PubMed Health⌕ Search

Biomedical subjects

A M Calafiore

Publications and source records attributed to A M Calafiore.

120 records · Page 7Linked to original sources

Off-pump myocardial revascularization using arterial conduits without cardiopulmonary bypass.

OBJECTIVE: The feasibility of myocardial revascularization via a median sternotomy with arterial conduits, without and with cardiopulmonary bypass (CPB), was evaluated. MATERIAL AND RESULTS: From May 21, 1997, to November 30, 1999, 721 patients had myocardial revascularization without CPB via median sternotomy using at least two arterial conduits. The procedure was performed without CPB in 322 patients (Group A); the remaining 399 patients (Group B) underwent the same operation with the aid of CPB. Group A patients were older, with a higher ejection fraction and less redo than Group B. There was no early death in Group A versus nine (2.3%) patients in Group B (p < 0.02). Incidence of cerebrovascular accident (CVA) and acute myocardial infarction (AMI) were similar in both groups. Early major events incidences were 1.2% versus 8.0% (p < 0.001) in Groups A and B, respectively. Postoperative angiographic controls showed a cumulative patency rate of 98.4% and a perfect patency rate of 96.7%. After 30 months, Groups A and B showed an actuarial survival of 98.1 +/- 0.7 and 96.5 +/- 2.8 (p = ns) and an event-free survival of 96.6 +/- 1.0 and 96.5 +/- 2.8 (p = ns), respectively. CONCLUSION: Myocardial revascularization without CPB using arterial conduits can be accomplished with the same quality of results obtained with the use of CPB.

Actuarial Analysis↗

Reoperative coronary surgery with and without cardiopulmonary bypass.

BACKGROUND: Reoperative coronary surgery without cardiopulmonary bypass (CPB) was analyzed to evaluate the technical profile of the patients studied and the benefit from this technique. MATERIAL AND METHODS: From November 21, 1994 to May 20, 1999, 166 patients had reoperative coronary surgery, 112 patients (Group A) with and 54 patients (Group B) without CPB. Median sternotomy was used in all the patients in Group A and in 13 patients in Group B. The remaining had a LAST (37 patients) or a posterolateral thoracotomy (4 patients). RESULTS: Anastomoses per patient were 2.4 +/- 0.8 in Group A and 1.1 +/- 0.4 in Group B (p < 0.001). When a single graft was needed, CPB was not used in 82.8% of the cases. However, when more than one graft was required, CPB was not used in only 5.6% of the cases. When a single territory had to be grafted, CPB was not used in 76.6% of the patients. If two territories were grafted, only 6.8% of the patients were in Group B, whereas no patient who needed a graft in all the three territories was in Group B. Overall mortality was 3.6% cerebrovascular accident (CVA) and acute myocardial infarction (AMI) incidence were 0.6% and 1.8%, respectively, and were similar in both groups. Incidence of early major events (overall 8.4%) was not different between groups. CONCLUSIONS: The primary endpoints (mortality, CVA rate, and AMI) were similar in both groups, but patients in Group B were less complicated. However, patients in the two groups were not the same, as the technical profile was quite different. As our results were similar to those obtained in the first operation, we think that consideration of different surgical possibilities, depending on territory to be grafted, will improve the results of redo coronary surgery, making them similar to those obtained in the first operation.

Cardiopulmonary Bypass↗

[Echocardiographic study of the Björk-Shiley disc prosthesis (author's transl)].

The echocardiography of 25 patients with Björk-Shiley disc prosthesis (16 aortic, 7 mitralic, 1 both mitralic and aortic and 1 both mitralic and tricuspidal) was studied. Mitralic prosthesis were placed with the shortest disc segment looking forward; aortic prosthesis faced the shortest disk segment looking towards the coronaric sinus. The echo's morphology is related to the multiple relationships among position and direction of the prosthesis and the probe. In the aortic echocardiogram, it is possible to recognize echoes from the ring dissociated by anterior and posterior aortic walls. Between them echoes corresponding to the open disc appear, making a quadrangular figure. The values of the internal diameter of the ring obtained were very similar to the real value (difference 0-1 mm). Mitralic echocardiogram is characterized by the valvular disc movement tracing the typical quadrangular pattern, which is due to its opening and closure. Echoes of the supporting apparatus can be recorded directing the probe toward the heart base. In aortic and mitralic prosthesis, disc movements can be estimated. Opening and closure speed rate and their correlation vary on a large scale, both within different patients and in the same patient. Maximum disc excursion appears to be a more homogeneous and constant data in long-term controls and can be used to estimate valvular functionality: in aortic prosthesis valve the obtained value (mean = 17.46 +/- 0.53 "ES") is similar to the real diameter of the disc, in mitral prosthesis valve the value obtained (mean = 17.50 +/- 0.74 "ES") is shorter than the real value.

