PubMed Health⌕ Search

Biomedical subjects

A Svec

Publications and source records attributed to A Svec.

11 recordsLinked to original sources

A modified method for the characterisation and activity determination of large area sources.

Large area sources emitting alpha and beta radiations, respectively, are often used for calibrations of surface contamination monitors and meters. It is well known, however, that their properties are strongly influenced by their construction and by their active layer preparation. Non-uniformity of activity distributions over the active surface and the thickness of absorption and backscattering layers cause changes not only in the ratio of particle emission rate and activity but also in emitted particle spectra distributions. Consequently, different sources need to be characterised by one or more parameters related to their emitted particle spectra and used for their activity determination. A modified method based on simple particle absorption spectrometry has been developed. The correlation between a source characteristic parameter and its radiation detection efficiency is utilised for its activity estimation.

Calibration↗

Re-fixation in a lymph node revealing solution is a powerful method for identifying lymph nodes in colorectal resection specimens.

AIM: To verify an impact of a lymph node revealing solution (LRS) on the number of lymph nodes (LN) revealed in colorectal resection specimens. MATERIAL AND METHOD: Fifty-nine cases of rectosigmoid carcinomas divided into two subgroups-stage pT2&3 (20 cases) and ypT2&3 (with pre-operative radiotherapy-39 cases)-were formalin fixed for 42-72 h, serially sectioned and re-fixed in LRS containing ethanol, diethyl ether, glacial acetic acid, and formalin for 24 h. The number of LNs was matched to a control group consisting of 34 cases of colorectal carcinoma, 14 pT2&3 and 20 ypT2&3 rectosigmoid carcinomas examined routinely. Results were statistically tested by Student's t-test. RESULTS: In the study group the total number of revealed LNs was 869, range 1-48, average 14.7 per specimen, median 15. In the control group the number of LNs was 200, range 0-13, average 5.9 per specimen, median 6. The difference between the study and the control group was statistically significant (P = 0.05). CONCLUSION: Using LRS leads to a significant increase in the number of revealed LNs in colorectal resection specimens and makes it possible to find more than 12 LNs in a majority of stage pT2 and pT3 adenocarcinomas.

Acetic Acid↗

[Matrix-producing breast carcinoma with myoepithelial differentiation--description of 11 cases and review of literature aimed at histogenesis and differential diagnosis].

OBJECTIVE: Presentation of variable morphology of the so-called matrix-producing carcinoma, the rare variant of metaplastic breast carcinoma. Establish the extent of myoepithelial phenotype by immunohistochemistry and assess behaviour of the lesion. DESIGN: Review of clinicopathologic data of 11 cases. SETTING: Private Biopsy Lab s.r.o., Pilsen and Sikl's Department of Pathology, Charles University and Faculty Hospital, Pilsen. METHODS: Included are eleven cases from Breast Registry, Biopsy Lab s.r.o., Pilsen and Pathology Department, Faculty Hospital in Hradec Králové and Martin and from Biopsy Lab in Horovice. Analyzed were morphology, stage, grade and follow up. Myoepithelial phenotype was demonstrated immunohistochemically by LSAB+ system (DAKO) and seven conventional myoepithelial markers (GFAP, aktin S, calponin, cytokeratin 14, p63, CD10 and P-cadherin) were used. Oncogene p53 and Her2/neu were also detected. RESULTS: Matrix-producing carcinoma is an extremely rare type of metaplastic carcinoma of the breast, where high-grade epithelial component continually merges with heterologous mesenchymal chondroid component without overt spindle cell sarcomatoid pattern in between. There were all women at the age of 32 to 86-years (average 54 years, median 52 years) and the maximum tumor diameter ranged from 18 to 60 mm (average 32 mm). The axillary LN was positive in six cases in the time of diagnosis. The follow up available in 9 women ranged from three months to ten years (average 24 months); dissemination of the disease was observed in three cases; 2 of these patients died of disease after three and ten years, respectively. The heterologous mesenchymal chondroid component was produced in two different ways; one displayed typical structure of low-grade hyaline cartilage, in the second one the epithelial tumorous cells were embedded in the homogenous eosinophilic extracellular matrix giving appearance of chondroid aura. Metaplastic component constituted 5-75% of the tumor volume. Immunohistochemical evidence of myoepithelial differentiation in all neoplasms was demonstrated, with at least two conventional myoepithelial markers (actin S, calponin, GFAP, CK14, CD10, p63 and P-cadherin) being positive in every case. Expression of p53 was identified in six cases, all tumors were Her2/neu negative. Histologically the metastases were formed either by carcinoma cells only, or more frequently, they replicated the structure of primary lesion. CONCLUSION: As a rare entity, matrix-producing carcinoma of breast displaying myoepithelial phenotype, deserves separate position in tumor classification. It differs from conventional myoepithelial carcinoma and from heterologous metaplastic carcinoma, where the matrix emanate from undifferentiated sarcomatous tissue, but precise histogenesis in not clear yet. This is a very aggressive lesion and our findings show that previous reports of indolent behaviour were preliminary. Spectrum of differential diagnosis, namely benign mixed tumor, phylloid tumor, primary breast sarcoma and colloid carcinoma warrant clear knowledge about this unique entity.

Adult↗

Osteoid osteoma of olecranon process of ulna in subchondral location.

We present a case of a 15-year-old girl with osteoid osteoma in an unusual subchondral localization of the olecranon. Unspecific complaints and minimal X-ray findings at the onset of the disease led to an incorrect diagnosis and more than 2 years of inefficient treatment.

