography was 100% sensitive in the detection of all polyps and in all scanning protocols. With oblique scans, only a 3-mm polyp was missed during protocol 1 (sensitivity: 92%). Polyp geometry distortion was observed on longitudinal reconstructions, whereas no distortion was seen on axial images. Image quality was graded as optimal for protocols 2, 3, and 4; protocol 1 was graded as good on transverse scans and as poor on oblique scans. In our preliminary clinical study, two colonic carcinomas and three polyps were identified. CONCLUSIONS: At present, the introduction of multislice technology in virtual colonoscopy permits to improve spatial resolution and image definition. The actual clinical advantage, in terms of increased diagnostic accuracy, needs further investigation in larger clinical studies.

Artifacts↗

MRI of the biliary and pancreatic ducts.

Magnetic resonance Cholangiopancreatography (MRCP) is a non-invasive imaging technique able to provide projectional images of the bile ducts. Different sequences, using both breath-hold and non-breath-hold acquisition techniques, have been employed in order to obtain MRCP images. The authors discuss technical aspects, considering both three-dimensional non-breath-hold techniques and two-dimensional breath-hold, multi-slice and thick slab sequences. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85-100%) and, subsequently, its level (accuracy 91-100%) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures, in order to characterize and stage the malignant lesion, is also discussed. Finally, data are presented regarding the indications and the utility of MR-pancreatography in the evaluation of patients with pancreatic duct anomalies and chronic pancreatitis.

Bile Duct Diseases↗

MR cholangiopancreatography in malignant biliary obstruction.

Malignant lesions of the biliary tract are a frequent occurrence, typically presenting with clinical findings of obstructive jaundice. The authors discuss the role of MR cholangiopancreatography (MRCP) as a second level diagnostic technique, which can provide information regarding not only the location, but also the cause of the obstruction. This can be obtained if MRCP is considered as part of a complete study of the upper abdomen, with acquisition of T1- and T2-weighted images. The "all-in-one" approach may provide the identification, characterization, and staging of the lesion, giving the clinician all the information necessary for the planning of adequate treatment. Typical MR features of cholangiocarcinoma are provided, as well as conventional MR and MRCP findings in pancreatic carcinoma, periampullary carcinoma, and biliary obstruction secondary to hilar lymphadenopathy and metastatic lesions.

Bile Duct Neoplasms↗

MR cholangiography of late biliary complications after liver transplantation.

OBJECTIVE: The aim of our study was to assess the role of MR cholangiography in the diagnosis of late biliary complications after liver transplantation. SUBJECTS AND METHODS: Twenty-three liver transplantation patients (18 men and five women; mean age, 46 years) underwent MR cholangiography using a nonbreath-hold, fat-suppressed three-dimensional turbo spin-echo sequence (TR/TE, 3000/700; echo train length, 128) optimized on a 0.5-T magnet. Inclusion criteria were liver function tests with abnormal results and hyperbilirubinemia with a clinical pattern not specific for biliary obstruction. All patients were referred by clinicians for contrast-enhanced cholangiography. Diagnostic confirmation was obtained with percutaneous transhepatic cholangiography (n = 4), endoscopic retrograde cholangiography (n = 8), T-tube cholangiography (n = 1), or clinical follow-up (n = 10). RESULTS: In 11 patients, no abnormalities of the biliary tract were revealed by MR cholangiography. In 11 patients, twelve strictures were diagnosed (nine anastomotic, two nonanastomotic-intrahepatic, and one nonanastomotic-extrahepatic, with association between anastomotic and nonanastomotic strictures in two cases). In one other patient, kinking of the common bile duct at the level of the anastomosis was observed. In all cases, MR cholangiography correctly showed the site of the stricture and the dilatation of bile ducts above, with excellent correlation with contrast-enhanced cholangiographic findings. Strictures were correctly graded in eight of 10 patients and were overestimated in two. Other findings included a 1-cm stone detected proximal to the obstructed common bile duct in one patient and multiple intrahepatic stones in another patient. CONCLUSION: MR cholangiography can show biliary obstruction and provide important information for planning therapeutic procedures.

