PubMed Health⌕ Search

Biomedical subjects

A Ruggeri

Publications and source records attributed to A Ruggeri.

At least 19 recordsLinked to original sources

Destination of titanium particles detached from titanium plasma sprayed implants.

Small titanium particles may detach from titanium plasma sprayed (TPS) implants during implant insertion, when no preliminary tapping is used, probably for the frictional force between titanium coating and host bone. Aim of this study was to investigate the destination of these titanium particles observed in the peri-implant environment. Twenty-four TPS screws were implanted in tibiae of two sheep. Fourteen and 90 days after implantation the implants with the surrounding bone were removed and processed to be analyzed by light microscope and scanning electron microscope (secondary electron and back-scattered electron probes). Small titanium particles detached from the unloaded TPS implants were observed both in the newly-formed bone matrix and in marrow tissue. Histomorphometric analysis showed that both at 14 and 90 days after implantation the titanium particles appeared more concentrated in marrow tissue than in calcified bone matrix, decreasing by 66.4% over time. In particular, smaller particles (<250 microm(2)) decreased by 81.5%, whereas the larger ones (250-2000 microm(2)) did not show any significant variations over time, suggesting that most of the smaller particles may undergo to ionic dissolution, probably migrating into the peri-implant marrow lacunae. A slight migration of titanium particles from the implant surface towards the more distant peri-implant tissues was also demonstrated over time.

Animals↗

Reduced antigenicity of type I collagen and proteoglycans in sclerotic dentin.

Antigenic alterations to the dentin organic matrix may be detected by an immunohistochemical approach. We hypothesized that alterations in the antigenicity of type I collagen and proteoglycans occur in sclerotic dentin under caries lesions. Transverse sections were prepared from carious teeth in the sclerotic zone and normal hard dentin. A double-immunolabeling technique was performed on these sections, with anti-type I collagen and anti-chondroitin 4/6 sulfate monoclonal primary antibodies. We used gold-conjugated secondary antibodies to visualize the distribution of intact collagen fibrils and proteoglycans by high-resolution SEM. For sclerotic dentin, labeling densities were 19.57 +/- 3.01/microm2 for collagen and 9.84 +/- 2.62/microm2 for proteoglycans. For normal hard dentin, values were 35.20 +/- 2.73/microm2 and 17.03 +/- 1.98/microm2, respectively. Distribution of intact collagen fibrils and proteoglycans in sclerotic dentin was significantly lower than in normal hard dentin. Reductions in antigenicity from the organic matrix of sclerotic dentin under caries lesions raise concern about the potential of intrafibrillar remineralization.

Collagen Type I↗

Electric-current-assisted application of self-etch adhesives to dentin.

The use of electric current during the application of etch-and-rinse adhesive systems has been recently claimed to increase bonding of etch-and-rinse adhesives by enhancing substrate impregnation. The null hypothesis tested in this study was that electrically assisted application has no effect on bond strength of self-etching bonding systems. Three self-etch adhesives (Protect-Bond, Xeno III, and Prompt L-Pop) were applied with the aid of an electric signal-generating device (ElectroBond) and tested vs. controls prepared with the same disposable sponges but without electric current. Specimens bonded under the influence of electric current exhibited increased microtensile bond strength compared with the controls (p<0.05). High-resolution SEM analysis showed that bonding under the influence of electricity reduced interfacial nanoleakage. It is speculated that resin infiltration may be improved by the attraction of polar monomers by an electric current or by modification of the dentin surface charges, resulting in better water substitution or evaporation.

Ammonia↗

Biological fixation of endosseous implants.

