PubMed Health⌕ Search

Biomedical subjects

A M Koehler

Publications and source records attributed to A M Koehler.

40 records · Page 3Linked to original sources

Flattening of proton dose distributions for large-field radiotherapy.

Methods for obtaining flattened charged-particle dose distributions over large areas are described. The system being used at Harvard for proton radiotherapy is discussed in detail. It is an extension of usual multiple-scattering techniques to include blocking out some of the central peak, followed by rescattering to fill in the profile, resulting in flat distributions up to 30 cm in diameter. The unusually long source-to-skin distance (4.6-m SSD) plus the small lateral spread (2 mm rms) from multiple scattering in the patient results in little divergence of the beam throughout the treatment volume.

Protons↗

Proton penetration and control in nonhomogeneous phantoms.

Accurate bolus is needed for extension of Bragg-peak therapy. Proton beam-stopping profiles in a lucite-styrofoam-tissue phantom and in a Rando phantom were recorded photographically. Air volumes caused the largest distortions. Lucite bolus was cut to achieve desired beam-stopping profiles. Verification of bolus effect in situ will be important to control beam penetration within 5 mm.

Models, Structural↗

Proton beam penumbra: effects of separation between patient and beam modifying devices.

The sharp lateral penumbra of a proton beam is often used to spare sensitive normal structures in treating clinical sites in which the target volume abuts, or even wraps around, these structures. Using Monte Carlo calculations and measurements, the factors which influence the penumbra of the proton beam at the Harvard Cyclotron Laboratory were investigated, with particular emphasis on the effects of separation between the patient and any beam modifying devices. Penumbra broadening, characterized by the distance over which the dose rises from 20% to 80% of the central dose, increases with greater amounts of scatterer introduced into the beam line. The broadening due to separation of the beam modifying devices and the patient is essentially linear with increasing air gap; the rate of increase depends on the details of these devices and on the depth of interest in the patient. For a particular portal, most of the parameters which affect the penumbra width are fixed by the patient's anatomy and the target volume. Only the thickness of the compensating bolus around the aperture edge and any air gap between the patient and the beam modifying devices can vary. Families of curves relating combinations of bolus thickness and air gap that maintain a constant penumbra width have been developed for guidelines during patient setup.

Biophysical Phenomena↗

Proton beam irradiation for treatment of experimental human retinoblastoma.

Proton beam irradiation was used to treat human retinoblastoma (Y-79 cell line) grown subcutaneously in the athymic "nude" mouse. Thirty-four tumors were included in the experimental groups, of which twenty-three were irradiated and eleven served as controls. Tumors were irradiated with protons produced at the 160 megavolts Harvard cyclotron. The dose delivered to the tumor ranged from 7.5 to 27.5 proton gray in a single treatment, and 25.0 proton gray delivered in two fractions separated by 24 hours. Reduction of tumor growth was significantly greater than controls (p less than 0.001) with treatment doses greater than or equal to 17.5 proton gray. Histologic examination revealed a marked decrease of mitotic activity in all specimens examined 48 hours after treatment at these higher doses. Total regression without evidence of remaining malignant cells was noted in three tumors treated at 17.5 proton gray or above. Our results indicate that human retinoblastoma in a murine host, with a tumor mass similar to that seen in a clinical setting, is sensitive to radiation by high energy protons.

Animals↗