Adult↗

Localization of pancreatic insulinomas with MR imaging at 0.5 T.

OBJECTIVE: To determine the role of MR imaging in the localization of pancreatic insulinomas in patients with clinical and laboratory diagnosis of insulin-producing tumor. MATERIAL AND METHODS: Thirty-one patients presenting with signs and symptoms of pancreatic insulinomas were prospectively included in our study. Twenty-six patients underwent surgery, and pathologic specimens were examined: 5 patients, in whom the initial diagnosis of insulinoma was excluded, were also studied and then followed up. All patients were studied with a high gradient power 0.5 T magnet. Images were evaluated by 2 radiologists blinded to previous investigations, tests and results. RESULTS: MR imaging correctly localized 24 of the 26 insulinomas (2 were false-negative and 1 false-positive) and was correctly negative in the 5 control patients. The interobserver agreement had a kappa value of 0.89. CONCLUSION: MR imaging was accurate in localizing pancreatic insulinomas and as a consequence, patients in our institution are now submitted to surgery directly after the MR examination. Invasive methods are considered only in cases in which, despite clear biochemical results, MR imaging has not demonstrated a pancreatic focal lesion.

Adolescent↗

MR pyelography and conventional MR imaging in urinary tract obstruction.

PURPOSE: To evaluate the possible role of MR imaging in the assessment of patients with urinary tract obstruction by combining conventional MR imaging and MR pyelography (MRP). MATERIAL AND METHODS: Forty-three patients with dilated upper urinary tract were studied with a high gradient strength 0.5 T magnet. Respiratory compensated T1-weighted, SE and T2-weighted TSE sequences were acquired in all patients. MRP images were obtained by using a respiratory compensated 3D T2-weighted TSE sequence. MRP images were reconstructed with a MIP algorithm. In all cases, urography and/or ascending pyelography were also performed. Images were independently evaluated by two radiologists. RESULTS: The dilated tract ureter and the level of the obstruction could be correctly demonstrated in all cases. The cause of the obstruction was correctly demonstrated by examiner 1 in 90% and by examiner 2 in 88%. The interobserver agreement was high with a kappa-value of 0.96. CONCLUSION: In cases of obstructive hydroureteronephrosis MR imaging, combining MRP and conventional sequences, can be proposed as an accurate technique in the assessment of level and cause of obstruction.

Aged↗

[Magnetic resonance imaging and magnetic resonance cholangiopancreatography in evaluation of chronic pancreatitis. Part I: techniques and methods].

Until recently, MR examinations of the pancreas were limited by motion artifacts, vascular pulsatility and poor spatial resolution. Today, new techniques have been developed, which allow to overcome these problems and provide additional information such as selective images of biliary and pancreatic ducts and vascular structures. MR examinations of the pancreas need to include either breath-hold or nonbreath-hold morphological T1- and T2-weighted images; a contrast agent is required when the study is performed with fast imaging which allow the acquisition of dynamic images in arterial and portal venous phases. Recently, a new liver-specific contrast agent (Mn-DPDP) has been demonstrated to provide selective pancreatic enhancement. As a complement to baseline sequences, MR cholangiopancreatography images can be acquired, possibly integrated by functional examination after secretin administration. Finally, contrast-enhanced MR angiography opens new perspectives for vascular studies, particularly for the locoregional staging of pancreatic cancer.

Cholangiography↗

Pancreatic adenocarcinoma: combination of MR imaging, MR angiography and MR cholangiopancreatography for the diagnosis and assessment of resectability.

The purpose of this study was to determine the possibility of integrating MR cholangiopancreatography (MRCP) and MR angiography (MRA) to conventional MR images in the diagnosis and assessment of resectability of pancreatic adenocarcinoma. Twenty-three patients with pancreatic adenocarcinoma were prospectively examined with MR. Conventional MR images were acquired in all patients. Three-dimensional MRCP and MRA images were acquired in all patients with suspected biliary and vascular involvement. Acquisition time was less than 45 min in all cases. Images were independently evaluated by two radiologists, with final reading decided by consensus among readers. Diagnosis was confirmed with surgery in 16 patients and with percutaneous biopsy in 7. Concordance among readers was high with a kappa value of 0.83. Pancreatic adenocarcinoma was observed in all patients. Correct assessment of unresectability due to vascular involvement was found in 22 of 23 patients. Biliary obstruction was evident in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. Technical advances permit extensive use of MRI in the evaluation of abdominal pathologies. The combination of MR imaging, MRCP, and MRA can provide sufficient information for the diagnosis and assessment of resectability of pancreatic adenocarcinoma, which otherwise would require three different exams.