Primary implant stability is ensured by a mechanical fixation of implants. However, during implant healing a biological anchorage is necessary to achieve final osseointegration. Aim of this study was to investigate the histological aspects of biological fixation around titanium screws. Forty-eight titanium screws with different surfaces (smooth, plasma sprayed, sand blasted) were inserted in tibiae and femura of sheep and analyzed by light microscope and SEM 1 hour, 14 and 90 days after implantation. One hour after implantation the implant-bone gap was filled with a blood clot and host bone chips arising from burr surgical preparation or friction during implant insertion. Fourteen days after implantation new trabecular bone and enveloped bone chips were observed in the gap: no osteogenesis developed where implant threads were in contact with host bone. Ninety days after surgery all trabecular bone and most of the bone chips were substituted by a mature lamellar bone with few marrow spaces. Our results suggest that the trabecular bone and bone chips represent a three-dimensional network ensuring a biological implant fixation in all different implant surfaces 2 weeks after surgery. Host bone chips could favour the peri-implant osteogenesis. Inter-trabecular and implant-trabecular marrow spaces of both trabecular and lamellar bone may favour the peri-implant bone turnover.

Animals↗

A new system for the automatic estimation of endothelial cell density in donor corneas.

AIMS: The problem of automatic estimation of endothelial cell density from microscopy images in donor corneas was addressed. METHODS: The spatial frequencies contained in digital endothelium images are extracted with a two dimension discrete Fourier transform (DFT) technique. A circular band in the DFT of the images is shown to contain the frequency information related to the cell density. An algorithm for reliably recovering this spatial frequency information and for extracting from it an estimate of endothelial cell density has been developed and implemented in a computer program. An evaluation was performed on a data set containing 100 donor corneas, by comparing automatic values with manual counts performed by three eye bank experts on two images for each cornea. RESULTS: The mean difference of automatic densities v manual ones was 14 cells/mm(2) (0.9%), with a standard deviation of 119 cells/mm(2) (5.1%) and mean absolute difference of 92 cells/mm(2) (3.9%). The ANOVA based overall inter-rater reliability was 0.935. The algorithm was also capable of identifying all non-processable images. Running times were in the order of 1-2 seconds per image. CONCLUSION: A new algorithm was developed for the fully automatic estimation of endothelial cell density. The results of a clinical evaluation on 100 corneas suggest that it is capable of reliably estimating endothelium cell density in donor corneas.

Algorithms↗

Cyclosporin A specifically affects nuclear PLCbeta1 in immunodepressed heart transplant patients with gingival overgrowth.

One of the most commonly observed adverse effects of cyclosporin A (CsA) is the development of gingival overgrowth (GO). Fibroblasts are involved in GO, but the question why only a percentage of patients undergoing CsA treatment shows this side-effect remains unanswered. In a previous study, CsA has been demonstrated to induce over-expression of phospholipase C (PLC) beta(1) in fibroblasts of patients with clinical GO, in cells from both enlarged and clinically healthy gingival sites. In this work, we assessed the expression of PLCbeta isoforms to investigate whether the exaggerated fibroblast response to CsA related to increased PLCbeta(1) expression could also be detected in CsA-treated patients without clinical signs of GO. Our results support the hypothesis of a multi-factorial origin of gingival overgrowth, including specific changes within the gingival tissues orchestrating fibroblastic hyper-responsiveness as a consequence of a long-term in vivo exposure to cyclosporin A.

Adult↗

Automatic estimation of endothelium cell density in donor corneas by means of fourier analysis.

One of the main clinical parameters expressing the health of a cornea is the cell density of its endothelium. This information is particularly important in an eye bank environment, where donor corneas are screened to assess their suitability as a human graft. Endothelium cell density is conventionally estimated by a long, tedious and error-prone manual counting procedure, performed by cornea experts on specimen images observed through an optical microscope. An alternative solution is proposed: a computer program that provides automatic estimation of cell density in donor corneas by analysing the spatial frequencies contained in the image. A circular band in the 2D discrete Fourier transform of the image is shown to contain the relevant information about the cell density. A system for extracting from this spatial frequency information an estimate of the cell density has been developed. A clinical evaluation of the proposed technique was performed on 18 corneas, where the densities provided by the proposed technique were compared with those manually obtained by two experts. The results showed an average percentage difference of 3% (maximum 19%), a value well within the measured inter-expert range of variability. The proposed automatic procedure confirmed its ability to estimate correctly corneal endothelium cell density.

