Clinical experience and expectation with protons and heavy ions.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A M Koehler.
Explore the source record for details and available documents.
The feasibility of a new method for in vivo regional bone calcium measurement has been studied in phantoms using the 160 MeV Harvard cyclotron, Advantages include the capability of measuring bone calcium directly directly in a well defined anatomical region (such as one or several vertebrae) and restriction of the dose to the immediate region of interest. Proton activation of 40Ca (97% natural abundance) produces radionuclide 38K. Its 2-17 MeV gamma ray (T 1/2 = 7-71 min) is detected by a NaI counter. Separation of this activity from room background and interfering nuclides, 14O and 34Clm, proceeds by decay curve analysis. Phantom studies showed the dependence of 38K activity to be highly linear with calcium content (r= 0-998). Non-linearities with dose did not appear below the 20 rad level. The precision of measurements on a phantom with two calf vertebrae exposed to 2-4 rad was 3% and was mostly limited by counting statistics. System reproducibility on phantoms given a high dose proved better than 0-5%.
An attempt has been made to see whether energetic protons (158 MeV) could be used instead of X-rays in computerized axial tomography to detect density differences of the order of those at which commercial X-ray tomographs cease to be useful. A circularly symmetrical phantom consisting of Lucite and sugar solutions was used, and density differences of 0-5% were reconstructed with reasonable accuracy from data obtained with very simple equipment. Discontinuities in either density or chemical composition, or both, seem to cause artifacts in the reconstruction. These may be related to the West-Sherwood effect.
Explore the source record for details and available documents.
Three patients have been treated with 160-MeV protons combined with high-energy photons to examine the advantages and difficulties associated with the clinical implementation of a program of large-field, fractionated-dose, protonradiation therapy. We havefound it necessary to 1) obtain an accurate three-dimensional determination of the treatment volume including the density of all tissues in the beam path; 2) construct an adequate bolus to compensate for tissue heterogeneities; 3) use much more precise and accurate immobilization and patient positioning devices than used in photon irradiation; 4) treat with both protons and photons so as to keep the skin dose within an acceptable level. IN TISSUES WITHOUT SIGNIFICANT INHOMOGENETIES DUE TO BONE AND AIR SPACES WE HAVE DELIVEREDA WELL-DEFINED DOSE TO INVOLVED TISSUES WHILE SPARING DISTAL SENSITIVE STRUCTURES. However, in those regions where there is much "fine structure" of tissue density, it has been difficult to compensate satisfactorily for the inhomogeneties.
Silicone sponges were sutured to the sclera of owl monkeys to create an indentation which would simulate a tumor of the posterior segment of the eye. A tantalum clip inserted in the silicone sponge served as a marker for radiographic localization of the simulated tumors. The acute lesions obtained on the retina and choroid after moderately high doses of proton irradiation suggest that this method of aiming the proton beam will be adquate for human clinical trials.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Monoenergetic protons are highly sensitive to density variations and are capable of giving radiographs of very high contrast. As an initial step in exploring their diagnostic potential, protons with energies of 160 million electron volts are used in "contact radiography" on tumor-bearing human brain specimens. The proton radiographs are compared with x-radiographs taken under identical specimen conditions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.