Adenocarcinoma↗

MR cholangiography: techniques and clinical applications.

Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85-100 %) and, subsequently, its level (accuracy 91-100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis.

Biliary Tract↗

[Virtual endoscopy with a volumetric reconstruction technic: the technical aspects].

OBJECTIVE: We analyze the peculiar technical features of virtual endoscopy obtained with volume rendering. MATERIAL AND METHODS: Our preliminary experience is based on virtual endoscopy images from volumetric data acquired with spiral CT (Siemens, Somatom Plus 4) using acquisition protocols standardized for different anatomic areas. Images are reformatted at the CT console, to obtain 1 mm thick contiguous slices, and transferred in DICOM format to an O2 workstation (Silicon Graphics, Mountain View CA, USA) with processor speed of 180 Mhz, 256 Mbyte RAM memory and 4.1 Gbyte hard disk. The software is Vitrea 1.0 (Vital Images, Fairfield, Iowa), running on a Unix platform. Image output is obtained through the Ethernet network to a Macintosh computer and a thermic printer (Kodak 8600 XLS). RESULTS: Diagnostic quality images were obtained in all the cases. Fly-through in the airways allowed correct evaluation of the main bronchi and of the origin of segmentary bronchi. In the vascular district, both carotid strictures and abdominal aortic aneurysms were depicted, with the same accuracy as with conventional reconstruction techniques. In the colon studies, polypoid lesions were correctly depicted in all the cases, with good correlation with endoscopic and double-contrast barium enema findings. In a case of lipoma of the ascending colon, virtual endoscopy allowed to study the colon both cranially and caudally to the lesion. The simultaneous evaluation of axial CT images permitted to characterize the lesion correctly on the basis of its density values. DISCUSSION: The peculiar feature of volume rendering is the use of the whole information inside the imaging volume to reconstruct three-dimensional images; no threshold values are used and no data are lost as opposite to conventional image reconstruction techniques. The different anatomic structures are visualized modifying the reciprocal opacities, showing the structures of no interest as translucent. The modulation of different opacities is obtained modifying the shape of the opacity curve, either using pre-set curves or in a completely independent way. Other technical features of volume rendering are the perspective evaluation of the objects, color and lighting. In conclusion, volume rendering is a promising technique to elaborate three-dimensional images, offering very realistic endoscopic views. At present, the main limitation is represented by the need of powerful and high-cost workstations.

Aged↗

Hydro-CT in patients with gastric cancer: preoperative radiologic staging.

A total of 35 patients (age range 35-78 years) with gastric tumors on the lesser curve, or in the antro-pyloric region, underwent angio-CT in the prone position after filling the stomach with 500 ml of water and intravenous administration of glucagon. The films were reviewed by three radiologists independently, staging each tumor according to the TNM classification preoperatively. The overall accuracy of tumor staging ranged between 66-77 %, overstaging between 17-25 %, and understaging between 3-8.5 %. The diagnostic sensitivity, specificity, and accuracy for serosal invasion ranged between 90 and 100, 76 and 84, and 80-88 %, respectively, and the overall accuracy for N staging was 46, 48, and 51 % for the three observers. If, however, N1 and N2 tumors were considered as a single group, N-stage accuracy increased, ranging between 63 and 77 %. The "K test" for analyzing the interobserver agreement was 60 %, i. e., the diagnostic results are reproducible. Water filling of the stomach optimizes visualization of the gastric wall on contrast-enhanced CT. The prone position and drug-induced hypotony allows for good distension without any disturbing artifact reduction obscuring the lower gastric body.

Adult↗