Algorithms↗

Early detachment of titanium particles from various different surfaces of endosseous dental implants.

Titanium (Ti) endosseous dental screws with different surfaces (smooth titanium--STi, titanium plasma-sprayed-TPS, alumina oxide sandblasted and acid-etched--Al-SLA, zirconium oxide sandblasted and acid etched--Zr-SLA) were implanted in femura and tibiae of sheep to investigate the biological evolution of the peri-implant tissues and detachment of Ti debris from the implant surfaces in early healing. Implants were not loaded. Sections of the screws and the peri-implant tissues obtained by sawing and grinding were analysed by light microscopy immediately after implantation (time 0) and after 14 days. All samples showed new bone trabeculae and vascularised medullary spaces in those areas where gaps between the implants and host bone were visible. In contrast, no osteogenesis was induced in the areas where the implants were initially positioned in close contact with the host bone. Chips of the pre-existing bone inducing new peri-implant neo-osteogenesis were surrounded by new bone trabeculae. The threads of some screws appeared to be deformed where the host bone showed fractures. Ti granules of 3-60 microm were detectable only in the peri-implant tissues of TPS implants both immediately after surgery and after 14 days, thus suggesting that this phenomenon may be related to the friction of the TPS coating during surgical insertion.

Animals↗

Interactions of fibroblasts with soldered and laser-welded joints.

Relatively little is known about the biocompatibility of the soldered or laser-welded joints of dental appliances. We investigated the reaction of human gingival fibroblasts cultured in vitro in direct contact with samples of soldered and laser-welded joints from orthodontic lingual arches. Contrast phase light microscopy was used to evaluate cell adhesion, morphology and proliferation after 6 and 24h and after 7 and 16 days. Scanning electron microscopy (SEM) was performed at 16 days. Our in vitro findings provide evidence that laser-welded orthodontic appliances have superior fibroblast biocompatibility.

Adult↗

Detection of optic disc in retinal images by means of a geometrical model of vessel structure.

We present here a new method to identify the position of the optic disc (OD) in retinal fundus images. The method is based on the preliminary detection of the main retinal vessels. All retinal vessels originate from the OD and their path follows a similar directional pattern (parabolic course) in all images. To describe the general direction of retinal vessels at any given position in the image, a geometrical parametric model was proposed, where two of the model parameters are the coordinates of the OD center. Using as experimental data samples of vessel centerline points and corresponding vessel directions, provided by any vessel identification procedure, model parameters were identified by means of a simulated annealing optimization technique. These estimated values provide the coordinates of the center of OD. A Matlab prototype implementing this method was developed. An evaluation of the proposed procedure was performed using the set of 81 images from the STARE project, containing images from both normal and pathological subjects. The OD position was correctly identified in 79 out of 81 images (98%), even in rather difficult pathological situations.

Algorithms↗

Detachment of titanium and fluorohydroxyapatite particles in unloaded endosseous implants.

The shape, surface composition and morphology of orthopaedic and endosseous dental titanium implants are key factors to achieve post-surgical and long-term mechanical stability and enhance implant osteointegration. In this study a comparison was made between 12 titanium screws, plasma-spray-coated with titanium powders (TPS), and 12 screws with an additional coating of fluorohydroxyapatite (FHA-Ti). Screws were implanted in the femoral and tibial diaphyses of two mongrel sheep and removed with peri-implant tissues 12 weeks after surgery. The vibrational spectroscopic, ultrastructural and morphological analyses showed good osteointegration for both types of implants in host cortical bone. The portion of the FHA-Ti implants in contact with the medullary canal showed a wider area of newly formed peri-implant bone than that of the TPS implants. Morphological and EDAX analyses demonstrated the presence of small titanium debris in the bone medullary spaces near the TPS surface, presumably due to the friction between the host bone and the implant during insertion. Few traces of titanium were detected around FHA-Ti implants, even if smaller FHA debris were present. The present findings suggest that the FHA coating may act as a barrier against the detachment of titanium debris stored in the medullary spaces near the implant surface.

