Discretizing large traceable vessels and using DE-MRI perfusion maps yields numerical temperature contours that match the MR noninvasive measurements.

The success of hyperthermia treatments is dependent on thermal dose distribution. However, the three-dimensional temperature distribution remains largely unknown. Without this knowledge, the relationship between thermal dose and outcome is noisy, and therapy cannot be optimized. Accurate computations of thermal distribution can contribute to an optimized therapy. The hyperthermia modeling group in the Department of Radiotherapy, University Medical Center Utrecht devised a Discrete Vasculature [Kotte et al., Phys. Med. Biol. 41, 865-884 (1996)] model that accounts for the presence of vessel trees in the computational domain. The vessel tree geometry is tracked using magnetic resonance (MR) angiograms to a minimum diameter between 0.6 and 1 mm. However, smaller vessels (0.2-0.6 mm) are known to account for significant heat transfer. The hyperthermia group at Duke University Medical Center has proposed using perfusion maps derived from dynamic-enhanced magnetic resonance imaging to account for the tissue perfusion heterogeneity [Craciunescu et al., Int. J. Hyperthermia 17, 221-239 (2001)]. In addition, techniques for noninvasive temperature measurements have been devised to measure temperatures in vivo [Samulski et al., Int. J. Hypertherminal, 819-829 (1992)]. In this work, a patient with high-grade sarcoma has been retrospectively modeled to determine the temperature distribution achieved during a hyperthermia treatment. Available for this model were MR depicted geometry, angiograms, perfusion maps, as necessary for accurate thermal modeling, as well as MR thermometry data for validation purposes. The vasculature assembly through modifiable potential program [Van Leeuwen et al., IEEE Trans. Biomed. Eng. 45, 596-604 (1998)] was used in order to incorporate the traceable large vessels. Temperature simulations were made using different approaches to describe perfusion. The simulated cases were the bioheat equation with constant perfusion rates per tissue type, perfusion maps alone, tracked vessel tree and perfusion maps, and generated vessel tree. The results were compared with MR thermometry data for a single patient data set, concluding that a combination between large traceable vessels and perfusion map yields the best results for this particular patient. The technique has to be repeated on several patients, first with the same type of malignancy, and after that, on patients having malignancies at other different sites.

Algorithms↗

How to apply a discrete vessel model in thermal simulations when only incomplete vessel data are available.

For accurate predictions of the temperature distribution during hyperthermia treatment a thermal model should incorporate the individual impact of discrete vessels. In clinical practice not all vessels can be reconstructed individually. This paper investigates five possible strategies to model the thermal impact of these missing vessels. A tissue volume with a detailed, realistic, counter-current discrete vasculature is heated and the steady-state temperature distribution is calculated using our Discrete Vasculature (DIVA) thermal model. To mimic incomplete discrete vasculatures the full tree is gradually stripped, that is, the number of discretely described vessels is reduced in four steps until no discrete vessels are left. At each strip level the steady state temperature distribution is calculated for five different strategies to model the missing vessels. The strategies all use a local or global heat sink model in addition to the discrete vasculature. The resulting temperature distributions are compared with the full tree simulation. With increasing strip level the correspondence with the full tree simulation deteriorated for all strategies. An optimal strategy was found to model the missing vessels depending on the available angiographic data. It was also found that simulations with a decreased number of discrete vessels, or no vessels at all, yield temperatures which are too high. Theoretically this can be compensated by increasing the thermal conductivity; finding the optimal value is done empirically.

Blood↗

Temperature simulations in tissue with a realistic computer generated vessel network.

The practical use of a discrete vessel thermal model for hyperthermia treatment planning requires a number of choices with respect to the unknown part of the patient's vasculature. This work presents a study of the thermal effects of blood flow in a simple tissue geometry with a detailed artificial vessel network. The simulations presented here demonstrate that an incomplete discrete description of the detailed network results in a better prediction of the temperature distribution than is obtained using the conventional bio-heatsink equation. Therefore, efforts to obtain information on the positions of the large vessels in an individual hyperthermia patient will be rewarded with a more accurate prediction of the temperature distribution.

Arteries↗

Modelling the thermal impact of a discrete vessel tree.