Adolescent↗

An ionization chamber as a secondary standard for activity

A commercially-available radionuclide calibrator is used to maintain the unit of activity in the Slovak Institute of Metrology (SMU) and to check and verify activity meters in the field of nuclear medicine. The calibration of the instrument is described. The long-term stability is checked at regular intervals by means of 137Cs and 226Ra reference sources. A slow decrease of efficiency of about 2% per year has been observed, which has to be corrected for. An energy-dependent efficiency curve of the ionization chamber is established by transfer of calibration factors from a similar instrument at the Physikalisch-Technische Bundesanstalt (PTB). The curve has been checked by measurements with activity standards of 60Co, 54Mn, 22Na, 85Sr, 65Zn, 88Y, 57Co, 139Ce, 137Cs, 125I, 241Am, 210Pb and 109Cd. The established curve permits one to calculate calibration factors for additional short-lived radionuclides used in nuclear medicine. An overall uncertainty was obtained for activity measurements with calculated calibration factors under standard measurement conditions of better than 1.8%.

Journal Article↗

High prevalence of Helicobacter heilmannii-associated gastritis in a small, predominantly rural area: further evidence in support of a zoonosis?

BACKGROUND: Primary hosts of Helicobacter heilmannii are domestic animals--cats, dogs and pigs, but rarely is it detected in gastric biopsies from humans. We found H. heilmannii in gastric biopsies obtained from patients living in a predominantly rural area. METHODS: We evaluated geographic and demographic data from the area and calculated both the total prevalence and the prevalence in each community in this area. Chi-squared test and exploratory data analysis were used for statistical evaluation. Histologic and clinical data were recorded. RESULTS: Forty-three communities, mostly rural, were identified in the area, the size of which is about 200 km2. H. heilmannii was detected in 33 patients (prevalence 2%) living in 20 communities. The prevalence of H. heilmannii statistically significantly varied in those communities from 0.06%-1.1%. It was possible to infer that there is a negative correlation between prevalence and community size. Chronic active gastritis was diagnosed in all patients. The active inflammation became inactive after eradication of H. heilmannii via common anti-Helicobacter therapy. CONCLUSION: A high prevalence of H. heilmannii-associated gastritis in a small, predominantly rural area and statistically significant differences in prevalence from one community to the next, i.e. highest in the smallest village and lowest in a small town with a rather urban lifestyle, were found. In our opinion, these prevalence rates may be a consequence of transmission of the infection from domestic animals, because animal-human contact is generally more common in villages than in towns.

Animals↗

Pigmented microcystic chromophobe cell carcinoma: a unique variant of renal cell carcinoma.

Five cases of pigmented chromophobe renal cell carcinoma are presented. The patients included four men and one woman between the ages of 60 and 73 years (median age, 66.5 years), who presented with symptoms due to their renal mass. Surgical resection of the renal mass was performed in all patients. Grossly, the tumors were well encapsulated, yellow to dark gray, with a vague nodular pattern on cut surface. The tumors varied between 2.5 and 9 cm in greatest diameter. Histologically, all tumors shared similar features, namely, a malignant cellular proliferation composed of deeply eosinophilic to clear cytoplasm with round nuclei and inconspicuous nucleoli. The cellular proliferation was arranged in a microcystic and/or microalveolar pattern. In one tumor, conventional areas of clear cell carcinoma in association with the chromophobe component were present. In addition, all tumors contained pigmented areas, which were shown by light microscopy to have features of lipochrome pigment. Ultrastructural studies of these areas demonstrated the presence of intracytoplasmic polygonal to round, electron-dense pigment granules, which in some areas seemed to coalesce to form larger granules. In addition, numerous mitochondria and cytoplasmic vesicles were present. The cases described herein highlight an additional morphologic variant of chromophobe renal cell carcinoma.

Aged↗

Comparison of ionization chamber efficiencies for activity measurements.

The calibration of ionization chamber measuring systems in terms of activity is described. The energy-dependent efficiency curves of three chambers at the Bureau International des Poids et Mesures, the National Physical Laboratory and the Physikalisch-Technische Bundesanstalt are determined and compared using a fitting procedure for the experimental radionuclide efficiencies by the Microsoft (MS) EXCEL Solver program. An estimation of the uncertainty of the efficiency curves and the deviations of experimental and calculated radionuclide efficiencies are given. By this fitting method, discrepancies in the efficiency determination can be detected at a level of about one percent. Systematic deviations entering into the calculations either from emission probabilities per decay or from absolute activity standardization are discussed.

Algorithms↗

Fitting methods for constructing energy-dependent efficiency curves and their application to ionization chamber measurements.

An ionization chamber without and with an iron liner (absorber) was calibrated by a set of radionuclide activity standards of the Physikalisch-Technische Bundesanstalt (PTB). The ionization chamber is used as a secondary standard measuring system for activity at the Slovak Institute of Metrology (SMU). Energy-dependent photon-efficiency curves were established for the ionization chamber in defined measurement geometry without and with the liner, and radionuclide efficiencies were calculated. Programmed calculation with an analytical efficiency function and a nonlinear regression algorithm of Microsoft (MS) Excel for fitting was used. Efficiencies from bremsstrahlung of pure beta-particle emitters were calibrated achieving a 10% accuracy level. Such efficiency components are added to obtain the total radionuclide efficiency of photon emitters after beta decay. The method yields differences of experimental and calculated radionuclide efficiencies for most of the photon-emitting radionuclides in the order of a few percent.

Journal Article↗