Animals↗

Biomechanical and histomorphometric investigations on two morphologically differing titanium surfaces with and without fluorohydroxyapatite coating: an experimental study in sheep tibiae.

The influence of fluorohydroxyapatite (FHA) coating and surface roughness of Ti6Al4V implants on bone response was investigated. Uncoated and FHA-coated screws with lower (LR and LR+FHA; Ra: 5.7+/-0.2 microm) and higher (HR and HR+FHA; Ra: 21.8+/-0.9 microm) surface roughness, were inserted into the diaphyses of 8 sheep tibiae. Twelve weeks after implantation, extraction torque and bone-to-implant contact were evaluated. The smoothest surfaces showed an improved extraction torque and significant differences were observed between LR and HR (-24.6%, p<0.0005), LR and HR+FHA (-30.7%, p<0.0005), LR+FHA and HR (-17.4%, p<0.005), and LR+FHA and HR+FHA (-24.0%, p<0.005). The bone-to-implant contact data paralleled the biomechanical data: the smoother the surface, the greater the bone-to-implant contact. Significant (p<0.0005) decreases in bone-to-implant contact were observed between LR+FHA and HR (-24.2%), and between LR+FHA and HR+FHA (-29.2%). The current findings suggest that LR surfaces significantly improve the osteointegration rate of implanted cortical screws independently of the FHA coating.

Animals↗

A new selective AKT pharmacological inhibitor reduces resistance to chemotherapeutic drugs, TRAIL, all-trans-retinoic acid, and ionizing radiation of human leukemia cells.

It is now well established that the reduced capacity of tumor cells of undergoing cell death through apoptosis plays a key role both in the pathogenesis of cancer and in therapeutic treatment failure. Indeed, tumor cells frequently display multiple alterations in signal transduction pathways leading to either cell survival or apoptosis. In mammals, the pathway based on phosphoinositide 3-kinase (PI3K)/Akt conveys survival signals of extreme importance and its downregulation, by means of pharmacological inhibitors of PI3K, considerably lowers resistance to various types of therapy in solid tumors. We recently described an HL60 leukemia cell clone (HL60AR cells) with a constitutively active PI3K/Akt pathway. These cells were resistant to multiple chemotherapeutic drugs, all-trans-retinoic acid (ATRA), and tumor necrosis factor-related apoptosis-inducing ligand (TRAIL). Treatment with two pharmacological inhibitors of PI3K, wortmannin and Ly294002, restored sensitivity of HL60AR cells to the aforementioned treatments. However, these inhibitors have some drawbacks that may severely limit or impede their clinical use. Here, we have tested whether or not a new selective Akt inhibitor, 1L-6-hydroxymethyl-chiro-inositol 2(R)-2-O-methyl-3-O-octadecylcarbonate (Akt inhibitor), was as effective as Ly294002 in lowering the sensitivity threshold of HL60 cells to chemotherapeutic drugs, TRAIL, ATRA, and ionizing radiation. Our findings demonstrate that, at a concentration which does not affect PI3K activity, the Akt inhibitor markedly reduced resistance of HL60AR cells to etoposide, cytarabine, TRAIL, ATRA, and ionizing radiation. This effect was likely achieved through downregulation of expression of antiapoptotic proteins such as c-IAP1, c-IAP2, cFLIP(L), and of Bad phosphorylation on Ser 136. The Akt inhibitor did not influence PTEN activity. At variance with Ly294002, the Akt inhibitor did not negatively affect phosphorylation of protein kinase C-zeta and it was less effective in downregulating p70S6 kinase (p70S6K) activity. The Akt inhibitor increased sensitivity to apoptotic inducers of K562 and U937, but not of MOLT-4, leukemia cells. Overall, our results indicate that selective Akt pharmacological inhibitors might be used in the future for enhancing the sensitivity of leukemia cells to therapeutic treatments that induce apoptosis or for overcoming resistance to these treatments.