Based on a modelling technique to calculate the thermal influence of a single vessel segment, a combination of segments representing a vessel tree is presented. At segment junctions the blood temperature is passed with a correction for a single vessel artefact. Blood leaving the modelled arterial vessel network at a junction or at the end of a terminal branch need not be equilibrated with the local surrounding tissue temperature. The thermal effect of this equilibration process can be taken into account using the 'sink set'. Blood entering a venous vessel tree is given an inflow temperature based on the tissue temperatures in the 'sample set'. With these sets we model the thermal impact of the vasculature too small to be taken into account discretely. The formation of the sink/sample sets is subject of current research; to show the capabilities of the presented method we present a minimal simulation collection with cube-shaped sets in combination with limited vasculature. The results of using the entire simulation volume as sink and sample sets for all the terminal branches matches the reference temperature profile best.

Arteries↗

Calculation of change in brain temperatures due to exposure to a mobile phone.

In this study we evaluated for a realistic head model the 3D temperature rise induced by a mobile phone. This was done numerically with the consecutive use of an FDTD model to predict the absorbed electromagnetic power distribution, and a thermal model describing bioheat transfer both by conduction and by blood flow. We calculated a maximum rise in brain temperature of 0.11 degrees C for an antenna with an average emitted power of 0.25 W, the maximum value in common mobile phones, and indefinite exposure. Maximum temperature rise is at the skin. The power distributions were characterized by a maximum averaged SAR over an arbitrarily shaped 10 g volume of approximately 1.6 W kg(-1). Although these power distributions are not in compliance with all proposed safety standards, temperature rises are far too small to have lasting effects. We verified our simulations by measuring the skin temperature rise experimentally. Our simulation method can be instrumental in further development of safety standards.

Body Temperature↗

Modelling tissue heating with ferromagnetic seeds.

Interstitial hyperthermia using ferromagnetic seeds demands accurate treatment planning: the seed characteristics and implant geometry must be determined prior to the treatment. A new, finite difference based, seed modelling method is presented. The seed, together with all its surrounding (non-tissue) layers is described as one unit, independent of the tissue grid. The calculation of the seed-tissue interaction is based on the local seed temperature and several tissue temperature samples in the direct vicinity. All the layers between the seed and the surrounding tissue are taken into account in this interaction calculation. The presented implementation describes the analytical solution of the modelled steady-state configurations very accurately. The separation between tissue and seed allows easy assessment of the resulting seed temperature profile which is essential to the optimization of the seed characteristics in treatment planning. The thermal effect due to blood flow in the modelled tissue volume surrounding the seed can be accounted for by inclusion of a heat sink term as well as by inclusion of realistic discrete vasculature.

Algorithms↗

Dose uniformity of ferromagnetic seed implants in tissue with discrete vasculature: a numerical study on the impact of seed characteristics and implantation techniques.

The results from simulations with a new three-dimensional treatment planning system for interstitial hyperthermia with ferromagnetic seeds are presented in this study. The thermal model incorporates discrete vessel structures as well as a heat sink and enhanced thermal conductivity. Both the discrete vessels and the ferroseeds are described parametrically in separate calculation spaces. This parametric description has the advantage of an arbitrary orientation of the structures within the tissue grid, easy manipulation of the structures and independence from the resolution of the tissue voxels (tissue calculation space). The power absorption of the self-regulating seeds is according to empirical data. The thermal effects of an unlimited number of thin layers surrounding the seed (coatings, catheters) can be modelled. The initial calculations have been performed for an array of 12 identical ferromagnetic seeds in a tissue volume with a computer generated artificial vessel network spanning four vessel generations in both the arterial and venous tree. The heterogeneously distributed large isolated vessels impair the temperature distribution significantly, indicating the limited accuracy of continuum models. Simulations with different types of ferromagnetic seeds have confirmed that the efforts of previous studies to optimize the self-regulating temperature control and the implantation techniques of the ferroseeds will improve the homogeneity of the temperature distribution in the target volume. Multifilament seeds implanted in brachytherapy needles and tubular seeds appear to be the most favourable configurations. The division of long seeds into shorter segments with the appropriate Curie temperature will further improve the homogeneity of the temperature distribution without increasing the average temperature in the volume of interest. Given the proper thermal tissue data, the model presented in this study will prove to be a useful tool in making choices for the implant geometry, seed spacing and Curie temperature.