Adolescent↗

[Myocardial revascularization with the internal mammary artery. The indications, technics and results].

This report reviews 218 patients who underwent internal mammary artery (IMA) grafting alone or with vein graft between 1986-1989. Our experience with IMA started with a single attached graft for proximal left anterior descending lesions in young patients affected from stable angina. After that our indications became more extensive. One IMA was utilized in 209 cases, both two IMAs in the remaining 9. Sequential IMA graft was performed in 16 patients and free IMA graft in 8. There were 242 IMA anastomosis and 295 associated vein by-passes. The overall operative mortality was 2.3%. Perioperative complications include myocardial infarction in 3 (1.4%), reoperation for bleeding in 4 (1.8%) and sternal wound complication in 4 (1.8%). These results are comparable to those of patients having only saphenous vein by-pass during the same period. At the follow-up actuarial survival rate at 42 months was 94 1.8% and 90% of these patients were completely asymptomatic. We include that IMA grafting shows low operative risk and provide excellent short term results. Our findings and the high long term patency rate of this conduit encourage us to extend the indication to IMA and to perform those surgical techniques that make possible multiple mammary coronary anastomosis.

Angina Pectoris↗

Valve replacement with the tilting disc Sorin prosthesis in patients with narrow aortic annulus.

The Authors summarize their 5-year experience of the clinical use of the Sorin tilting disc prosthesis in 40 patients (group A) with narrow aortic annulus, compared with a control group (group B: 116 patients) where a larger Sorin prosthesis was implanted. Follow-up lasted from 1 to 60 months, with a mean of 25.6 +/- 12.3 in group A and 20.4 +/- 11.9 in group B. Early and late mortality were low: 1/40 and 2/39 (2.5 and 5.1%) in group A and 4/116 and 9/112 (3.4 and 8.0%) in group B (p = NS): only two deaths, one in each group, were prosthesis-related. Actuarial survival was comparable: 91.2% (CL: 96.3-86.1%) in group A and 78.0% (CL: 87.6-68.4%) in group B, as were probability of being event-free and alive, non-reoperated and with few or no symptoms [group A: 61.7% (CL: 72.4-51.0%) and 77.4% (CL: 85.9-68.9%) respectively; group B: 78.8% (CL: 83.4-74.2%) and 61.1% (CL: 85.9-68.9%) respectively]. The Authors conclude that the Sorin tilting disc prosthesis is a reliable valve substitute in the narrow aortic annulus; they recommend that enlargement procedures should be confined only to patients with annulus size less than 19 mm.

Actuarial Analysis↗

A comparative clinical assessment of a hollow-fibre membrane oxygenator (Capiox II) and a bubble oxygenator (Harvey 1500).

Personal experience is reported on the use of a membrane oxygenator, the Capiox II, which is clinically compared with a bubble oxygenator for medium-term perfusion. The characteristics considered were the efficiency of the heat exchanger, the oxygenating capacity, traumatic effects on the blood and the direct effect on the renal and cardiopulmonary systems. The Capiox II demonstrated a better oxygenating capacity, less platelet damage, a smaller variation in the free plasma haemoglobin, a significant difference in postoperative bleeding and blood transfusion requirements, but showed no variation in renal and cardiopulmonary function. The authors suggest that the Capiox II is to be preferred for extra-corporeal circulation of medium duration, for which it combines the advantages of both bubble and membrane oxygenators, while being less complex and costly than previously marketed membrane devices.

Blood Gas Analysis↗