Antineoplastic Agents↗

Electromagnetic stimulation on the bone growth using backscattered electron imaging.

The events at the hydroxyapatite implant material/tissue interface following electromagnetic stimulation were studied in the rabbit. Two kinds of hydroxyapatite were used: natural (NA) and synthetic (HA) both with a grain size of <50 microm. Bone defects, artificially created in rabbit tibiae, were filled with the material examined. One group of animals was exposed immediately after surgery and every 12h thereafter to 30-min treatments with electromagnetic fields (PEMFs). A second group was used as a control (untreated). Two and 4 weeks after implantation, animals were sacrificed and bone samples processed for LM, TEM and SEM using a backscatter electron detector for the evaluation of bone growth. This study indicates that HA has more osteoconductivity than NA, and shows that PEMF-treatment results in a benefit in accelerating bone formation at early time periods.

Animals↗

Hierarchical structures in fibrillar collagens.

The collagen family includes several large transcripts, usually exceeding 1000 amino acid residues per single chain. As a group, they make up 1/3 of all the protein of the body and are responsible for modelling the framework of connective tissues; individually, they show both a wide variety and a complex hierarchy of mutual interactions, and form a range of functional aggregates including a variety of fibrils, microfibrils and basal membranes. Of the collagens, the fibril-forming types (i.e. the types I, II III, V and XI) are the most abundant and the most extensively studied. At the primary structure level, the amino acid sequence of all collagens is now known in detail and it shows a distinctive domain organization, its composition being dominated by the amino acid glycine (roughly 1/3 of all residues) and by post-translational hydroxylation of proline and lysine residues. Collagen secondary and tertiary structure, which together give origin to a classic triple helix, were painstakingly determined in the 1950s and 1960s. In contrast with the primary, secondary and tertiary structure, the supramolecular arrangement within collagen fibres seems to be far more elusive, and none of the models so far advanced can be said to be universally accepted. Half a century of research and debate spawned numerous mutually incompatible models, most of them focussing either on a quasi-crystalline supramolecular array or on several forms of microfibrillar aggregates, while radial fibrils, epitaxial fibrils and other structural models have almost been ignored. In many cases, data gained with a single technique from a single tissue were arbitrarily given a general legitimacy, whilst other well-documented morphological evidence went virtually unnoticed by the scientific community.Moreover, in recent years there has been a growing interest in the multiple interactions of collagens with the other macromolecules of the extra-cellular matrix, as their structure and their functional role become known. It is now indisputable that collagen interacts and forms functional entities with several other macromolecules of the extracellual matrix. This paper will succinctly review some current concepts on the structural biology of collagen higher-order structures.

Animals↗

Contemporaneous anatomic collections and scientific papers from the 19th century school of anatomy of Bologna: preliminary report.

Recently, a strict relationship was demonstrated between scientific pathology reports of the 19th century and a large number of specimens from the museum of pathology 'Cesare Taruffi' of Bologna. Such an experience suggested verifying whether a similar relationship exists between the 19th-century collections of the museum of anatomy and the contemporaneous anatomic scientific literature. The purpose of this preliminary report is to illustrate the first documented samples recovered in Bologna in order to promote such an inventory of old anatomic and pathologic specimens in other museums.

Anatomy↗

Collagen structure and functional implications.

The bio-mechanical requirements to which the connective tissue is subjected suggest that a causal correlation exist between the substructure and the collagen fibril function. We discuss the relationship between the inner structure of collagen fibrils, their diameter, their spatial layout and the functional requirements they have to withstand, and suggest that collagen fibrils may belong to two different forms indicated as "T-type" and "C-type". The first class, consisting of large, heterogeneous fibrils, parallely tightly packed, subjected to tensile stress along their axis is found in highly tensile structures such as tendons, ligaments and bone. The other class, consisting of small, homogeneous fibrils, helically arranged, resisting multidirectional stresses, is mostly present within highly compliant tissues such as blood vessel walls, skin and nerve sheaths. What causes these architectures to appear is discussed in detail in this review.

Animals↗