Biophysical Phenomena↗

A flexible algorithm for construction of 3-D vessel networks for use in thermal modeling.

A new algorithm for the construction of artificial blood vessel networks is presented. The algorithm produces three-dimensional (3-D) geometrical representations of both arterial and venous networks. The key ingredient of the algorithm is a 3-D potential function defined in the tissue volume. This potential function controls the paths by which points are connected to existing vessels, thereby producing new vessel segments. The potential function has no physiological interpretation, but, by adjustment of parameters governing the potential, it is possible to produce networks that have physiologically meaningful geometrical properties. If desired, the veins can be generated counter current to the arteries. Furthermore, the potential function allows fashioning of the networks to the presence of bone or air cavities. The resulting networks can be used for thermal simulations of hyperthermia treatment.

Algorithms↗

Accuracy of geometrical modelling of heat transfer from tissue to blood vessels.

We have developed a thermal model in which blood vessels are described as geometrical objects, 3D curves with associated diameters. Here the behaviour of the model is examined for low resolutions compared with the vessel diameter and for strongly curved vessels. The tests include a single straight vessel and vessels describing the path of a helix embedded in square tissue blocks. The tests show the excellent behaviour of our discrete vessel implementation.

Blood Vessels↗

Tests of the geometrical description of blood vessels in a thermal model using counter-current geometries.

We have developed a thermal model, for use in hyperthermia treatment planning, in which blood vessels are described as geometrical objects; 3D curves with associated diameters. For the calculation of the heat exchange with the tissue an analytic result is used. To arrive at this result some assumptions were made. One of these assumptions is a cylindrically symmetric temperature distribution. In this paper the behaviour of the model is examined for counter-current vessel geometries for which this assumption is not valid. Counter-current vessel pairs intersecting a circular tissue slice are tested. For these 2D geometries vessel spacing, tissue radius and resolution are varied, as well as the position of the vessel pair with respect to the discretized tissue grid. The simulation results are evaluated by comparison of the different heat flow rates with analytical predictions. The tests show that for a fixed vessel configuration the accuracy is not a simple decreasing function of the voxel dimensions, but is also sensitive to the position of the configuration with respect to the discretized tissue grid.

Blood Vessels↗

Development of a regional hyperthermia treatment planning system.

A flexible and fast regional hyperthermia treatment planning system for the Coaxial TEM System has been devised and is presented. Using Hounsfield Unit based thresholding and manually outlining of the tumour, a 40 cm CT data set (slice thickness 5 mm) is segmented and down scaled to a resolution of 1 cm, requiring only 30 min. The SAR model is based on the finite-difference time-domain (FDTD) method. The number of time steps to achieve numerical stability has been determined and was found to be 7000. Various optimizations of the SAR model have been applied, resulting in a relatively short computation time of 3.7 h (memory requirements 121 MB) on a Pentium III, 450 MHz standard personal computer, running GNU/Linux. The model has been validated using absolute value(Ez) measurements in a standard phantom inserted in the Coaxial TEM Applicator under different conditions and a good agreement was found. Hyperthermia treatment planning in combination with the homemade visualization tools have provided much insight in the regional hyperthermia treatment with the Coaxial TEM Applicator.

Electromagnetic Fields↗

The influence of vasculature on temperature distributions in MECS interstitial hyperthermia: importance of longitudinal control.

The quality of temperature distributions that can be generated with the Multi Electrode Current Source (MECS) interstitial hyperthermia (IHT) system, which allows 3D control of the temperature distribution, has been investigated. For the investigations, computer models of idealised anatomies containing discrete vessels, were used. A 7-catheter hexagonal implant geometry with a nearest neighbour distance of 15 mm was used. In each interstitial catheter with a diameter of 2.1 mm a number of 1 up to 4 electrodes were placed along an 'active section' with a length of 50 mm. The electrode segments had lengths of 50, 20, 12 and 9 mm respectively. Both single vessel and vessel network situations were analysed. This study shows that even in situations with discrete vasculature and perfusion heterogeneity it remains possible to obtain satisfactory temperature distributions with the MECS IHT system. Due to its 3D spatial control the temperature homogeneity in the implant can be made quite satisfactory.

Blood Vessels↗